Laserfiche WebLink
NOTES FOR STRSORNO STruNC SYSTEM ELECTRICRI- DIECRAM <br />Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />AddfeSS: i(D2 roddy srr..( s.rrr Arrl. cA e2703 <br />SYstem AC Size: s.tokwh <br />Site Name:Trm. Clndy Ct* <br />Site <br />Conbactor Namo, <br />Address and Phone: <br />FREEDOM FOREVER LLC <br />434/.5 BUSINESS PARK OR. <br />TEMECULA. CA 92595 <br />(888) ss7-6431 <br />Drawn By: <br />SIZE FSCM NO DWG NO REV <br />Checked By:SCALE NTS Date:SHEET <br />MODULE MAKE Longi Solar <br />MODULE MODEL LR4-6OHPB-350M <br />MAX POWER-POINT CURRENT (l*rr)10.18 A <br />MAX POWER-PO|NT VOLTAGE (VMP)34.4 v <br />oPEN-CtRCU rr VOLTAGE (Vo")40.4 v <br />sHoRT-CtRCUrr CURRENT (lsc)11.16 A <br />MAX SERTES FUSE (OCPD)20A <br />MAXTMUM POWER (PMA)()350 w <br />MAX VOLTAGE (TYP 600VDc) <br />VOC TEMP COEFF (mV/oCE or %loCO) <br />1000 v <br />45+2C <br />IF COEFF SUPPLIED, CIRCLE UNITS <br />SIGNS_SEE GUIDE SECTION 7 <br />NOTES FOR ALL DRAWINGS: <br />PV MODULE RATINGS @ STC (Guide Section 5) <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODEO REFERENCES <br />sHowN AS (rvEc )eooq <br />INVERTER RATINGS (Guide Section 4) <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D):NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): <br />1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP z oC <br />2.1 HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2O/O DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE TO OC <br />2.)2005 ASHRAE FUNDEMENTALS 2o/oDESTGN TEMPERATURES DO NOT EXCEED <br />47OC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1OC). FOR LESS THAN 9 <br />CURRENT-CARRYING CONDUCTORS IN ROOF.MOUNTED SUNLIT CONDUIT AT <br />LEAST 0.5'ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47oC OR LESS (ALL OF UNITED STATES), <br />al 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WItH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER <br />FUSE. <br />b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 1S.AMP OR SMALLER <br />FUSE. <br />1) tF UTtLtry REQUTRES A V|SIBLE-BREAK SWTTCH, DOES THIS SWITCH MEET THE <br />REQUIREMENT? YES tr NO ! N/A tr <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE <br />REQUIREMENT? YES E NO tr N/A tr <br />3) SIZE PHOTOVOLTATC POWER SOURCE (DC) C9NqU_CTORS BASED ON MA)( <br />CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT <br />4) S|ZE TNVERTER OUTPUT C|RCUTT (AC) CONDUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING. (See Guide Section 9) <br />5) TOTAL OF INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL <br />SUPPLY BREAKERS COMPLY WITH 120o/o BUSBAR EXCEPTION lN 690.il(BX2Xa)?YESE NOtr <br />INVERTER MAKE SOLAR EDGE <br />INVERTER MODEL SE6OOOH-US <br />MAX DC VOLT RATING 480 v <br />MAX POWER @ 40oC 9300 w <br />NOMINAL AC VOLTAGE 240 v <br />MAX AC CURRENT 25A <br />MAX OCPD RATING 35A <br />PHOTOVOLTAIC POWER SOURCE <br />RATED MPP CURRENT <br />RATED MPP VOLTAGE <br />25A <br />240 v <br />MAX SYSTEM VOLTAGE 480 v <br />MAX CIRCUIT CURRENT 16.5 A <br />WARNING: ELECTRICAL SHOCK <br />HA-ARD-LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />SIGN FOR INVERTER OCPD AND <br />AC DTSCONNECT (lF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />AC OUTPUT CURRENT 25A <br />NOMINAL AC VOLTAGE 240 v <br />THIS PANEL FED BY MULTIPLE <br />souRcES (uILlTY AND SOLAR) <br />rn <br />r/):EI <br />F,.t) <br />t) <br />dol& <br />r/) <br />tt1 <br />EI <br />Uod <br />=:dr! <br />o <br />EIio <br />Ir.l <br />O.xrI