PLUMBING SPECIFICATIONS <br />1.GENERAL <br />THE "ARCHITECTURAL GENERAL CONDITIONS" GOVERN WORK UNDER THIS <br />SECTION. <br />BEFORE SUBMITTING A PROPOSAL, THIS CONTRACTOR SHALL VISIT THE SITE OF <br />THE WORK AND SHALL CAREFULLY EXAMINE THE DRAWINGS AND <br />SPECIFICATIONS. IT IS EXPRESSLY UNDERSTOOD THAT THIS PROPOSAL IS BASED <br />ON THE ABOVE REQUIREMENTS AND THAT IT COVERS EVERYTHING NECESSARY <br />TO DO AND COMPLETE THE WORK. <br />2.INSPECTION AND COOPERATION <br />NO DEVIATION FROM THE DRAWINGS AND /OR SPECIFICATIONS WILL BE ALLOWED <br />WITHOUT PRIOR WRITTEN APPROVAL OF ARCHITECT OR ENGINEER. THIS <br />CONTRACTOR SHALL COOPERATE WITH THE OTHER CONTRACTORS TO ALLOW <br />FOR THE INSTALLATION OF THEIR WORK AS WELL AS HIS OWN. <br />THIS CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK FITTING IN PLACE <br />WITHOUT CONFLICT WITH THE OTHER TRADES, WHERE PROPER PLANNING COULD <br />AVOID INTERFERENCE. <br />3.CODES AND PERMITS <br />NOTHING IN THE DRAWINGS AND/OR SPECIFICATIONS SHALL BE INTERPRETED TO <br />CONFLICT WITH ANY CITY OR PROVINCIAL LAW, REGULATION, CODE, ORDINANCE, <br />RULING, OR FIRE UNDERWRITER'S REQUIREMENT APPLICABLE TO THIS CLASS OF <br />WORK. <br />SHOULD THE DRAWINGS AND/OR SPECIFICATIONS CONFLICT WITH SUCH LAWS <br />OR ORDINANCES, THE CONFLICTING PORTION OF THE WORK SHALL BE INSTALLED <br />STRICTLY IN ACCORDANCE WITH SUCH LAWS AND ORDINANCES WITHOUT EXTRA <br />COST. <br />THIS CONTRACTOR SHALL SECURE AND PAY FOR ALL NECESSARY PERMITS AND <br />INSPECTIONS REQUIRED FOR THIS INSTALLATION OF HIS WORK. <br />4.ACCURACY OF DATA <br />THE INFORMATION GIVEN HEREIN AND ON THE DRAWINGS IS AS EXACT AS COULD <br />BE SECURED, BUT ITS EXTREME ACCURACY IS NOT GUARANTEED. THIS <br />CONTRACTOR SHALL EXAMINE THE LOCATIONS AND VERIFY ALL MEASUREMENTS, <br />DISTANCES, ELEVATIONS AND EXISTING PIPE SIZES BEFORE STARTING THE WORK <br />AS ALL PIPING SYSTEMS SHOWN ON THE DRAWINGS ARE DIAGRAMMATIC ONLY. <br />THIS CONTRACTOR SHALL PROVIDE ALL NECESSARY OFFSETS, RAISED AND <br />DROPS IN PIPING AND DUCTWORK AS REQUIRED BY BUILDING CONDITIONS AT NO <br />ADDITIONAL COST. <br />MECHANICAL DRAWINGS SHALL NOT BE USED FOR GENERAL CONSTRUCTION <br />DIMENSIONS OR FOR TYPE OF MATERIAL USED. FOR EXACT BUILDING LAYOUT, <br />DIMENSIONS AND BUILDING MATERIAL USED, THIS CONTRACTOR SHALL REFER TO <br />THE ARCHITECTURAL DRAWINGS. <br />5.SHOP DRAWINGS <br />SHOP OR INSTALLATION DRAWINGS, FOUNDATION PLANS, EQUIPMENT OR <br />APPARATUS DRAWINGS SHALL BE FURNISHED BY THIS CONTRACTOR. THESE <br />DRAWINGS SHALL BE CLEARLY MARKED INDICATING WHICH ITEMS ARE TO BE <br />SUPPLIED AND SHALL STATE CAPACITIES, SIZES AND GENERAL DESCRIPTION OF <br />ALL EQUIPMENT. ANY CHANGES FROM THE SPECIFIED ITEMS SHALL BE NOTED ON <br />THE SUBMITTALS. <br />SHOP DRAWINGS OF SPECIAL APPARATUS OR EQUIPMENT WHICH IS TO BE <br />FABRICATED INDIVIDUALLY FOR THIS PROJECT AND IS NOT DESCRIBED BY <br />STANDARD MANUFACTURER'S DRAWINGS OR BULLETINS SHALL BE SUBMITTED <br />FOR PROCESSING BEFORE FABRICATION. <br />THESE DRAWINGS SHALL BE SUBMITTED IN A TIMELY MANNER. <br />IT SHALL BE THIS CONTRACTORS RESPONSIBILITY TO MAINTAIN LIAISON WITH ALL <br />PARTIES CONCERNED WITH THE MATERIAL SUBMITTED. THIS CONTRACTOR <br />SHALL NOT PURCHASE ANY EQUIPMENT UNTIL SHOP DRAWINGS HAVE BEEN <br />PROCESSED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY FEES <br />ACCRUED FROM THE RETURN OF FIXTURES PURCHASED PRIOR TO THE REVIEW <br />OF SHOP DRAWINGS AND THAT ARE NOT APPROVED. <br />THIS CONTRACTOR SHALL SUBMIT NO DRAWINGS WITHOUT NOTATION <br />INDICATING DATE OF CONTRACTOR'S REVIEW AND SIGNATURE OF CHECK FOR <br />CONTRACTOR TOGETHER WITH CONTRACTOR'S NAME AND PROJECT <br />IDENTIFICATION. <br />ARCHITECT'S PROCESSING WILL NOT CONSTITUTE A COMPLETE CHECK BUT WILL <br />INDICATE ONLY THAT GENERAL METHOD OF CONSTRUCTION AND DETAILING IS <br />SATISFACTORY. <br />ARCHITECT'S PROCESSING WILL NOT RELIEVE THE CONTRACTOR OF <br />RESPONSIBILITY FOR ERRORS SINCE THIS CONTRACTOR IS SOLELY RESPONSIBLE <br />FOR DIMENSIONS AND DESIGNS OF ADEQUATE CONNECTIONS, DETAILS AND <br />SATISFACTORY CONSTRUCTION OF ALL WORK, AS WELL AS FURNISHING <br />MATERIALS AND WORKMANSHIP REQUIRED BY DRAWINGS AND SPECIFICATIONS <br />WHICH MAY NOT BE INDICATED ON THE SUBMITTALS WHEN APPROVED. <br />CORRECTIONS OR COMMENTS MADE ON THE SHOP DRAWINGS DURING ENGINEER <br />REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE <br />REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. REVIEW OF A SPECIFIC <br />ITEM SHALL NOT INCLUDE REVIEW OF AN ASSEMBLY OF WHICH THE ITEM IS A <br />COMPONENT. THE CONTRACTOR IS RESPONSIBLE FOR: EQUIPMENT VOLTAGES <br />AND DIMENSIONS TO BE CONFIRMED AND CORRELATED WITH ALL DISCIPLINES <br />PRIOR TO PURCHASE; INFORMATION THAT PERTAINS SOLELY TO THE <br />FABRICATION PROCESSES OR TO THE MEANS, METHODS, TECHNIQUES, <br />SEQUENCES AND PROCEDURES OF CONSTRUCTION; COORDINATION OF THE <br />WORK WITH THAT OF ALL OTHER TRADES AND PERFORMING ALL WORK IN A SAFE <br />AND SATISFACTORY MANNER. <br />6.SUBSTITUTIONS OF EQUIPMENT OR MATERIAL <br />THE BRAND NAMES OF EQUIPMENT OR MATERIALS SPECIFIED HEREIN SHALL <br />ESTABLISH QUALITY, CAPACITY, TYPE AND DIMENSIONS TO BE INCLUDED IN THE <br />BASE BID. <br />APPROVAL OF SUBSTITUTED ITEMS WILL BE BASED ON ABILITY AND CAPACITY TO <br />PERFORM FUNCTION SERVED, QUALITY AND AVAILABILITY OF PARTS AND <br />SERVICE, QUALITY OF EQUIPMENT, DELIVERY SCHEDULE, ETC. THE ARCHITECT <br />SHALL REVIEW ALL SUCH REQUESTS BUT RESERVES THE SOLE RIGHT OF <br />JUDGEMENT TO APPROVE OR REJECT THE PROPOSED SUBSTITUTIONS. <br />ACCEPTANCE OR REJECTION OF PROPOSED SUBSTITUTIONS SHALL NOT CAUSE <br />ADDITIONAL COST. ANY CHANGES OF PIPING, DUCTWORK, ELECTRICAL <br />CONTROLS OR INSTALLATION REQUIRED BECAUSE OF THE SUBSTITUTION OR <br />EQUIPMENT SHALL BE PAID FOR BY THIS CONTRACTOR PROPOSING THE <br />SUBSTITUTION. <br />7.ERECTION OF APPARATUS <br />ALL WORK SHALL BE DONE UNDER THE PERSONAL SUPERVISION OF THIS <br />CONTRACTOR WHO SHALL PROVIDE A COMPETENT FOREMAN TO LAY OUT ALL <br />WORK. ALL WORK SHALL BE LAID OUT WITH DUE REGARD FOR THE SPACE <br />REQUIREMENTS OF THE OTHER CONTRACTORS. THIS CONTRACTOR SHALL <br />REPORT ANY CONFLICTS OR DIFFICULTIES IN REGARD TO THE INSTALLATION <br />IMMEDIATELY. <br />WHERE CROWDED LOCATIONS EXIST OR WHERE THERE IS A POSSIBILITY OF <br />CONFLICT BETWEEN TRADES, THIS CONTRACTOR SHALL MAKE COMPOSITE <br />DRAWINGS SHOWING THE EXACT LOCATIONS OF PIPES, DUCT, CONDUIT AND <br />EQUIPMENT. DRAWINGS SHALL BE BASED ON FIELD MEASUREMENTS AND AFTER <br />CONSULTATION AND AGREEMENT BETWEEN THE TRADES, SHALL BE APPROVED <br />BY ARCHITECT AND ENGINEER BEFORE INSTALLATION OF THE WORK. <br />EQUIPMENT OF A TYPE TO REQUIRE REPLACEMENT, SERVICING, ADJUSTING OR <br />MAINTENANCE SHALL BE LOCATED TO ALLOW EASY ACCESS AND SPACE FOR <br />REMOVAL OF INTERNAL ASSEMBLIES, IT REQUIRED. <br />8.EXCAVATION AND BACKFILL <br />THIS CONTRACTOR SHALL DO ALL EXCAVATION REQUIRED TO INSTALL PIPES AND <br />EQUIPMENT SHOWN ON THE PLANS OR REQUIRED FOR PROPER OPERATION. <br />EXCESS EXCAVATION BELOW THE REQUIRED LEVEL SHALL BE BACKFILLED WITH <br />EARTH AND THOROUGHLY TAMPED. UTILITIES SERVICES LINES SHALL BE <br />INSPECTED AND APPROVED BY THE PROPER INSPECTION AUTHORITY BEFORE <br />BACKFILLING. <br />INSTALL PLASTIC PIPE AND FITTINGS IN STRICT ACCORDANCE WITH THE <br />INSTALLATION RECOMMENDATIONS OF THE PIPE AND FITTINGS MANUFACTURER, <br />APPENDIX X1 OF ASTM D2265 (STORAGE AND INSTALLATION PROCEDURES FOR <br />PLASTIC DRAIN, WASTE, AND VENT PIPING) AND FOR BURIED PIPE ASTM D2321 <br />(STANDARD PRACTICE FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC <br />PIPE FOR SEWERS AND OTHER GRAVITY-FLOW APPLICATIONS). SUCH <br />INSTRUCTIONS SHALL INCLUDE BUT ARE NOT LIMITED TO CUTTING, SOLVENT <br />CEMENTING AND PRIMING, JOINTS, CONNECTIONS, TRANSITIONS, ALIGNMENT AND <br />GRADE, TRENCHING, BEDDING, BACKFILL AND COMPACTION, SUPPORTS AND <br />SPACING AND ALLOWANCE FOR THERMAL EXPANSION. <br />CAST IRON PIPING TRENCHING SHALL BE IN ACCORDANCE TO THE CAST IRON <br />SOIL PIPE AND FITTINGS HANDBOOK ISSUED BY THE CAST IRON SOIL PIPE <br />INSTITUTE. <br />THE BOTTOM OF TRENCHES SHALL BE TAMPED HARD AN GRADED TO SECURE <br />THE REQUIRED FALL. ROCK, WHERE ENCOUNTERED SHALL BE EXCAVATED TO A <br />DEPTH OF SIX INCHES (6") BELOW THE BOTTOM OF THE PIPE, AND BEFORE THE <br />PIPE IS LAID, THE SPACE BETWEEN BOTTOM PIPE AND ROCK SURFACE SHALL BE <br />FILLED WITH GRAVEL. IF TRENCHES ARE DEEPER THAN BOTTOM OF FLOORING OR <br />CLOSER THAN THREE FEET (3'0") TO FOOTING THEY MUST BE FILLED WITH <br />COHESIVE SOIL AND COMPACTED TO 95% OF MAXIMUM DENSITY, STANDARD <br />PROCTOR, ASTM D- 698. ALL OTHER EXCAVATIONS UNDER FLOOR SLABS <br />COMPACTED TO 95% STANDARD PROCTOR. <br />WHEN EXCESS DIRT HAS BEEN REMOVED, THE TRENCH SHALL BE BROUGHT TO <br />THE REQUIRED LEVEL WITH SAND AND GRAVEL FIRMLY COMPACTED. <br />TRENCHES AND EXCAVATION SHALL BE BACKFILLED IN 6" LAYERS OF EARTH, <br />FREE FROM CLODS, AND STONES THOROUGHLY TAMPED TO A DEPTH OF 12" <br />ABOVE THE PIPE. AFTER THAT DEPTH HAS BEEN REACHED, BACKFILLING SHALL <br />BE DONE IN 12" LAYERS, THOROUGHLY TAMPED. <br />THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ANY REPAIRS TO ANY DAMAGES <br />OR SAGS TO THE PIPING SYSTEMS THAT OCCUR FROM THE IMPROPER <br />EXCAVATION AND BACKFILL METHODS. <br />9.EQUIPMENT SUPPORTS <br />ANY STRUCTURAL STEEL MEMBERS REQUIRED TO ADAPT THE EQUIPMENT AND <br />PIPING AS FURNISHED BY THIS CONTRACTOR, TO THE BUILDING STEEL OR <br />STRUCTURE, SHALL BE INCLUDED IN THE BID OF THE CONTRACTOR FURNISHING <br />THE EQUIPMENT OR PIPING. HANGING OF ALL EQUIPMENT AND REQUIRED <br />SUPPORTING STEEL AND BRACING SHALL BE FURNISHED BY THE CONTRACTOR <br />WHO SUPPLIES THE EQUIPMENT. <br />10.CUTTING AND PATCHING <br />THIS CONTRACTOR SHALL INCLUDE ALL CUTTING, PATCHING AND PAINTING OF <br />PATCHED AREAS REQUIRED FOR AND RESULTING FROM THE INSTALLATION OF <br />ALL OF THIS CONTRACTOR'S WORK, EXCEPT WHERE NOTED OTHERWISE. <br />ALL OPENINGS AROUND PIPE PENETRATIONS THROUGH SMOKE OR FIRE-RATED <br />FLOORS, CEILINGS OR WALLS SHALL BE SEALED AIRTIGHT WITH MATERIAL <br />HAVING A RATING EQUAL TO THE MATERIAL OF THE WALL, CEILING AND/OR FLOOR <br />PENETRATED. <br />ALL PATCHING SHALL BE NEATLY FINISHED TO THE SATISFACTION OF THE <br />ARCHITECT. <br />11.ACCESS PANELS <br />THIS CONTRACTOR SHALL LOCATE AND FURNISH FOR INSTALLATION BY THE <br />GENERAL CONTRACTOR, ALL ACCESS PANELS AS REQUIRED FOR ACCESS TO <br />VALVES, AND THE PROPER SERVICING OF EQUIPMENT AND LINES INSTALLED <br />UNDER THE CONTRACT. <br />ALL PANELS SHALL BE MILCOR, STYLE "M" FOR MASONRY, "A" FOR ACOUSTICAL <br />TILE AND "K" FOR PLASTER; EXCEPT FOR FIRE-RATED UL 1-1/2 HOUR AND "B" <br />LABEL ACCESS PANELS SHALL BE FURNISHED IN FIRE-RATED WALLS AND <br />CEILINGS AS INDICATED ON THE DRAWINGS. ACCESS DOORS SHALL BE 12" X 12" <br />MINIMUM SIZE FOR VALVES. <br />12.DIELECTRIC UNIONS <br />FOR THE PREVENTION OF ELECTROLYTIC CORROSION AT CONNECTIONS <br />BETWEEN PIPE OF DISSIMILAR METALS OR BETWEEN PIPE AND EQUIPMENT <br />CONNECTIONS OF DISSIMILAR METALS, PROVIDE DIELECTRIC UNIONS OR <br />FLANGES. <br />13.MOTORS, STARTERS AND DISCONNECTS <br />UNLESS SPECIFIED TO BE FURNISHED WITH EQUIPMENT, ALL MOTOR STARTERS <br />AND DISCONNECT SWITCHES SHALL BE FURNISHED AND INSTALLED BY THE <br />ELECTRICAL CONTRACTOR. <br />14.JOINTS AND FITTINGS <br />THREADS ON SCREWED PIPE SHALL BE STANDARD, CLEAN BUTT AND TAPERED. <br />PIPE SHALL BE REAMED OF BURRS AND KEPT CLEAN OF SCALE, DIRT AND <br />SHAVINGS. TREADS SHALL BE MADE WITH FLAKED GRAPHITE AND LUBRICATING <br />OIL OR APPROVED PIPE COMPOUND ON THE MALE THREAD ONLY. <br />COPPER-TO-STEEL AND COPPER-TO-BRASS JOINTS SHALL BE MADE WITH SILVER <br />SOLDER. ALL OTHER COPPER-TO-COPPER JOINTS ABOVE GROUND SHALL BE <br />MADE WITH LEAD FREE SOLDER. COPPER PIPE SHALL BE CUT SQUARE, BURRS <br />REMOVED AND CARE SHALL BE GIVEN TO KEEP THE LINES FREE OF DIRT AND <br />MOISTURE. ALL TUBING AND FITTINGS SHALL BE THOROUGHLY CLEANED. <br />WELDED PIPE SHALL HAVE BUTT WELDED SINGLE "V" TYPE JOINTS FOR WHICH <br />PIPE HAS BEEN BEVELED TO 45 DEGREES. WELD SHALL BE ONE-FOURTH <br />GREATER THICKNESS THAN THE PIPE. CONNECTIONS TO EQUIPMENT, <br />ACCESSORIES, ETC. SHALL BE MADE BY MEANS OF FLANGES AND/OR ADAPTERS. <br />UNIONS SHALL BE PROVIDED AT EACH SCREWED VALVE AND UNIONS OR <br />FLANGES AT EACH EQUIPMENT CONNECTION. <br />15.EXPANSION JOINTS <br />FURNISH AND INSTALL FLEXONICS EXPANSION JOINTS IN PIPING SYSTEM WHERE <br />SHOWN OR NECESSARY FOR EXPANSION AND CONTRACTION. <br />EXPANSION JOINTS IN PIPE 4" AND GREATER SHALL BE THE PACKLESS TYPE WITH <br />STAINLESS STEEL BELLOWS AND HAVE WELDED OR FLANGED END. JOINTS SHALL <br />HAVE TRAVERSE AS INDICATED ON THE PLANS. EXPANSION JOINTS SHALL BE OF <br />THE CONTROLLED FLEXING TYPE. <br />EXPANSION JOINTS IN COPPER PIPE UNDER 4" IN SIZE SHALL BE OF THE <br />COMPENSATOR TYPE CONSTRUCTED OF TWO-PLY STAINLESS STEEL BELLOWS <br />AND CARBON STEEL SHROUDS AND END FITTINGS, INTERNAL GUIDES AND <br />ANTI-TORQUE DEVICES. <br />EXPANSION JOINTS IN STEEL PIPE UNDER 4" IN SIZE SHALL BE OF THE <br />COMPENSATOR TYPE CONSTRUCTED OF TWO-PLY STAINLESS STEEL ELBOWS <br />AND CARBON STEEL SHROUDS AND END FITTINGS, INTERNAL GUIDES AND <br />ANTI-TORQUE DEVICES. <br />PROVIDE GUIDES ON EACH SIDE OF EXPANSION JOINT, AT 4 PIPE DIAMETERS, 14 <br />PIPE DIAMETERS, AND A THIRD GUIDE AS RECOMMENDED BY THE <br />MANUFACTURER. <br />16.PIPE FLEXIBLE CONNECTIONS <br />FLEXIBLE PIPE CONNECTIONS SHALL BE RESISTOFLEX #R6904 OR APPROVED <br />EQUAL FLEXIBLE CONNECTIONS MADE FROM TEFLON. <br />PROVIDE FOR MOVEMENT IN PIPING BY USE OF SWING JOINTS AT CONNECTION <br />OF ALL BRANCHES TO MAINS AND RISERS. ALL BRANCHES FROM MAINS AND <br />RISERS SHALL HAVE 1/4" CLEARANCE BETWEEN PIPE INSULATION AND SLEEVE TO <br />PERMIT PIPE MOVEMENT. <br />17.VALVES <br />THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL VALVES OF ONE <br />MANUFACTURER, FIGURE NUMBER AND TYPE THROUGHOUT THE ENTIRE <br />INSTALLATION OF THE WORK, UNLESS OTHERWISE SPECIFIED. VALVES OF <br />REPUTABLE MANUFACTURERS, SUCH AS HAMMOND, NIBCO, JOMAR AND/OR <br />APOLLO. <br />ALL VALVES SHALL BE BUILT FOR A MINIMUM OF 125 PSIG WORKING PRESSURE. <br />ISOLATION VALVES SHALL BE PROVIDED ON ALL INDIVIDUAL FIXTURES AND <br />FIXTURE GROUPS. <br />CHECK VALVES 2-1/2" AND SMALLER SHALL BE (SCREWED ENDS) OR <br />(SOLDER-JOINT ENDS) SWING-TYPE WITH BRONZE BODY AND BRONZE TRIM. <br />BUTTERFLY VALVES 2" AND LARGER SHALL BE, IRON BODY, CAST-IRON WAFER <br />W/LOCK LEVER. <br />BALL VALVE UP TO 3" IN SIZE SHALL BE BRONZE VALVE WITH CHROME-PLATED <br />BALL AND TEFLON SEAT. <br />GAS LINE COCKS UP TO 4" SHALL BE 1/2 PSI FOR INDOOR APPLIANCE <br />CONNECTIONS SHALL CONFORM TO ANSI Z21.15 AND CSA 9.1, 5 PSI FOR INDOOR <br />SHUTOFF SHALL CONFORM TO CGA 91-002 AND ASME B16.44 <br />HOSE END VALVES SHALL BE GATE VALVES WITH HOSE END NIPPLES <br />18.PIPE SLEEVES AND COLLARS <br />THIS CONTRACTOR SHALL LAY OUT ALL HIS WORK AND SET SLEEVES IN NEW <br />CONSTRUCTION AS CONCRETE FORMS AND WALL ARE ERECTED SO AS TO BE <br />ABLE TO INSTALL HIS WORK WITHOUT CUTTING OR BREAKING OF FLOORS OR <br />WALLS. ALL SLEEVES FOR INSULATED PIPING SHALL BE LARGE ENOUGH TO <br />ALLOW INSULATION TO PASS THROUGH SLEEVE. <br />ALL SLEEVES PASSING THROUGH FLOORS WHICH ARE WATERPROOFED SHALL BE <br />COPPER TUBING SLEEVES EXTENDING 1" ABOVE FINISHED FLOOR. ALL OTHER <br />SLEEVES SHALL BE 24 GAUGE GALVANIZED PIPES AND SLEEVES TO BE <br />THOROUGHLY PACKED WITH WATERPROOF SEALANT AND THE REMAINING SPACE <br />FILLED WITH MASTIC AND MUST BE WATERTIGHT. <br />ALL SLEEVES PASSING THROUGH INNER WALLS SHALL BE STANDARD PIPE <br />THIMBLES EQUAL TO THE THICKNESS OF THE WALL. <br />SPACES BETWEEN PIPES AND SLEEVES THROUGH OUTSIDE WALLS, ABOVE <br />GRADE, SHALL BE CAULKED WITH CAULKING COMPOUND; THOSE BELOW GRADE <br />SHALL BE MADE WATERTIGHT. <br />SPACE AROUND ALL PIPING THROUGH FIRE OR SMOKE RATED PARTITIONS OR <br />FLOORS SHALL BE SEALED AIRTIGHT WITH MATERIALS OR EQUIPMENT AS <br />SPECIFIED UNDER FIRESTOPPING. <br />ALL PIPE PENETRATIONS OF SLABS ON GRADE SHALL BE WRAPPED WITH #15 <br />BUILDING FELTS OR FOAM WRAP. <br />19.HANGERS <br />A.PIPE HANGER AND SUPPORT PRODUCTS INSTALLATION <br />a.VERTICAL PIPING: MSS TYPE 8 OR 42 CLAMPS. <br />b.INDIVIDUAL, STRAIGHT, HORIZONTAL PIPING RUNS: 100 FEET AND <br />LESS: MSS TYPE 1, ADJUSTABLE, STEEL CLEVIS HANGERS. <br />LONGER THAN 100 FEET: MSS TYPE 43, ADJUSTABLE ROLLER <br />HANGERS. LONGER THAN 100 FEET IF INDICATED: MSS TYPE 49, <br />SPRING CUSHION ROLLS. <br />c.MULTIPLE, STRAIGHT, HORIZONTAL PIPING RUNS 100 FEET OR <br />LONGER:MSS TYPE 44, PIPE ROLLS. SUPPORT PIPE ROLLS ON <br />TRAPEZE. <br />d.BASE OF VERTICAL PIPING: MSS TYPE 52, SPRING HANGERS. <br />B.SUPPORT VERTICAL PIPING AND TUBING AT BASE AND AT EACH <br />FLOOR. <br />C.ROD DIAMETER MAY BE REDUCED ONE SIZE FOR DOUBLE-ROD <br />HANGERS, TO A MINIMUM OF 3/8 INCH <br />D.INSTALL HANGERS FOR ALL PIPING PER MSS SP-69, MANUFACTURERS <br />MANUALS AND AS PER HANGER SUPPORT DETAIL ON DRAWINGS <br />E.INSTALL SUPPORTS FOR VERTICAL COPPER TUBING EVERY 10 FEET. <br />F.INSTALL SUPPORTS FOR VERTICAL STEEL PIPING EVERY 15 FEET. <br />G.SUPPORT PIPING AND TUBING NOT LISTED IN THIS ARTICLE <br />ACCORDING TO MSS SP-69 AND MANUFACTURER'S WRITTEN <br />INSTRUCTIONS. <br />20.DAMAGE BY LEAKS <br />THIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO THE GROUNDS, <br />WALKS, ROADS, ALL BUILDING COMPONENTS AND FINISHES, PIPING SYSTEMS, <br />ELECTRICAL SYSTEMS AND THEIR EQUIPMENT AND CONTENT, CAUSED BY LEAKS <br />IN THE PIPING SYSTEMS BEING INSTALLED OR HAVING BEEN INSTALLED HEREIN. <br />ALL REPAIRS WILL BE MADE AT THIS CONTRACTOR'S EXPENSE. <br />21.PIPE MARKERS <br />FURNISH AND INSTALL BRADY #B-350 THIN FILM OR APPROVED EQUAL PIPE <br />MARKERS. MARKERS SHALL BE 1-1/8" HIGH FOR PIPES 3" AND UNDER AND 2-1/4" <br />HIGH FOR PIPES OVER 3". MARKERS SHALL INDICATE TYPE OF SERVICE AND <br />DIRECTION OF FLOW. <br />PIPE MARKERS SHALL BE LOCATED: <br />·AT EQUIPMENT CONNECTIONS <br />·AT ACCESS DOORS <br />·AT BRANCH MAINS <br />·ON ALL ACCESSIBLE PIPE A MAXIMUM OF 75' BETWEEN MARKERS. <br />·AT ALL PENETRATIONS ON EITHER SIDE OF PENETRATION <br />22.FLOOR, WALL AND CEILING PLATES <br />PIPES PASSING THROUGH FLOORS AND FINISHED CEILINGS, FITTED WITH <br />CHROME- PLATED PLATES OR ESCUTCHEONS LARGE ENOUGH TO COMPLETELY <br />CLOSE OPENING AROUND PIPE OR PIPE COVERING AND FLOOR SUPPORT IN THE <br />CASE OF VERTICAL PIPING, SECURELY HELD IN PLACE; CAULK WATERTIGHT <br />AROUND PIPE IN UNFINISHED ROOMS. <br />23.FIRE STOPPING <br />THE PENETRATIONS OF FIRE AND/OR SMOKE RATED WALLS OR FLOORS SHALL BE <br />PROTECTED BY A UL APPROVED MATERIAL TO RETAIN THE INTEGRITY OF THE <br />TIME-RATED CONSTRUCTION BY MAINTAINING AS EFFECTIVE BARRIER AGAINST <br />THE SPREAD OF FLAME, SMOKE AND GASES. IT SHALL BE USED IN ALL DUCT <br />CABLE, CONDUIT AND PIPING PENETRATIONS THROUGH FLOOR SLABS AND <br />TIME-RATED WALLS, AND/OR FLOORS. THE RATING OF THE FIRESTOPPING SHALL <br />EQUAL THE RATING OF THE TIME-RATED ASSEMBLY. <br />FIRESTOPPING MATERIAL SHALL BE 3M FIRE BARRIER SEALING SYSTEM OF <br />APPROVED EQUAL. FIRESTOPPING MATERIAL SHALL CONSTITUTE ONE OR MORE <br />OF THE FOLLOWING PRODUCTS: <br />·CAULK: CP-25 <br />·PUTTY: #303 <br />·WRAP/STRIP: FS195 <br />·COMPOSITE SHEET: CS195 <br />·PENETRATING SEALING SYSTEMS: 7900 SERIES <br />INSTALLATION OF FIRESTOPPING SHALL BE INSTALLED IN ACCORDANCE WITH <br />AND IN STRICT CONFORMITY WITH MANUFACTURER'S PRINTED INSTRUCTIONS AS <br />TO SURFACE PREPARATION, INSTALLATION AND QUALITY CONTROL. AREAS OF <br />WORK SHALL REMAIN ACCESSIBLE UNTIL INSPECTION AND APPROVAL BY THE <br />APPLICABLE CODE AUTHORITIES. <br />ON INSULATED PIPES, THE FIRE-RATING CLASSIFICATION SHALL NOT REQUIRE <br />REMOVAL OF THE INSULATION. <br />QUALITY ASSURANCE: <br />SUBMIT MANUFACTURER'S PRODUCT DATA, LETTER OF CERTIFICATION OR <br />CERTIFIED LABORATORY TEST REPORT THAT THE MATERIAL OR COMBINATION OF <br />MATERIALS MEET THE REQUIREMENTS SPECIFIED IN ASTM E814 AND ARE SO <br />CLASSIFIED IN UL'S BUILDING MATERIALS DIRECTORY. MATERIALS SHALL MEET <br />AND BE ACCEPTABLE FOR USE BY ALL MODEL BUILDING CODES. MATERIALS <br />SHALL MEET THE REQUIREMENTS OF NFPME61- LIFE SAFETY CODE AND NFPA 70 <br />NATIONAL ELECTRICAL CODE. <br />SUBMITTALS: <br />SUBMIT SHOP DRAWINGS, PRODUCT DATA, CERTIFICATES AND MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. SUBMIT MANUFACTURER'S PRODUCT DATA FOR <br />ALL MATERIALS AND PREFABRICATED DEVICES, PROVIDING DESCRIPTIONS <br />SUFFICIENT FOR IDENTIFICATION AT THE JOB SITE. INCLUDE MANUFACTURER'S <br />INSTRUCTIONS FOR INSTALLATION. <br />SUBMIT SHOP DRAWINGS SHOWING PROPOSED MATERIAL, REINFORCEMENT, <br />ANCHORAGE, FASTENINGS, AND METHOD OF INSTALLATION. CONSTRUCTION <br />DETAILS SHALL ACCURATELY REFLECT ACTUAL JOB CONDITIONS. <br />24.CLEANUP AND ADJUSTMENT <br />ALL PARTS WORK LEFT CLEAN: EQUIPMENT, FIXTURES, VALVES, PIPES AND <br />FITTINGS CLEANED OF GREASE AND METAL CUTTINGS. ANY DISCOLORATION OR <br />OTHER DAMAGE TO PORTIONS OF BUILDING, ITS FINISH OR FURNISHING DUE TO <br />THIS CONTRACTORS FAILURE TO PROPERLY CLEAN INTERIOR OF PIPING, <br />REPAIRED AT THIS CONTRACTOR'S EXPENSE. ALL AUTOMATIC CONTROL DEVISES <br />ADJUSTED FOR PROPER OPERATION. ALL SURPLUS MATERIALS AND ANY <br />RUBBISH REMOVED AS IT ACCUMULATES. ALL EQUIPMENT LEFT IN SAFE, PROPER <br />OPERATING CONDITION. <br />DAMAGE TO ANY PORTIONS MUST BE REPAIRED OF THE PART REPLACED BY THIS <br />CONTRACTOR AND ALL PARTS LEFT WITHOUT DENTS, SCRATCHES, THROUGH THE <br />FINISH PAINT, LOOSE PLASTER, STAINS OR OTHER BLEMISHES. <br />25.PIPE TESTING AND START-UP <br />ALL PIPING TO BE TESTED IN ACCORDANCE WITH THE FOLLOWING: <br />·WATER - 100 PSI WATER PRESSURE <br />ALL TESTING MUST HOLD FOR AT LEAST 24 HOURS WITHOUT LOSS OF PRESSURE <br />OR VACUUM. ALL CONCEALED PIPING SHALL BE TESTED IN THE PRESENCE OF <br />THE OWNER'S REPRESENTATIVE PRIOR TO COVERING. BEFORE STARTING ANY <br />SYSTEM, ALL EQUIPMENT SHALL BE LUBRICATED PER MANUFACTURERS <br />REQUIREMENTS BY THIS CONTRACTOR. TEST ENTIRE BUILDING SYSTEMS UNDER <br />FULL LOAD CONDITIONS FOR A PERIOD OF NOT LESS THAT ONE (1) WEEK DURING <br />WHICH TIME THE OPERATING PERSONNEL SHALL BE FULLY INSTRUCTED IN THE <br />OPERATION AND MAINTENANCE OF THE PLANT. AFTER THE PLANT IS IN FULL <br />OPERATION, THIS CONTRACTOR IS TO FURNISH WHATEVER ADDITIONAL SERVICE <br />IS REQUIRED TO RECALIBRATE AND RESET CONTROLS, VALVES, BALANCING <br />COCKS, ETC. TO ENSURE PROPER OPERATION OF THIS SYSTEM. <br />26.TESTING AND BALANCING <br />THIS CONTRACTOR SHALL AT THE TIME OF INSTALLATION ENSURE THAT ALL <br />DEVICES TO COMPLETE TESTING AND BALANCING AS DIRECTED HEREIN ARE <br />FURNISHED AND INSTALLED DURING FABRICATION AND INSTALLATION OF WORK. <br />THIS WORK SHALL BE PERFORMED PRIOR TO TURNOVER TO BUILDING OCCUPANT <br />AND WITH AMPLE TIME TO MAKE ANY NECESSARY REPAIRS OR CHANGES TO <br />ACHIEVE A PROPERLY OPERATING SYSTEM. <br />27.SEISMIC RESTRAINTS ON MECHANICAL EQUIPMENT <br />ALL PLUMBING EQUIPMENT SHALL BE PROVIDED WITH SEISMIC RESTRAINING <br />SERVICES AS REQUIRED BY LOCAL BUILDING CODES. CONTRACTOR SHALL HAVE <br />LOCAL BUILDING OFFICE REVIEW EACH PIECE OF EQUIPMENT WHEN INSTALLED <br />AND THE CONTRACTOR SHALL INSTALL ALL REQUIRED TIE DOWN, ANCHORS, <br />STRAPS OR OTHER DEVICES REQUIRED. <br />28.GUARANTEE <br />THIS CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT, MATERIALS, AND LABOR <br />FURNISHED UNDER THIS CONTRACT TO BE FREE FROM DEFECTS FOR A PERIOD <br />OF ONE (1) YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION AND SHALL <br />REPAIR OR REPLACE ANY EQUIPMENT OR MATERIAL WHICH IS DEFECTIVE OR <br />IMPROPERLY INSTALLED. IN ADDITION, THIS CONTRACTOR SHALL ASSUME FULL <br />RESPONSIBILITY FOR ANY DAMAGE TO THE BUILDINGS AND ITS CONTENTS OR <br />OTHER EQUIPMENT, CAUSED BY DEFECTS OR IMPROPER INSTALLATION OF <br />EQUIPMENT OR MATERIALS INSTALLED UNDER THIS SECTION OF THE <br />SPECIFICATIONS. <br />29.TEMPORARY WATER <br />TEMPORARY WATER SERVICE (IF REQUIRED) TO THE BUILDING SHALL BE <br />PROVIDED BY THIS CONTRACTOR TO THE BUILDING FOR CONSTRUCTION <br />PURPOSES. THIS CONTRACTOR TO MAINTAIN WATER SERVICE AS REQUIRED <br />DURING CONSTRUCTION. <br />30.DOMESTIC WATER SERVICE <br />THIS CONTRACTOR SHALL COORDINATE EXACT AVAILABLE DELIVERY PRESSURE <br />AND PROVIDE ALTERNATE FEE FOR A PRESSURE BOOSTING SYSTEM IF <br />PRESSURE IS LESS THAN 65PSI STATIC. PROVIDE PRESSURE REDUCING VALVE <br />WITH STRAINER IN SERVICE LINE IF REQUIRED BY LOCAL CODES OR PRESSURE IS <br />ABOVE 80 PSI. <br />JOINTS SHALL BE CLEANED AND DEBURRED AS RECOMMENDED BY THE <br />MANUFACTURER AND FEDERAL, STATE, AND LOCAL CODES AND PRESS FITTINGS <br />ARE AN ACCEPTABLE IF ALLOWED BY LOCAL AHJ. WHERE PRESS FITTING S ARE <br />NOT ALLOWED SOLDERED AS LISTED BELOW. FLUX SHALL BE NON-CORROSIVE. <br />VICTAULIC GROUVED COUPLINGS ARE ACCEPTABLE ALTERNATE IF ALLOWED BY <br />LOCAL AHJ. <br />ABOVE GRADE - WHERE FITTINGS ARE SOLDERED BOTH FITTINGS AND TUBING <br />SHALL BE CLEANED AS DESCRIBED ABOVE. UNDER NO CIRCUMSTANCES SHALL <br />DISSIMILAR METALS COME INTO DIRECT CONTACT WITH COPPER TUBING; E.G., <br />GALVANIZED STRAPPING, HANGERS, OR CLAMPS TO SECURE THE TUBING. <br />BELOW GRADE, OR FLOOR SLAB ON EARTH OR STONE FILL - HIGH TEMPERATURE, <br />SOLDER, 1200 DEG. F OR GREATER MELTING POINT. <br />NOTE: WATER PIPE TO BE PROPERLY SECURED AND ALIGNED SO AS NOT TO <br />EXERT VERTICAL OR HORIZONTAL STRESSES ON THE SEATING OF THE MATING <br />(MALE AND FEMALE) SURFACES OF THE UNIONS. <br />MATERIALS - UNDERGROUND: TYPE "K" COPPER TUBE, SOFT TEMPER <br />MATERIALS - ABOVEGROUND: TYPE "L" COPPER TUBE, HARD DRAWN. <br />ALTERNATE MATERIALS - PEX-A PIPING IS AN ACCEPTABLE ALTERNATE IF NOT <br />INSTALLED IN A PLENUM AND APPROVED BY LOCAL CODE OFFICIALS. <br />VIEGA, PROPRESS COPPER ½-INCH THROUGH 4-INCH WITH EPDM SEALING <br />ELEMENT AND/OR VIEGA, PROPRESS 304 OR 316 STAINLESS ½-INCH THROUGH <br />4-INCH WITH EPDM OR FKM SEALING ELEMENT IS ACCEPTABLE IF ALLOWED BY <br />LOCAL CODE <br />31.STERILIZATION OF DOMESTIC WATER SYSTEM <br />THE ENTIRE DOMESTIC WATER DISTRIBUTION SYSTEM SHALL BE FLUSHED CLEAR <br />OF ANY DEBRIS AND THOROUGHLY STERILIZED WITH A SOLUTION CONTAINING <br />NOT LESS THAN 100 PARTS PER MILLION OF AVAILABLE CHLORINE. THE SOLUTION <br />SHALL REMAIN IN THE SYSTEM FOR TWO (2) HOURS DURING WHICH TIME ALL <br />VALVES AND FAUCETS SHALL BE OPENED AND CLOSED SEVERAL TIMES. AFTER <br />STERILIZATION, THE SOLUTION SHALL BE FLUSHED FROM THE SYSTEM WITH <br />CLEAN WATER UNTIL THE RESIDUE CHLORINE CONTENT IS NOT GREATER THAN <br />THE CHLORINE LEVEL OF THE AVAILABLE WATER SUPPLY. <br />STERILIZATION SHALL BE PERFORMED PRIOR TO TURNOVER TO OCCUPANT AS TO <br />NOT ALLOW FOR THE WATER SYSTEM TO REMAIN STAGNANT FOR LONGER THAN <br />24 HOURS. <br />THIS CONTRACTOR SHALL HAVE THE WATER TESTED AND APPROVED BY THE <br />HEALTH DEPARTMENT. <br />32.SANITARY SEWERS <br />THIS CONTRACTOR SHALL CONNECT SANITARY SEWER AS INDICATED ON THE <br />DRAWINGS. VERIFY DIRECTION OF FLOW PRIOR TO ANY ROUGH-IN WORK. <br />EACH PIPE SHALL BE LAID TO THE LINE AND GRADE INDICATED ON THE PLANS <br />AND SUCH A MANNER AS TO FORM A CLOSE CONCENTRIC JOINT WITH THE <br />ADJOINING PIPE AND TO PRESENT OFFSETS IN FLOW LINE. ALL PIPE SHALL BE <br />LAID WITH THE BELLS UPHILL. <br />THE SUB-GRADES SHALL BE KEPT FREE FROM WATER WHILE PIPES ARE BEING <br />LAID. ALL PIPE SHALL BE LAID WITH ENDS ABUTTING AND TRUE TO LINE AND <br />GRADE. THEY SHALL BE FITTED AND MATCHED SO THAT THEY WILL FORM A <br />SEWER WITH A SMOOTH AND UNIFORM INVERT. <br />EACH JOINT SHALL BE CLEANED AS IT IS LAID AND ALL BELLS SHALL BE CLEANED <br />BEFORE PIPES ARE JOINED. <br />PVC SEWER PIPE MAY BE USED IN LIEU OF THAT SPECIFIED ABOVE IF ALLOWED <br />BY LOCAL CODES. <br />ABS AND FOAM CORE PVC ARE NOT ACCEPTABLE MATERIALS. <br />SDR 35 IS NOT ACCEPTABLE FOR UNDER BUILDING USE. <br />33.WASTE, SOIL, DRAIN AND VENT PIPING <br />THE DRAINS, SOIL WASTE AND VENT PIPE AND FITTINGS INCLUDING EXTENSIONS <br />TO SEWERS SHALL BE OF THE SIZES INDICATED ON THE DRAWINGS. PIPE AND <br />FITTINGS TO BE, CYLINDRICAL AND FREE FROM CRACKS OR OTHER DEFECTS. <br />ALL TRENCHES TO BE DUG WITH GRADUAL FALL, THE PIPING TO BE STRAIGHT <br />AND FREE FROM ANY SAGS. <br />THE ARRANGEMENT OF THE SYSTEM SHALL BE AS SHOWN ON THE DRAWINGS <br />AND AS DIRECT AS POSSIBLE, AVOIDING ALL UNNECESSARY OFFSETS. THE <br />STACKS SHALL BE FIRMLY SECURED IN POSITION WITH WROUGHT IRON CLAMPS <br />AT EACH FLOOR. <br />ALL CHANGES IN DIRECTION OF SOIL OR WASTE PIPE SHALL BE MADE BY MEANS <br />OF "Y" BRANCHES AND 1/8 BENDS. NINETY DEGREE SHORT TURN FITTINGS WILL <br />NOT BE PERMITTED EXCEPT TO INDIVIDUAL FIXTURE CONNECTIONS OR WHERE <br />THE FLOW IS FROM THE HORIZONTAL TO THE VERTICAL. <br />SANITARY CLEANOUTS ARE TO BE PROVIDED AT EVERY TURN GREATER THAN 45°, <br />AT INTERVALS OF NO GREATER THAN 50', AT ANY STACK ROUTING BELOW GRADE. <br />NOT ALL CLEANOUTS LOCATIONS MAY BE SHOWN ON THE DRAWING. <br />ALL TRAP SCREWS MUST BE OF FULL SIZE OF PIPE UP TO 4" AND 4" FOR ALL OVER <br />THIS SIZE. CONNECTIONS BETWEEN OUTLETS OF FIXTURES AND SOIL OR WASTE <br />PIPE SHALL BE MADE WITH "Y" BRANCHES TO "TY" BRANCHES WHEREVER <br />POSSIBLE. ALL HORIZONTAL SOIL WASTE AND VENT PIPE SHALL BE GRADED <br />TOWARD OUTLETS AND PIPE NOT BURIED SHALL BE INSTALLED ABOVE THE <br />CEILING OR CLOSE AS POSSIBLE TO THE CONSTRUCTION ABOVE WHERE THERE IS <br />NO CEILING. <br />THE STACKS SHALL BE EXTENDED THROUGH ROOF OF BUILDING TO POINTS NOT <br />LESS THAT 12" ABOVE ROOF. EXTENSIONS THROUGH ROOF SHALL BE MADE <br />WATER- TIGHT BY MEANS OF A LEAD FLASHING OF FOUR POINTS SHEET LEAD <br />SPREAD OVER A DISTANCE OF NOT LESS THAN TWELVE INCHES (12") AROUND <br />PIPE. THIMBLE TO BE SOLDERED TO BASE AND EXTENDED OVER AND TURNED <br />DOWN INTO END OF PIPE IN AN APPROVED MANNER. <br />ALL CLEANOUTS IN FLOORS TO BE JOSAM #58360 OR EQUAL. ADJUSTABLE <br />CLEANOUT WITH BODY TO MATCH THE PIPING MATERIAL, CAST BRASS SCORIATED <br />COVER WITH LETTERS C.O. CAST IN TOP AND CONCEALED BRASS PLUG. <br />CLEANOUTS SHALL BE INSTALLED IN BASE OF EACH STACK. CONCEALED <br />CLEANOUTS SHALL HAVE JOSAM #58600 OR EQUAL. CAST BRASS CHROMIUM <br />PLATED FLAT ACCESS COVER PLATES. <br />ALL JOINTS OF CAST IRON PIPE SHALL BE MADE WITH MANUFACTURERS <br />RECOMMENDED JOINING MATERIAL. AT THE CONTRACTOR'S OPTION HE MAY USE <br />NO-HUB PIPE, FITTINGS, COUPLING AND GASKETS IN LIEU OF CAULKED JOINTS IF <br />APPROVED BY THE LOCAL CODES AND ORDINANCES. <br />IF APPROVED BY THE LOCAL CODES, SCHEDULE 40 PVC PIPE WITH DWV FITTINGS <br />MAY BE USED FOR THE WASTE AND VENT SYSTEM. PVC PIPE AND FITTINGS <br />SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ALL CODES. ENCASEMENT <br />OF PVC PIPES WITHIN RATED SHAFTS SHALL BE THE COST OF THIS CONTRACTOR. <br />SCHEDULE 40 PVC SHALL NOT BE INSTALLED WITHIN A PLENUM. <br />ABS AND FOAM CORE PVC ARE NOT ACCEPTABLE MATERIALS. <br />SDR 35 IS NOT ACCEPTABLE FOR UNDER BUILDING USE. <br />34.VENT FLASHING <br />EACH VENT FLASHING SHALL BE MADE WATER-TIGHT WITH THE ROOF BY PROPER <br />WATER PROOF FLASHING. <br />35.WASTE, VENT AND WATER CONNECTIONS <br />THE MINIMUM SIZE OF WASTE, VENT, AND WATER CONNECTION TO THE <br />INDIVIDUAL FIXTURES SHALL BE AS SHOWN ON DRAWINGS. <br />WHERE FIXTURES ARE GROUPED PIPES SHALL BE INCREASED IN PROPORTION: IN <br />ALL CASES THE SIZE ARRANGEMENTS AND CONNECTIONS OF WATER AND VENT <br />PIPING SHALL NOT BE LESS THAN SIZE OF OPENINGS SPECIFIED FOR FIXTURES <br />AND APPEARING IN FIXTURE LIST. NO WATER PIPE LESS THAN 1/2" SHALL BE <br />INSTALLED IN CONCEALED PLACES SUCH AS IN PARTITIONS OR WALLS ETC. <br />36.PLUMBING FIXTURES AND TRIM <br />PLUMBING FIXTURES SHALL BE FURNISHED AND INSTALLED IN A NEAT AND <br />WORKMANLIKE MANNER WITH PROPER CONNECTIONS TO SUPPLY AND DRAINAGE <br />PIPING. ALL FIXTURES SHALL BE FREE OF FLAWS AND DEFECTS OF ANY SORT IN <br />MATERIAL AND WORKMANSHIP AND SHALL OPERATE PERFECTLY WHEN <br />INSTALLED IN ACCORDANCE WITH MANUFACTURER'S DIRECTION. <br />MATERIALS: FIXTURES SHALL BE THE STANDARD PRODUCT OF ONE OF THE <br />MANUFACTURER'S LISTED IN THE PLUMBING FIXTURE SCHEDULE, OR ANY EQUAL <br />UNIT APPROVED BY THE ENGINEER. <br />INSTALLATION: THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF <br />THE PLUMBING FIXTURES AND ACCESSORIES DURING CONSTRUCTION. HE SHALL <br />REPLACE AT HIS EXPENSE ANY MATERIAL THAT IS MARRED, SCRATCHED, <br />DEFACED AND/OR BROKEN. FIXTURES SHALL BE COVERED WITH BUILDING PAPER <br />AND WOODEN CRATES DURING CONSTRUCTION. <br />CONTRACTOR SHALL COORDINATE EXACT AND PROVIDE ROUGH-IN LOCATIONS <br />WITH FIELD CONDITIONS AND PLANS PRIOR TO ANY WORK. CONTRACTOR SHALL <br />CONNECT ALL FIXTURES TO THE PLUMBING SYSTEM. ALL FIXTURES TO BE <br />INSTALLED TO DIMENSIONS WITH CHROME-PLATED SUPPLIES WITH STOPS. <br />ALL FIXTURES INSTALLED TO DIMENSIONS SHOWN ON THE DRAWINGS. ALL <br />WATER CLOSETS SHALL HAVE CAULKING BETWEEN THE FLOOR AND UNDERSIDE <br />OF THE WATER CLOSET. <br />PLUMBING EQUIPMENT: (REFER TO SCHEDULE ON THE DRAWINGS) <br />37.INSULATION <br />ALL INSULATION SHALL HAVE COMPOSITE (INSULATION, JACKET OR FACINGS AND <br />ADHESIVE USED TO ADHERE THE FACING OR JACKET TO THE INSULATION) FIRE <br />AND SMOKE HAZARD RATINGS AS TESTED BY PROCEDURE ASTM E-84, NFPA 225 <br />UL 723 NOT EXCEEDING: <br />FLAME SPREAD 25 <br />SMOKE DEVELOPED 50 <br />ALL ACCESSORIES SUCH AS ADHESIVES, MASTICS, CEMENTS, TAPES AND CLOTH <br />FOR FITTINGS SHALL HAVE THE SAME COMPONENTS RATINGS AS LISTED ABOVE. <br />INSULATION SHALL BE APPLIED ON CLEAN, DRY SURFACES AND AFTER <br />INSPECTION AND RELEASE FOR INSULATION APPLICATION. ALL INSULATION <br />SHALL BE CONTINUOUS THROUGH WALL AND CEILING OPENINGS AND SLEEVES. <br />INSULATION ON ALL COLD SURFACES WHERE VAPOR BARRIER JACKETS ARE <br />USED, WILL BE APPLIED WITH A CONTINUOUS, UNBROKEN VAPOR SEAL, <br />INCLUDING ALL FITTINGS AND VALVES. ALL INSULATION TO BE INSTALLED IN <br />ACCORDANCE WITH MANUFACTURER'S. FITTINGS SHALL BE FINISHED WITH 1/4" <br />COAT OF INSULATING CEMENT AND CANVAS. <br />INSULATION SCHEDULE: <br />DOMESTIC COLD WATER - 1/2" THICK ARMAFLEX (FLAME SPREAD 25/ SMOKE <br />DEVELOPED 50) <br />DOMESTIC HOT WATER - 1" THICK ARMAFLEX (FLAME SPREAD 25/ SMOKE <br />DEVELOPED 50) <br />DOMESTIC HOT WATER RETURN- 1" THICK ARMAFLEX (FLAME SPREAD 25/ SMOKE <br />DEVELOPED 50) <br />EXPOSED STORM WASTE AND SANITARY WASTE - 1/2" THICK ARMAFLEX (FLAME <br />SPREAD 25/ SMOKE DEVELOPED 50) <br />ALL MATERIALS USED SHALL COMPLY WITH SECTIONS 1712 AND 1713 OF THE UBC. <br />38.NATURAL GAS PIPING SYSTEM <br />ALL PIPING FROM GAS METER TO GAS-FIRED EQUIPMENT SHALL BE FURNISHED <br />AND INSTALLED BY THIS CONTRACTOR. <br />ALL GAS PIPING TO BE IN ACCORDANCE WITH LOCAL CODES, NFPA-54, IFGC AND <br />UPC ALL GAS PIPING SHALL BE INSTALLED IN ACCORDANCE WITH NFPA-54, LOCAL <br />CODES, AND REGULATIONS. <br />ALL GAS PIPING SHALL BE SCHEDULE 40 BLACK OR GALVANIZED STEEL WITH <br />BLACK OR GALVANIZED WITH MALLEABLE SCREWED FITTINGS. USE TEFLON TAPE <br />ON ALL THREADED JOINTS. FITTINGS LARGER THAN TWO INCHES (2") SHALL BE <br />WELDED. PROVIDE UNIONS AND GAS SHUT-OFF VALVES AT EACH PIECE OF GAS <br />FIRED EQUIPMENT OR APPLIANCE. ANY GAS PIPING CONCEALED IN CHASES <br />AND/OR INACCESSIBLE CEILING IS TO BE WELDED WITH WELDED FITTINGS. <br />FLEXIBLE CSST PIPING MATERIAL IS AN ACCEPTABLE ALTERNATE ONLY IF <br />ALLOWED BY LOCAL AHJ AND RESIZED PER MANUFACTURERS SIZING GUIDELINES. <br />ALL FLEXIBLE GAS PIPING SYSTEM COMPONENTS MUST BE: <br />A.1 CSA INTERNATIONAL CERTIFIED CORRUGATED STAINLESS STEEL TUBING <br />(CSST) FLEXIBLE GAS PIPING WITH MECHANICAL ATTACHMENT AUTOFLARE® <br />FITTINGS THAT CONFORM TO THE LATEST ANSI STANDARDS FOR SAFE <br />PERFORMANCE ANSI LC-1 /CSA 6.26. <br />A.2 UNDERWRITERS LABORATORIES CLASSIFICATION LISTED FOR THRU <br />PENETRATION FIRE STOP REQUIREMENTS RATINGS TO INCLUDE ONE, TWO, <br />THREE AND FOUR HOUR TESTS. <br />A.3 LISTED WITH FM (FACTORY MUTUAL) REQUIREMENTS FOR FLAMMABLE GAS <br />PIPING SYSTEMS. FOR SEISMIC RESISTANCE. <br />A.4 TUBING SHALL BE TESTED AND LISTED IN ACCORDANCE WITH ICC LC-1024. <br />FOR RESISTANCE TO ARCING FROM TRANSIENT ENERGY. <br />P-302 <br />PLUMBING DETAILS <br />79 <br />6 <br /> <br />M <br />e <br />r <br />u <br />s <br /> <br />C <br />o <br />u <br />r <br />t <br />St <br />. <br /> <br />L <br />o <br />u <br />i <br />s <br />, <br /> <br />M <br />O <br /> <br />6 <br />3 <br />0 <br />2 <br />6 <br />T <br />6 <br />3 <br />6 <br />. <br />3 <br />4 <br />9 <br />. <br />1 <br />6 <br />0 <br />0 <br />F <br />6 <br />3 <br />6 <br />. <br />3 <br />4 <br />9 <br />. <br />1 <br />7 <br />3 <br />0 <br />16842136571210911141315 <br />84213657 1210911 1413 15 16 <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />a <br />b <br />c <br />d <br />e <br />f <br />g <br />h <br />j <br />k <br />l <br />m <br />n <br />p <br />r <br />s <br />Checked by <br />Drawn by <br />Issue Date <br />Project # <br />Scale <br />Client Approval <br />TI <br /> <br />T <br />E <br />M <br />P <br />L <br />A <br />T <br />E <br /> <br />V <br />1 <br />. <br />0 <br />, <br />10 <br />- <br />1 <br />1 <br />- <br />2 <br />0 <br />1 <br />1 <br />SANTA ANA - SOUTH <br />(#0972) <br />3313 S. BRISTOL ST. <br />SANTA ANA, CA 92704 <br />AS INDICATED <br />07/09/2025 <br />69325-CA03 <br />ISSUED FOR <br />PERMIT <br />#Description Date <br />These drawings/specifications are the property of Oculus Inc. They are <br />furnished as contract documents only. The seal(s) and signature(s) apply <br />only to the document to which they are affixed, and expressly disclaim <br />any responsibility for all other plans, specifications, estimates, reports or <br />other documents or instruments relating to or intended to be used for any <br />part or parts of the architectural or engineering project. Additionally these <br />drawings and seal(s) shall in no way convey or imply any type of warranty <br />or certification relating to the performance of products and materials <br />beyond those provided by their respective manufacturer. <br />© 2025 Oculus Inc. <br />7/9/2025 <br />Matthew R. Case, Engineer <br />CA # M41121