Laserfiche WebLink
WH <br />FD <br />FD <br />UP UP <br />UP <br />UP <br />UP <br />WH <br />FD <br />FD <br />UP UP <br />UP <br />UP <br />UP <br />EXISTING PLANNING & BUILDING TABULATIONS <br />SCOPE OF WORK <br />INTERIOR TENANT IMPROVEMENT: <br />1 -CONVERSION OF PORTION OF EXISTING STORAGE ROOM TO YOUTH ASSEMBLY ROOM AND HALLWAY <br />2 -CONVERSION OF EXISTING HALLWAY / VACANT SPACE TO NURSERY (AND CONVERSION OF EXISTING NURSERY TO STORAGE) <br /> INCLUDING: <br />• CONSTRUCTION OF INTERIOR PARTITIONS & DOORS <br />• MODIFICATION OF EXISTING MECHANICAL & LIGHTING SYSTEMS <br />• INSTALLATION OF (2) NEW ROOFTOP MECHANICAL UNITS <br />NOTE -THIS SCOPE OF WORK HAS BEEN APPROVED UNDER CUP 2022-13. MINOR MODIFICATION TO NURSERY LOCATION IS PROPOSED, AS CLARIFIED BY THE DIAGRAM BELOW, IN ORDER TO MAINTAIN EXISTING <br />LUNCH ROOM IN CURRENT FOOTPRINT. NO CHANGE TO BUILDING ENVELOPE, AREA, OCCUPANCY TYPE OR EXITS -SEE SHEET A0.2 FOR FULL EXITING DIAGRAM. <br />PROJECT DIRECTORY <br />TENANT/CLIENT: <br />COMPASS BIBLE CHURCH <br />CONTACT: BOB DUMONT <br />2909 DAIMLER STREET <br />SANTA ANA, CA 92705 <br />TEL: (714) 290 -2593 <br />EMAIL: BOB@COMPASSCHURCH.ORG <br />OWNER: <br />DAIMLER COMMERCE PARTNERS, LP <br />2 TASMAN SEA <br />NEWPORT COAST, CA 92657 <br />EMAIL: FHUANG39@GMAIL.COM <br />ARCHITECT/ APPLICANT: <br />ELEMENTS ARCHITECTURE, INC. <br />6B LIBERTY, SUITE 100 <br />ALISO VIEJO, CA 92656 <br />CONTACT: SHELLEY MACDONALD <br />TEL: (714) 917-7244 <br />EMAIL: SMACDONALD@ELEMENTSARCH.COM <br />PROJECT:COMPASS BIBLE CHURCH -YOUTH ROOM <br />PROJECT ADDRESS:2909 DAIMLER STREET <br />SANTA ANA, CA 92705 <br />LEGAL DESCRIPTION:THE LAND REFERRED TO HEREIN BELOW IS <br />SITUATED IN THE COUNTY OF ORANGE, STATE OF <br />CALIFORNIA, & IS DESCRIBED AS FOLLOWS: <br />PARCEL 2, IN THE CITY OF SANTA ANA, COUNTY OF <br />ORANGE, STATE OF CALIFORNIA, AS SHOWN ON A MAP FILED <br />IN BOOK 30 PAGE 19 OF PARCEL MAPS, IN THE OFFICE OF <br />THE COUNTY RECORDER OF ORANGE COUNTY, CALIFORNIA. <br />EXCEPTIN THEREFROM, ONE-HALF OF ALL OIL, GAS, <br />MINERALS, HYDROCARBONS & ASSOCIATED SUBSTANCES <br />LYING BELOW A DEPTH OF 500 FT. FROM THE SURFACE <br />OF SAID LAND, W/O THE RIGHT OF SURFACE OR <br />SUBSURFACE ENTRY ABOVE A DEPTH OF 500 FT. FROM <br />THE SURFACE OF SAID LAND, AS RESERVED IN DEED <br />RECORDED AUGUST 9, 1968 IN BOOK 8685 PAGE 900 <br />OF OFFICIAL RECORDS OF ORANGE COUNTY. <br />ACCESSORS PARCEL NO.:430-191-08 <br />FLOOR AREA RATIO:0.39 <br />ZONING DESIGNATION:PROFESSIONAL (P) <br />LAND USE DESIGNATION:PROFESSIONAL & ADMINISTRATIVE OFFICE (PAO) <br />LOT NUMBER(S):LOT 116 <br />LOT AREA:122,099 SF = 2.803 AC. (NO PROPOSED CHANGE) <br />NUMBER OF STORIES:TWO <br />CONSTRUCTION TYPE:TYPE III-B <br />OCCUPANCY CLASSIFICATION:ASSEMBLY (A-3), BUSINESS (B), STORAGE (S-2) <br />*C.B.C. SEC. 508.3 NON-SEPARATED OCCUPANCIES <br />ALLOWABLE ACTUAL <br />BUILDING AREA:28,500 SF 23,538 SF <br />BUILDING HEIGHT:75 FT.+/-22 FT. <br />NO. OF STORIES:THREE TWO <br />ZONING: <br />REQUIRED PROVIDED <br />MAX. STRUCTURE HEIGHT:+35 FT.+/-22 FT. <br />SETBACKS: <br />FRONT:15 FT.54.28 FT. <br />SIDE (STREET ABUTMENT):15 FT.N/A <br />SIDE (INT. SIDE PROP. LINES):5 FT.35.00 FT. <br />REAR (*):50 FT.N/A <br />REAR:10 FT.44.61 FT. <br />(*) MAINTAIN SETBACK IF LOT ABUTTING ON REAR PROPERTY LINE IS A PARCEL USED OR ZONED FOR <br />RESIDENTIAL PURPOSES. <br />CONSTRUCTION TYPE:III-B, FULLY SPRINKLERED (NFPA 13) <br />OCCUPANCY CLASSIFICATION: A3, B, S2 (NON-SEPARATED PER CBC 508.3) <br />EXISTING BUILDING AREAS: <br /> OVERALL BUILDING <br />GROUND FLOOR <br />ADJACENT TENANTS (B OCCUPANCY) = 23,888 SF <br />COMPASS BIBLE CHURCH (A-3 OCCUPANCY) = 19,850 SF <br />TOTAL 43,738 SF <br />SECOND FLOOR <br />COMPASS BIBLE CHURCH (A-3 OCCUPANCY) = 3,688 SF <br />TOTAL 3,688 SF <br /> <br />TOTAL 47,426 SF <br /> TENANT AREA <br />GROUND FLOOR <br />COMPASS BIBLE CHURCH (A-3 OCCUPANCY) = 19,850 SF <br />SECOND FLOOR <br />COMPASS BIBLE CHURCH (A-3 OCCUPANCY) = 3,688 SF <br />TOTAL 23,538 SF <br />HEIGHT (PER CBC TABLE 504.3):ALLOWABLE ACTUAL <br />75' *22'-0 (EXISTING) <br />*USE A OCCUPANCY; MOST RESTRICTIVE <br />STORIES (PER CBC TABLE 504.4): ALLOWABLE ACTUAL <br />3*2 (EXISTING) <br />*USE A-3 OCCUPANCY; MOST RESTRICTIVE <br />ALLOWABLE AREA (PER CBC TABLE 506.2):ALLOWABLE ACTUAL <br />35,625 SF**19,850 SF (GROUND) <br />35,625 SF**3,688 SF (SECOND) <br />71,250 SF **23,538 SF (TOTAL) <br />**Aa = (At + (NS X If) X Sa <br />=(28,500 + (9,500 X 0.75 ) X 2 <br />= 71,250 (35,625 PER FLOOR) <br />VICINITY MAPKEY SITE PLAN <br />PLANNING <br />BUILDING <br />ABBREVIATIONS: <br />GENERAL NOTES <br />1. THE ARCHITECT WILL BE THE INTERPRETER OF THE REQUIREMENTS OF THE CONSTRUCTION <br />DOCUMENTS & THE JUDGE OF THE PERFORMANCE THERE UNDER BY BOTH THE OWNER & THE <br />CONTRACTOR. <br />2. ALL CONSTRUCTION & MATERIALS SHALL BE AS SPECIFIED & AS REQUIRED BY THE CURRENT <br />EDITION OF THE C.B.C., & LOCAL CODES & AUTHORITIES. <br />3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS & SITE CONDITIONS BEFORE STARTING WORK. <br />SHOULD A DISCREPANCY APPEAR IN THE SPECIFICATIONS OR DRAWINGS OR IN THE WORK DONE BY <br />OTHERS FROM THE CONSTRUCTION DOCUMENTS THAT AFFECT ANY WORK, NOTIFY THE ARCHITECT <br />AT ONCE FOR INSTRUCTION ON HOW TO PROCEED. IF THE CONTRACTOR PROCEEDS WITH THE <br />WORK KNOWING OF AN ERROR, INCONSISTENCY, OR OMISSION IN THE CONTRACT DOCUMENTS <br />WITHOUT WRITTEN INSTRUCTIONS FROM THE ARCHITECT, THE CONTRACTOR SHALL MAKE GOOD <br />ANY RESULTING DAMAGE OR DEFECT TO THE SATISFACTION OF THE ARCHITECT. <br />4. SHOULD A CONFLICT OCCUR IN OR BETWEEN DRAWINGS & SPECIFICATIONS, THE SPECIFICATIONS <br />SHOULD TAKE PRECEDENCE, UNLESS A WRITTEN DECISION FROM THE ARCHITECT HAS BEEN <br />OBTAINED WHICH DESCRIBES A CLARIFICATION OR ALTERNATE METHOD &/OR MATERIALS. <br />5. THE CONTRACTOR SHALL CONFINE THEIR OPERATIONS ON THE SITE TO AREAS PERMITTED BY THE <br />OWNER. THE WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LAWS, LOCAL ORDINANCES, <br />PERMITS & THE CONTRACT DOCUMENTS. <br />6. THE JOB SITE SHALL BE MAINTAINED IN A CLEAN, ORDERLY CONDITION FREE OF DEBRIS & LITTER, & <br />SHALL NOT BE UNREASONABLY ENCUMBERED WITH ANY MATERIALS OR EQUIPMENT. EACH SUB- <br />CONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH PHASE OF HIS WORK SHALL REMOVE ALL <br />TRASH & DEBRIS AS A RESULT OF HIS OPERATIONS. <br />7. ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED & PROTECTED TO PREVENT <br />DAMAGE & DETERIORATION UNTIL USE. FAILURE TO PROTECT MATERIALS MAY BE CAUSE <br />REJECTION OF WORK. <br />8. THE CONTRACTOR SHALL DO ALL CUTTING, FITTING, OR PATCHING OF THEIR WORK THAT MAY BE <br />REQUIRED TO MAKE ITS SEVERAL PARTS FIT TOGETHER PROPERLY & SHALL NOT ENDANGER ANY <br />WORK BY CUTTING, EXCAVATING, OR OTHERWISE ALTERING THE WORK OR ANY PART OF IT. ALL <br />PATCHING, REPAIRING & REPLACING OF MATERIALS & SURFACES, CUT OR DAMAGED IN EXECUTION <br />OF WORK SHALL BE DONE WITH APPLICABLE MATERIALS SO THAT SURFACES REPLACED WILL, UPON <br />COMPLETION MATCH SURROUNDING SIMILAR SURFACES. <br />9. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE <br />COMMENCED UNTIL THE SUBMISSION HAS BEEN APPROVED BY THE ARCHITECT. ALL SUCH <br />PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH APPROVED SHOP DRAWINGS & SAMPLES. <br />10. DIMENSIONS: <br />A. ALL DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE. <br />B. ALL DIMENSIONS TO WOOD STUDS ARE TO FACE OF FRAMING, U.O.N. <br />C. ALL DIMENSIONS TO METAL STUDS ARE TO CENTER OF FRAMING, U.O.N. <br />D. CEILING HEIGHT DIMENSIONS ARE FROM THE FINISH FLOOR SLAB TO THE FACE OF CEILING <br />FINISH MATERIAL UNLESS OTHERWISE NOTED. <br />11. SAMPLES OF ALL COLORS & MATERIALS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW & <br />APPROVAL PRIOR TO ORDERING OF PRODUCTS OR COMMENCING RELATED WORK. <br />12. SUBSTITUTIONS OF MATERIALS HAVING LIKE QUALITY TO THOSE SPECIFIED OR NOTED WILL BE <br />CONSIDERED BY THE ARCHITECT. WHERE DESIGN OR DETAIL MODIFICATIONS ARE REQUIRED TO <br />INCORPORATE THESE SUBSTITUTIONS, THE CONTRACTOR SHALL PROVIDE ALL DRAWINGS & DATA <br />TO THE ARCHITECT FOR APPROVAL AS REQUESTED TO VERIFY THE QUALITY & CHARACTER OF THE <br />PRODUCTS & SHOWING THEIR CORRECT INCORPORATION INTO THE PROJECT. THE CONTRACTOR <br />SHALL NOT MAKE CHANGES WITHOUT THE PRIOR WRITTEN APPROVAL OF THE ARCHITECT. <br />13. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO ENSURE ALL SUB-CONTRACTORS HAVE <br />ACCESS TO ALL OF THE VARIOUS DISCIPLINE DRAWINGS TO ACCOMPLISH THE WORK SPECIFIED IN <br />THE CONTRACT DOCUMENTS. <br />14. AT LEAST 50% OF CONSTRUCTION WASTE MATERIALS ARE TO BE RECYCLED. <br />15. PROVIDE ALL NECESSARY BLOCKING, BACKING & FRAMING FOR LIGHT FIXTURES, ELECTRIC UNITS, <br />A/C EQUIPMENT & ALL OTHER ITEMS AS REQUIRED. <br />16. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODE TO ALL CONCEALED SPACES, <br />VOIDS, ATTICS, ETC. VERIFY TYPE REQUIRED WITH ARCHITECT PRIOR TO INSTALLATION. <br />17. WHERE LARGER STUDS OR FURRING IS REQUIRED TO COVER PIPING & CONDUITS, THE LARGER <br />STUD SIZE OR FURRING SHALL EXTEND THE FULL LENGTH OF THE WALL WIDTH & LENGTH WHERE <br />THE FURRING OCCURS. <br />18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE FEES & FOR OBTAINING THE PERMITS FOR THE <br />MECHANICAL, ELECTRICAL & PLUMBING SYSTEMS. THESE SYSTEMS SHALL MEET THE <br />REQUIREMENTS OF ALL LOCAL CODES & ORDINANCES, & THE REQUIREMENTS OF ALL CURRENT <br />STATE & FEDERAL CODES. <br />19. THE CONTRACTOR SHALL PAY FOR THE MAIN ARCHITECTURAL BUILDING PERMIT. THE CONTRACTOR <br />WILL BE REIMBURSED BY THE OWNER FOR THE COST OF THIS PERMIT. ALL OTHER PERMIT FEES <br />SHALL BE PAID BY THE GENERAL CONTRACTOR. <br />20. THE PROJECT CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO MAINTAIN BUILDING <br />SAFEGUARDS, EXITS & FIRE PROTECTION DEVICES. PROTECT ADJACENT PROPERTIES, WORKERS, <br />PEDESTRIANS & OTHER PERSONS DURING EXCAVATION & CONSTRUCTION OPERATIONS. <br />21. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID <br />WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS OR <br />WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE <br />PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. <br />SYMBOLS LEGEND <br />DETAIL IDENTIFICATION <br />BUILDING DETAIL: <br />SHEET WHERE DETAIL LOCATED <br />BUILDING SECTION: <br />SECTION IDENTIFICATION <br />SHEET WHERE SECTION LOCATED <br />GRID LINE HEAD <br />DOOR REFERENCE <br />KEYNOTE REFERENCE <br />REVISION <br />? <br />0 <br />1 <br />A101 <br />SIM <br />1ROOM NUMBERRoom name <br />101 <br />AA-0 FINISH REFERENCE <br />WALL TYPE REFERENCE <br />DETAIL REFERENCE: <br />DETAIL IDENTIFICATION <br />SHEET WHERE DETAIL LOCATED <br />1 <br />A101 <br />? <br />? <br />1 A101 <br /># POUND OR NUMBER <br />@ AT <br />℄CENTERLINE <br />∠ANGLE <br />⌀DIAMETER <br /> --------------------------------------------- <br />A.B. ANCHOR BOLTS <br />A.D. AREA DRAIN <br />A/C AIR-CONDITIONING <br />A.C. ASPHALTIC CONCRETE <br />A.C.T. ACOUSTIC CEILING TILE <br />ACCESS. ACCESSIBLE <br />ACOUS. ACOUSTICAL <br />ADJ. ADJUSTABLE <br />AGGR. AGGREGATE <br />ALUM. ALUMINUM <br />ALT. ALTERNATE <br />ANOD. ANODIZED <br />APPROX. APPROXIMATE <br />ARCH. ARCHITECTURAL <br />ASPH. ASPHALT <br />ASS. ASBESTOS <br />ASSY. ASSEMBLY <br /> --------------------------------------------- <br />B. BASE <br />B.N. BOUNDARY NAILING <br />B.O. BOTTOM OF <br />B.U. BUILT-UP <br />BD. BOARD <br />BETW. BETWEEN <br />BEV. BEVEL <br />BITUM. BITUMINOUS <br />BLDG. BUILDING <br />BLK. BLOCK <br />BLKG. BLOCKING <br />BM. BEAM <br />BOT. BOTTOM <br />BRG. BEARING <br />BSMT. BASEMENT <br /> --------------------------------------------- <br />C.B. CATCH BASIN <br />C.F. CUBIC FOOT <br />C.G. CORNER GUARD <br />C.I.P. CAST-IN-PLACE <br />C.J. CONSTRUCTION JOINT <br />C.I. CAST IRON <br />C.M.U. CONCRETE MASONRY UNIT <br />C.O. CASED OPENING <br />C.Y. CUBIC YARD <br />CAB. CABINET <br />CEM. CEMENT <br />CER. CERAMIC <br />CHAM. CHAMFER(ED) <br />CLG. CEILING <br />CLKG. CAULKING <br />CLO. CLOSET <br />CLR. CLEAR <br />CNTR. COUNTER <br />CO. CLEANOUT <br />COL. COLUMN <br />CONC. CONCRETE <br />CONN. CONNECTION <br />CONSTR. CONSTRUCTION <br />CONT. CONTINUOUS <br />CORR. CORRIDOR <br />CPT. CARPET <br />CSMT. CASEMENT <br />CT. CERAMIC TILE <br />CTR. CENTER <br />CTSK. COUNTERSUNK <br /> --------------------------------------------- <br />D.F. DRINKING FOUNTAIN <br />D.H. DOUBLE HUNG <br />D.L. DEAD LOAD <br />D.S.P. DRY STANDPIPE <br />DBL. DOUBLE <br />DEMO. DEMOLITION <br />DEP. DEPRESS(ED) <br />DEPT. DEPARTMENT <br />DIA. DIAMETER <br />DIM. DIMENSION <br />DISP. DISPENSER <br />DIAG. DIAGONAL <br />DN. DOWN <br />DR. DOOR <br />DS. DOWNSPOUT <br />DTL. DETAIL <br />DWG. DRAWING <br />DWR. DRAWER <br /> --------------------------------------------- <br />E. EAST <br />E.B. EXPANSION BOLT <br />E.F. EACH FACE <br />E.J. EXPANSION JOINT <br />E.P. ELECTRICAL PANELBOARD <br />E.W.C. ELECTRICAL WATER COOLER <br />EA. EACH <br />ELAST. ELASTOMERIC <br />ELECT. ELECTRICAL <br />ELEV. ELEVATION <br />EMER. EMERGENCY <br />ENCL. ENCLOSURE <br />EQ. EQUAL <br />EQUIP. EQUIPMENT <br />EQUIV. EQUIVALENT <br />ESMT. EASEMENT <br />(E) EXISTING <br />EXIST. EXISTING <br />EXP. EXPANSION <br />EXPO. EXPOSED <br />EXT. EXTERIOR <br /> --------------------------------------------- <br />F.A. FIRE ALARM <br />F.D. FLOOR DRAIN <br />F.E. FIRE EXTINGUISHER <br />F.E.C. FIRE EXTINGUISHER CABINET <br />F.F. FINISH FLOOR <br />F.H. FIRE HYDRANT <br />F.H.C. FIRE HOSE CABINET <br />F.N. FIELD NAILING <br />F.O. FACE OF <br />F.O.C. FACE OF CONCRETE <br />F.O.F. FACE OF FINISH <br />F.O.M. FACE OF MASONRY <br />F.O.S. FACE OF STUD <br />FAB. FABRICATE(D)(ION) <br />FDN. FOUNDATION <br />(FF) FACTORY FINISH <br /> -------------------------------------------- <br />FGL. FIBERGLASS <br />FIN. OR F. FINISH <br />FLASH. FLASHING <br />FLR. FLOOR <br />FLUOR. FLUORESCENT <br />FPRF. FIREPROOF <br />FT. FOOT OR FEET <br />FTG. FOOTING <br />FURN. FURNITURE <br />FURR. FURRING <br />FUT. FUTURE <br />FXTR. FIXTURE <br /> -------------------------------------------- <br />G.B. GRAB BAR <br />G.C. GENERAL CONTRACTOR <br />G.I. GALVANIZED IRON <br />GA. GAUGE <br />GALV. GALVANIZED <br />GENL. GENERAL <br />GL. GLASS <br />GLB. GLUED LAMINATED BEAM <br />GND. GROUND <br />GR. GRADE <br />GRVL. GRVL. <br />GT. GROUT <br />GUT. GUTTER <br />GYP. GYPSUM <br />GYP.BD. GYPSUM BOARD <br />GYP.PLAS. GYPSUM PLASTER <br /> --------------------------------------------- <br />H.B. HOSE BIBB <br />H.M. HOLLOW METAL <br />H.V.A.C. HEATING/VENTILATING/AIR-CONDITIONING <br />H.C. HOLLOW CORE <br />HDR. HEADER <br />HDWD. HARDWOOD <br />HDWR. HARDWARE <br />HGR. HANGER <br />HGT. HEIGHT <br />HORIZ. HORIZONTAL <br />HP.LAM. HIGH-PRESSURE LAMINATE <br />HR. HOUR <br />HTR. HEATER <br />HYD. HYDRANT <br />HYDR. HYDRAULIC <br /> --------------------------------------------- <br />I.D. INSIDE DIAMETER (DIM.) <br />IN. INCHES <br />INCAN. INCANDESCENT <br />INCL. INCLUDE(D)(ING) <br />INFO. INFORMATION <br />INSP. INSPECT(ING)(ION) <br />INSTL. INSTALL(ATION) <br />INSUL. INSULATION <br />INT. INTERIOR <br /> --------------------------------------------- <br />JAN. JANITOR <br />JST. JOIST <br />JT. JOINT <br /> --------------------------------------------- <br />K.D. KILN DRIED <br />KIT. KITCHEN <br /> --------------------------------------------- <br />L.F. LINEAR FOOT <br />L.H. LEFT-HAND <br />L.L. LIVE LOAD <br />L.V.T. LUXURY VINYL TILE <br />LAB. LABORATORY <br />LAM. LAMINATE <br />LAV. LAVATORY <br />LB. POUND <br />LBS. POUNDS <br />LDGR. LEDGER <br />LIN. LINEAR <br />LKR. LOCKER <br />LOC. LOCATION <br />LT. LIGHT <br />LT.WT. LIGHT-WEIGHT <br />LTG. LIGHTING <br /> -------------------------------------------- <br />M.B. MACHINE BOLT <br />M.C. MEDICINE CABINET <br />MAS. MASONRY <br />MATL. MATERIAL <br />MAX. MAXIMUM <br />MECH. MECHANICAL <br />MED. MEDIUM <br />MEMB. MEMBRANE <br />MEZZ. MEZZANINE <br />MFR. MANUFACTURER <br />MH. MANHOLE <br />MIN. MINIMUM <br />MIR. MIRROR <br />MISC. MISCELLANEOUS <br />MLWK. MILLWORK <br />MTD. MOUNTED <br />MTG. MOUNTING <br />MTL. METAL <br />MTR. MORTAR <br />MUL. MULLION <br /> -------------------------------------------- <br />(N) NEW <br />N. NORTH <br />N.A. NOT APPLICABLE <br />N.I.C. NOT IN CONTRACT <br />N.T.S. NOT TO SCALE <br />NO. NUMBER <br />NOM. NOMINAL <br /> -------------------------------------------- <br />O.A. OVERALL <br />O.C. ON CENTER <br />O.D. OUTSIDE DIAMETER <br />O/ OVER <br />OBS. OBSCURE <br />OCC. OCCUPANTS <br />OFC. OFFICE <br />OPNG. OPENING <br />OPP. OPPOSITE <br />OVHD. OVERHEAD <br /> --------------------------------------------- <br />P.LAM. PLASTIC LAMINATE <br />P.G. PAINT GRADE <br />P.T. PRESSURE TREATED <br />PAR. PARALLEL <br />PARTN. PARTITION <br />PCF. POUNDS PER CUBIC FOOT <br />PEMB. PRE-ENGINEERED METAL BUILDING <br />PERF. PERFORATE <br />PERP. PERPENDICULAR <br />PLAS. PLASTIC <br />PLUMB. PLUMBING <br />PLF. POUNDS PER LINEAL FOOT <br />PLYWD. PLYWOOD <br />PNL. PANEL <br />PNT. PAINT <br />PR. PAIR <br />PRCST. PRECAST <br />PREFAB. PREFABRICATE(D) <br />PREFIN. PREFINISH(ED) <br />PROP. PROPERTY <br />PSI. POUNDS PER SQUARE INCH <br />PT. POINT <br />PTN. PARTITION <br />PVC. POLYVINYLCHLORIDE <br />PVMT. PAVEMENT <br /> ------------------------------------------- <br />Q.T. QUARRY TILE <br />QTY. QUANTITY <br />QUAL. QUALITY <br /> --------------------------------------------- <br />R. RISER <br />R.D. ROOF DRAIN <br />R.H. RIGHT-HAND <br />R.O. ROUGH OPENING <br />R.W.L. RAIN WATER LEADER <br />RAD. RADIUS <br />RBR. RUBBER <br />REC. RECESSED <br />REF. REFERENCE <br />REFR. REFRIGERATOR <br />REINF. REINFORCE(D) <br />REQ. REQUIRED <br />RESIL. RESILIENT <br />REV. REVISE OR REVISION <br />RFG. ROOFING <br />RGTR. REGISTER <br />RLG. RAILING <br />RM. ROOM <br />RND. ROUND <br /> --------------------------------------------- <br />S. SOUTH <br />S.C. SOLID CORE <br />S.C.W. SOLID CORE WOOD <br />S.S. STAINLESS STEEL <br />S.SK. SERVICE SINK <br />SCHED. SCHEDULE <br />SECT. SECTION <br />SH. SHELF <br />SHR. SHOWER <br />SHT. SHEET <br />SIM. SIMILAR <br />SPEC. SPECIFICATION <br />SQ. SQUARE <br />ST. STAIN <br />STA. STATION <br />STAG. STAGGER(ED) <br />STD. STANDARD <br />STL. STEEL <br />STOR. STORAGE <br />STRUCT. STRUCTURAL <br />SUSP. SUSPENDED <br />SYM. SYMMETRICAL <br />SYS. SYSTEM <br /> --------------------------------------------- <br />T&B TOP & BOTTOM <br />T&G TONGUE & GROOVE <br />T. TEMPERED <br />T.O. TOP OF <br />T.O.C. TOP OF CURB <br />T.O.P. TOP OF PARAPET <br />T.O.PL. TOP OF PLATE <br />T.O.R. TOP OF ROOF <br />T.O.S. TOP OF SLAB <br />T.P. TOP OF PAVEMENT <br />T.S. TUBE STEEL <br />T.V. TELEVISION <br />T.W. TOP OF WALL <br />TEL. TELEPHONE <br />TEMP. TEMPORARY <br />TER. TERRAZZO <br />THK. THICK <br />THRD. THREAD(ED) <br />THRES. THRESHOLD <br />TI. TILE <br />TR. TREAD <br />TYP. TYPICAL <br /> --------------------------------------------- <br />U.O.N. UNLESS OTHERWISE NOTED <br />UNF. UNFINISHED <br />UR. URINAL <br />UTIL. UTILITY <br /> --------------------------------------------- <br />V. VINYL <br />V.C.T. VINYL COMPOSITION TILE <br />V.I.F. VERIFY IN FIELD <br />V.P. VINYL PLANK <br />V.S. VINYL SHEET <br />VERT. VERTICAL <br />VEST. VESTIBULE <br />VNR. VENEER <br /> ------------------------------------------- <br />W/ WITH <br />W/O WITHOUT <br />W. WEST <br />W.C. WATER CLOSET <br />W.GL. WIRE GLASS <br />W.I. WROUGHT IRON <br />W.V. WOOD VENEER <br />W.W.F. WELDED WIRE FABRIC <br />WD. WOOD <br />WDW. WINDOW <br />WF. WIDE FLANGE <br />W.P. WATERPROOF(ING) <br />WSCT. WAINSCOT <br />WT. WEIGHT <br />A <br />B <br />C <br />D <br />E <br />F <br />G <br />H <br />I <br />J <br />K <br />L <br />M <br />N <br />O <br />P <br />Q <br />R <br />S <br />T <br />U <br />V <br />W <br />F <br />APPLICABLE CODES & STANDARDS <br />2025 CALIFORNIA BUILDING CODE (CBC), PART 2, CBSC <br />2025 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, CBSC <br />2025 CALIFORNIA MECHANICAL CODE (CMC), PART 4, CBSC <br />2025 CALIFORNIA PLUMBING CODE (CPC), PART 5, CBSC <br />2025 CALIFORNIA ENERGY CODE, PART 6, CBSC <br />2025 CALIFORNIA FIRE CODE (CFC) <br />2025 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />2025 BUILDING ENERGY EFFICIENCY STANDARDS CODE <br />SANTA ANA MUNICIPAL CODE (SAMC) <br />LIST OF FEDERAL CODES & STANDARDS <br />AMERICANS WITH DISABILITIES ACT (ADA), TITLE II OR TITLE III <br />FOR TITLE II: UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS) <br />OR ADA STANDARDS FOR ACCESSIBLE DESIGN (APPENDIX A OF 28 CFR PART 36) <br />FOR TITLE III: ADA STANDARDS FOR ACCESSIBLE DESIGN (APPENDIX A OF 28 CFR PAR 36) <br />DEFERRED SUBMITTALS <br />THIS PROJECT HAS BEEN PERMITTED WITHOUT REVIEW &/OR APPROVAL OF THE FOLLOWING <br />DEFERRED SUBMITTALS. PLANS APPROVED BY THE CITY SHALL BE OBTAINED FOR EACH DEFERRED <br />ITEM LISTED BELOW PRIOR TO COMMENCING ANY WORK W/IN THE SCOPE OF SUCH DEFERRAL. <br />DEFERRALS MUST BE REVIEWED & ACCEPTED BY THE ARCHITECT OR ENGINEER OF RECORD PRIOR TO <br />SUBMITTING FOR REVIEW W/ THE CITY: <br />1. MODIFICATIONS TO EXISTING FIRE ALARM SYSTEM (IF / AS REQUIRED) <br />2. MODIFICATIONS TO EXISTING FIRE SPRINKLER SYSTEM (IF / AS REQUIRED) <br />FULLY "BUILT-OUT" APPROVED PLAN PER CONDITIONAL USE PERMIT NO. 2022-13 <br />EXISTING / CURRENT PLAN, AS PERMITTED & CONSTRUCTED UNDER #101109480 & 101122238 <br />PROPOSED SCOPE OF WORK UNDER THIS PERMIT <br />YOUTH <br />ADJACENT TENANT (NOT IN SCOPE) <br />NURSERY <br />STRUCTURAL ENGINEER: <br />CORE STRUCTURE <br />201 E. SANDPOINTE AVENUE, SUITE 400 <br />SANTA ANA, CA 92707 <br />CONTACT: AMIR DEIHIMI <br />TEL: (949) 954 - 7242 <br />EMAIL: AMIR@CORESTRUCTURE.COM <br />MECHANICAL / ELECTRICAL: <br />MEP ENERGY SOLUTIONS GROUP, INC. <br />79705 STAR FLOWER TRAIL <br />LA QUINTA, CA 92253 <br />CONTACT: BENNETT HEALY <br />TEL: (562) 439 - 2935 <br />EMAIL: BHEALY@MEPESG.COM <br />A <br />AREA & OCCUPANCY TABULATIONS <br />SCOPE OF WORK (REFERENCE PLAN DIAGRAMS BELOW): <br />1. CONVERT EXISTING STORAGE TO YOUTH ROOM ASSEMBLY ROOM AND HALLWAY: <br />• -2,0001 SF STORAGE (S2) <br />• +1,557 SF YOUTH ROOM (A3) <br />• +444 SF HALLWAY <br />2. CONVERT EXISTING HALLWAY / VACANT SPACE TO NURSERY (AND CONVERT EXISTING <br />NURSERY TO STORAGE AT ROOM #107): <br />• +452 SF NURSERY (A3) <br />• +279 SF STORAGE (S2) <br />• -731 SF HALLWAY <br />PROPOSED TOTAL BUILDING AREA & OCCUPANT LOAD: <br />AREA OCCUPANT LOAD <br />OCCUPANCY TYPE <br />A3 11,699 SF 1584.6 <br />B 3,868 SF 25.8 <br />S2 1,179 SF 3.9 <br />UTILITY / MISC 6,792 SF 0 <br />TOTAL 23,538 SF 1,615 <br />(SEE SHEET A0.2 FOR FULL OCCUPANT LOAD SCHEDULE & EGRESS PLAN) <br />E DYER RD. <br />W MACARTHUR BLVD. <br />E DYER RD. <br />E WARNER AVE. <br />E DEER AVE.DAIMLER ST. <br />PROJECT LOCATION <br />2915 <br />2909 <br />23,538 SF <br />2-STORY <br />A-3 OCCUPANCY <br />COMPASS CHURCH <br />11,944 SF <br />1-STORY <br />B OCCUPANCY <br />WATER TECHNIQUES <br />2917 <br />11,944 SF <br />1-STORY <br />B OCCUPANCY <br />PRIMEGEN BIOTECH <br />EXISTING 3-HOUR FIRE WALL <br />DAIMLER STREET <br />AL <br />T <br />O <br />N <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />3009 3001 2921 <br />2915-2917 <br />29012909 <br />PCM IRVINE <br />CHEERLEADING <br />WATER TECHNIQUES, <br />PRIMEGEN BIOTECHREGAL <br />TECHNOLOGY <br />PARTNERS <br />NKMAX <br />BIOTECH <br />HGST "A WESTERN <br />DIGITAL CO." <br />NORTH <br />A1.1 <br />1 <br />AREA OF WORK <br />COMPASS <br />BIBLE <br />CHURCH <br />PROJECT <br />NORTH <br />TRUE <br />NORTH <br />(E) STAIR <br />ADJACENT TENANT (NOT IN SCOPE) <br />EXISTING AREA TO REMAIN <br />YOUTH <br />STORAGE <br />NURSERY <br />NURSERY <br />LUNCH ROOM <br />OFFICE <br />STORAGE <br />NOTE -NURSERIES WILL BE UTILIZED BY MOMS WITH YOUNG <br />CRYING OR DISRUPTIVE CHILDREN DURING CHURCH SERVICES <br />ONLY. NO CHILDCARE OR DAYCARE SERVICES ARE PROPOSED BY <br />COMPASS BIBLE CHURCH, CURRENTLY OR IN THE FUTURE. <br />A <br />-2,0001 SF STORAGE (S2) <br />+1,557 SF YOUTH ROOM (A3) <br />+444 SF HALLWAY <br />HALLWAY <br />+731 SF NURSERY (A3) <br />-279 SF NURSERY (A3) <br />+ 452 NURSERY (A3) NET <br />+279 SF STORAGE (S2) <br />-731 SF HALLWAY <br />279 SF <br />1,557 SF444 SF <br />731 SF <br />(E) STAIR <br />ADJACENT TENANT (NOT IN SCOPE) <br />STORAGE <br />NURSERY <br />LUNCH ROOM <br />STORAGE <br />YOUTH <br />OFFICE <br />279 SF <br />2,0001 SF <br />HALLWAY <br />731 SF <br />M. STEVEN <br />CAMP <br />C-18,407 <br />JUN. 30, 2027 <br />RENEWAL DATESTATEOFCALIFORNIA <br />LICENSED A RCHITECT <br />PROJECT ARCHITECT: <br />PROJECT MANAGER: <br />DRAWN BY: <br />PROJECT NUMBER: <br />All ideas, designs and plans indicated or represented <br />by these drawings are owned by and are the property <br />of Elements Architecture, Inc. and were created and <br />developed for use in connection with the specified <br />project. None of such ideas, designs, or plans shall <br />be used for any purpose whatsoever without the <br />written permission of Elements Architecture. <br />Elements Architecture, Inc. <br />PROJECT NAME: <br />NO.DESCRIPTION DATE <br />M. Steven Camp, AIA <br />Scott Holland, AIA <br />PROJECT ADDRESS: <br />SHELLEY MACDONALD <br />EA <br />SHELLEY MACDONALD <br />STAMPED/SIGNED: 04/08/2026 <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />7 <br />: <br />5 <br />2 <br />: <br />3 <br />3 <br /> <br />A <br />M <br />21.105 <br />TENANT <br />IMPROVEMENT <br />(PHASE 3) <br />2909 DAIMLER STREET <br />SANTA ANA, CA 92705 <br />A0.1 <br />GENERAL <br />INFORMATION <br />COMPASS BIBLE CHURCH, <br />TUSTIN SANTA ANA <br />SHEET INDEX <br />ARCHITECTURAL <br />A0.1 GENERAL INFORMATION <br />A0.2 CODE ANALYSIS & EGRESS PLAN <br />A1.1 EXISTING SITE PLAN (FOR REFERENCE ONLY) <br />A2.1 DEMOLITION GROUND FLOOR PLAN <br />A2.2 PROPOSED GROUND FLOOR PLAN <br />A2.3 EXISTING SECOND FLOOR PLAN (FOR REFERENCE ONLY) <br />A2.4 ROOF PLAN <br />A4.1 DEMOLITION GROUND FLOOR REFLECTED CEILING PLAN <br />A4.2 PROPOSED GROUND FLOOR REFLECTED CEILING PLAN <br />A5.1 ELEVATIONS & SECTIONS <br />A8.1 DETAILS <br />A9.1 DOOR, WALL & FINISH SCHEDULES <br />A9.2 SPECIFICATIONS <br />A9.3 SPECIFICATIONS <br />ELECTRICAL <br />E0.1 LEGEND, SCHED., GENERAL NOTES & ABBREVIATIONS <br />E0.2 DETAILS & SCHEDULES <br />E0.3 LIGHTING CONTROL DETAILS <br />E2.1 ELECTRICAL FIRST FLOOR LIGHTING PLAN <br />E3.1 ELECTRICAL FIRST FLOOR POWER PLAN <br />E3.3 ELECTRICAL ROOF PLAN <br />E4.1 SINGLE LINE DIAGRAM & PANEL SCHEDULES <br />E5.1 ELECTRICAL SPECIFICATIONS <br />E6.1 TITLE 24 CALCULATIONS <br />MECHANICAL <br />M0.1 LEGEND, SCHED., GENERAL NOTES & ABBREVIATIONS <br />M0.2 MECHANICAL DETAILS <br />M2.0 MECHANICAL DEMO FIRST FLOOR PLAN <br />M2.1 MECHANICAL FIRST FLOOR PLAN <br />M3.1 MECHANICAL ROOF PLAN <br />M4.1 MECHANICAL SPECIFICATIONS <br />M5.1 MECHANICAL TITLE 24 COMPLIANCE <br />(UNDER SEPARATE PERMIT) <br />(UNDER SEPARATE PERMIT) <br />STRUCTURAL <br />S-0.10 GENERAL NOTES & REQUIREMENTS <br />S-0.11 GENERAL NOTES & REQUIREMENTS <br />S-0.20 TYPICAL COLD FORM DETAILS <br />S-1.0 FOUNDATION AND FRAMING PLAN <br />SD1.0 STRUCTURAL DETAILS <br />A PLAN CHECK CORRECTION 04-08-26 <br />A