Laserfiche WebLink
BOT. OF ACT <br />10'-0" <br />PRE-FABRICATED <br />WALK-IN COOLER / <br />FREEZER <br />S/S CLOSURE PANEL w/ <br />HEMMED EDGE AT BOTTOM. <br />FASTENED TO ANGLE AND <br />FREEZER. EXTEND 4-12" <br />DOWNSIDE OF FREEZER <br />TOP OF COOLER / FREEZER BOX <br />1" ALUMINUM ANGLE ATTACHED <br />TO CEILING GRID BEYOND <br />ACOUSTICAL CEILING <br />TILE AND 'T' BAR GRID <br />288 SF <br />CUSTOMER LOBBY <br />183 SF <br />SALES <br />286 SF <br />CRAFT AREA <br />345 SF <br />BAKING / FROSTING <br />82 SF <br />WALK-IN COOLER <br />289 SF <br />WALK-IN CHILLER <br />563 SF <br />DRY STORAGE <br />47 SF <br />RESTROOM <br />150 SF <br />UTILITY <br />175 SF <br />OFFICE <br />124 SF <br />EMPLOYEE AREA A.F.F. <br />ACT-2 <br />10' - 2" <br />A.F.F. <br />ACT-1 <br />10' - 0" <br />A.F.F. <br />GYP (PT-01) <br />8' - 0" <br />A.F.F. <br />ACT-1 <br />10' - 0" <br />A.F.F. <br />ACT-1 <br />10' - 0" <br />EX1 <br />EQEQ <br />1' <br /> <br />- <br /> <br />0 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />S2 <br />S2 <br />S2 <br />S2 <br />B B B <br />BBB <br />B B BEQEQ <br />D <br />EX1 <br />EX1 <br />S <br />1 <br />2 <br />2 <br />3 <br />A <br />A A <br />A <br />AA <br />AA <br />A A <br />A <br />A <br />AA <br />AA <br />AA <br />A <br />A <br />4 <br />EQ <br />EQ <br />EQ4' - 0"EQ <br />A <br />A <br />AA <br />AA <br />SCC <br />NOTE: MOUNTING, NUMBER OF FACES, <br />TYPE LAMPS NUMBER <br />CATALOG DESCRIPTIONMANUF <br />EZPAN2X4-50YN/D10LED <br />3500K <br />RAB LIGHTING <br />LED <br />3000K <br />90 CRI <br />AND CHEVRONS AS INDICATED ON PLANS. VERIFY PRIOR TO ORDERING. <br />2'x4' LAY-IN FLUSH LENSE FIXTURE WITH ALUMINUM HOUSING, FROSTED <br />POLYSTYRENE LENS, 5,260 LUMEN OUTPUT AND (1) ONE 0-10V DIMMING DRIVER. <br />2'x2' LAY-IN TROFFER FIXTURE WITH COLD-ROLLED STEEL CONSTRUCTION, <br />FROSTED POLYCARBONATE LENS, 2,676 LUMEN OUTPUT AND (1) ONE 0-10V <br />DIMMING DRIVER. <br />SWISH2X2-19YN/D10LED <br />3500K <br />RAB LIGHTING <br />C 6" DIAMETER RECESSED IC AIR-TITE FIXTURE WITH ALUMINUM <br />CONSTRUCTION AND MATTE WHITE TRIM RING. <br />HOUSING: H750ICAT <br />TRIM: LT560WH12930 <br />HALO <br />D 2" ROUND ADJUSTABLE LED DOWNLIGHT.2AR-L7-9-27-DIM-UNV-R-W- <br />OF-WH-XX-N <br />LED <br />2700K <br />H.E. WILLIAMS <br />S2 LED-12V <br />THERMOPLASTIC COMBINATION LED EXIT SIGN WITH (2) 3.6V, ADJUSTABLE LED <br />HEADS,UNIVERSAL MOUNTING, RED LETTERS ON A WHITE STENCIL FACE, <br />CHEVRON KNOCKOUTS AND HIGH OUTPUT NICKEL CADMIUM BATTERY. <br />INCLUDES 2.5W OF REMOTE CAPACITY. <br />ECC R REM M6LEDLITHONIAEX1 <br />B <br />A <br />NOTES: <br />1. G.C. TO ORDER AND INSTALL FIXTURES FROM LISTED VENDOR CONTACT <br />2. ALLOW 1-1/4" PERIMETER EDGE FRAMING FOR ACT-2. CUT LEAST AMOUNT OF CEILING TILES AS POSSIBLE. <br />ADJUST SOFFIT ACCORDINGLY. <br />3. G.C. TO INSTALL CEILING GRID TIE WIRES AS PER CODE. GRID TIE WIRES TO ATTACH TO STEEL JOISTS ABOVE. <br />DO NOT ATTACH TO HVAC DUCTWORK OR METAL DECK. <br />4. REFERENCE FINISH SCHEDULE FOR CEILING MATERIALS. <br />5. G.C. SHALL PROVIDE ALL THIS LIGHTING AS NOTED. CONTACT THE VENDOR FOR NATIONAL ACCOUNT PRICING. <br />6. COORDINATE LOCATION OF EMERGENCY BALLASTS/FIXTURES WITH ELECTRICAL PLANS <br />VENDOR: JIM ELLIS <br />MELETIO ELECTRICAL SUPPLY CO. <br />P.O. BOX 540816 10930 <br />HARRY HINES BLVD. <br />DALLAS, TEXAS 75220 <br />972.559.6943 <br />JELLIS@MELETIO.COM <br />S <br />G.C. ELECTRICIAN TO INSTALL OWNER PROVIDED CEILING MOUNTED <br />SPEAKERS AND PULL 2 CONDUCTOR 14 GAUGE SPEAKER WIRE w/ 7'-0" PIGTAIL <br />AND TERMINATE AT MEDIA PLAYER AND AMP MUSIC SYSTEM. INSTALLATION <br />OF EQUIPMENT BY OTHERS. <br />BY OWNER-- BY OWNERSPEAKER <br />12" ROUND FROSTED GAZE PENDANT, SATIN BRASS, BTM. OF FIXTURE AT 9 W. <br />84" A.F.F. FOR 11' - CEILINGS <br />96" A.F.F. FOR 11' + CEILINGS <br />MODEL: GAZE-56892-SB-WGCRAFTMADE <br />SEE CEILING PLAN <br />SPLICES AND INTERSECTIONS OF RUNNERS SHALL BE ATTACHED <br />WITH MECHANICAL INTERLOCKING CONNECTORS SUCH AS POP <br />RIVETS, SCREWS, PINS, PLATES WITH BENT TABS, OR OTHER <br />APPROVED CONNECTORS. DESIGN CONNECTORS FOR 2 X DESIGN <br />LOAD OR ULTIMATE AXIAL TENSION OR COMPRESSION (MINIMUM 60 <br />POUNDS). <br />OR: CROSS-FURRING SHALL BE SECURELY ATTACHED TO THE MAIN <br />RUNNER BY SADDLE-TYING WITH NOT LESS THAN ONE STRAND OF <br />NO.16 OR TWO STRANDS OF NO.18 US. GAUGE TIE WIRE OR <br />APPROVED EQUIVALENT ATTACHMENTS. <br />NOTE: <br />METAL SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND FOR LAY-IN <br />PANEL CEILINGS SHALL BE INSTALLED IN ACCORDANCE WITH <br />CHICAGO METALLIC I.C.B.O. #1905. <br />HANGER WIRE ALLOWABLE TENSION <br />#12 <br />#11 <br />#10 <br />170# <br />225# <br />300# <br />SUSPENDED CEILING DETAIL AT WALL <br />RUNNER TO MAIN RUNNER <br />LOCKING CLIP TO FASTEN CROSS <br />RUNNERS AND FURRING: THE MAIN RUNNER AND CROSS FURRING SHALL BE NOT LESS THAN THE SIZES SET FORTH, EXCEPT <br />THAT OTHER STEEL SECTIONS OF EQUIVALENT STRENGTH MAY BE SUBSTITUTED FOR THOSE SET FORTH. <br />HANGERS: HANGERS FOR SUSPENDED CEILING SHALL BE NOT LESS THAN THE SIZES SET FORTH, FASTENED TO OR EMBEDDED IN <br />THE STRUCTURAL FRAMING, MASONRY, OR CONCRETE. HANGERS SHALL BE SADDLE-TIED AROUND MAIN RUNNERS TO DEVELOP <br />THE FULL STRENGTH OF THE HANGERS. LOWER ENDS OF FLAT HANGERS SHALL BE BOLTED WITH 1/4" BOLTS TO RUNNER <br />CHANNELS OR BENT TIGHTLY AROUND RUNNERS AND BOLTED TO THE MAIN PART OF THE HANNGERS. <br />MECHANICAL AND LIGHT FIXTURES: MUST BE CONNECTED TO ONE (1) VERTICAL 12 GA. WIRE ATTACHED TO OPPOSING CORNERS <br />ALONG THE FIXTURE'S DIAGONAL. THESE WIRES MAY BE SLACK. PROVIDE PERIMETER VERTICAL WEIS 8" OUT FROM WALL. (UBC <br />STDS. NO. 25.213, 25.214) <br />45 <br />45 <br />45 <br />45 <br />#12 GA 45 SPLAY WIRE BRACING IN PLANE OF MAIN <br />RUNNER. ALL WIRES ATTACHED TO MAIN RUNNER. 4 <br />DIRECTIONS. THESE HORIZONTAL RESTRAINT POINTS <br />SHALL BE PLACED 12' O.C. IN BOTH DIRECTIONS WITH <br />THE FIRST POINT WITHIN 6' FROM EACH WALL. (UBC <br />STDS 25.213, 25.214) <br />F=ZICpWp WHERE Cp=0.EF=SICpWp <br />Wp=TRIBUTARY AREA x WEIGHT OF CEILING (4 <br />MIN.) <br />CROSS RUNNER <br />F=ZICpWpSPLICE <br />2" MAX <br />MAIN RUNNER @ <br />4'-0" O.C. <br />VERTICAL STRUT SUPPORTED FROM THE <br />STRUCTURAL MEMBERS ABOVE TO THE MAIN <br />RUNNER @ 12' O.C. IN BOTH DIRECTIONS, <br />STARTING 6' FROM WALLS. STRUTS UP TO 4' <br />LONG MAY USE A MIN. 25 GA. METAL STUD <br />WITH 7/8" FLANGES. STRUTS TO BE PLACED <br />WITHING 2" OF THE FOUR SPLAYED WIRES. <br />WALL TRIM <br />1' - 2"0' - 4" <br />LATERAL FORCE BRACING <br />NOT TO EXCEED 12" <br />8" MAX <br />OC IN BOTH DIRECTIONS <br />WITH THE FIRST PINT <br />WITH 4" FROM EA WALL <br />CROSS RUNNER <br />PANEL <br />CONT. HORIZ. STRUT <br />TO PREVENT <br />SPREADING OF <br />RUNNERS <br />SPLAY BRACE <br />WIRE <br />CROSS RUNNER <br />SEISMIC LOCKING PIN <br />HANGER WIRE <br />MAIN RUNNER <br />LATERAL FORCE-BRACING MEMBERS FOR SUSPENDED CEILINGS SHALL BE A <br />MINIMUM OF 6" FROM ALL HORIZONTAL PIPING OR DUCT WORK NOT PROVIDED WITH <br />BRACING RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE <br />ATTACHED TO THE GRID AND STRUCTURE AND SHALL SUPPORT A DESIGN LOAD THE <br />GREATER OF 200 LBS OR THE ACTUAL LOAD, WITH A SAFETY FACTOR OF 2. (UBC <br />STDS. 25.213, 25.214) <br />1/4" = 1'-0"S1 REFLECTED CEILING PLAN <br />16842136571210911141315 <br />84213657 1210911 1413 15 16 <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />Checked by <br />These drawings/specifications are the property of Oculus Inc. They are <br />furnished as contract documents only. The seal(s) and signature(s) apply <br />only to the document to which they are affixed, and expressly disclaim any <br />responsibility for all other plans, specifications, estimates, reports or other <br />documents or instruments relating to or intended to be used for any part or <br />parts of the architectural or engineering project. Additionally these <br />drawings and seal(s) shall in no way convey or imply any type of warranty or <br />certification relating to the performance of products and materials beyond <br />those provided by their respective manufacturer. <br />© 2025 Oculus Inc. <br />Drawn by <br />Issue Date <br />Project # <br />Scale <br />Client Approval <br />As indicated <br />3/ <br />1 <br />9 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />5 <br />: <br />2 <br />2 <br />: <br />4 <br />0 <br /> <br />P <br />M <br />MT <br />BJK <br />07/09/2025 <br />69325-CA03 <br />A-201 <br />REFLECTED CEILING <br />PLAN <br />ISSUED FOR PERMIT <br />33 <br />1 <br />3 <br /> <br />S <br />. <br /> <br />B <br />R <br />I <br />S <br />T <br />O <br />L <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />( <br /># <br />0 <br />9 <br />7 <br />2 <br />) <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />( <br /># <br />0 <br />9 <br />7 <br />2 <br />) <br />07/09/2025 <br />3" = 1'-0"K12 SECTION @ COOLER CEILING ENCLOSURE <br />LIGHTING LEGEND <br />1 IF DISCREPANCIES ARE FOUND BETWEEN ENGINEERING (MEP) AND ARCHITECTURAL DRAWINGS, ENGINEERING DRAWINGS SHALL GOVERN. <br />2 GC TO NOTIFY ARCHITECT OF ANY DISCREPENCIES PRIOR TO CONSTRUCTION. <br />3 MAINTAIN EXISTING FIRE RATINGS AT TENANT SEPARATION WALLS DURING DEMOLITION/CONSTRUCTION ACTIVITIES (IF APPLICABLE) <br />4 ALL DIMENSIONS ARE FINISH TO FINISH UON <br />5 GC TO ORDER LIGHTING THROUGH BRAND STANDARD VENDOR. SEE LIGHTING LEGEND THIS SHEET. <br />6 GC TO COORDINATE WALL MOUNTED EMERGENCY LIGHT FIXTURE LOCATIONS WITH SPECIALTY WALL FINISHES AND GRAPHICS. <br />7 GC TO PROVIDE AND INSTALL 2x2 ACCESS PANELS, AS REQUIRED, IN AREAS OF GYP CEILING (FACTORY FINISH WHITE) <br />KEY # KEYNOTE TEXT <br />1 COORDINATE POWER REQUIREMENTS ON EXTERIOR OF BUILDING w/APPROVED SIGNAGE PACKAGE BY OTHERS. <br />2 CENTER LIGHTING OVER SALES COUNTERS. ENSURE THEY DO NOT CONFLICT WITH THE CEILING GRID. <br />3 COORDINATE LOCATION FOR BOW CHAIN w/ OWNER <br />4 DISCONTINUE CEILING TILE AT NEAREST 'T' GRID OVER COOLER/FREEZER. <br />KEYNOTES: <br />CEILING PLAN GENERAL NOTES: <br />1 1/2" = 1'-0"K6 SEISMIC BRACING DETAIL <br /># Description Date