CEILING & LIGHTING LEGEND <br />EXISTING <br />ILLUMINATED EMERGENCY SIGN - <br />CEILING / WALL MOUNTED <br />PROPOSED <br />SUSPENDED PENDANT LIGHT FIXTURE <br />B.O. FIXTURE = 14'-0" A.F.F.*A <br />1. MEANS OF EGRESS LIGHTING SHALL BE PROVIDED W/ AN <br />ILLUMINATION LEVEL OF NOT LESS THAN 1 FOOT-CANDLE @ THE <br />WALKING SURFACE. (C.B.C. §1008.2) <br />2. WHERE BUILDINGS, ROOMS, OR SPACES REQUIRE TWO OR MORE <br />MEANS OF EGRESS AN EMERGENCY POWER BACKUP SUPPLY SHALL <br />BE PROVIDED FOR A DURATION OF NOT LESS THAN 90 MIN. (C.B.C. § <br />1008.3 THRU §1008.3.4) <br />3. VERIFY ALL EXISTING CONDITIONS IN FIELD UPON DEMOLITION & <br />NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES RELATED <br />TO CEILINGS, STRUCTURE, LIGHTING, OR MECHANICAL <br />INFORMATION. <br />4. DUCTWORK, CONDUIT, PIPE, WIRE, ETC. SHALL BE HIDDEN FROM <br />VIEW & CONCEALED W/IN WALL FRAMING, FLOOR FRAMING, <br />SOFFITS, CHASES, & CEILING PLENUM SPACES WHENEVER <br />POSSIBLE. IF VISIBLE, DUCTWORK, CONDUIT, PIPE, WIRE, ETC. <br />SHALL BE INSTALLED IN A NEAT & ORDERLY MANNER. EXT. FINISH <br />SHALL BE MODIFIED (I.E. PAINT) TO MATCH NEAREST ADJACENT <br />SURFACE. <br />5. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. <br />(C.B.C. §1013.3) <br />6. ELECTRICALLY POWERED EXIT SIGNS SHALL BE LISTED & LABELED <br />IN ACCORDANCE W/ UL 924. (C.B.C. §1013.5) <br />7. EMERGENCY POWER SUPPLY TO ILLUMINATE EXIT SIGNS FOR A <br />DURATION OF NOT LESS THAN 90 MIN. <br />8. IN EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL <br />SYSTEM SHALL AUTOMATICALLY ILLUMINATE AISLES, LOBBY, <br />CORRIDOR, & EXT. DOOR LANDING. EMERGENCY POWER SYSTEM <br />SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 <br />MIN. & SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT <br />OR AN ON-SITE GENERATOR. INITIAL ILLUMINATION AVERAGE OF 1 <br />FOOT-CANDLE & MIN. 0.1 FOOT-CANDLE @ FLOOR LEVEL. (C.B.C. <br />1008.3.4.) <br />9. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE <br />INSTALLATION OF ALL TRADES, INCLUDING DUCTWORK, CONDUIT, <br />UTILITY LINES, AND FIXTURES. AT EXPOSED/OPEN CEILINGS, <br />DUCTWORK SHALL BE MOUNTED ABOVE LIGHT FIXTURES AS HIGH <br />AS POSSIBLE -CONTRACTOR SHALL NOTIFY ARCHITECT <br />IMMEDIATELY OF ANY DISCREPANCIES AS TO MOUNTING HEIGHTS <br />OF ALL EXPOSED COMPONENTS, OR ANY EXISTING UNFORESEEN <br />CONDITIONS PREVENTING COMPLIANCE WITH MOUNTING HEIGHTS <br />PER PLANS <br />10. ALL EXPOSED ELEMENTS SHALL BE PAINTED TO MATCH ADJACENT <br />SURFACE UNLESS NOTED OTHERWISE. ALL EXPOSED REGISTERS <br />SHALL HAVE FINISH TO MATCH ADJACENT SURFACE. <br />NOTES <br />RELOCATED SUSPENDED PENDANT LIGHT FIXTURE - <br />B.O. FIXTURE = 14'-0" A.F.F.*A (R) <br />*VERIFY FINAL EXISTING RELOCATED / NEW <br />PENDANT LOCATIONS WITH EMERGENCY <br />BACKUP REQUIREMENTS -SEE ELECT. <br />ILLUMINATED EMERGENCY SIGN - <br />CEILING / WALL MOUNTED(N) <br />SUSPENDED LINEAR LIGHT FIXTURE <br />B.O. FIXTURE = 12'-0" A.F.F.B <br />1 9765423 <br />A <br />B <br />C <br />10 <br />0 <br />' <br /> <br />- <br /> <br />6 <br />" <br /> <br />( <br />E <br />X <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />O <br />V <br />E <br />R <br />A <br />L <br />L <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br />) <br />201' - 1" (EXISTING OVERALL BUILDING) <br />(OPEN <br />CEILING) <br />NURSERY <br />118 <br />NURSERY <br />117 <br />(E) <br />STORAGE <br />122 <br />YOUTH <br />124 <br />STORAGE <br />125 <br />(E) <br />YOUTH <br />126 <br />EQ 16' - 0"EQ <br />EQ <br />32 <br />' <br /> <br />- <br /> <br />0 <br />" <br />EQ <br />13' - 0" <br />EQ <br />EQ <br />EQ EQ <br />EQ <br />8' <br /> <br />- <br /> <br />0 <br />" <br />8' <br /> <br />- <br /> <br />0 <br />" <br />8' <br /> <br />- <br /> <br />0 <br />" <br />8' <br /> <br />- <br /> <br />0 <br />" <br />EQ <br />(OPEN <br />CEILING) <br />(OPEN <br />CEILING) <br />EQ 8' - 0"8' - 0"EQ <br />EQ <br />EQ <br />HALLWAY <br />123 <br />EXISTING AREA TO REMAIN <br />(N) <br />(N) <br />(N) <br />(E) <br />OFFICE <br />109STORAGE <br />107 <br />(E) VOID <br />108 <br />(E) <br />STORAGE <br />121 <br />(E) <br />AUDITORIUM <br />120 <br />(E) I.T. <br />ROOM <br />110 <br />(E) <br />MEETING <br />ROOM <br />111 <br />(E) <br />MEETING <br />ROOM <br />104 <br />(E) <br />MEETING <br />ROOM <br />103 <br />(E) <br />MEETING <br />ROOM <br />105 <br />(E) <br />HALLWAY <br />102 <br />(E) <br />LUNCH <br />ROOM <br />112 <br />(E) RR <br />115 <br />(E) RR <br />116 <br />(E) <br />MEETING <br />ROOM <br />113(E) <br />LOBBY <br />101 <br />(E) <br />HALLWAY <br />102 <br />(E) <br />LOBBY <br />119 <br />9' - 0" <br />9' - 0" <br />5 <br />A5.1 <br />4 <br />A5.1 <br />3 <br />A5.1 <br />26.01 <br />26.01 <br />A A <br />A (R) <br />A <br />A <br />B <br />B <br />B <br />B <br />B <br />B <br />B <br />B B B <br />5' <br /> <br />- <br /> <br />0 <br />" <br />45° <br />(N) <br />2.072.07 <br />2 <br />A5.1 <br />M. STEVEN <br />CAMP <br />C-18,407 <br />JUN. 30, 2027 <br />RENEWAL DATESTATEOFCALIFORNIA <br />LICENSED A RCHITECT <br />PROJECT ARCHITECT: <br />PROJECT MANAGER: <br />DRAWN BY: <br />PROJECT NUMBER: <br />All ideas, designs and plans indicated or represented <br />by these drawings are owned by and are the property <br />of Elements Architecture, Inc. and were created and <br />developed for use in connection with the specified <br />project. None of such ideas, designs, or plans shall <br />be used for any purpose whatsoever without the <br />written permission of Elements Architecture. <br />Elements Architecture, Inc. <br />PROJECT NAME: <br />NO.DESCRIPTION DATE <br />M. Steven Camp, AIA <br />Scott Holland, AIA <br />PROJECT ADDRESS: <br />SHELLEY MACDONALD <br />EA <br />SHELLEY MACDONALD <br />STAMPED/SIGNED: 04/08/2026 <br />4/ <br />9 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />7 <br />: <br />5 <br />2 <br />: <br />5 <br />1 <br /> <br />A <br />M <br />21.105 <br />TENANT <br />IMPROVEMENT <br />(PHASE 3) <br />2909 DAIMLER STREET <br />SANTA ANA, CA 92705 <br />A4.2 <br />PROPOSED GROUND <br />FLOOR REFLECTED <br />CEILING PLAN <br />COMPASS BIBLE CHURCH, <br />TUSTIN SANTA ANA <br />ARCHITECTURAL KEYNOTES <br />## DESCRIPTION <br />2.07 EXISTING CEILING & LIGHTING TO BE REMOVED FOR INSTALLATION OF NEW FULL-HEIGHT <br />PARTITIONS, AND RE-INSTALLED. COORDINATE EXACT AND COMPLETE SCOPE OF WORK IN <br />FIELD PRIOR TO BID; FIELD VERIFY CONDITION OF TILES PRIOR TO REMOVAL, PATCH, REPAIR <br />AND/OR REPLACE ANY EXISTING DAMAGED TILES/GRID, OR TILES/GRID THAT BECOME <br />DAMAGED DURING REMOVAL AND REINSTALLATION, PROVIDE NEW PERIMETER TRIM <br />THROUGHOUT. VERIFY EXISTING INSULATION ABOVE CEILING - RE-INSTALL; OR IF NONE, <br />PROVIDE NEW ACOUSTIC BATT INSULATION ABOVE CEILINGS. REINSTALL ALL LIGHT <br />FIXTURES AS SHOWN; PROVIDE WIRING / SWITCH MODIFICATIONS - SEE ELECTRICAL PLANS <br />FOR COMPLETE LIGHTING SCOPE. <br />26.01 NEW SUSPENDED LIGHT FIXTURE PER ELECTRICAL PLANS, TYP. <br />1/8" = 1'-0"1PROPOSED FIRST FLOOR REFLECTED CEILING PLAN <br />TRUE <br />NORTH <br />PROJECT <br />NORTH