Laserfiche WebLink
79 <br />6 <br /> <br />M <br />e <br />r <br />u <br />s <br /> <br />C <br />o <br />u <br />r <br />t <br />St <br />. <br /> <br />L <br />o <br />u <br />i <br />s <br />, <br /> <br />M <br />O <br /> <br />6 <br />3 <br />0 <br />2 <br />6 <br />T <br />6 <br />3 <br />6 <br />. <br />3 <br />4 <br />9 <br />. <br />1 <br />6 <br />0 <br />0 <br />F <br />6 <br />3 <br />6 <br />. <br />3 <br />4 <br />9 <br />. <br />1 <br />7 <br />3 <br />0 <br />16842136571210911141315 <br />84213657 1210911 1413 15 16 <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />Checked by <br />Drawn by <br />Issue Date <br />Project # <br />Scale <br />Client Approval <br />TI <br /> <br />T <br />E <br />M <br />P <br />L <br />A <br />T <br />E <br /> <br />V <br />1 <br />. <br />0 <br />, <br />10 <br />- <br />1 <br />1 <br />- <br />2 <br />0 <br />1 <br />1 <br />SANTA ANA - SOUTH <br />(#0972) <br />3313 S. BRISTOL ST. <br />SANTA ANA, CA 92704 <br />AS INDICATED <br />07/09/2025 <br />69325-CA03 <br />ISSUED FOR <br />PERMIT <br />#Description Date <br />These drawings/specifications are the property of Oculus Inc. They are <br />furnished as contract documents only. The seal(s) and signature(s) apply <br />only to the document to which they are affixed, and expressly disclaim <br />any responsibility for all other plans, specifications, estimates, reports or <br />other documents or instruments relating to or intended to be used for any <br />part or parts of the architectural or engineering project. Additionally these <br />drawings and seal(s) shall in no way convey or imply any type of warranty <br />or certification relating to the performance of products and materials <br />beyond those provided by their respective manufacturer. <br />© 2025 Oculus Inc. <br />01/05/2026 <br />Dan Conrad, Engineer <br />CA # E 17866 <br />LOW VOLTAGE BELL <br />EXHAUST FAN <br />1 LAMP STRIPLIGHT <br />LOW VOLTAGE <br />LIGHTING PANEL <br />20A, 1P, 125V, DEDICATED GROUNDING TYPE DOUBLE DUPLEX RECEPTACLE <br />INCANDESCENT FIXTURE. TYPE `G'. CIRCUIT #11. SWITCH a. <br />12" ABOVE FLOOR LINE OF AREA WHERE SHOWN <br />FLUORESCENT FIXTURE. R = EXISTING RELOCATED <br />20A, 1P, 125V, GROUNDING TYPE DOUBLE DUPLEX RECEPTACLE <br />UNFUSED SAFETY SWITCH (SWITCH AMPS) <br />FUSED SAFETY SWITCH (SWICH AMPS / FUSE AMPS)30A/20A <br />30A <br />+12" <br />LV <br />11a <br />B <br />CONDUIT DOWN <br />HOME RUN <br />JUNCTION BOX <br />CONDUIT IN CEILING OR WALL 2 #12 THWN-CU <br />3 #12 THWN-CU IN 1/2" CONDUIT (2 CIR. & 1 NEUTRAL WIRES) <br />4 #12 THWN-CU IN 3/4" CONDUIT (3 CIR. & 1 NEUTRAL WIRES) <br />3 #12 THWN-CU IN 1/2" CONDUIT (1 CIR. WITH DEDICATED GND) <br />20A, 1P, 125V, GROUNDING TYPE DUPLEX RECEPTACLE, <br />20A, 1P, 125V, DEDICATED GROUNDING TYPE DUPLEX RECEPTACLE <br />CONDUIT BELOW FLOOR <br />CONDUIT UP +2" UNLESS NOTED <br />20A, 1P, 125V, GFCI TYPE DUPLEX RECEPTACLE <br />SYMBOL DESCRIPTION <br />F SD <br />D FIRE ALARM DUCT SMOKE DETECTOR <br />FLUORESCENT FIXTURE WITH EMERGENCY BALLAST. NL = NIGHT LIGHT <br />WALL MOUNTED EMERGENCY LIGHT. R = EXISTING RELOCATED <br />NL <br />R <br />R <br />R E = EXISTING; R = EXISTING RELOCATED <br />E <br />POWER PANEL <br />ELECTRICAL SYMBOLS LEGEND <br />GFCI <br />20A, 1P, 125V, GFCI TYPE DUPLEX RECEPTACLE <br />GFCI <br />SYMBOLS LEGEND NOTES: <br />NOT ALL SYMBOLS SHOWN IN THIS LEGND MAY APPEAR ON THE DRAWINGS. <br />WHERE CEILINGS DO NOT EXIST TO STUB CONDUITS ABOVE FOR LOW VOLTAGE, CONDUITS <br />SHALL BE STUBBED UP TO BOTTOM OF STRUCTURE ABOVE. IN FINISHED AREAS, PROVIDE <br />COMPLETE CONDUIT PATHWAYS, INCLUDING PULL-BOXES UNLESS OTHERWISE DIRECTED. <br />WHERE HARD INACCESSIBLE CEILING EXIST, PROVIDE COMPLETE CONTINUOUS CONDUIT <br />PATHWAYS, INCLUDING PULL-BOXES AND ACCESS PANELS FOR LOW VOLTAGE UNLESS <br />OTHERWISE DIRECTED. PROVIDE CONDUIT SLEEVES TRAVERSING OVER INACCESSIBLE <br />CEILINGS BETWEEN AREAS WITH ACCESSIBLE CEILINGS AS REQUIRED. VERIFY JUNCTION <br />BOXES ABOVE INACCESSIBLE CEILINGS ARE WITHIN REACH OF THE ACCESS PANEL AND CAN <br />BE ACCESSIBLE PER NEC AND LOCAL CODES. <br />1. <br />2. <br />3. <br />+144" <br />+18" <br />+24" <br />+26" <br />+48" <br />CEILING <br />+48" <br />+48" <br />1 @ +36" <br />+18" <br />+6" <br />+18" <br />+84" <br />PHOTOCELLS <br />RECEPTACLES/OUTLETS (CENTERLINE) <br />RECEPTACLES (EXTERIOR) <br />RECEPTACLES/OUTLETS (GARAGE) <br />RECEPTACLES (EQUIPMENT ROOMS) <br />REMOTE INDICATING LIGHT (EQUIP RMS) <br />REMOTE INDICATING LIGHT (FINISHED <br />AREAS) <br />SAFETY SWITCHES <br />STARTERS <br />SWITCHES (CENTERLINE) <br />TELEPHONES (PUBLIC) <br />TELEPHONES (PUBLIC) <br />TELEPHYONE DATA OUTLETS <br />(CENTERLINE) <br />TELEPHONE TERMINAL BOARD (BOTTOM) <br />TELEVISION OUTLETS <br />VISIBLE APPLIANCES (CENTERLINE) <br />+84" <br />+48" <br />+48" <br />+84" <br />+48" <br />+60" <br />+120" <br />+60" <br />+36" <br />+48" <br />+72" <br />AUDIBLE APPLIANCE <br />ALARMS <br />ANNUNCIATOR PANELS <br />CLOCK OUTLETS (CENTERLINE) <br />CONTROLS (CENTERLINE) <br />EXIT SIGNS (WALL MOUNTED TO <br />BOTTOM) <br />FIRE ALARM ANNUNCIATOR PANEL <br />FIRE ALARM BELL (EXTERIOR) <br />FIRE ALARM PANEL / UNIT <br />INTERCOM (AREA ONLY) <br />INTERCOMS <br />PANELS/PANEL BOARDS (TOP) <br />PULL STATIONS (HANDLE) <br />STANDARD MOUNTING HEIGHTS <br />AFF DESCRIPTION AFF DESCRIPTION <br />+80" <br />+48" <br />+48" <br />+48" <br />1 @ +48" <br />SYMBOL DESCRIPTION <br />GENERAL SYMBOLS LEGEND <br />## <br />## <br />## <br />MECHANICAL EQUIPMENT IDENTIFACTION TAG (TOP ## = EQUIPMENT TYPE, <br />BOTTOM ## = EQUIPMENT NUMBER) <br />KEYED NOTE TAG NUMBER <br />###DOOR NUMBER TAG <br />DETAIL TAG (DET = DETAIL NUMBER, SHEET = SHEET DETAIL IS FOUND ON)DET <br />SHEET <br />DETAIL TAG (ELEV = ELEVATION NUMBER, SHEET = SHEET DETAIL IS FOUND ON)ELEV <br />SHEET <br />GENERAL NOTES: <br />ALL WIRING LAYOUTS, PIPING LAYOUTS AND DUCT LAYOUTS ARE SCHEMATIC. EXACT LOCATIONS SHALL BE <br />DETERMINED BY THE CONSTRUCTION AND AND STRUCTURE OF THE BUILDING AND SHALL BE VERIFIED AND <br />COORDINATED IN THE FIELD. EACH TRADE CONTRACTOR SHALL VERIFY WITH THE GENERAL CONTRACTOR THAT <br />HE HAS THOROUGHLY REVIEWED AND COORDINATED ALL LOCATIONS AND ROUTINGS WITH ALL OTHER TRADES <br />PRIOR TO FABRICATION OF CONDUITS, DUCTS, OR PIPING, AND THE START OF INSTALLATION OF SAME <br />(INCLUDING SPRINKLER PIPING WHEN PRESENT IN A JOB). ANY INSTALLATION OR CONSTRUCTION CONFLICTS <br />WHICH OCCUR IN THE FIELD SHALL BE RESOLVED BY THE TRADE CONTRACTOR TO THE SATISFACTION OF THE <br />OWNER AND ARCHITECT AT NO EXPENSE TO THE OWNER, ARCHITECT, AND/OR GENERAL CONTRACTOR. <br />CONTACT THE ARCHITECT, ENGINEER, OR OWNER PRIOR T BIDDING FOR INTERPRETATIONS AND <br />CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET DESIGN INTENT. CLARIFICATIONS <br />MADE BY THE ARCHITECT, ENGINEER, OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT <br />CONTRACTOR'S COST. <br />BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL <br />INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING <br />CODES, THE PLANS, AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, <br />ENGINEER, OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. <br />1. <br />2. <br />3. <br />DEMOLITION NOTES: <br />IN EVERY INSTANCE OF DEMOLITION AND/OR REMODELING, THE ELECTRICAL SHALL FIGURE A COMPLETE JOB AS <br />NONE OTHER SHALL BE ACCEPTED. <br />THE DRAWINGS ARE TO BE USED ONLY AS A GUIDELINE FOR DEMOLITION. THE ELECTRICAL CONTRACTOR MUST <br />VISIT THE SITE PRIOR TO BIDDING TO VERIFY ALL WORK REQUIRED FOR A COMPLETE JOB AND INCLUDE THE <br />COST OF SUCH WORK IN HIS BID. <br />THE ELECTRICAL CONTRACTOR SHALL MAINTAIN EXISTING SERVICES TO AND IN THE EXISTING AREA AS <br />REQUIRED. <br />IF NECESSARY, THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE IN THE EXISTING AREAS. <br />THE ELECTRICAL CONTRACTOR SHALL DISCONNECT AND REMOVE ELECTRIC SERVICE TO ALL MECHANICAL <br />EQUIPMENT BEING REMOVED AS A RESULT OF THE REMODELING. <br />ELECTRICAL EQUIPMENT AND DEVICES SHALL BE REMOVED COMPLETE INCLUDING CONDUIT AND WIRE. <br />FLUSH MOUNTED WALL OUTLETS SHALL BE BLANKED-FF WITH A COVERPLATE. COVERPLATE COLOR SHALL BE <br />SELECTED BY ARCHITECT. <br />ANY EXISTING CONDUIT, WIRING AND/OR ELECTRICAL AND MECHANICAL DEVICES BEING DISTURBED BY THE <br />WORK SHALL BE REWORKED BY THIS CONTRACTOR AS REQUIRED TO RETURN TO ITS FORMER EXISTING <br />OPERATING CONDITION. <br />ANY CIRCUITS FEEDING THROUGH DEVICES OR EQUIPMENT BEING RELOCATED, REWORKED, OR ABANDONED <br />AND SERVING OTHER ELECTRICAL DEVICE, AND/OR EQUIPMENT SHALL BE MAINTAINED BY PROVIDING J-BOXES <br />OR OTHER ACCEPTABLE METHOD AS REQUIRED. <br />ALL WALLS, CEILING, FLOORS, ETC. BEING DISTURBED BY THE WORK SHALL BE RETURNED TO FINISHED <br />CONDITIONS TO MATCH EXISTING BY THE ELECTRICAL CONTRACTOR AND HE SHALL DO HIS OWN CUTTING AND <br />PATCHING AS NECESSARY UNDER HIS CONTRACT. <br />THE EXISTING MATERIALS SHALL BE TURNED OVER TO THE OWNER. IF NOT REQUIRED BY OWNER, THE <br />ELECTRICAL CONTRACTOR SHALL REMOVE THESE MATERIALS FROM THE PREMISES. <br />NO CONDUIT, BOXES, WIRING OR CABLES SHALL BE INSTALLED WITHIN 1-1/2" OF THE LOWEST POINT OF THE <br />UNDERSIDE OF THE ROOF DECKING, NOR SHALL THEY BE INSTALLED CONCEALED WITHIN METAL-CORRUGATED <br />ROOF DECKING. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO REPLACE AND/OR REWORK <br />EXISTING CONDUIT, BOXES, WIRING, AND CABLING THAT IS NOT IN COMPLIANCE WITH THIS REQUIREMENT. <br />ALL CONDUIT AND CABLING SHALL BE PROPERLY SUPPORTED AS REQUIRED BY THE NATIONAL ELECTRICAL <br />CODE. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO REPLACE AND/OR REWORK EXISTING <br />CONDUIT AND/OR CABLING THAT IS NOT IN COMPLIANCE WITH THIS REQUIREMENT. <br />CONTRACTOR SHALL FIELD VERIFY SLAB ON GRADE FLOOR CONSTRUCTION TYPE PRIOR TO CUTTING. UNDER <br />NO CIRCUMSTANCES SHALL THE CONTRACTOR CUT A STRUCTURAL FLOOR SLAB THICKER THAN FOUR INCHES <br />(4") WITHOUT PRIOR WRITTEN APPROVAL FROM ENGINEER OF RECORD. NOTIFY ENGINEER OF RECORD OF ANY <br />SLAB THICKNESS GREATER THAN FOUR INCHES (4") PRIOR TO PROCEEDING WITH ANY SAW CUTTING. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />ROUGH-IN NOTES: <br />ALL ELECTRICAL OUTLETS SHOWN ON SHEET E2.0 ARE FOR FIXTURES AND EQUIPMENT SPECIFIED AS FURNISHED <br />BY THE KITCHEN EQUIPMENT CONTRACTOR, UNLESS OTHERWISE NOTED FOR ANY ADDITIONAL CONVENIENCE <br />OUTLETS, SEE OTHER ELECTRICAL DRAWINGS & REQUIREMENTS. <br />ALL DIMENSIONS GIVEN ARE FROM COLUMN CENTERLINE AND/OR ROUGH WALLS. ELEVATIONS GIVEN ARE FROM <br />FINISHED FLOOR TO CENTERLINE OF OUTLET. <br />ALL ROUGH-INS SHOWN ARE TO BE RUN INSIDE WALLS, (EXCEPT STUB-UPS). LOCATIONS INDICATED POINT OF <br />EXIT FROM WALLS, CEILING OR FLOOR. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR REQUIREMENTS AND <br />MOUNTING HEIGHTS. <br />ELECTRICIAN TO BRANCH TO CONNECTION WHERE REQUIRED AND TO CONNECT ALL ELECTRICAL EQUIPMENT <br />AND FIXTURES AND INSTALL ANY INTERNAL WIRING REQUIRED IN THE FIXTURE INCLUDING INTER-WIRING TO <br />APPLIANCES AS REQUIRED BY THE SPECIFICATIONS AND/OR EQUIPMENT LOCATIONS. <br />ELECTRICAL CONTRACTOR TO VERIFY ELECTRICAL REQUIREMENTS OF ALL OWNER FURNISHED EQUIPMENT AND <br />MAKE ADJUSTMENTS AS REQUIRED BEFORE ELECTRICAL ROUGH-INS. <br />ALL ELECTRICAL COVER PLATES IN BUILDING STRUCTURE ARE TO BE FURNISHED BY THE ELECTRICIAN, WITH <br />RECEPTACLE. ALL MAIN BREAKER PANELS AND DISCONNECT SWITCHES REQUIRED BY OTHER ELECTRICAL <br />DRAWINGS ARE TO BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR AT TIME OF INSTALLATION. <br />UNLESS OTHERWISE INDICATED THE ELECTRICAL LOADS SPECIFIED ARE THE CONNECTED LOADS, FUSE OR <br />CIRCUIT BREAKER SIZE TO BE DETERMINED ACCORDINGLY, BASED UPON APPLICABLE CODE REQUIREMENTS. <br />OMISSIONS OR ERRORS IN THE SCHEDULE DO NO RELIEVE ELECTRICAL CONTRACTOR FROM COMPLETE AND <br />CORRECT FINAL CONNECTION RESPONSIBILITY. REVIEW OF EQUIPMENT BROCHURE BOOK AND SHOP DRAWINGS <br />WILL ASSURE CORRECTNESS OF THIS WORK. <br />ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL SWITCHES, STARTERS, DISCONNECTS, ETC. FOR ALL <br />EQUIPMENT UNLESS NOTED OTHERWISE. ALL DISCONNECTS OR LOCK-OUT DEVICES, STARTERS, ETC. TO MEET <br />N.E.C. AND O.S.H.A. STANDARDS. <br />RECEPTACLES SHALL BE GROUNDER PER N.E.C. AND O.S.H.A. AND TO HAVE NO GROUND FAULT PROTECTION, <br />EXCEPT WHEN OUTLET OCCURS WITHIN 6'-0" OF A SINK. RECEPTACLES WITHIN KITCHEN, AND PREP AREAS SHALL <br />HAVE GROUND FAULT PROTECTION (GFCI). <br />ELECTRICAL CONTRACTOR TO PROVIDE CONTROL WIRING AND ELECTRICAL SERVICE FOR REMOTE <br />REFRIGERATION SYSTEMS FOR WALK-IN BOXES, ALSO COORDINATE LOCATION FOR SERVICE WITH THE <br />ELECTRICAL ENGINEER. <br />ELECTRICAL CONTRACTOR TO PROVIDE WRAP AROUND HEATER CABLE ON ALL EVAPORATOR DRAIN LINES IN <br />WALK-IN FREEZERS. <br />ELECTRICAL CONTRACTOR TO INSTALL ALL LIGHTS IN WALK-IN COOLER/FREEZER AS REQUIRED, THRU DOOR <br />SWITCH. <br />ALL THREE (3) PHASE POWER CONNECTIONS TO BE ON A FOUR (4) WIRE SYSTEM, AND ALL SINGLE (1) PHASE <br />POWER CONNECTIONS TO BE ON A THREE (3) WIRE SYSTEM, UNLESS SPECIFIED OTHERWISE. <br />ALL WORK, RELATING TO THE INSTALLATION & HOOKUP OF THE SPECIFIED EQUIPMENT, IS TO BE MET WITH ALL <br />OTHER GOVERNMENT REGULATORY REQUIREMENTS. <br />ELECTRICAL CONTRACTOR IS REQUIRED TO FURNISH AND INSTALL ALL ELECTRICAL COMPONENTS NECESSARY <br />TO PROVIDE SERVICE TO LOCATIONS & EQUIPMENT SHOWN ON THE DRAWINGS UNLESS NOTED OTHERWISE. <br />PROVIDE A 4"X4" OUTLET BOX AND OUTLETS WITH 3/4" CONDUIT STUBBED INTO ACCESSIBLE CEILING WITH PULL <br />CORD FOR EACH TELEPHONE/DATA OUTLET. ALL OUTLETS SHALL BE FULLY INSTALLED TESTED FOR POLARITY <br />AND IN WORKING ORDER AS PART OF FINISH-OUT ELECTRICIAN'S SCOPE. <br />ELECTRICAL CONTRACTOR SHALL VERIFY WITH OWNER/SECURITY VENDOR WHETHER SECURITY J-BOXES <br />REQUIRE HARDWIRING OF CEILING MOUNTED CAMERAS OR RECEPTACLES FOR THE CAMERAS TO PLUG INTO. <br />SECURITY J-BOXES SHALL BE FLUSH MOUNTED TO CEILING. J-BOX/RECEPTACLE FACE PLATES IN CEILING SHALL <br />BE WHITE, UNLESS DIRECTED OTHERWISE ON ARCHITECTURAL PLANS. <br />FURROUT WALLS FOR ELECTRICAL AND PLUMBING AS NEEDED OR REQUIRED BY LANDLORD FOR ELECTRICAL <br />AND PLUMBING CONNECTIONS. <br />ELECTRICAL COVER PLATES TO BE WHITE WHEN LOCATED ON PAINTED "YELLOW" WALLS IN FRONT OF HOUSE <br />AND BROWN WHEN LOCATED ON "BROWN" WALLS IN FRONT OF HOUSE. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />15. <br />16. <br />17. <br />18. <br />19. <br />GENERAL NOTES: <br />FINAL CONNECTIONS TO LIGHT FIXTURES SHALL BE MADE WITH GREENFIELD FLEXIBLE CONDUIT. MAXIMUM <br />LENGTH OF FLEXIBLE CONDUIT SHALL BE 6'-0". <br />REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHT FIXTURES. <br />CONTRACTORS TO COORDINATE LOCATIONS OF LIGHTING, SPEAKERS, AIR DIFFUSERS, GRILLES, SPRINKLER <br />HEADS & THE LIKE, WITH REFLECTED CEILING LAY-OUTS AS REQUIRED & DIRECTED BY THE ARCHITECT. <br />ALL DEVICES, EQUIPMENT, FIXTURES, & THE LIKE, MUST BE GROUNDED BY USE OF A PROPERLY SIZED <br />GROUNDING CONDUCTOR. MECHANICAL/ ELECTRICAL BONDS OF THE METALLIC RACEWAY SYSTEM SHALL ALSO <br />BE MAINTAINED. <br />REFER TO MECHANICAL, PLUMBING, AND FIRE PROTECTION PLANS FOR EXACT LOCATION OF MECHANICAL AND <br />PLUMBING EQUIPMENT. COORDINATE LOCATION OF DISCONNECT SWITCH ASSOCIATED WITH EACH PIECE OF <br />EQUIPMENT WITH RESPECTIVE CONTRACTOR AND INSTALL IN ACCORDANCE WITH THE NEC. <br />REFER TO DIVISION 15 (21, 22 & 23) SPECIFICATIONS, HVAC, PLUMBING AND FIRE PROTECTION PLANS FOR <br />ADDITIONAL ELECTRICAL WORK REQUIREMENTS & COORDINATION. <br />ALL RECEPTACLES SHOWN BACK-TO-BACK IN WALLS SHALL BE SEPARATED HORIZONTALLY BY 8" MINIMUM. <br />WHERE OPEN WIRING METHODS FOR LOW VOLTAGE SYSTEMS ARE PERMITTED BY THE CONTRACT DOCUMENTS <br />AND LOCAL AUTHORITY, THE CONDUCTOR INSULATION MUST BE PLENUM RATED. <br />BRANCH CIRCUIT CONDUCTOR SIZES (& CONDUITS) SHALL BE INCREASED FROM THOSE INDICATED ON THE <br />PLANS TO PREVENT EXCESSIVE VOLTAGE DROP. BRANCH CIRCUITS SHALL BE INSTALLED WITH WIRES OF <br />SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL & THE LOADS DO NOT EXCEED A LIMIT OF 3%. <br />REGARDLESS OF THE TEMPERATURE RATING OF THE CONDUCTOR INSULATION, ALL CONDUCTOR AMPACITY <br />RATINGS FOR THIS PROJECT SHALL BE DETERMINED FROM THE 75°C CONDUCTOR TEMPERATURE RATINGS <br />INDICATED IN THE NEC TABLES. WHERE EQUIPMENT OR DEVICES ARE PROVIDED WITH TERMINALS/LUGS RATED <br />FOR 60°C, THE AMPACITY RATING OF THE 75°C CONDUCTOR SHALL BE LIMITED TO ITS ASSOCIATED 60°C RATING <br />AS INDICATED IN THE NEC TABLES. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO INCREASE THE <br />CONDUCTORS AND CONDUIT SIZE AS REQUIRED. <br />ALL 120V BRANCH CIRCUITS SHALL BE PROVIDED WITH SEPARATE NEUTRAL CONDUCTORS. SHARED NEUTRALS <br />WILL NOT BE PERMITTED FOR MULTI-CIRCUIT INSTALLATIONS. WHERE MULTIPLE CIRCUITS ARE RUN IN A <br />COMMON RACEWAY, THE AMPACITY OF THE CONDUCTORS SHALL BE PROPERLY DERATED & CONDUIT SHALL BE <br />SIZED PER CODE. UNDER NO CIRCUMSTANCES SHALL MORE THAN SIX (6) CURRENT CARRYING CONDUCTORS BE <br />RUN IN A SINGLE CONDUIT. REFERENCE NEC ARTICLE AND TABLE 310.15(B)(3)(A). <br />ALL CONDUITS SHALL CONTAIN A GROUND CONDUCTOR SIZED PER NEC TABLE #250.122. IN ADDITION, WHERE AN <br />ISOLATED, INSULATED GROUND IS REQUIRED, A SEPARATE GROUND CONDUCTOR WITH GREEN INSULATION <br />SHALL BE RUN FROM THE PANEL GROUND BUS TO THE ISOLATED GROUND CONNECTION OF THE DEVICE. IN NO <br />CASE SHALL THE SYSTEM GROUND (CONDUCTOR & ASSOCIATED OUTLET BOXES, CONDUIT & BUILDING STEEL) BE <br />ALLOWED TO CONTACT THE ISOLATED GROUND (CONDUCTOR & DEVICE). WHERE CIRCUIT CONDUCTORS ARE <br />INCREASED IN SIZE FOR ANY REASON (I.E. VOLTAGE DROP, DERATING, ETC.), THE GROUND CONDUCTOR SIZE <br />SHALL BE INCREASED PROPORTIONATELY (ACCORDING TO CIRCULAR MIL AREA) FROM THE SIZE REQUIRED BY <br />NEC TABLE #250.122. <br />ELECTRICAL INSTALLATION REQUIREMENTS FOR ALL HVAC, PLUMBING, FIRE PROTECTION, SPECIAL SYSTEMS <br />AND OWNER EQUIPMENT BEING FURNISHED BY OTHERS SHALL BE REVIEWED AND COORDINATED WITH OTHER <br />TRADES PRIOR TO ROUGH-IN. OBTAIN EQUIPMENT SHOP DRAWINGS FROM <br />INSTALLER/SUPPLIER/CONTRACTOR/OWNER FURNISHING EQUIPMENT, AS REQUIRED, FOR REVIEW AND <br />COORDINATION. CONTACT ARCHITECT/ENGINEER WITH ANY DISCREPANCIES FOUND BETWEEN CONSTRUCTION <br />DRAWINGS AND EQUIPMENT BEING FURNISHED PRIOR TO ROUGH-IN. <br />THE ELECTRICAL CONTRACTOR SHALL FURNISH ALL ACCESS PANELS, AS REQUIRED FOR SERVICING AND <br />TESTING, FOR EQUIPMENT AND/OR DEVICES FURNISHED UNDER HIS CONTRACT. THE GENERAL CONTRACTOR <br />SHALL INSTALL ACCESS PANELS. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE SIZE AND LOCATION <br />OF EACH ACCESS PANEL WITH THE ARCHITECT AND GENERAL CONTRACTOR PRIOR TO ROUGH-IN. <br />ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID ALL CUTTING, TRENCHING AND PATCHING ASSOCIATED <br />WITH THE ELECTRICAL INSTALLATION. <br />ALL PENETRATIONS IN OR THROUGH FIRE RATED ASSEMBLIES ASSOCIATED WITH THE ELECTRICAL INSTALLATION <br />SHALL BE FIRE-STOPPED USING A UL APPROVED METHOD. FURNISH AND INSTALL UL LISTED FIRE RATED <br />MATERIALS AND EQUIPMENT SUCH AS BOXES, PUTTY PADS, ENDOTHERMIC MAT, LIGHT FIXTURES WITH RATED <br />ENCLOSURES, ETC… TO COMPLY WITH CODE FOR PROJECT CONDITIONS. FURNISH AND INSTALL SLEEVES, <br />WHERE REQUIRED. UL APPROVED METHOD FOR FIRE STOPPING SHALL MEET OR EXCEED FIRE RATING OF <br />STRUCTURE BEING PENETRATED. REFERENCE ARCHITECTURAL PLANS FOR FIRE RATED STRUCTURES. <br />ALL ELECTRICAL EQUIPMENT AND DEVICES FOR THIS PROJECT MUST BE UL LISTED. DEVICES, EQUIPMENT, <br />SYSTEMS SHALL BE INSTALLED PER N.E.C. REQUIREMENTS AND MANUFACTURER'S INSTRUCTIONS. <br />ALL WORK SHOWN SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES, ORDINANCES, ETC. <br />EXIT SIGNS AND EMERGENCY LIGHTS SHALL HAVE THEIR OWN SELF-CONTAINED STANDBY BATTERY POWER <br />SUPPLY. IF LOCAL CODE REQUIRES A DIRECT TAP BEFORE ANY CIRCUIT BREAKERS THEN INCORPORATE INTO <br />THE FEEDER DIAGRAM. <br />PROVIDE EMERGENCY LIGHTING TO MEET THE REQUIRED FOOT CANDLE LEVEL PER LOCAL CODE. <br />LUMINAIRES INSTALLED IN CONTINUOUS ROWS SHALL BE GROUNDED WITH A CONDUCTOR ROUTED FROM <br />LUMINAIRE TO LUMINAIRE, MOUNTED TO EACH WITH GROUNDING LUG OR SCREW. ALIGNING CLIPS ARE NOT <br />ACCEPTABLE. LUMINAIRE GROUNDING SHALL BE INSTALLED IN COMPLIANCE WITH NATIONAL ELECTRICAL CODE, <br />ARTICLE 410-21. <br />CEILING LIGHTS ARE TO BE WIRED TO THE BAR JOIST MEMBERS AT THE DIAGONAL CORNERS. <br />COORDINATE LIGHTING WITH SPRINKLER & MECHANICAL DRAWINGS. <br />ALL RECEPTACLES AND SWITCHES SHALL HAVE TWO (2) REVOLUTIONS OF ELECTRICAL TAPE (SCOTCH 33+) OVER <br />ALL THE TERMINALS, TO PREVENT ACCIDENTAL CONTACT WITH THE JUNCTION BOX OR OUTLET BOX. <br />CONDUIT SIZE TO BE PER NEC. PVC CONDUIT AND FITTINGS ARE ACCEPTABLE ONLY BELOW SUBBASE MATERIAL <br />OF GROUND BEARING FLOOR SLABS WHERE SUCH USE IS ACCEPTABLE TO THE AUTHORITY HAVING <br />JURISDICTION. <br />CONDUIT SHALL BE ELECTRICAL METALLIC TUBING (EMT), RIGID STEEL (SIZE PER NEC), OR MC CABLE WHERE <br />ALLOWED BY CODE WHERE MC CABLE IS USED, PROPER SECUREMENT AND SUPPORT (AT INTERVALS NOT <br />EXCEEDING 6 FEET) SHALL BE FOLLOWED PER NEC ART. 330. <br />ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOX AND CONDUIT STUB-UP ABOVE CEILING FOR ALL LOW <br />VOLTAGE CABLING. <br />FIELD COORDINATE EXACT LOCATION OF OUTLETS AS DETERMINED BY THE ACTUAL FURNITURE LAY OUT. <br />VERIFY WITH FIXTURE PLAN. <br />COORDINATE WITH OTHER DISCIPLINES FOR ELECTRICAL REQUIREMENTS OF EQUIPMENT NOT SHOWN ON <br />DETAILS (I.E. ROOF-TOP UNITS, UNIT HEATERS, FANS, ETC.). <br />E.C. IS TO VERIFY WITH LOCAL AHJ FOR REQUIREMENT OF EXTERIOR EMERGENCY EGRESS LIGHTING AND <br />ADJUST BID TO INCORPORATE AS NEEDED. <br />A.I.C OF PANELS AND SERVICE ENTRANCE EQUIPMENT IS BASED ON TYPICAL TRANSFORMER SPECIFICATIONS. <br />FIELD VERIFY EXACT UTILITY A.I.C RATING AND MAKE EQUIPMENT ADJUSTMENTS AS REQUIRED IN THE FIELD AT <br />NO EXTRA COST TO OWNER. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY FIELD CHANGES BASED ON <br />UTILITY EQUIPMENT DATA. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />15. <br />16. <br />17. <br />18. <br />19. <br />20. <br />21. <br />22. <br />23. <br />24. <br />25. <br />26. <br />27. <br />28. <br />29. <br />30. <br />MANUAL OTOR STARTER TOGGLE SWITCH WITH THERMAL OVERLOAD <br />PROTECTION - TYPE AND RATING PER EQUIPMENT BEING SERVED. PROVIDE <br />ENCLOSURE WITH LOCK-OUT ACCESSORY. THERMAL OVERLOADS SIZED PER <br />S M <br />EQUIPMENT NAMEPLATE RATING. <br />E-000 <br />ELECTRICAL <br />NOTES, SYMBOLS, & LEGENDS <br />DATA/TELEPHONE OUTLET ROUGH-IN @ +18" AFF UNLESS NOTED OTHERWISE - <br />2-GANG BOX WITH MUD RING, SINGLE GANG COVER PLATE, 1"C. WITH PULL WIRE <br />AND CONDUIT BUSHING TO ABOVE ACCESSIBLE CEILING (QUANTITY OF DATA & <br />TELEPHONE OUTLETS BY OTHERS) <br />TELEPHONE OUTLET ROUGH-IN @ +18" AFF UNLESS NOTED OTHERWISE - 2-GANG <br />BOX WITH MUD RING, SINGLE GANG COVER PLATE, 1"C. WITH PULL WIRE AND <br />CONDUIT BUSHING TO ABOVE ACCESSIBLE CEILING (QUANTITY OF TELEPHONE <br />OUTLETS BY OTHERS) <br />DATA OUTLET ROUGH-IN @ +18" AFF UNLESS NOTED OTHERWISE - 2-GANG BOX <br />WITH MUD RING, SINGLE GANG COVER PLATE, 1"C. WITH PULL WIRE AND <br />CONDUIT BUSHING TO ABOVE ACCESSIBLE CEILING (QUANTITY OF DATA <br />OUTLETS BY OTHERS) <br />WALL MOUNTED LIGHT SWITCH - 'a' = SWITCH DESIGNATION; MOUNT AT +48" TO <br />WALL MOUNTED DIMMER SWITCH - 'a' = SWITCH DESIGNATION; MOUNT AT +48" TO S D <br />WALL MOUNTED OCCUPANCY SENSOR SWITCH - 'a' = SWITCH DESIGNATION; S OS <br />CEILING OCCUPANCY SENSOR - `a' = SWITCH DESIGNATION <br />a <br />a <br />a <br />a <br />S <br />MOUNT AT +48" TO CENTER <br />CEILING MOUNTED DAYLIGHT SENSOR - `a' = SWITCH DESIGNATIONDLa <br />CENTER <br />CENTER <br />WALL MOUNTED OCCUPANCY SENSOR SWITCH WITH DIMMING CAPABILITIES- S OSa <br />'A' = SWITCH DESIGNATION; MOUNT AT +48" TO CENTER <br />MCB <br />MCC <br />MFR <br />MIN <br />MLO <br />MOCP <br />MTD <br />N/A <br />NF <br />NL <br />NRTL <br />NTS <br />OFCI <br />OS <br />P <br />PART <br />PDU <br />PH/Ø <br />PNL <br />PNLBD <br />PROVIDE <br />PT <br />QTY <br />RCPT <br />REF <br />RELO <br />RLA <br />RTU <br />SCCR <br />SD <br />SF <br />SPDT <br />SPST <br />ST <br />SWBD <br />SWGR <br />TBB <br />TBD <br />TGB <br />TL <br />TMGB <br />TX <br />TYP <br />U/F <br />U/G <br />U/S <br />UH <br />UNO <br />UPS <br />VD <br />VFD <br />W <br />W/ <br />WP <br />WR <br />WT <br />XPMAIN CIRCUIT BREAKER <br />MOTOR CONTROL CENTER <br />MANUFACTURER <br />MINIMUM <br />MAIN LUGS ONLY <br />MAXIMUM OVERCURRENT <br />PROTECTION <br />MOUNTED <br />NOT APPLICABLE <br />NON-FUSED <br />NIGHT LIGHT (24HR ON) <br />NATIONALLY RECOGNIZED <br />TESTING LABORATORY <br />(CSA, ETL, NSF, UL) <br />NOT TO SCALE <br />OWNER FURNISHED <br />CONTRACTOR INSTALLED <br />OCCUPANCY SENSOR <br />POLE <br />PARTIAL CIRCUIT <br />POWER DISTRIBUTION UNIT <br />PHASE <br />PANEL <br />PANELBOARD <br />FURNISH AND INSTALL <br />POTENTIAL TRANSFORMER <br />QUANTITY <br />RECEPTACLE <br />REFERENCE <br />RELOCATE <br />RUNNING LOAD AMPS <br />ROOFTOP UNIT <br />SHORT-CIRCUIT CURRENT <br />RATING <br />SMOKE DUCT DETECTOR <br />SQUARE FEET <br />SINGLE-POLE, <br />DOUBLE-THROW <br />SINGLE-POLE, <br />SINGLE-THROW <br />SHUNT TRIP <br />SWITCHBOARD <br />SWITCHGEAR <br />TELECOMMUNICATIONS <br />BONDING BACKBONE <br />TO BE DETERMINED <br />TELECOMMUNICATIONS <br />GROUND BUS BAR <br />TWISTLOCK <br />TELECOMMUNICATIONS <br />MAIN GROUND BUS BAR <br />TRANSFORMER <br />TYPICAL <br />UNDERFLOOR <br />UNDERGROUND <br />UNDERSLAB <br />UNIT HEATER <br />UNLESS NOTED OTHERWISE <br />UNITERRUPTIBLE POWER <br />SUPPLY <br />VOLTAGE DROP <br />VARIABLE FREQUENCY <br />DRIVE <br />WIRE <br />WITH <br />WEATHER PROOF <br />WEATHER RESISTANT <br />WATERTIGHT <br />EXPLOSION PROOF <br />AF <br />AFC <br />AFF <br />AFG <br />AHJ <br />AHU <br />AIC <br />AS <br />AT <br />ATS <br />AV <br />BAS <br />BKR <br />C <br />CAT <br />CATV <br />CCTV <br />CD <br />CKT <br />CODE <br />CT <br />CTR <br />CVD <br />DEMO <br />DPDT <br />DPST <br />(EX) <br />EC <br />EF <br />EM <br />EMS <br />ETR <br />EWC <br />FAAP <br />FACP <br />FCA <br />FCU <br />FF <br />FLA <br />FLR <br />FP <br />GC <br />GEC <br />GES <br />GFR <br />G <br />IG <br />ISC <br />JB/J-BOX <br />LF <br />LRA <br />LTG/LTS <br />MAU <br />MAX <br />MCA <br />AMPERE FRAME SIZE <br />ABOVE FINISHED CEILING <br />ABOVE FINISHED FLOOR <br />ABOVE FINISHED GRADE <br />AUTHORITY HAVING <br />JURISDICTION <br />AIR HANDLING UNIT <br />AMPERE INTERRUPTING <br />CAPACITY <br />AMPERE SWTICH <br />AMPERE TRIP SETTING <br />AUTOMATIC TRANSFER SWITCH <br />AUDIO VISUAL <br />BUILDING AUTOMATION <br />SYSTEM <br />BREAKER <br />CONDUIT <br />CATEGORY <br />CABLE TELEVISION SYSTEM <br />CLOSED CIRCUIT TELEVISION <br />CANDELA <br />CIRCUIT <br />APPLICABLE CODE <br />ADOPTED BY JURISDICTION <br />CURRENT TRANSFORMER <br />CENTER <br />CUMULATIVE VOLTAGE DROP <br />DEMOLITION <br />DOUBLE-POLE, <br />DOUBLE-THROW <br />DOUBLE-POLE, <br />SINGLE-THROW <br />EXISTING <br />ELECTRICAL CONTRACTOR <br />EXHAUST FAN <br />EMERGENCY <br />ENERGY MANAGMENT <br />SYSTEM <br />EXISTING TO REMAIN <br />ELECTRIC WATER COOLER <br />FIRE ALARM ANNUNCIATOR <br />PANEL <br />FIRE ALARM CONTROL PANEL <br />FAULT CURRENT AMPS <br />AVAILABLE <br />FAN COIL UNIT <br />FINISHED FLOOR <br />FULL LOAD AMPS <br />FLOOR <br />FACTORY PROVIDED <br />GENERAL CONTRACTOR <br />GROUNDING ELECTRICAL <br />CONDUCTOR <br />GROUNDING ELECTRODE <br />SYSTEM <br />GROUND FAULT RELAY <br />GROUND <br />ISOLATED GROUND <br />SHORT CIRCUIT CURRENT <br />JUNCTION BOX <br />LINEAR FEET <br />LOCKED ROTOR AMPS <br />LIGHTING/LIGHTS <br />MAKE-UP AIR UNIT <br />MAXIMUM <br />MINIMUM CIRCUIT AMPACITY <br />ABBREVIATIONS LEGEND <br />CLG CEILING <br />03/10/2026