Laserfiche WebLink
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND EXISTING CONDITIONS BEFORE <br />STARTING WORK AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES THAT ARE <br />FOUND. <br />2. DO NOT SCALE DETAILS OR DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS <br />WHERE REQUIRED. <br />3. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL <br />DETAILS. <br />4. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART OF THE WORK, THE <br />DETAILS USED SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. <br />5. WHEN A DETAIL IS IDENTIFIED AS TYPICAL, THE CONTRACTOR IS TO APPLY THIS DETAIL IN ESTIMATION <br />AND CONSTRUCTION TO EVERY LIKE CONDITION WHETHER OR NOT THE REFERENCE IS REPEATED IN <br />EVERY INSTANCE. <br />6. ALL WORK SHALL CONFORM TO THE 2025 EDITION OF THE CALIFORNIA BUILDING CODE (CBC) AND <br />OTHER REGULATORY AGENCIES WHO MAY HAVE AUTHORITY OVER THE WORK. <br />7. THESE DRAWINGS REPRESENT THE STRUCTURE IN ITS FINAL CONFIGURATION. IT IS THE <br />RESPONSIBILITY OF THE CONTRACTOR FOR ALL MEANS AND METHODS ASSOCIATED WITH ACHIEVING <br />THIS FINAL CONFIGURATION, INCLUDING BUT NOT LIMITED TO SHORING, BRACING OR SOILS <br />EXCAVATIONS. <br />8. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES ANY ITEMS THAT ARE TO BE INTEGRATED <br />INTO THE STRUCTURAL SYSTEM SUCH AS OPENINGS, PENETRATIONS, MECHANICAL AND ELECTRICAL <br />EQUIPMENT, ETC. SIZES AND LOCATIONS OF MECHANICAL AND OTHER EQUIPMENT THAT DIFFERS <br />FROM THOSE SHOWN ON THE CONTRACT DRAWINGS SHALL BE REPORTED TO THE <br />ARCHITECT/ENGINEER. CONTRACTOR SHALL TAKE MEASURES AS REQUIRED TO ENSURE THAT <br />CONSTRUCTION LOADS SHALL NOT EXCEED DESIGN LOADS FOR THE STRUCTURE. <br />9. ALL REFERENCED CODES AND STANDARDS SHALL BE THE LATEST APPROVED EDITION, U.O.N. <br />10. IN THE CASE OF DISCREPANCIES BETWEEN THE STRUCTURAL DRAWINGS AND SPECIFICATIONS, THE <br />INFORMATION SHOWN ON THE STRUCTURAL DRAWINGS SHALL GOVERN. <br />1. APPLICABLE CODES: <br />CALIFORNIA BUILDING CODE, 2022 EDITION <br />2. LIVE LOADS, UNIFORM AS FOLLOWS: <br />a. ROOF ............................................................... 20psf (REDUCIBLE) <br />3. SEISMIC DESIGN CRITERIA: <br />SITE CLASS D (DEFAULT) <br />SEISMIC DESIGN CATEGORY D <br />RISK CATEGORY II <br />Fa = 1.2 IP = 1.0 <br />SS = 1.284 aP = 2.5 <br />S1 = 0.460 RP = 6 <br />SDS = 1.027 <br />4. WIND DESIGN CRITERIA(LOW-RISE): <br />WIND EXPOSURE B V = 95mph <br />RISK CATEGORY II Kd = 0.85 <br />GCpi = ± 0.18 Kzt = 1.0 <br />P = qh (GCp - GCpi) Ke = 1.0 <br />COMPONENTS AND CLADDING: <br />GCp = SEE ASCE 7-16 CHAPTER 30, AS APPLICABLE <br />1. ALL FRAMING LUMBER SHALL BE DOUGLAS FIR-LARCH, GRADE MARKED AS FOLLOWS, UNLESS <br />OTHERWISE NOTED: <br />a. LIGHT FRAMING - "STANDARD" AND "STUD" <br />b. POSTS, BEAMS, AND HEADERS - "NO. 1" <br />c. BEARING STUDS AND SHEAR WALL STUDS - "NO. 2" <br />d. JOISTS, RAFTERS, AND PLATES - "NO. 2" <br />2. THE MOISTURE CONTENT IN USE SHALL NOT EXCEED 19 PERCENT. <br />3. INSTALL CONTINUOUS 2x SOLID BLOCKING BETWEEN ALL JOISTS AND RAFTERS AT SUPPORTS. <br />4. CROSS BRIDGING BETWEEN JOISTS AND RAFTERS MAY BE OMITTED WHERE THE COMPRESSION <br />EDGE IS CONTINUOUSLY CONNECTED TO THE SHEATHING AND MEMBERS ARE SMALLER THAN 2x12. <br />OTHERWISE, PROVIDE CROSS BRIDGING AT 8' - 0" MAXIMUM PER CBC SECTION 2308.4.6. <br />5. ALL NAILS SHALL BE COMMON NAILS U.O.N. <br />6. SHEATHING NAILS SHALL BE DRIVEN SO THAT THEIR HEAD IS FLUSH WITH THE SURFACE OF THE <br />SHEATHING. <br />7. BOLTS SHALL HAVE 7 DIAMETER MINIMUM END DISTANCE AND 4 DIAMETER MINIMUM EDGE DISTANCE. <br />8. ALL BOLTS SHALL BE FITTED WITH WASHERS. HOLES IN WOOD SHALL BE BORED WITH A BIT 1/32" TO <br />1/16" LARGER THAN THE BOLT DIAMETER. <br />9. LEAD HOLES FOR LAG SCREWS AND WOOD SCREWS SHALL BE PROVIDED IN ACCORDANCE WITH THE <br />"NATIONAL DESIGN STANDARD FOR WOOD CONSTRUCTION," LATEST APPROVED EDITION. <br />10. STEEL FRAMING CONNECTORS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, INC. <br />OR APPROVED EQUAL. <br />11. PLYWOOD FLOOR SHEATHING SHALL BE GLUED TO ALL FRAMING MEMBERS WITH AN APA APPROVED <br />ADHESIVE. <br />12. ORIENTED STRAND BOARD (OSB) IS AN ACCEPTABLE ALTERNATE FOR PLYWOOD WALL, FLOOR, AND <br />ROOF SHEATHING THAT IS NOT EXPOSED TO MOISTURE. <br />13. INSTALL FIRE BLOCKING IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING <br />FURRED SPACES, AT CEILING AND FLOOR SPACES AND AT OTHER LOCATIONS AS REQUIRED PER CBC <br />SECTION 717. <br />14. ALL HARDWARE, BOLTS, AND NAILS IN PRESERVATIVE-TREATED, FIRE-RETARDANT-TREATED OR <br />EXPOSED LUMBER SHALL BE HOT-DIP GALVANIZED (ASTM A153) OR TYPE 304 STAINLESS STEEL <br />UNLESS OTHERWISE RECOMMENDED BY THE MANUFACTURER. <br />1. SPECIAL INSPECTIONS, STRUCTURAL TESTS, AND STRUCTURAL OBSERVATIONS SHALL COMPLY WITH <br />THE APPLICABLE PROVISIONS OF CHAPTER 17 OF THE 2022 CBC. <br />2. THE SPECIAL INSPECTOR MUST BE CERTIFIED BY THE CITY OR JURISDICTION HAVING AUTHORITY OVER <br />THE WORK, IN THE CATEGORY OF WORK REQUIRED TO HAVE SPECIAL INSPECTION. <br />3. THE SPECIAL INSPECTIONS IDENTIFIED ON PLANS ARE IN ADDITION TO AND NOT A SUBSTITUTE FOR <br />THOSE INSPECTIONS REQUIRED TO BE PERFORMED BY THE BUILDING OFFICIAL. <br />4. A PROPERTY OWNER'S FINAL REPORT FORM FOR WORK REQUIRED TO HAVE SPECIAL INSPECTIONS, <br />TESTING AND STRUCTURAL OBSERVATIONS MUST BE COMPLETED BY THE PROPERTY OWNER, <br />PROPERTY OWNER'S AGENT OF RECORD, ARCHITECT OF RECORD OR ENGINEER OF RECORD AND <br />SUBMITTED TO THE BUILDING OFFICIAL. <br />5. THE FABRICATOR MUST BE REGISTERED AND APPROVED BY THE CITY OR JURISDICTION HAVING <br />AUTHORITY OVER THE WORK, SPECIAL INSPECTIONS ARE NOT REQUIRED FOR THE FABRICATION OF <br />MEMBERS AND ASSEMBLIES ON THE PREMISES OF THE FABRICATOR'S SHOP. <br />6. THE FABRICATOR SHALL SUBMIT A "APPLICATION TO PERFORM OFF-SITE FABRICATION" TO THE <br />INSPECTION SERVICES DIVISION FOR APPROVAL PRIOR TO COMMENCEMNT OF FABRICATION. <br />7. THE FABRICATOR SHALL SUBMIT A "CERTIFICATE OF COMPLIANCE FOR OFF-SITE FABRICATION" TO THE <br />BUILDING OFFICIAL PRIOR TO THE ERECTION OF FABRICATED ITEMS AND ASSEMBLIES. <br />8. THE CONSTRUCTION MATERIALS TESTING LABORATORY MUST BE APPROVED BY THE CITY OR <br />JURISDICTION HAVING AUTHORITY OVER THE WORK, FOR TESTING OF MATERIALS, SYSTEMS, <br />COMPONENTS AND EQUIPMENT. <br />9. WHERE MATERIALS OR ASSEMBLIES ARE REQUIRED BY THE BUILDING CODE TO BE LABELED, SUCH <br />MATERIALS AND ASSEMBLIES SHALL BE LABELED BY AN AGENCY APPROVED BY THE CITY OR <br />JURISDICTION HAVING AUTHORITY OVER THE WORK, IN ACCORDANCE WITH CBC SECTION 1703. <br />PRODUCTS AND MATERIALS TO BE LABELED SHALL BE TESTED, INSPECTED AND LABELED IN <br />ACCORDANCE WITH THE PROCEDURES SET FORTH IN CBC SECTIONS 1703.5.1 THROUGH 1703.5.4. <br />IDENTIFY ON PLANS THE NAME AND ADDRESS OF THE TESTING / INSPECTION AGENT. <br />1. MECHANICAL AND ELECTRICAL COMPONENTS PER CBC SECTION 1705.13.6. <br />STRUCTURAL <br />JEFFREY W.DENSLEYREGISTEREDPROFESSIONALENGINEER <br />STATE OF CALIFORNIA <br />No. 5535 <br />As indicated <br />12 <br />/ <br />1 <br />5 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />1 <br />: <br />4 <br />1 <br />: <br />5 <br />0 <br /> <br />P <br />M <br />JD <br />KL <br />12/19/2025 <br />14479A.00 <br />ISSUED FOR PERMIT <br />33 <br />1 <br />3 <br /> <br />S <br />. <br /> <br />B <br />R <br />I <br />S <br />T <br />O <br />L <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />( <br /># <br />0 <br />9 <br />7 <br />2 <br />) <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />( <br /># <br />0 <br />9 <br />7 <br />2 <br />) <br />#Description Date <br />168421 3 65 7 1210911 1413 15 <br />8421 3 65 7 1210911 1413 15 16 <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />Checked by <br />These drawings/specifications are the property of Oculus Inc. They are <br />furnished as contract documents only. The seal(s) and signature(s) apply <br />only to the document to which they are affixed, and expressly disclaim any <br />responsibility for all other plans, specifications, estimates, reports or other <br />documents or instruments relating to or intended to be used for any part or <br />parts of the architectural or engineering project. Additionally these <br />drawings and seal(s) shall in no way convey or imply any type of warranty or <br />certification relating to the performance of products and materials beyond <br />those provided by their respective manufacturer. <br />© 2025 Oculus Inc. <br />Drawn by <br />Issue Date <br />Project # <br />Scale <br />Client Approval <br />STRUCTURAL <br />NOTES <br />12/19/2025 <br />S1.0 <br />GENERAL <br />DESIGN CRITERIA <br />TIMBER <br />GENERAL SPECIAL INSPECTION NOTES <br />ITEMS REQUIRING SPECIAL INSPECTION