My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2909 S Daimler St - TI - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Daimler St
>
2909 S Daimler St
>
2909 S Daimler St - TI - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2026 5:00:16 AM
Creation date
6/4/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20188132
40141367
101126784
Full Address
2909 S Daimler St
Street Number
2909
Street Direction
S
Street Name
Daimler
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
WH <br />FD <br />FD <br />UP UP <br />UP <br />UP <br />UP <br />1 98765423 <br />A <br />B <br />C <br />2.01 <br />2.02 <br />2.02 <br />2.03 <br />2.042.04 <br />OFFICENURSERYVOID <br />MEETING ROOM <br />MEETING ROOM <br />MEETING ROOM <br />MEETING ROOM <br />MEETING ROOM <br />MEETING ROOM <br />LUNCH ROOM <br />F.R. <br />MEETING ROOM <br />STORAGE <br />STORAGE <br />STORAGE <br />STORAGE <br />AUDITORIUM <br />RR <br />RR <br />JAN <br />YOUTH <br />EXISTING AREA TO REMAIN <br />2.05 <br />LOBBY <br />201' - 1" (EXISTING OVERALL BUILDING) <br />10 <br />0 <br />' <br /> <br />- <br /> <br />6 <br />" <br /> <br />( <br />E <br />X <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />O <br />V <br />E <br />R <br />A <br />L <br />L <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br />) <br />2.15 <br />1 <br />A5.1 <br />1. ALL UTILITY LINES MUST BE CAPPED AS NECESSARY. <br />2. ANY DEVIATIONS FROM PLAN SHALL BE REPORTED TO ARCHITECT IMMEDIATELY UPON <br />DISCOVERY. <br />3. G.C. SHALL PROVIDE ALL TEMP. SHORING, SCAFFOLDING, BARRICADES, ETC. AS REQ. TO <br />COMPLETE DEMOLITION OF PREMISES. CONTRACTOR SHALL VERIFY AND OBTAIN <br />APPROVAL FROM OWNER OF ALL PROPOSED BARRICADES AND ACCESS LIMITATIONS <br />PRIOR TO COMMENCING WORK. <br />4. PRIOR TO BEGINNING DEMOLITION, G.C. SHALL VERIFY W/ OWNER & LOCAL UTILITY CO., <br />EXACT LOCATIONS OF ALL UTILITIES WHICH MAY RUN THROUGH, ABV. OR BELOW <br />PREMISES. ALL WET AND DRY UTILITY LINES SHALL BE INVESTIGATED AND VERIFIED IN <br />FIELD PRIOR TO START OF WORK. <br />5. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO ACCUMULATE ON-SITE. <br />6. G.C. SHALL BE RESPONSIBLE FOR PROTECTION & SAFE-KEEPING OF ALL ITEMS NOTED ON <br />PLANS AS "EXISTING" OR "EXISTING SHALL REMAIN." ELEMENTS TO REMAIN WHICH ARE <br />DISCOVERED TO BE IN POOR OR DAMAGED CONDITION SHALL BE REPLACED AS REQ. <br />CONTACT ARCHITECT UPON DISCOVERY. <br />7. DEMOLITION SHALL INCLUDE REMOVAL OF ALL NON-STRUCTURAL ITEMS NOT <br />SPECIFICALLY MENTIONED BUT THAT WILL INTERFERE W/ PROPOSED WORK. <br />8. ANY DISCREPANCIES BETWEEN ACTUAL CONDITIONS & THOSE INDICATED IN THESE PLANS <br />REGARDING ITEMS TO REMAIN MUST BE IDENTIFIED & REPORTED TO ARCHITECT <br />IMMEDIATELY. <br />9. SPACES ADJACENT TO AREAS OF WORK SHALL BE PROTECTED PRIOR TO COMMENCING <br />WORK. <br />10. ALL LIGHT FIXTURES TO BE REMOVED INCLUDES REMOVING J-BOXES, CONDUIT, & WIRING, <br />U.N.O. <br />11. ALL UNUSED EQUIP. FEEDERS & CONDUIT SHALL BE WIRED BACK TO SOURCE, U.N.O. <br />12. ANY UNUSED CONDUIT CONCEALED IN FLOOR SHALL BE CAPPED OFF FLUSH W/ GRADE. <br />13. ANY (E) CONDUIT, UTILITY LINES, VENTS, ETC. WHICH ARE CONCEALED IN WALLS TO BE <br />DEMOLISHED SHALL BE LOCATED, PROTECTED & RE-ROUTED AS REQ. <br />14. MAINTAIN CONTINUITY OF CIRCUITS TO DEVICES WHICH ARE TO REMAIN. PROTECT ALL (E) <br />EQUIP., DEVICES, & BUILDING SURFACES THAT ARE TO REMAIN. <br />15. ALL DEVICES SHALL BE FULLY OPERATIONAL AFTER DEMOLITION WORK. PROVIDE (N) <br />CONDUIT & WIRE, OR SPLICE BOXES AS REQ. TO MAINTAIN EQUIP. <br />16. CONTRACTOR SHALL VERIFY LOCATION OF ANY SHEAR WALLS OR LOAD-BEARING WALLS & <br />NOTIFY ARCHITECT PRIOR TO START OF DEMOLITION. <br />17. THESE PLANS REPRESENT THE SCOPE OF WORK AS ACCURATELY AS POSSIBLE; <br />HOWEVER, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY AND INSPECT ALL <br />EXISTING CONDITIONS IN FIELD, AND THEREFORE DETERMINE COMPLETE SCOPE OF <br />WORK, PRIOR TO BID. <br />18. CONTRACTOR SHALL VERIFY WITH OWNER ANY/ALL ITEMS WITHIN OR SURROUNDING <br />SUBJECT BUILDING TO BE PROTECTED AND/OR RELOCATED, AND BE FULLY RESPONSIBLE <br />FOR PROTECTION AND SAFE-KEEPING OF ITEMS. ALL EXISTING ELEMENTS ADJACENT TO <br />AREAS OF WORK MUST BE PROTECTED PRIOR TO COMMENCING WORK. <br />19. ALL FIRE ALARM AND SPRINKLER MODIFICATIONS ARE DESIGN-BUILD. IT IS THE <br />CONTRACTOR'S RESPONSIBILITY TO VERIFY COMPLETE SCOPE OF WORK IN FIELD, PRIOR <br />TO BID. <br />DEMOLITION NOTES <br />M. STEVEN <br />CAMP <br />C-18,407 <br />JUN. 30, 2027 <br />RENEWAL DATESTATEOFCALIFORNIA <br />LICENSED A RCHITECT <br />PROJECT ARCHITECT: <br />PROJECT MANAGER: <br />DRAWN BY: <br />PROJECT NUMBER: <br />All ideas, designs and plans indicated or represented <br />by these drawings are owned by and are the property <br />of Elements Architecture, Inc. and were created and <br />developed for use in connection with the specified <br />project. None of such ideas, designs, or plans shall <br />be used for any purpose whatsoever without the <br />written permission of Elements Architecture. <br />Elements Architecture, Inc. <br />PROJECT NAME: <br />NO.DESCRIPTION DATE <br />M. Steven Camp, AIA <br />Scott Holland, AIA <br />PROJECT ADDRESS: <br />SHELLEY MACDONALD <br />EA <br />SHELLEY MACDONALD <br />STAMPED/SIGNED: 04/08/2026 <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />7 <br />: <br />5 <br />2 <br />: <br />4 <br />2 <br /> <br />A <br />M <br />21.105 <br />TENANT <br />IMPROVEMENT <br />(PHASE 3) <br />2909 DAIMLER STREET <br />SANTA ANA, CA 92705 <br />A2.1 <br />DEMOLITION GROUND <br />FLOOR PLAN <br />COMPASS BIBLE CHURCH, <br />TUSTIN SANTA ANA <br />TRUE <br />NORTH <br />PROJECT <br />NORTH <br />ARCHITECTURAL KEYNOTES <br />## DESCRIPTION <br />2.01 EXISTING DOORS TO BE REMOVED, FRAME TO REMAIN IN-PLACE <br />2.02 EXISTING AREA OF NON-LOAD-BEARING INTERIOR PARTITION TO BE REMOVED FOR <br />NEW OPENING <br />2.03 EXISTING FIRE EXTINGUISHER IN CABINET TO BE RELOCATED <br />2.04 EXISTING FLOORING AND WALL BASE TO BE REMOVED - CLEAN, GRIND DOWN, PATCH <br />AND PREP EXISTING CONC. SLAB TO RECEIVE NEW FINISHES <br />2.05 EXISTING CURTAIN TO BE REMOVED. REMOVE FLOORING AND PREP SLAB AS RQ'D TO <br />RECEIVE NEW PARTITION <br />2.15 EXISTING OVERHEAD DOOR TO BE REMOVED IN COMPLETE <br />1/8" = 1'-0"1DEMOLITION FLOOR PLAN
The URL can be used to link to this page
Your browser does not support the video tag.