Laserfiche WebLink
OVEN <br />RACK <br />OVEN <br />RACK <br />OVEN <br />RACK <br />AREA LEGEND <br />ASSEMBLY <br />BUSINESS <br />KITCHEN <br />STORAGE <br />UNOCUPIED <br />PATH B <br />PATH A 112' - 0" <br />110' - 0" <br />175 SF <br />OFFICE <br />124 SF <br />EMPLOYEE AREA <br />150 SF <br />UTILITY <br />47 SF <br />RESTROOM <br />563 SF <br />DRY STORAGE <br />289 SF <br />WALK-IN CHILLER <br />82 SF <br />WALK-IN COOLER <br />288 SF <br />CUSTOMER LOBBY <br />183 SF <br />SALES <br />286 SF <br />CRAFT AREA <br />345 SF <br />BAKING / FROSTING <br />PROJECT LOCATION <br />PROJECT LOCATION <br />HA <br />Z <br />E <br />L <br /> <br />D <br />E <br />L <br />L <br /> <br />R <br />D <br />. <br />WESTFIELD RD <br />S <br />M <br />I <br />L <br />L <br /> <br />C <br />R <br />E <br />E <br />K <br /> <br />R <br />D <br />PROPERTY LINE <br />ITEMS NOT INCLUDED UNDER THE PERMITTING OF THESE DRAWINGS <br />SIGNAGE, SPRINKLERS, WALK-IN UNIT <br />• SIGN DRAWINGS SHALL BE SUBMITTED SEPARATELY BY OTHERS. SIGN SHOP DRAWINGS IDENTIFYING THE METHOD AND MATERIALS <br />OF ITS ASSEMBLY AND ATTACHMENT DETAILS SHALL BE PROVIDED PRIOR TO INSTALLATION. <br />• IF REQUIRED GC RESPONSIBLE FOR OBTAINING ALL NECESSARY FIRE ALARM AND SPRINKLER DRAWINGS AND SUBMITTING FOR <br />REQUIRED PERMITS <br />NOTE: AREA SQUARE FOOTAGE SHOWN ARE FOR THE BUILDING CODE REVIEWERS <br />USE AND REVIEW ONLY. AREA CALCULATIONS SHOWN NOT RELATED TO TENANT <br />LEASING INFORMATION. <br />TOTAL:PERSONS: <br />NOTE: AREA SQUARE FOOTAGES <br />SHOWN ARE FOR THE BUILDING <br />CODE REVIEWERS USE AND REVIEW <br />ONLY. AREA CALCULATIONS <br />SHOWN ARE NOT RELATED TO <br />TENANT LEASING INFORMATION. <br />INTERIOR TENANT FIT-OUT OF AN EXISTING TENANT SPACE. QUICK TRANSACTION FOOD TENANT SELLING BUNDT CAKES. SCOPE TO <br />INCLUDE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DESIGN. <br />TRAVEL DISTANCES <br />Path ID Actual Travel Distance <br />A 67' - 4" <br />B 67' - 4" <br />SHEET NO SHEET NAME <br />Current <br />Revision <br />Current <br />Revision Date <br />G-101 PROJECT INFORMATION 4 03/10/2026 <br />G-102 ACCESSIBILITY NOTES AND DETAILS 3 02/09/2026 <br />G-103 RESPONSIBILITY SCHEDULE 2 12/05/2025 <br />G-104 DISABLED ACCESS COMPLIANCE 4 03/10/2026 <br />G-105 SITE PLAN 4 03/10/2026 <br />A-100 DEMOLITION PLAN <br />A-101 FLOOR PLAN & ENLARGED RESTROOM PLAN 3 02/09/2026 <br />A-102 SCHEDULES AND DETAILS 4 03/10/2026 <br />A-103 FIXTURE AND EQUIPMENT PLAN 1 09/23/2025 <br />A-104 WALK-IN COOLER PLANS & SHELVING ELEVATIONS 2 12/05/2025 <br />A-105 FINISH PLAN & SCHEDULE 1 09/23/2025 <br />A-201 REFLECTED CEILING PLAN <br />A-301 INTERIOR DECOR <br />A-302 FRONT OF HOUSE ELEVATIONS <br />A-303 KITCHEN ELEVATIONS 1 09/23/2025 <br />A-304 KITCHEN ELEVATIONS 2 12/05/2025 <br />A-401 MILLWORK / COUNTER DETAILS & ELEVATIONS <br />R-100 PHONE / DATA / CABLE NETWORKING <br />R-101 PHONE / DATA / CABLE NETWORKING <br />E-000 ELECTRICAL NOTES, SYMBOLS & LEGENDS <br />E-100 ELECTRICAL LIGHTING PLAN <br />E-200 ELECTRICAL POWER PLAN <br />E-210 ELECTRICAL ROOF EQUIPMENT POWER PLAN <br />E-300 POWER ONE-LINE, PANEL SCHEDULES & DETAILS <br />E-400 ELECTRICAL SPECIFICATIONS <br />E-410 ELECTRICAL SPECIFICATIONS <br />E-500 ENERGY FORMS <br />M-000 MECHANICAL SPECIFICATIONS <br />M-010 MECHANICAL SPECIFICATIONS <br />M-020 MECHANICAL SPECIFICATIONS <br />M-100 HVAC PLAN <br />M-200 MECHANICAL SCHEDULES <br />M-300 MECHANICAL DETAILS <br />MP-100 MECHANICAL ROOF PLAN <br />P-000 PLUMBING SPECIFICATIONS <br />P-100 PLUMBING SUPPLY PLAN <br />P-100.1 PLUMBING SITE PLAN <br />P-200 PLUMBING DWV PLAN <br />P-300 PLUMBING DETAILS <br />S1.0 STRUCTURAL NOTES <br />S2.0 STRUCTURAL DETAILS AND PARTIAL PLAN <br />PROJECT GENERAL NOTES:BUILDING CODE SUMMARY: <br />OCCUPANT & TRAVEL DISTANCE SCHEDULES: <br />PROJECT SCOPE SUMMARY: <br />DEFERRED SUBMITTALS: <br />SHEET INDEX: <br />CITY OF SANTA ANA, CA -ORANGE COUNTY <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA FUEL GAS CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA ACCESSIBILITY CODE <br />2022 CALIFORNIA PLUMBING CODE <br />OCCUPANCY CLASSIFICATION <br />TYPE OF CONSTRUCTION <br />TOTAL NUMBER OF STORIES <br />FIRE SUPPRESSION SYSTEM <br />B -BUSINESS <br />VB SHELL BUILDING <br />1 LEVEL <br />NOT SPRINKLERED <br />BUILDING CODE AGENCY/JURISDICTION <br />BUILDING CODE <br />PROJECT DIRECTORY: <br />BUILDING DEPARTMENT: <br />CITY OF SANTA ANA <br />20 CIVIC CENTER PLAZA <br />ROSS ANNEX, M-20 <br />SANTA ANA, CA 92701 <br />FRANCHISEE PARTNER: <br />Fresh Dining Concepts LLC <br />HEALTH DEPARTMENT: <br />ORANGE COUNTY HEALTH <br />405 W. 5TH ST. <br />SANTA ANA, CA 92701 <br />ARCHITECTURAL DESIGN CONTACT: <br />OCULUS INC. <br />1 SOUTH MEMORIAL DRIVE <br />SUITE 1500 <br />ST. LOUIS, MO 63102 <br />ENGINEER CONTACT: <br />CASE ENGINEERING <br />796 MERUS COURT <br />FENTON, MO 63026 <br />ENGINEER OF RECORD: <br />JOHN VIRTUDAZO <br />636-349-1600 <br />FAX: 636-349-1730 <br />DARRELL CASE <br />FRANCHISOR: <br />NOTHING BUNDT FRANCHISING, INC. <br />5005 LYNDON B. JOHNSON FWY <br />SUITE 600 <br />DALLAS, TX 75244 <br />ELENI MEJIAS <br />972-632-8722 <br />ELENI.MEJIAS@NOTHINGBUNDTCAKES.COM <br />CHELSEA PENISTON <br />CHELSEAP@OCULUSINC.COM <br />314-367-6100 <br />714-647-5800 <br />714-433-6074 <br />WWW.OCHEALTHINFO.COM <br />OKEY M. REESE <br />724-875-8580 <br />OREESE@FRESHDININGCONCEPTS.COM <br />LOCATION PLAN:KEY PLAN: <br />1. THE USE OF THESE DOCUMENTS IS RESTRICTED <br />TO THE ORIGINAL SITE FOR WHICH THEY ARE <br />PREPARED. REUSE OR REPRODUCTION OF THE <br />DOCUMENTS, (WHOLE OR IN PART) FOR ANY <br />OTHER PURPOSE IS PROHIBITED. OCULUS, INC. <br />RETAINS ALL RIGHTS OF <br />OWNERSHIP FOR THESE DOCUMENTS. <br />2. THE GENERAL CONDITIONS AS SET FORTH BY <br />OCULUS, INC. SHALL APPLY TO THE PROJECT. <br />3. THE CONTRACTOR AND SUB-CONTRACTORS SHALL <br />BE SOLELY RESPONSIBLE FOR COMPLYING WITH <br />FEDERAL, STATE, AND LOCAL SAFETY <br />REQUIREMENTS TOGETHER WITH EXERCISING <br />PRECAUTIONS FOR THE PROTECTION OF PERSONS <br />INCLUDING EMPLOYEES AND PROPERTY. IT IS THE <br />SOLE RESPONSIBILITY OF THE CONTRACTOR AND <br />SUB-CONTRACTORS TO INITIATE, MAINTAIN AND <br />SUPERVISE ALL SAFETY REQUIREMENTS, <br />PRECAUTIONS, AND PROGRAMS IN CONNECTION <br />WITH THE WORK. <br />4. THE GENERAL CONTRACTOR SHALL BE <br />RESPONSIBLE TO COORDINATE WORK AND FOR <br />THE MEANS, METHODS, PROCEDURES, <br />TECHNIQUES, AND SEQUENCES OF <br />CONSTRUCTION. <br />5. THE GENERAL CONTRACTOR SHALL PROVIDE <br />REQUIRED PERMITS, FEES, AND INSPECTIONS AS <br />MAY BE REQUIRED BY GOVERNING BODIES HAVING <br />LEGAL JURISDICTION. <br />6. THE GENERAL CONTRACTOR IS TO GUARANTEE <br />WORK INCLUDING WORK DONE BY <br />SUB-CONTRACTORS FOR A PERIOD OF (1) YEAR <br />COMMENCING WITH THE DATE OF SUBSTANTIAL <br />COMPLETION OF THE WORK. <br />7. THE GENERAL CONTRACTOR SHALL BE <br />RESPONSIBLE FOR THE SCHEDULING AND THE <br />EXPERIENCE OF ON-SITE TESTING AND <br />INSPECTION SERVICES AS LISTED IN THE <br />SPECIFICATIONS AND GENERAL CONDITIONS. <br />8. WHEN CONTRACTOR ACCEPTS DELIVERY OF ITEMS <br />NOTED ON PLANS EITHER IN CONTRACT OR NOT IN <br />CONTRACT HE SHALL BE RESPONSIBLE FOR LOSS <br />AND/OR DAMAGE TO THESE ITEMS. <br />9. THE GENERAL CONTRACTOR SHALL HAVE A JOB <br />PHONE ON THE PREMISES DURING ENTIRE <br />CONSTRUCTION PERIOD. <br />10. THE GENERAL CONTRACTOR IS TO HAVE A FULL <br />TIME QUALIFIED SUPERVISOR ON THE SITE WHILE <br />WORK IS BEING PERFORMED. <br />11. DIMENSIONS SHOWN ARE ACTUAL UNLESS <br />SPECIFICALLY NOTED OTHERWISE. <br />12. SAW CUTTING AND CORING LOCATIONS SHALL BE <br />REVIEWED IN FIELD BY THE GENERAL <br />CONTRACTOR PRIOR TO CUTTING/ CORING. <br />13. THE GENERAL CONTRACTOR IS TO VERIFY <br />DIMENSIONS AND EXISTING FIELD CONDITIONS <br />WITH THE DRAWINGS. IN PARTICULAR OVERALL <br />WALL DIMENSIONS, INCOMING UTILITIES, ETC. <br />GENERAL CONTRACTOR IS TO REPORT <br />IMMEDIATELY TO THE ARCHITECT ANY VARIANCES <br />OR FIELD CONDITIONS THAT MAY CAUSE <br />CONSTRUCTION PROBLEMS PRIOR TO <br />COMMENCING WORK. <br />14. DO NOT SCALE THE DRAWINGS. WRITTEN <br />DIMENSIONS GOVERN. PARTITION LOCATIONS, ALL <br />DOOR AND OPENING LOCATIONS SHALL BE <br />SHOWN ON FLOOR PLAN. IN CASE OF CONFLICT <br />NOTIFY THE ARCHITECT. FLOOR PLAN BY <br />ARCHITECT SUPERSEDED OTHER PLANS. <br />DIMENSIONS MARKED "CLEAR" SHALL BE <br />MAINTAINED AND SHALL ALLOW FOR THICKNESS <br />OF FINISHES INCLUDING CONCRETE TOPPING, <br />CERAMIC TILE, ETC. "HOLD" DENOTES CRITICAL <br />DIMENSIONS. <br />15. DIMENSIONS SHOWN ARE TO FACE OF MATERIAL <br />UNLESS SPECIFICALLY NOTED OTHERWISE. <br />16. DIMENSIONS ON ARCHITECTURAL DRAWINGS <br />LOCATING STRUCTURAL ELEMENTS ARE TO <br />CENTERLINE OF STEEL COLUMNS AND STEEL <br />BEAMS UNLESS NOTED OTHERWISE. <br />17. GC TO PROVIDE 2A10BC FIRE EXTINGUISHERS AT A <br />RATE OF ONE EXTINGUISHER PER 3,000 SF FOR <br />LIGHT HAZARD. FIRE EXTINGUISHERS ARE PLACED <br />SO THAT NO POINT OF THE BUILDING IS FURTHER <br />THAN 75'-0" FROM AN EXTINGUISHER. TYPE K FIRE <br />EXTINGUISHERS SHALL BE PROVIDED NEAR THE <br />KITCHEN EQUIPMENT AND IN THE PATH OF TRAVEL. <br />18. POST OCCUPANT LOAD SIGN. G. C. SHALL ACQUIRE <br />APPROPRIATE WORDING FOR POSTING OF ROOM <br />CAPACITY FROM PRESIDING AGENCY AND <br />FABRICATE ACCORDINGLY. <br />19. GC TO COORDINATE LOCATIONS OF REQUIRED <br />BLOCKING IN ADVANCE. <br />20. GC TO CONTACT MANUFACTURER/SUPPLIER OF <br />ITEM(S) RECEIVED NON-FUNCTIONING OR <br />DAMAGED FOR PROPER RETURN PROCEDURES TO <br />RESULT IN NO INCREASE OF COST TO THE OWNER. <br />1/8" = 1'-0"S9 OCCUPANCY & EGRESS PLAN <br />ROOM NAME AREA OCCUPANCY TYPE LOAD FACTOR <br />OCCUPANT <br />COUNT <br />BAKING / FROSTING 345 SF KITCHEN 200 SF 2 <br />CUSTOMER LOBBY 288 SF ASSEMBLY 15 SF 20 <br />SALES 183 SF BUSINESS 150 SF 2 <br />DRY STORAGE 563 SF STORAGE 300 SF 2 <br />WALK-IN CHILLER 289 SF STORAGE 300 SF 1 <br />WALK-IN COOLER 82 SF STORAGE 300 SF 1 <br />CRAFT AREA 286 SF KITCHEN 200 SF 2 <br />RESTROOM 47 SF UNOCUPIED 0 SF <br />UTILITY 150 SF KITCHEN 200 SF 1 <br />EMPLOYEE AREA 124 SF STORAGE 300 SF 1 <br />OFFICE 175 SF KITCHEN 200 SF 1 <br />2531 SF 33 <br />CODE EXEMPTION SUMMARY: <br />2022 CALIFORNIA BUILDING CODE <br />2902.3, EXCEPTION #2: PUBLIC TOILET FACILITIES ARE NOT REQUIRED FOR SPACES INTENDED FOR QUICK TRANSACTIONS, INCLUDING <br />TAKE-OUT, PICKUP AND DROP-OFF, HAVING A PUBLIC ACCESS AREA LESS THAN OR EQUAL TO 300 SF. <br />2022 CALIFORNIA BUILDING CODE <br />303.1.2 #1: A ROOM OR SPACE USED FOR ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS AND <br />ACCESSORY TO ANOTHER OCCUPANCY SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY OR AS PART OF THAT OCCUPANCY. <br />2022 CALIFORNIA BUILDING CODE <br />11B-202.4 #2: IF THE FOLLOWING ELEMENTS OF A PATH OF TRAVEL HAVE BEEN CONSTRUCTED OR ALTERED IN COMPLIANCE WITH THE <br />ACCESSIBILITY REQUIREMENTS OF THE IMMEDIATELY PRECEDING EDITION OF THE CALIFORNIA BUILDING CODE, IT SHALL NOT BE <br />REQUIRED TO RETROFIT SUCH ELEMENTS TO REFLECT THE INCREMENTAL CHANGES IN THIS CODE SOLELY BECAUSE OF AN ALTERATION <br />TO AN AREA SERVED BY THOSE ELEMENTS OF THE PATH OF TRAVEL: <br />1. A PRIMARY ENTRANCE TO THE BUILDING OR FACILITY <br />2. TOILET AND BATHING FACILITIES SERVING THE AREA <br />3. DRINKING FOUNTAINS SERVING THE AREA <br />4. PUBLIC TELEPHONES SERVING THE AREA <br />5. SIGNS <br />OCCUPANT LOAD <br />OCCUPANT LOAD SQ. FT. <br />TOTAL LEASABLE SQ. FT. <br />TOTAL EXITS REQUIRED <br />EXITS PROVIDED <br />REQUIRED MINIMUM DISTANCE BETWEEN DOORS PER CODE <br />ACTUAL DISTANCE BETWEEN EXIT DOORS <br />MAXIMUM TRAVEL DISTANCE <br />WIDTH OF EXIT PASSAGEWAY (TABLE 1020.3) <br />SEE OCCUPANT SCHEDULE ON THIS SHEET <br />2,543 SF <br />1 <br />2 <br />112'-0" / 2 = 56'-0" <br />110'-0" <br />75' MAX COMMON PATH -200' MAX EXIT TRAVEL DISTANCE <br />WIDTH NOT LESS THAN 36" (< 50 OCCUPANTS) <br />SANTA ANA - SOUTH(#0972) <br />16842136571210911141315 <br />84213657 1210911 1413 15 16 <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />Checked by <br />These drawings/specifications are the property of Oculus Inc. They are <br />furnished as contract documents only. The seal(s) and signature(s) apply <br />only to the document to which they are affixed, and expressly disclaim any <br />responsibility for all other plans, specifications, estimates, reports or other <br />documents or instruments relating to or intended to be used for any part or <br />parts of the architectural or engineering project. Additionally these <br />drawings and seal(s) shall in no way convey or imply any type of warranty or <br />certification relating to the performance of products and materials beyond <br />those provided by their respective manufacturer. <br />© 2025 Oculus Inc. <br />Drawn by <br />Issue Date <br />Project # <br />Scale <br />Client Approval <br />As indicated <br />3/ <br />1 <br />9 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />5 <br />: <br />2 <br />1 <br />: <br />2 <br />7 <br /> <br />P <br />M <br />MT <br />BJK <br />07/09/2025 <br />69325-CA03 <br />G-101 <br />PROJECT <br />INFORMATION <br />ISSUED FOR PERMIT <br />33 <br />1 <br />3 <br /> <br />S <br />. <br /> <br />B <br />R <br />I <br />S <br />T <br />O <br />L <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />( <br /># <br />0 <br />9 <br />7 <br />2 <br />) <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />( <br /># <br />0 <br />9 <br />7 <br />2 <br />) <br />07/09/2025 <br />3313 S. BRISTOL ST. <br />SANTA ANA, CA 92704 <br /># Description Date <br />2 HEALTH AND CITY <br />COMMENTS <br />12/05/2025 <br />4 CITY COMMENTS 03/10/2026 <br />2 <br />2 <br />4