Laserfiche WebLink
... against wall... freestanding <br />NOTE 1: UNATTACHED ACRYLIC PANELS TO BE FIELD INSTALLED TO CONCEAL FASTENERS. <br />WALL AS IT MAY OCCUR <br />ACRYLIC PNL., <br />THIS FACE UNATTACHED <br />SEE NOTE 1 <br />FLOORING <br />PER FINISH PLAN <br />CONT. CLEAR SEALANT, TYP. <br />EXST. SUBFLOOR <br />SHIM AS REQ'D. <br />ACRYLIC PNL., <br />THIS FACE UNATTACHED <br />SEE NOTE 1 <br />1/2" PLYWD. SUBSTRATE <br />FRAMING, TYP. <br />ACRYLIC PNL., <br />THIS FACE PREATTACHED <br />(FACING DOOR) <br />8X1" WOODSCREW <br />1X CONTINUOUS <br />CLEAT (LOOSE) <br />#8X2" TAPCON <br />@12" O.C. MAX <br />1"X3/4" CONTINUOUS <br />BLOCKING <br />1X CONTINUOUS <br />CLEAT (LOOSE) <br />#8X2" TAPCON <br />@12" O.C. MAX <br />... freestanding <br />NOTE 1: UNATTACHED <br />ACRYLIC PANELS TO BE <br />FIELD INSTALLED TO <br />CONCEAL FASTENERS. <br />ACRYLIC PNL., <br />PREATTACHED TO PLYWD. FRAME <br />SUPPORT TUBE PER 12/A840 <br />2" W x 1/2" THK. PLYWD. <br />STRIP, FASTENED TO TUBE <br />... against wall <br />1/2" Ø ACCESS HOLE <br />ACRYLIC PNL., <br />TOP FACE UNATTACHED <br />SEE NOTE 1 <br />. <br />WALL AS IT MAY OCCUR <br />PROVIDE CLEAR SEALANT <br />AS REQ'D. <br />ACRYLIC PNL., <br />THIS FACE UNATTACHED <br />SEE NOTE 1 <br />1/2" PLYWD. SUBSTRATE <br />FRAMING, TYP. <br />ACRYLIC PNL., <br />THIS FACE UNATTACHED <br />SEE NOTE 1 <br />ACRYLIC PNL., <br />TOP FACE UNATTACHED <br />SEE NOTE 1 <br />ACRYLIC PNL., BOTTOM FACE <br />PREATTACHED TO FRAME <br />. <br />LINE OF FRONT FACE <br />ACRYLIC SEAM#8 x 1" FLATHEAD WD. <br />SCREW, TYP. <br />1/2" Ø ACCESS HOLE <br />SHIM AS REQ'D. <br />SIGNAGE (WHERE OCCURS - <br />REF. ELEVATIONS) <br />DOOR <br />VERTICAL BLADE ELEMENT <br />WHERE OCCURS <br />PER PLAN OR ELEV. <br />HORIZONTAL BLADE ELEMENT <br />AL <br />I <br />G <br />N <br />PROVIDE BACKING AS REQ'D. <br />FABRICATED IN-WALL MTL. <br />BRACKET SUPPORT - <br />3/4" SQ. x 0.083" STL. TUBE @ <br />24" OC MAX. & 2" MAX FROM <br />END OF BACKING PLATE <br />EXST. DOOR & FRAME <br />3/16" THK. STL. BACK PLT. <br />ATTACHED TO WALL w/ <br />#10 x 2" HHSMS @ 12" OC, <br />STAGG. - SHIM AS REQ'D. <br />2 <br />1 <br />/ <br />2 <br />" <br />. <br />9 3/4" LONG x 2" WIDE x 1/2" THK. <br />PLYWD. NAILER STRIP ATTACHED <br />TO TUBE w/ #8 x 1" FHSMS <br />MIN. 2 PER TUBE <br />#8 x 1" FH WD. SCREW, TYP. <br />1/8" THK. ACRYLIC PNL., <br />TOP FACE UNATTACHED <br />TO BE FIELD INSTALLED <br />PREATTACHED ACRYLIC PNL. <br />(FASCIA & BOTTOM) <br />FIN. EDGE <br />PE <br />R <br /> <br />S <br />I <br />G <br />N <br />A <br />G <br />E <br />DW <br />G <br />. <br />. <br />FIN. EDGE <br />CONT. CLR. SEALANT AS REQ'D. <br />PER SIGNAGE <br />AL <br />I <br />G <br />N <br /> <br />E <br />D <br />G <br />E <br /> <br />O <br />F <br /> <br />BL <br />A <br />D <br />E <br /> <br />W <br />I <br />T <br />H <br /> <br />S <br />I <br />G <br />N <br />A <br />G <br />E <br />elevation <br />plan <br />CO <br />N <br />D <br />I <br />T <br />I <br />O <br />N <br />S <br />VA <br />R <br />I <br />E <br />S <br /> <br />P <br />E <br />R <br /> <br />E <br />X <br />I <br />S <br />T <br />I <br />N <br />G <br />2 <br />1 <br />/ <br />2 <br />" <br />PL <br />A <br />N <br />PE <br />R <br />SIGNAGE (WHERE OCCURS - <br />REF. ELEVATIONS) <br />DOOR <br />TOP AND OUTSIDE ACRYLIC <br />TO BE SENT LOOSE <br />F.E. <br />2 1/2" (F.V.) <br />F.E. <br />F.E. <br />F.E. <br />typ. <br />LINE OF BLADE ABOVE <br />VERTICAL BLADE ELEMENT <br />OR <br />A840 <br />08 <br />A840 <br />06 <br />A840 <br />11 <br />07 <br />A840 <br />08 <br />A840 <br />12 <br />A840 <br />SIGNAGE (WHERE OCCURS - <br />REF. ELEVATIONS) <br />DOOR <br />ACCENT PAINT ON WALL IN <br />LIEU OF VERTICAL BLADE <br />ELEMENT WHERE OCCURS - <br />PAINT COLOR TO MATCH <br />ACRYLIC COLOR <br />HORIZONTAL BLADE ELEMENT <br />AL <br />I <br />G <br />N <br />AL <br />I <br />G <br />N <br />EXISTING MILLWORK <br />STEM WALL TO REMAIN <br />EXISTING FLOOR <br />NEW BASE PER SCHED. <br />NEW LAMINATE PER ELEV. <br />NEW SOLID SURFACE <br />COUNTER PER PLAN <br />1/8" <br />CONDITIONS <br />PER EXIST'G.2 1/8" <br />1 <br />1 <br />/ <br />2 <br />" <br />T. <br />O <br />. <br />C <br />O <br />U <br />N <br />T <br />E <br />R <br />MA <br />X <br />. <br /> <br />3 <br />4 <br />" <br /> <br />T <br />O <br />DEMO EXIST'G. BASE, TYP. <br />demo new <br />ALIGN F.O.COUNTER W/ F.O. <br />SOLID SURFACE BEYOND <br />SOLID SURFACE BEYOND <br />(WHERE OCCURS) <br />DEMO EXIST'G. CONDITIONS <br />AS REQ'D. FOR NEW WORK <br />2' <br />- <br />1 <br />0 <br />" <br />EXISTING MILLWORK <br />STEM WALL TO REMAIN <br />EXISTING FLOOR <br />NEW BASE PER SCHED. <br />NEW LAMINATE PER ELEV. <br />NEW SOLID SURFACE <br />PER ELEV. <br />1/8" <br />CONDITIONS <br />PER EXIST'G.2 1/8" <br />11 <br />" <br />T. <br />O <br />. <br />C <br />O <br />U <br />N <br />T <br />E <br />R <br />MA <br />X <br />. <br /> <br />4 <br />0 <br />" <br /> <br />T <br />O <br />DEMO EXIST'G. BASE, TYP. <br />demo <br />DEMO EXIST'G. CONDITIONS <br />AS REQ'D. FOR NEW WORK <br />new <br />ADJUSTABLE FOOT, TYP. <br />BASE PER SCHED., TYP. <br />SOLID SURFACE PER <br />ELEV., TYP. <br />ba <br />40 <br />" <br />1" <br />5" <br />32 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />( <br />R <br />E <br />M <br />O <br />V <br />A <br />B <br />L <br />E <br /> <br />P <br />A <br />N <br />E <br />L <br />) <br />1 <br />1 <br />/ <br />2 <br />" <br />1 <br />1 <br />/ <br />2 <br />" <br />25 <br /> <br />3 <br />/ <br />4 <br />" <br /> <br />( <br />R <br />E <br />M <br />O <br />V <br />A <br />B <br />L <br />E <br /> <br />P <br />A <br />N <br />E <br />L <br />) <br />5" <br />1" <br />33 <br /> <br />1 <br />/ <br />4 <br />" <br /> <br />( <br />3 <br />4 <br />" <br /> <br />M <br />A <br />X <br />) <br />10 <br />" <br />1" <br />10"10" <br />LAMINATE PER ELEV., TYP. <br />SOLID SURFACE BEYOND <br />(WHERE OCCURS) <br />ALL INTERIOR OF <br />RACEWAY TO BE FIRE <br />RATED PLYWOOD, TYP. <br />1/8"1/8"2 1/8"2 1/8" <br />EXISTING FLOOR <br />EXISTING MILLWORK <br />STEM WALL TO REMAIN <br />EXISTING FLOOR <br />NEW BASE PER SCHED. <br />NEW LAMINATE PER ELEV. <br />NEW SOLID SURFACE <br />COUNTER PER PLAN <br />1/8" <br />CONDITIONS <br />PER EXIST'G.2 1/8" <br />1 <br />1 <br />/ <br />2 <br />" <br />T. <br />O <br />. <br />C <br />O <br />U <br />N <br />T <br />E <br />R <br />MA <br />X <br />. <br /> <br />3 <br />4 <br />" <br /> <br />T <br />O <br />DEMO EXIST'G. BASE, TYP. <br />demo new <br />ALIGN F.O.COUNTER W/ F.O. <br />SOLID SURFACE BEYOND <br />SOLID SURFACE BEYOND <br />(WHERE OCCURS) <br />DEMO EXIST'G. CONDITIONS <br />AS REQ'D. FOR NEW WORK <br />DEMO COUNTERTOP AND <br />CONNECTED CASEWORK <br />B.O. CLG. <br />EXST. CEILING TO REMAIN <br />ALUM. HORIZ. LOUVER SLAT <br />PER SCHEDULE - <br />DIRECT ATTACHMENT TO B.O. <br />CLG. PER MFR. INSTRUCTIONS - <br />ALIGN w/ VERT. LOUVER SLAT <br />BELOW PER DETAIL <br />1"4"4"4"4"4"1" <br />PROVIDE CLG. BLOCKING OR <br />BACKING AS REQ'D. <br />1'-10" NOM. <br />CONT. ALUM. SLAT BACK RAIL <br />SUPPORT, FASTENED TO CLG. <br />SIDE SCREW PER MFR. - <br />EXPOSED FASTENER HEAD <br />FACING RECEPTION <br />... section /A84009 <br />(N) BACKING AND <br />ANCHORAGE REF. DETAIL <br />17/A801 <br />EXST. STEM <br />WALL TO REMAIN <br />NEW SOLID <br />SURFACE <br />PER ELEV. <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />T <br />. <br />O <br />. <br /> <br />C <br />O <br />U <br />N <br />T <br />E <br />R <br />T <br />O <br />P <br />... demo <br />DEMO EXST. SURFACES <br />AS REQ'D. & PREP FOR <br />NEW WORK <br />DEMO EXST. SOLID <br />SURFACE COUNTER <br />(WHERE OCCUR) <br />NEW BASE <br />PER SCHED. <br />DEMO EXST. <br />BASE <br />... new work <br />NEW LAMINATE <br />PER ELEV. <br /> <br /> <br />1 <br />1 <br />" <br />DEMO EXST. <br />COUNTERTOP <br />WALL PANELING PER SCHED. <br />ALUM. Z-CLIP - <br />MONARCH MF375 OR EQ. <br />CONT. ALUM. ANGLE TRIM <br />1" x 1/4" x 1/16" THK. <br />PTD. BLACK <br />FINISHED EDGE <br />PNL. CLIP WHERE OCCUR <br />1"1/2" <br />. <br />1/ <br />4 <br />" <br />FACE OF WALL <br />... plan view <br />... section <br />CONT. ALUM. ANGLE TRIM <br />1" x 1/4" x 1/16" THK. <br />PTD. BLACK <br />FINISHED EDGE <br />1/ <br />2 <br />" <br />1" <br />WALL PANELING PER SCHED. <br />1/4" <br />FACE OF WALL <br />OUTLET BOX EXTENDER <br />WALL PANELING PER SCHED. <br />AND ELEVATION <br />ALUM. Z-CLIP - <br />MONARCH MF250 OR EQ. <br />POWER / DATA RECEPTACLE <br />AS IT MAY OCCUR <br />ELEC. OUTLET BOX <br />WALL BACKING AS REQ'D. <br />PER SCHED. <br />COVER PLATE <br />EXST. WALL <br />END CAP w/ MATCHING <br />FINISH - FASTEN PER MFR. <br />BACK RAIL CLOSURE TRIM <br />w/ MATCHING FINISH <br />BACK RAIL CLOSURE w/ <br />MATCHING FINISH <br />SHT. MTL. SCREW CTRD. <br />THRU LOUVER SCREW <br />BOSS <br />HORIZ. ALUM. LOUVER SLAT <br />PER SCHEDULE - <br />DIRECT CLG. ATTACHMENT <br />PER MFR. <br />SHT. MTL. SCREW CTRD. <br />THRU VERT. LOUVER SLAT <br />SCREW BOSS <br />FLR. BRACKET PER MFR. <br />FASTENER AS REQ'D. <br />VERT. ALUM. LOUVER SLAT <br />PER SCHEDULE - <br />FLR. MTD. INSTALLATION <br />PER MFR. <br />CONT. BACK RAIL - <br />DIRECT CLG. ATTACHMENT <br />CLG. FASTENER - <br />PROVIDE CLG. BLOCKING <br />OR BACKING AS REQ'D. <br />CEILING OR SOFFIT <br />FASTENER @ WOOD: <br />1/4" ⌀SOS SCREW W/ 2" EMBED <br />OR 1/4" ⌀TOGGLE BOLT <br />FASTENER @ CONCRETE: <br />1/4" ⌀TAPCON SCREW W/ 1" EMBED <br />OR 1/4" ⌀TITEN-HD W/ 1" EMBED <br />... plan view <br />F.O. DESK / <br />SOLID SURFACE FINISH <br />ALUM. VERT. LOUVER SLAT <br />PER SCHEDULE - <br />FLR. MTD. INSTALLATION <br />PER MFR. INSTRUCTION - <br />ALIGN w/ HORIZ. LOUVER SLAT <br />ABOVE PER DETAIL <br />1'-10" NOM. <br />1"4"4"4"4"4"1" <br />OV <br />E <br />R <br />A <br />L <br />L <br /> <br />D <br />I <br />M <br />. <br />PE <br />R <br /> <br />R <br />C <br />P <br />. <br />.. <br />AL <br />I <br />G <br />N <br /> <br />w <br />/ <br />F. <br />O <br />. <br /> <br />D <br />E <br />S <br />K <br />3/ <br />8 <br />" <br /> <br />G <br />A <br />P <br />F.O. DESK <br />/A84004 <br />... at corner... at wall <br />ACRYLIC PNL., <br />THIS FACE UNATTACHED <br />SEE NOTE 1 <br />1X BLIND CLEAT w/ #8 x 2-1/2" <br />FHSMS @ 24" OC MAX. <br />ACRYLIC PNL., <br />THIS FACE UNATTACHED <br />SEE NOTE 1 <br />#8 x 1-1/4" FH WD. SCREW <br />@ 24" OC MAX., TYP. <br />EXST. DOOR & FRAME <br />CONT. CLEAR SEALANT, <br />TYP. BOTH SIDES <br />2 1/2". <br />1/2" PLYWD. SUBSTRATE <br />FRAMING, TYP. <br />PROVIDE <br />BACKING <br />AS REQ'D. <br />LINE OF BLADE ABOVE <br />2 1/2". <br />NOTE 1: UNATTACHED ACRYLIC PANELS TO BE FIELD INSTALLED TO CONCEAL FASTENERS. <br />ACRYLIC PNL., <br />THIS FACE UNATTACHED <br />SEE NOTE 1 <br />. <br />. <br />SHIM AS REQ'D. <br />CONT. CLEAR SEALANT <br />1X BLIND CLEAT w/ #8 x <br />2-1/2" FHSMS @ 24" OC <br />MAX. <br />PREATTACHED ACRYLIC <br />PNL. PER FINISH SCHED. <br />. <br />0 5' <br />GRAPHIC SCALES: <br />Issue Date <br />1/16" = 1'-0" <br />50' <br />1/8" = 1'-0" 1/4" = 1'-0" 1/2" = 1'-0" 3/4" = 1'-0" 1" = 1'-0" 1-1/2" = 1'-0" 3" = 1'-0" <br />0 5'25'0 1'12'0 1'6'0 4'0 3'1'0 2'0 1' <br />Chckd By <br />Drwn By <br />Scale <br />Building ID: <br />KP Proj. No. <br />Permit No. <br />Sheet <br />SheetsOf <br />Sheet Title <br />Project <br />Facility <br />This document is the property of the Owner and is <br />Project Architect Approval: <br />Architect/Engineer Of Record: <br />IF THIS SHEET IS NOT 30"x42" , IT IS <br />A REDUCED PRINT - SCALE ACCORDINGLY <br />National Facilities Services <br />Post Office Box 12916 <br />Oakland California 94604 <br />not to be used without owner's written permission. <br />Floor Lev: Section: <br />Revisions <br />By Appr. <br />HGW Proj. No. <br />© <br />H <br />G <br />W <br /> <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />, <br /> <br />a <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br /> <br /> <br />A <br />n <br />y <br /> <br />u <br />s <br />e <br /> <br />w <br />i <br />t <br />ho <br />u <br />t <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />i <br />s <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br />l <br />y <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br /> <br /> <br />P <br />l <br />o <br />t <br />t <br />e <br />d <br />1955 Bacon Street. San Diego, CA 92107 <br />Office 619 523 8487 <br />www.hgwarchitecture.com <br />KAISER PERMANENTE <br />BUILDINGS ON BRAND <br />As indicated <br />2/ <br />2 <br />5 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />1 <br />0 <br />: <br />0 <br />8 <br />: <br />2 <br />8 <br /> <br />A <br />M <br />02/25/2026 <br />Checker <br />Author <br />CAP030942 <br />A840 <br />TYPICAL INTERIOR DETAILS <br />3401 South Harbor Boulevard, <br />Santa Ana, CA 92704 <br />pl <br />a <br />n <br /> <br />c <br />h <br />e <br />c <br />k <br /> <br />r <br />e <br />s <br />u <br />b <br />m <br />i <br />t <br />t <br />a <br />l <br />2441 <br />EXTERIOR SIGNAGE - HARBOR-MAC <br />ARTHUR <br />3" = 1'-0"11 vertical blade element @ sill <br />3" = 1'-0"06 typical blade corner detail <br />1/2" = 1'-0"02 typical blade axon <br />3" = 1'-0"12 horizontal blade element <br />3/8" = 1'-0"01 typical blade plan and elevation <br />1/2" = 1'-0"03 typical blade axon with painted vertical <br />1 1/2" = 1'-0"16 anchor desk - transaction counter remodel detail <br />1 1/2" = 1'-0"17 anchor desk - solid surface remodel detail <br />1 1/2" = 1'-0"18 anchor desk - new construction detail <br />1 1/2" = 1'-0"14 anchor desk - transaction counter remodel <br />1 1/2" = 1'-0"04 louver slat @ ceiling <br />1 1/2" = 1'-0"19 anchor desk solid surface remodel <br />6" = 1'-0"15 wall panel edge <br />6" = 1'-0"20 receptacle thru wall panel <br />3" = 1'-0"05 louver slat installation <br />1 1/2" = 1'-0"09 vertical louver slat <br />3" = 1'-0"07 vertical blade element <br />No. Revisions Date <br />1 SD 06/05/2025 <br />2 DD 07/03/2025 <br />3 90% CD 08/15/2025 <br />4 Plan Check Submittal 09/19/2025 <br />12 Plan Check Resubmittal 02/25/2026