20174439 - Permit
PBA
>
Building
>
Permits
>
T
>
Toddy St
>
1002 N Toddy St
>
20174439 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2021 8:56:22 AM
Creation date
10/19/2021 8:56:20 AM
Metadata
Fields
Template:
Permit
Permit Number
20174439
Full Address
1002 N Toddy St
Permit ID
280099
Master ID Number
2021-169278
Project Name
Miscellaneous Counter1 Permit
Street Number
001002
Street Direction
N
Street Name
Toddy
Street Suffix
St
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
10/6/2021
Issued Date
10/6/2021
Finalized Date
10/12/2021
Flood Zone
A-0602320143J
Description of Work
Install roof mounted solar panels, fees paid on 101108179.
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NOTES FOR STRSORNO STruNC SYSTEM ELECTRICRI- DIECRAM <br />Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />AddfeSS: i(D2 roddy srr..( s.rrr Arrl. cA e2703 <br />SYstem AC Size: s.tokwh <br />Site Name:Trm. Clndy Ct* <br />Site <br />Conbactor Namo, <br />Address and Phone: <br />FREEDOM FOREVER LLC <br />434/.5 BUSINESS PARK OR. <br />TEMECULA. CA 92595 <br />(888) ss7-6431 <br />Drawn By: <br />SIZE FSCM NO DWG NO REV <br />Checked By:SCALE NTS Date:SHEET <br />MODULE MAKE Longi Solar <br />MODULE MODEL LR4-6OHPB-350M <br />MAX POWER-POINT CURRENT (l*rr)10.18 A <br />MAX POWER-PO|NT VOLTAGE (VMP)34.4 v <br />oPEN-CtRCU rr VOLTAGE (Vo")40.4 v <br />sHoRT-CtRCUrr CURRENT (lsc)11.16 A <br />MAX SERTES FUSE (OCPD)20A <br />MAXTMUM POWER (PMA)()350 w <br />MAX VOLTAGE (TYP 600VDc) <br />VOC TEMP COEFF (mV/oCE or %loCO) <br />1000 v <br />45+2C <br />IF COEFF SUPPLIED, CIRCLE UNITS <br />SIGNS_SEE GUIDE SECTION 7 <br />NOTES FOR ALL DRAWINGS: <br />PV MODULE RATINGS @ STC (Guide Section 5) <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODEO REFERENCES <br />sHowN AS (rvEc )eooq <br />INVERTER RATINGS (Guide Section 4) <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D):NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): <br />1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP z oC <br />2.1 HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2O/O DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE TO OC <br />2.)2005 ASHRAE FUNDEMENTALS 2o/oDESTGN TEMPERATURES DO NOT EXCEED <br />47OC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1OC). FOR LESS THAN 9 <br />CURRENT-CARRYING CONDUCTORS IN ROOF.MOUNTED SUNLIT CONDUIT AT <br />LEAST 0.5'ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47oC OR LESS (ALL OF UNITED STATES), <br />al 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WItH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER <br />FUSE. <br />b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 1S.AMP OR SMALLER <br />FUSE. <br />1) tF UTtLtry REQUTRES A V|SIBLE-BREAK SWTTCH, DOES THIS SWITCH MEET THE <br />REQUIREMENT? YES tr NO ! N/A tr <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE <br />REQUIREMENT? YES E NO tr N/A tr <br />3) SIZE PHOTOVOLTATC POWER SOURCE (DC) C9NqU_CTORS BASED ON MA)( <br />CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT <br />4) S|ZE TNVERTER OUTPUT C|RCUTT (AC) CONDUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING. (See Guide Section 9) <br />5) TOTAL OF INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL <br />SUPPLY BREAKERS COMPLY WITH 120o/o BUSBAR EXCEPTION lN 690.il(BX2Xa)?YESE NOtr <br />INVERTER MAKE SOLAR EDGE <br />INVERTER MODEL SE6OOOH-US <br />MAX DC VOLT RATING 480 v <br />MAX POWER @ 40oC 9300 w <br />NOMINAL AC VOLTAGE 240 v <br />MAX AC CURRENT 25A <br />MAX OCPD RATING 35A <br />PHOTOVOLTAIC POWER SOURCE <br />RATED MPP CURRENT <br />RATED MPP VOLTAGE <br />25A <br />240 v <br />MAX SYSTEM VOLTAGE 480 v <br />MAX CIRCUIT CURRENT 16.5 A <br />WARNING: ELECTRICAL SHOCK <br />HA-ARD-LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />SIGN FOR INVERTER OCPD AND <br />AC DTSCONNECT (lF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />AC OUTPUT CURRENT 25A <br />NOMINAL AC VOLTAGE 240 v <br />THIS PANEL FED BY MULTIPLE <br />souRcES (uILlTY AND SOLAR) <br />rn <br />r/):EI <br />F,.t) <br />t) <br />dol& <br />r/) <br />tt1 <br />EI <br />Uod <br />=:dr! <br />o <br />EIio <br />Ir.l <br />O.xrI