FIRST FLOOR <br />SECOND FLOOR <br />THIRD FLOOR <br />DIST. BOARD 'DBA' -(E) <br />1200A, 480/277V, 3Ø, 4W <br />400A <br />3P <br />TO MAIN SWBD <br />'MSA' -(E) <br />2-1/2"C., 3#4/0 <br />XFMR '1LA' -(E) <br />150 KVA <br />480:120/208V <br />'1PA1' -(E) <br />400A <br />'1LA' - (E) <br />'1PA3' - (E)'1PA2' - (E)'1PA5' - (E) <br />400A <br />3P <br />XFMR '2LA' -(E) <br />150 KVA <br />480:120/208V <br />'2PA1' -(E) <br />400A <br />'2LA' - (E) <br />'2PA3' - (E)'2PA2' - (E)'2PA5' - (E) <br />DIST. BOARD 'DBB' -(E) <br />1200A, 480/277V, 3Ø, 4W, 42 KAIC <br />400A <br />3P <br />TO MAIN SWBD <br />'MSA' -(E) <br />XFMR '1LB' -(E) <br />112.5 KVA <br />480:120/208V <br />'1PB1' -(E) <br />400A <br />'1LB' - (E) <br />'1PB2' - (E) <br />225A <br />3P <br />XFMR '3PB' -(E) <br />150 KVA <br />480:120/208V <br />'3PB1' -(E) <br />400A <br />'3LB' - (E) <br />'3PB2' - (E) '3PB3' - (E) <br />400A <br />3P <br />XFMR '2LA' -(E) <br />150 KVA <br />480:120/208V <br />'2PB1' -(E) <br />400A <br />'2LB' - (E) <br />'2PB2' - (E) '2PB3' - (E) <br />4"C., 4#500 <br />2"C., 4#2 <br />4"C., 4#500 <br />2"C., 4#2 <br />2-1/2"C., 3#4/0 <br />4"C., 4#500 <br />4"C., 4#500 <br />2"C., 3#2/0 <br />4"C., 4#500 <br />2"C., 4#1 <br />4"C., 4#500 <br />4"C., 4#500 <br />2"C., 4#1 <br />2-1/2"C., 3#4/0 <br />4"C., 4#500 <br />3"C., 4#4/0 <br />2"C., 4#1 <br />2-1/2"C., 3#4/0 <br />4"C., 4#500 <br />AREA OF WORK <br />AREA OF WORK <br />AREA OF WORK <br />AREA OF WORK <br />AREA OF WORK <br />AREA OF WORK <br />AREA OF WORK <br />AREA OF WORK <br />AREA OF WORK <br />A <br />B <br />C <br />A <br />B <br />B T-BAR <br />CEILING MEMBERS <br />MINIMUM 12 GAUGE SPLAY WIRE AT 45 DIAGONAL FROM OPPOSITE FIXTURE CORNERS (TWO <br />PER FIXTURE) TO STRUCTURE. ATTACH DIRECTLY TO FIXTURE <br />WITH 3 TIGHT TURNS MINIMUM, IN 1 1/2" MAXIMUM. SET WIRE SLIGHTLY SLACK TO ALLOW FULL <br />SEATING INTO T-BAR. <br />B POSITIVELY ATTACH FIXTURE TO T-BAR WITH LOCKING T-BAR CLIP RATED FOR 56 POUNDS OR <br />METAL SCREW THROUGH T-BAR INTO FIXTURE AT OPPOSITE CORNERS. ATTACH WIRE TO <br />FIXTURE. 3 TIGHT TURNS MINIMUM, IN 1-1/2" MAXIMUM. <br />FOR FIXTURES WEIGHING 56 POUNDS OR MORE <br />C 12 GAUGE SUPPORT WIRES WITH THREE TIGHT TURNS, IN 1 1/2" MAXIMUM AT EACH END. <br />ATTACH TO STRUCTURE ABOVE PER CEILING SUSPENSION DETAILS (4 PER FIXTURE) <br />RECESSED <br />LIGHTING FIXTURE <br />PER DRAWING AND <br />SCHEDULE. <br />FOUR (4) #12 GA. WIRE <br />ATTACHED TO FIXTURE <br />AND STRUCTURE, ONE <br />PER OPPOSITE <br />CORNER, <br />MAIN RUNNER <br />NOTES: <br />FOR FIXTURES WIGHTING 56 POUNDS OR LESS <br />NOTES: <br />1. PROVIDE SUPPORTS @ 10'-0"oc MAX SPACING, AND 2'-0" MAX FROM ENDS OF CONDUIT RUN <br />AND LOCATIONS WHERE CONDUIT CHANGES DIRECTION (EACH SIDE OF BEND). <br />2. 1-1/4" EMT CONDUIT WEIGHS 2.3 LBS PER FT OF RUN (INCLUDING WEIGHT OF CONDUCTORS <br />INSIDE THE CONDUIT). THE WEIGHT IS 5 LBS PER FT OR LESS (2019 CBC, 1617A.I.18 ASCE 7, <br />SECTION 13.1.4, EXEMPTION 3b), THEREFORE IT IS EXEMPT FROM SEISMIC DESIGN <br />REQUIREMENTS (BRACING NOT REQUIRED). <br />WITH HANGERS AT 10'-O" OC MAX, THE WEIGHT PER HANGER (SUPPORTING 1-1/4" EMT <br />CONDUIT) IS 23 LBS, WHICH IS LESS THAN THE HANGER CAPACITY (70 LBS), AND IS LESS <br />THAN 50 LBS PER HANGER (1617A.1.24 ASCE 7, SECTION 13.6.5, EXCEPTION 1b). <br />CADDY K16 OR K20 <br />INSTALL THE 0.145"Ø (0.300-INCH <br />HEAD DRIVE PIN) WITH 1-1/2" EMBED <br />INTO LOW FLUTE OF (E) 2-1/2" THK NWC <br />(F'c=4,000 PSI) OVER 2" STEEL DECK <br />PER ICC ESR-2024. <br />STIFFY <br />102-02-01-3-02-XX" <br />(1-1/2" PIN, 1/4" THREADED ROD) <br />SINGLE CONDUIT <br />LWC/NWC OVER 20GA. MIN., <br />METAL DECK. <br />J-BOX FOR 120-24V VOLTAGE TRANSFORMER <br />MOUNT J-BOX ABOVE ACCESSIBLE CEILING SPACE <br />3/4" C.O. CONCEALED IN WALL FOR LOW VOLTAGE <br />FLUSH VALVE SENSOR WIRING CONNECTION <br />CONDUIT TO PANEL <br />3/4" C.O. CONCEALED IN WALL FOR LOW VOLTAGE <br />FAUCET SENSOR WIRING CONNECTION <br />TYPE AC CABLE WHIP <br />3/4"C, 3#12 <br />TO (E) 277V POWER <br />TE OLIRFFOAC <br />LANRP <br />E 23191 <br />STA <br />ER <br />REGIST <br />ED <br />INA <br />N <br />REENIGE <br />FO OISSE <br />E AICLCERTL <br />Exp. 06/30/26 <br />MIRASOPHOCLISGEORGY <br />IMEG RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO <br />THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING <br />AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG AND SHALL NOT <br />BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE <br />EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG. <br />©2024 IMEG CONSULTANTS CORP. <br />REF. SCALE IN INCHES <br />0 1 2 3 <br />222 S. HARBOR BOULEVARD <br />SUITE 800 <br />ANAHEIM, CA 92805 <br />P: 714.490.5555 F: 714.490.5560 <br />The FUTURE. Built Smarter www.imegcorp.com <br />PROJECT #24007312.00 <br />0 5' <br />GRAPHIC SCALES: <br />Issue Date <br />1/16" = 1'-0" <br />50' <br />1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" <br />0 5'25' 0 1'12' 0 1'6' 0 4' 0 3'1'0 2' 0 1' <br />Chckd By <br />Drwn By <br />Scale <br />Building ID: <br />KP Proj. No. <br />Permit No. <br />Sheet <br />SheetsOf <br />Sheet Title <br />Project <br />Facility <br />This document is the property of the Owner and is <br />Project Architect Approval: <br />Architect/Engineer Of Record: <br />IF THIS SHEET IS NOT 30"x42" , IT IS <br />A REDUCED PRINT - SCALE ACCORDINGLY <br />National Facilities Services <br />Post Office Box 12916 <br />Oakland California 94604 <br />not to be used without owner's written permission. <br />Floor Lev: Section: <br />HGW Proj. No. <br />© <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />h <br />a <br />n <br />n <br />a <br /> <br />g <br />a <br />b <br />r <br />i <br />e <br />l <br /> <br />w <br />e <br />l <br />l <br />s <br />, <br /> <br />a <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />ed <br />. <br /> <br /> <br />A <br />n <br />y <br /> <br />u <br />s <br />e <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />i <br />s <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br />l <br />y <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />ed <br />. <br /> <br /> <br />P <br />l <br />o <br />t <br />t <br />e <br />d <br />CAP029271 <br />1955 Bacon Street. San Diego, CA 92107 <br />Office 619 523 8487 <br />www.hgwarchitecture.com <br />PROJECT #24007312.00 <br />Revisions <br />By Appr. <br />As indicated <br />11 <br />/ <br />2 <br />5 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />6 <br />: <br />0 <br />0 <br />: <br />3 <br />1 <br /> <br />P <br />M <br />08/15/2025 <br />Checker <br />Author <br />E400 <br />PARTIAL SINGLE LINE DIAGRAM & <br />ELECTRICAL DETAILS <br />3401 South Harbor Boulevard, <br />Santa Ana, CA 92704 <br />10 <br />0 <br />% <br /> <br />C <br />D <br /> <br />S <br />E <br />T <br />2441 <br />HARBOR-MAC ARTHUR <br />NTS01PARTIAL SINGLE LINE DIAGRAMS <br />NTS02RECESSED LAY-IN CEILING FIXTURE MOUNTING DETAIL <br />NTS033/4 AND 1 INCH EMT - CONDUIT SUPPORT DETAIL <br />NTS04RESTROOM TYP TRANSFORMER LOCATION <br />No. Revisions Date <br />pl <br />a <br />n <br /> <br />c <br />h <br />e <br />c <br />k <br /> <br />r <br />e <br />s <br />u <br />b <br />m <br />i <br />t <br />t <br />a <br />l <br />Plan Check Resubmittal 02/25/2026 <br />02/25/2026