Laserfiche WebLink
1 98765423 <br />A <br />B <br />C <br />10 <br />0 <br />' <br /> <br />- <br /> <br />6 <br />" <br /> <br />( <br />E <br />X <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />O <br />V <br />E <br />R <br />A <br />L <br />L <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br />) <br />201' - 1" (EXISTING OVERALL BUILDING) <br />2.13 <br />ADJACENT TENANT (NOT IN SCOPE) <br />2.112.12 <br />EXISTING 3-HOUR FIRE WALL <br />2.14 <br />23.01 <br />13 <br />A8.1 <br />RTU-11 <br />RTU-12 <br />13 <br />A8.1 <br />23.01 <br />(E) RTU-10A <br />RTU-10A <br />23.0323.03 <br />13 <br />A8.1 <br />13 <br />A8.1 <br />13 <br />A8.1 <br />M. STEVEN <br />CAMP <br />C-18,407 <br />JUN. 30, 2027 <br />RENEWAL DATESTATEOFCALIFORNIA <br />LICENSED A RCHITECT <br />PROJECT ARCHITECT: <br />PROJECT MANAGER: <br />DRAWN BY: <br />PROJECT NUMBER: <br />All ideas, designs and plans indicated or represented <br />by these drawings are owned by and are the property <br />of Elements Architecture, Inc. and were created and <br />developed for use in connection with the specified <br />project. None of such ideas, designs, or plans shall <br />be used for any purpose whatsoever without the <br />written permission of Elements Architecture. <br />Elements Architecture, Inc. <br />PROJECT NAME: <br />NO.DESCRIPTION DATE <br />M. Steven Camp, AIA <br />Scott Holland, AIA <br />PROJECT ADDRESS: <br />SHELLEY MACDONALD <br />EA <br />SHELLEY MACDONALD <br />STAMPED/SIGNED: 04/08/2026 <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />7 <br />: <br />5 <br />2 <br />: <br />4 <br />4 <br /> <br />A <br />M <br />21.105 <br />TENANT <br />IMPROVEMENT <br />(PHASE 3) <br />2909 DAIMLER STREET <br />SANTA ANA, CA 92705 <br />A2.4 <br />ROOF PLAN <br />COMPASS BIBLE CHURCH, <br />TUSTIN SANTA ANA <br />ARCHITECTURAL KEYNOTES <br />## DESCRIPTION <br />2.11 EXISTING PARAPET WALL TO REMAIN - PROTECT IN PLACE <br />2.12 EXISTING ROOFING TO REMAIN - PROTECT IN PLACE <br />2.13 EXISTING ROOF LADDER TO REMAIN - PROTECT IN PLACE <br />2.14 EXISTING ROOFTOP MECHANICAL UNIT TO REMAIN - PROTECT IN PLACE, TYP. U.N.O. <br />23.01 NEW ROOFTOP MECHANICAL UNIT - SEE MECHANICAL PLANS FOR COMPLETE SCOPE OF <br />WORK. PATCH, REPAIR AND PROVIDE FLASHING AT EXISTING ROOFING PER DTL - VERIFY <br />ALL EXACT CONDITIONS IN FIELD. <br />23.03 EXISTING ROOFTOP MECHANICAL UNIT TO BE RELOCATED AS SHOWN - SEE MECHANICAL <br />PLANS FOR COMPLETE SCOPE OF WORK. PATCH, REPAIR AND PROVIDE FLASHING AT <br />EXISTING ROOFING PER DTL - VERIFY ALL EXACT CONDITIONS IN FIELD. INFILL, PATCH & <br />REPAIR ROOFING AT EXISTING ABANDONED LOCATION. <br />TRUE <br />NORTH <br />PROJECT <br />NORTH <br />1/8" = 1'-0"1ROOF PLAN <br />NOTE: CONTRACTOR SHALL VERIFY EXISTING ROOF ASSEMBLY IN FIELD, AND ANY <br />AVAILABLE SPECIFICATIONS AND WARRANTY INFORMATION WITH OWNER, PRIOR TO BID. <br />ALL AREAS OF REPAIR AND REPLACEMENT SHALL BE IN ACCORDANCE WITH OWNER'S AND <br />ROOF ASSEMBLY MANUFACTURER'S REQUIREMENTS, AND WARRANTY INSTRUCTIONS AS <br />APPLICABLE.