ELECTRICAL ABBREVIATION KEY <br />AFF ABOVE FINISHED FLOOR <br />C CONDUIT <br />CO CONDUIT AND BOX ROUGH-IN ONLY (ROUGH-IN ONLY) <br />GFI GROUND FAULT INTERRUPTER <br />ABBR:DESCRIPTION: <br />TYP TYPICAL <br />UON UNLESS OTHERWISE NOTED <br />1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR <br />ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS ON <br />THIS PAGE FOR ADDITIONAL INFORMATION. <br />2. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE <br />WITH NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR <br />BRANCH CIRCUITS. <br />3. FLUSH MOUNT ALL LIGHTING CONTROL DEVICES AT +42" FROM FLOOR (CENTERLINE <br />DIMENSION), EXCEPT WHERE OTHERWISE NOTED. <br />4. FLUSH MOUNT ALL DUPLEX RECEPTACLES OUTLETS AT +18" FROM FLOOR (CENTERLINE <br />DIMENSION), EXCEPT WHERE OTHERWISE NOTED. <br />5. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING MOUNTED DEVICES AND <br />EQUIPMENT WITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES <br />IN CEILING TILE PATTERN. OCCUPANCY/VACANCY SENSORS SHALL BE LOCATED NO CLOSER <br />THAN 3 FEET TO AN AIR SUPPLY DIFFUSER OR RETURN GRILLE. <br />6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL <br />OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE <br />EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR <br />SEALED INTO OPENINGS. <br />7. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE <br />WALLS, FLOORS, AND CEILINGS. THE CONTRACTOR WHOSE W ORK CAUSES DAMAGE IS <br />RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND <br />FINISH. <br />8. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL AND OTHER <br />ELECTRICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES, OTHER <br />THAN SPRINKLERS. <br />9. ELECTRICAL IDENTIFICATION. REFER TO SPECIFICATION SECTION 26 05 53 FOR COLOR/LABEL <br />REQUIREMENTS FOR CONDUIT, BOX, CABLE/WIRE, AND EQUIPMENT. <br />ELECTRICAL INSTALLATION NOTES: <br />ELECTRICAL GENERAL NOTES: <br />DEVICE # = MOUNTING (IF APPLICABLE) <br />1 = CIRCUIT NUMBER <br />*IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS <br />INFORMATION. EX: A / 1 <br />F1 = FIXTURE TAG <br />1 = CIRCUIT NUMBER <br />a = SWITCH DESIGNATION <br />*IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS <br />INFORMATION. EX: F1 / 1 / a <br />LUMINAIRE <br />LUMINAIRE KEY: <br />DEVICE KEY: <br />1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD <br />SURVEYS, EXISTING BUILDING DOCUMENTS. CONTRACTOR SHALL REVIEW EXISTING <br />CONDITIONS AND REPORT CONFLICTS. <br />2. NOT ALL EXISTING EQUIPMENT, LUMINAIRES, AND CONDUIT ARE SHOWN. CONTRACTOR <br />SHALL REVIEW EXISTING CONDITIONS AND REPORT CONFLICTS. <br />3. ELECTRICAL CONTRACTOR SHALL REVIEW EXISTING CONDITIONS TO VERIFY ACCESSIBILITY <br />TO THE AREAS OF THEIR WORK INCLUDING WALLS, FLOOR, AND CEILINGS. ELECTRICAL <br />CONTRACTOR IS RESPONSIBLE TO PROVIDE CUTTING, REMOVAL, PATCHING, AND <br />REINSTALLATION OF AFFECTED AREAS ASSOCIATED WITH THEIR WORK BY COORDINATING <br />WITH THE GENERAL CONTRACTOR OR QUALIFIED CONTRACTOR. <br />4. WHERE EXISTING ELECTRICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH NEW <br />EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER <br />ARRANGE NEW EQUIPMENT, CONDUIT, OR DUCTWORK IN SUCH A FASHION THAT IT DOES <br />NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING ELECTRICAL SYSTEMS TO <br />ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK. <br />ELECTRICAL RENOVATION NOTES: <br />THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED <br />TO LIGHTING AND POWER <br />26 05 33 JUNCTION BOXJ <br />ELECTRICAL SYMBOL LIST <br />SYMBOL:TAG:SPEC <br />SECTION:DESCRIPTION: <br />26 27 26 DUPLEX RECEPTACLE, 125V <br />26 05 33 TECHNOLOGY OUTLET ROUGH-IN (DUAL) <br />PANEL '###'PANELBOARD -SURFACE MOUNT <br />PANEL '###'PANELBOARD -RECESS MOUNT <br />26 05 33 ELECTRICAL CONNECTIONE <br />E <br />LUMINARE SYMBOL LIST <br />SYMBOL:TAG:SPEC <br />SECTION:DESCRIPTION: <br />REFER TO LUMINAIRE <br />SCHEDULE <br />TROFFER <br />SW -1P <br />SW -3W <br />SW -D <br />SW-O <br />SW -3R <br />26 09 33 <br />OC 26 09 33 <br />SWITCH <br />SUBSCRIPTS: <br />BLANK = SINGLE POLE <br />3 = 3-WAY SWITCH <br />D =DIMMER -STAND ALONE <br />O =DUAL TECHNOLOGY OCCUPANCY SENSOR <br />WITH WALL SWITCH <br />3R= NEMA 3R WEATHERPROOF SWITCH <br />OCCUPANCY SENSOR -CEILING MOUNTED <br />SUBSCRIPTS: <br />BLANK = DUAL TECHNOLOGY <br />A =ULTRASONIC -TWO SIDED CORRIDOR <br />COVERAGE <br />HB = HIGH BAY <br />SW-OC-D <br />SW -OC-A <br />SW -OC-HB <br />## <br />## <br />LINEAR LUMINAIRES <br />DOWNLIGHT LUMINAIRE <br />SINGLE FACE EXIT SIGN <br />DOUBLE FACE EXIT SIGN <br />S FIRE ALARM SMOKE DETECTOR, CEILING <br />MOUNT -PHOTOELECTRIC <br />FIRE ALARM VISUAL ALARM DEVICE, WALL <br />MOUNT <br />S CEILING MOUNT SPEAKER <br />J <br />BRANCH CIRCUITS: LIGHTING, RECEPTACLES, <br />CONTROLS, ETC. <br />CONDUIT INSTALLATION SCHEDULE <br />THE FOLLOWING SCHEDULE SHALL BE ADHERED TO UNLESS THEY CONSTITUTE A VIOLATION OF <br />APPLICABLE CODES OR ARE NOTED OTHERWISE ON THE DRAWINGS. THE INSTALLATION OF RMC <br />CONDUIT WILL BE PERMITTED IN PLACE OF ALL CONDUIT SPECIFIED IN THIS SCHEDULE. REFER <br />TO CONDUIT AND BOXES SPECIFICATION 26 05 33 FOR ADDITIONAL INFORMATION. <br />INSTALLATION TYPE FMC <br />X <br />EMT <br />X <br />BRANCH CIRCUIT SCHEDULE <br />SYMBOL:DESCRIPTION: <br />CONDUIT HOMERUN TO PANELBOARD. LETTER AND NUMERALS <br />INDICATE ELECTRICAL PANEL AND CIRCUIT NUMBER. <br />PANEL -CIRCUIT <br />2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 1 <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2 <br />(2021 INTERNATIONAL BUILDING CODE (IBC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 3 <br />(2020 NATIONAL ELECTRICAL CODE (NEC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 4 <br />(2021 UNIFORM MECHANICAL CODE (UMC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 5 <br />(2021 UNIFORM MECHANICAL CODE (UPC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA ENERGY CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 6 <br />2022 CALIFORNIA FIRE CODE (CFC) <br />CALIFORNIA CODES OF REGULATIONS (CRR) TITLE 24, PART 9 <br />(2021 INTERNATIONAL FIRE CODE (IFC) W/ 2022 CALIFORNIA AMENDMENTS) <br />2022 CALIFORNIA EXISTING BUILDING CODE <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 10 <br />(2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN) <br />CALIFORNIA CODES OF REGULATIONS (CCR) TITLE 24, PART 11 <br />2022 CALIFORNIA REFERENCED STANDARDS CODE <br />CALIFORNIA DOE OF REGULATIONS (CCR) TITLE 24, PART 12 <br />APPLICABLE CODES AND STANDARDS: <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />20" MAX. <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />20"-25" MAX. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />46 <br />" <br /> <br />M <br />A <br />X <br />. <br />10" MAX.10"-24" MAX. <br />ADA STANDARDS -FRONT ACCESS <br />ADA STANDARDS FOR ACCESSIBLE DESIGN <br />INSTALL ABOVE COUNTER <br />DEVICE AT 44" ABOVE <br />FINISHED FLOOR. <br />INSTALL ABOVE COUNTER <br />DEVICE AT 40" ABOVE <br />FINISHED FLOOR. <br />INSTALL DEVICE AT 18" <br />ABOVE FINISHED FLOOR. <br />ADA STANDARDS -SIDE ACCESS <br />INSTALL DEVICE AT 44" <br />ABOVE FINISHED FLOOR. <br />INSTALL DEVICE AT 42" <br />ABOVE FINISHED FLOOR. <br />ELECTRICAL CONTRACTORE.C. <br />CONTRACTOR ABBREVIATION KEY <br />ABBR:DESCRIPTION: <br />VIEW KEY <br />LINE TYPE AND TAG KEY: <br />NEW WORK BY THIS CONTRACTOR (WIDE LINE) <br />EXISTING TO REMAIN <br />HALFTONING DOES NOT MODIFY SCOPE. <br />'TAG'-(E)TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING <br />'TAG'-(R)TAGS WITH DASH 'R' INDICATES THE REFERENCED OBJECT IS REMOVED <br />TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL <br />INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST <br />INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL <br />PLAN OR DETAIL NUMBER <br />PLAN OR DETAIL NAME <br />PLAN OR DETAIL SCALE <br />DETAIL REFERRED TO BY SECTION CUT <br />SHEET DETAIL IS LOCATED ON <br />NAME <br />1 VIEW NAME <br />1/8" = 1'-0" <br />1 <br />M101 <br />1 <br />4 <br />3 <br />2 <br />SIMSIM <br />INDICATES SIMILAR DETAIL REFERENCED <br />IN MULTIPLE LOCATIONS <br />LEVEL NAME <br />10'-0"HEIGHT ABOVE <br />PROJECT 0'-0" <br />1 KEYNOTE: INDICATES NOTE USED TO <br />DESCRIBE ADDITIONAL INFORMATION <br />ABOUT WORK REQUIRED, SPECIFIC <br />TO THE SHEET AND/OR DETAIL <br />NO R HT <br />INDICATES DIRECTION OF TRUE NORTH <br />T101 <br />NEW <br />EXISTING TO BE REMOVED (SHORT DASHED PATTERN) <br />EXISTING (NARROW LINE PATTERN) <br />LUMINAIRE SCHEDULE LEGEND <br />OPTICS: <br />MOUNTING (MTG): <br />DIMENSIONS: <br />LIGHT SOURCE: <br />WATTS: <br />POWER SUPPLY: <br />CL -CEILING <br />WL -WALL <br />SOURCE TYPE <br />CCT / CRI <br />MAXIMUM ANSI WATTS PER: (BLANK) = PER LUMINAIRE FT = LINEAR FOOT <br />BEAM ANGLE <br />D -55 DEGREE BEAM SPREAD ANGLE, SEMI-SPECULAR FINISH <br />O -OTHERS <br />N/A -NOT APPLICABLE <br />VERIFY AND COORDINATE ALL CEILING TYPES WITH LUMINAIRE MOUNTING AND TRIM <br />REQUIREMENTS. REFER TO ARCHITECTURAL AND INTERIOR DESIGN ELEVATIONS, <br />SECTIONS, AND DETAILS FOR LUMINAIRE MOUNTING LOCATIONS AND REQUIREMENTS. <br />L -LENGTH Ø -DIAMETERW -WIDTH H -HEIGHT D -DEPTH <br />INTERIOR CORRELATED COLOR TEMPERATURE 3500K, COLOR <br />RENDERING INDEX (CRI) AT OR ABOVE 80, UNLESS NOTED <br />OTHERWISE. <br />LUMENS INDICATED ARE MINIMUM INITIAL DELIVERED LUMENS AT SPECIFIED CCT AND CRI. <br />PS TYPE <br />CONTROL <br />METHOD <br />(BLANK) -INTEGRAL UNLESS NOTED OTHERWISE <br />EM -EMERGENCY BATTERY <br />0-10V -0 TO 10V DIMMING <br /> 10%, 1%, 0.1%, 0.01% AS INDICATED <br />SWC -SWITCHED CONTROL <br />O -OTHER (SEE DESCRIPTION) <br />LED -INTEGRAL LIGHT EMITTING DIODE <br />COORDINATE LUMINAIRE DRIVER DIMMING METHODS AND PROTOCOLS WITH THE LIGHTING <br />CONTROL SYSTEM AND CONTROL MANUFACTURER REQUIREMENTS TO ENSURE DIMMING <br />COMPATIBILITY. <br />DELIVERED LUMENS: <br />VAR. -DIMENSION VARIES, SEE ARCHITECTURAL PLANS. <br />SCOPE OF WORK NOTES: <br />1. REPLACE 2X4 FLUOROSCENT TROFFER LIGHT WITH 2X4 LED TROFFER. <br />2. PROVIDE MANUAL CONTROL AND OCCUPANCY SENSOR IN CORRIDORS/LOBBY AREAS ON <br />FIRST, SECOND, AND THIRD FLOORS. <br />3. REPLACE OF EXISTING LIGHTING AND CONTROLS IN RESTROOMS 1902, 1902, 1105, 1106, <br />2105, 2106, 3103, & 3104. <br />4. PROVIDE POWER TO FAUCET AND FLUSH VALVE SENSORS IN RESTROOMS 1902, 1902, 1105, <br />1106, 2105, 2106, 3103, & 3104. <br />5. PROVIDE POWER AND DATA TO RELOCATED KIOSKS. <br />TE OLIRFFOAC <br />LANRP <br />E 23191 <br />STA <br />ER <br />REGIST <br />ED <br />INA <br />N <br />REENIGE <br />FO OISSE <br />E AICLCERTL <br />Exp. 06/30/26 <br />MIRASOPHOCLISGEORGY <br />IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO <br />THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING <br />AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT <br />BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE <br />EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. <br />©2024 IMEG CONSULTANTS CORP. <br />REF. SCALE IN INCHES <br />0 1 2 3 <br />222 S. HARBOR BOULEVARD <br />SUITE 800 <br />ANAHEIM, CA 92805 <br />P: 714.490.5555 F: 714.490.5560 <br />The FUTURE. Built Smarter www.imegcorp.com <br />PROJECT #24007312.00 <br />0 5' <br />GRAPHIC SCALES: <br />Issue Date <br />1/16" = 1'-0" <br />50' <br />1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" <br />0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' <br />Chckd By <br />Drwn By <br />Scale <br />Building ID: <br />KP Proj. No. <br />Permit No. <br />Sheet <br />SheetsOf <br />Sheet Title <br />Project <br />Facility <br />This document is the property of the Owner and is <br />Project Architect Approval: <br />Architect/Engineer Of Record: <br />IF THIS SHEET IS NOT 30"x42" , IT IS <br />A REDUCED PRINT - SCALE ACCORDINGLY <br />National Facilities Services <br />Post Office Box 12916 <br />Oakland California 94604 <br />not to be used without owner's written permission. <br />Floor Lev:Section: <br />HGW Proj. No. <br />© <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />h <br />a <br />n <br />n <br />a <br /> <br />g <br />a <br />b <br />r <br />i <br />e <br />l <br /> <br />w <br />e <br />l <br />l <br />s <br />, <br /> <br />a <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />ed <br />. <br /> <br /> <br />A <br />n <br />y <br /> <br />u <br />s <br />e <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />i <br />s <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br />l <br />y <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />ed <br />. <br /> <br /> <br />P <br />l <br />o <br />t <br />t <br />e <br />d <br />CAP029271 <br />1955 Bacon Street. San Diego, CA 92107 <br />Office 619 523 8487 <br />www.hgwarchitecture.com <br />PROJECT #24007312.00 <br />Revisions <br />By Appr. <br />As indicated <br />2/ <br />1 <br />0 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />1 <br />1 <br />: <br />5 <br />7 <br />: <br />1 <br />8 <br /> <br />A <br />M <br />01/23/2026 <br />Checker <br />Author <br />E001 <br />ELECTRICAL COVERSHEET <br />3401 South Harbor Boulevard, <br />Santa Ana, CA 92704 <br />2441 <br />HARBOR-MAC ARTHUR <br />ELECTRICAL SHEET INDEX <br />E001 ELECTRICAL COVERSHEET <br />E002 ELECTRICAL SPECIFICATIONS <br />E003 ELECTRICAL SPECIFICATIONS <br />E004 ELECTRICAL SPECIFICATIONS <br />E005 ELECTRICAL SPECIFICATIONS <br />E101 LEVEL 01 - ELECTRICAL PLAN - OVERALL <br />E102 LEVEL 02 - ELECTRICAL PLAN - OVERALL <br />E103 LEVEL 03 - ELECTRICAL PLAN - OVERALL <br />E111 LEVEL 01 - ENLARGED LIGHTING DEMOLITION PLAN <br />E112 LEVEL 01 - ENLARGED LIGHTING REMODEL PLAN <br />E113 LEVEL 02 - ENLARGED LIGHTING PLAN - AREA A <br />E114 LEVEL 02 - ENLARGED LIGHTING PLAN - AREA B <br />E115 LEVEL 03 - ENLARGED LIGHTING PLAN <br />E121 LEVEL 01 - ENLARGED POWER DEMOLITION PLAN <br />E122 LEVEL 01 - ENLARGED POWER REMODEL PLAN <br />E300 ELECTRICAL ENLARGED PLANS <br />E400 PARTIAL SINGLE LINE DIAGRAM & ELECTRICAL DETAILS <br />E500 PANEL SCHEDULES & LOAD SUMMARIES <br />E600 TITLE 24 <br />GRAND TOTAL: 19 <br />LUMINAIRE SCHEDULE <br />TAG DESCRIPTION OPTICS MTG DIMENSIONS <br />LIGHT <br />SOURCE <br />DELIVERED <br />LUMENS WATTS <br />POWER <br />SUPPLY MANUFACTURER - SERIES NOTES <br />D1 SQUARE DOWNLIGHT D RE 4 1/2"L X 4 1/2"W X 7"H LED 1,500 lm 17 / FIX 277 GOTHAM LIGHTING <br />EVO4-SQ-35/15-4AR-LSS-MVOLT-GZ10 <br />F1 VOLUMETRIC TROOFER WITH CENTER <br />BASKET <br />A RE 48"L X 24"W X 2 3/8"H LED 3,000 lm 23 / FIX 277 LITHONIA LIGHTING <br />2BLT4-30L-ADP-GZ10-LP835 <br />L15 LINEAR LED SLOT LIGHT O RE 180"L X 2"W X 3 1/2"H LED 5,550 lm 49 / FIX 277 MARK ARCHITECTURAL LIGHTING <br />SL1L-LOP-18FT-FL-90CRI-35K-400LMF-MIN1- <br />MVOLT-ZT <br />L16 LINEAR LED SLOT LIGHT O RE 192"L X 2"W X 3 1/2"H LED 5,920 lm 53 / FIX 277 MARK ARCHITECTURAL LIGHTING <br />SL1L-LOP-18FT-FL-90CRI-35K-400LMF-MIN1- <br />MVOLT-ZT <br />L18 LINEAR LED SLOT LIGHT O RE 216"L X 2"W X 3 1/2"H LED 6,660 lm 59 / FIX 277 MARK ARCHITECTURAL LIGHTING <br />SL1L-LOP-18FT-FL-90CRI-35K-400LMF-MIN1- <br />MVOLT-ZT <br />L23 LINEAR LED SLOT LIGHT O RE 276"L X 2"W X 3 1/2"H LED 8,510 lm 75 / FIX 277 MARK ARCHITECTURAL LIGHTING <br />SL1L-LOP-18FT-FL-90CRI-35K-400LMF-MIN1- <br />MVOLT-ZT <br />NOTES: <br />1. {L##} DENOTES THE LIGHTING SEQUENCE OF OPERATIONS FOR THIS SPACE. <br />2. a = SWITCH DESIGNATION FOR LIGHTING CONTROL <br />3. VERIFY AND COORDINATE ALL TIME CLOCK SETTINGS WITH OWNER PRIOR TO FINAL PROGRAMMING. <br />LIGHTING SEQUENCE OF OPERATION <br />PLAN ID LIGHTING SWITCHED <br />{LC1} SEQUENCE: Lighting control provides occupancy control, timeclock and emergency lighting control in this <br />space. <br />ON: <br />Lights turn on via timeclock to 50% maximum output, 60 minutes prior to facility open. <br />Lights turn on via occupancy sensor to 100% maximum output. <br />ADJUST: <br />Lights are raised/lowered controlled via occupancy sensor, lowered to 50% after space has been vacant for 15 <br />minutes. <br />OFF: <br />Lights turn off via timeclock 60 minutes after facility close. <br />Manual override: <br />Building has existing bypass timer switch to override timeclock operation. Additionally, Lights can be turn on <br />and turn off via local wall control. <br />Emergency control: <br />The emergency lights are controlled the same as normal lights. When normal power fails the switched <br />emergency lights turn on; 100% full output. When the fire alarm system is in alarm the switched emergency <br />lights turn on. The UL924 device shall bypass local lighting controls. The fire alarm system shall override the <br />local lighting controls. The lights shall remain on for [15] minutes minimum after normal power is restored or <br />fire alarm is reset. <br />{LD1} SEQUENCE: Lighting control provides occupancy control, timeclock and dimming lighting control in this space. <br />ON: <br />Lights turn on using a wall control. <br />Lights turn on via timeclock to 50% maximum output, 60 minutes prior to facility open. <br />Lights turn on via occupancy sensor to 50% maximum output. <br />ADJUST: <br />Lights are raised/lowered controlled using a wall controller, to 10-100% of maximum output. <br />OFF: <br />Lights turn off using a wall controller. <br />Lights turn off via timeclock 60 minutes after facility close. <br />Lights automatically turn off after the space has been vacant for 15 minutes. <br />Manual override: <br />Building has existing bypass timer switch to override timeclock operation. <br />{LS1} Sequence: Lighting control provides vacancy control, manual switching control in this space. <br />ON: <br />Lights turn on using a wall control. <br />OFF: <br />Lights turn off using a wall controller. <br />Lights automatically turn off after the space has been vacant for 15 minutes <br />No. Revisions Date <br />9 ASI-01 02/18/2026 <br />2/17/2026 <br />AS <br />I <br /> <br />- <br />0 <br />1 <br />10 <br />0 <br />% <br /> <br />C <br />D <br /> <br />S <br />E <br />T <br />pl <br />a <br />n <br /> <br />c <br />h <br />e <br />c <br />k <br /> <br />r <br />e <br />s <br />u <br />b <br />m <br />i <br />t <br />t <br />a <br />l