D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG <br />LEGEND AND ABBREVIATIONS <br />DISCLAIMER: PLEASE NOTE THAT THE ABBREVIATIONS, ANNOTATIONS, AND SYMBOLS LISTED ARE <br />INTENDED TO ILLUSTRATE THOSE THAT ARE COMMONLY USED; NOT ALL ARE NECESSARILY <br />UTILIZED WITHIN THIS SET OF DRAWINGS. <br />ATTIC VENT <br />FLUSH ATTIC VENT <br />PVC PIPE VENT <br />SATELLITE DISH <br />T-VENT <br />CHIMNEY <br />FIRE SETBACKS <br />METAL PIPE VENT <br />HARDSCAPE <br />PROPERTY LINEPL <br />MAIN PANEL & SUB <br />PANELS <br />INVERTER(S) WITH <br />INTEGRATED DC <br />DISCONNECT AND AFCI <br />GENERAL LOCATION OF <br />EQUIPMENT <br />METER SOCKET & <br />DISCONNECTS <br />PV LOAD CENTER <br />BESS <br />(IF APPLICABLE) <br />GENERAL NOTES <br />VICINITY MAP <br />AMPERE <br />ALTERNATING CURRENT <br />AC DISCONNECT <br />AMERICANS WITH DISABILITIES ACT <br />AVAILABLE FAULT CURRENT <br />AMERICAN SOCIETY FOR TESTING AND MATERIALS <br />BATTERY ENERGY STORAGE SYSTEM <br />BUILDING <br />CLEAR <br />CANOPY, NEW <br />CONCRETE <br />CONDITIONS OF USE <br />CANOPY, RETROFIT <br />DIRECT CURRENT <br />DIAMETER <br />DISTANCE <br />EQUAL <br />EQUIPMENT GROUNDING CONDUCTOR <br />EXISTING <br />EACH <br />ELECTRICAL METALLIC TUBING <br />GALVANIZED <br />GROUNDING ELECTRODE CONDUCTOR <br />GROUND <br />HOT DIPPED GALVANIZED <br />CURRENT <br />CURRENT AT MAX POWER <br />INVERTERS <br />SHORT CIRCUIT CURRENT <br />KILOVOLT AMPERE <br />KILOWATT <br />KILOWATT-HOUR <br />LOAD BEARING WALL <br />MAXIMUM <br />MINIMUM <br />NEW <br />NATIONAL ELECTRIC CODE <br />NOT IN CONTRACT <br />NOT TO SCALE <br />ON CENTER <br />OVERCURRENT PROTECTION <br />POWER CONTROL SYSTEM <br />PROPERTY LINES <br />PHOTOVOLTAIC <br />POLYVINYL CHLORIDE <br />ROOF, BALLAST <br />ROOF, FLUSH MOUNT <br />SCHEDULE <br />SQUARE INCHES <br />STAINLESS STEEL <br />SEE STRUCTURAL DRAWINGS <br />STANDARD TESTING CONDITIONS <br />TYPICAL <br />UNLESS OTHERWISE NOTED <br />UNINTERRUPTIBLE POWER SUPPLY <br />VERIFY IN FIELD <br />VOLT <br />VOLTAGE AT MAX POWER <br />VOLTAGE AT OPEN CIRCUIT <br />WATT <br />NEMA 3R, RAINTIGHT <br />A <br />AC <br />ACDS <br />ADA <br />AFC <br />ASTM <br />BESS <br />BLDG <br />CLR <br />CN <br />CONC <br />C.O.U <br />CR <br />DC <br />DIA <br />DIST <br />EQ <br />EGC <br />(E) <br />EA. <br />EMT <br />GALV <br />GEC <br />GND <br />HDG <br />I <br />Imp <br />INVS <br />Isc <br />kVA <br />kW <br />kWh <br />LBW <br />MAX <br />MIN <br />(N) <br />NEC <br />NIC <br />NTS <br />OC <br />OCP <br />PCS <br />PL <br />PV <br />PVC <br />RB <br />RF <br />SCH <br />SQ. IN. <br />SS <br />SSD <br />STC <br />TYP <br />UON <br />UPS <br />VIF <br />V <br />Vmp <br />Voc <br />W <br />3R <br />ABBREVIATIONS <br />DESIGN WIND SPEED: 96 MPH <br />EXPOSURE: B <br />SNOWLOAD: 0 PSF <br />WEATHER STATION: POLARIS DATA <br />DESIGN LOW TEMP: -2°C <br />2% DRY BULB: 38°C <br />SDS: 1.023 <br />MOUNTING PLANE HEIGHT(S): 20 FT <br />BUILDING STORIES: 2/1 <br />CONSTRUCTION TYPE: V-A <br />OCCUPANCY GROUP: R-2 <br />AUTOMATIC FIRE SPRINKLERS: No <br />PROJECT INFORMATION <br />RAIL <br />STANDOFFS & <br />FOOTINGS <br />SOLAR MODULES <br />AERIAL MAP <br />SITE NOTES: <br />·A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. <br />·THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. <br />·THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. <br />·PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. <br />·ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S <br />INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. <br />·NO CHANGE TO PARKING OR STRIPING <br />·PV MODULES ARE TYPE I FIRE RATED AND THE CANOPY STRUCTURE IS OPEN AIR AND NON-HABITABLE. <br />EQUIPMENT LOCATIONS: <br />·ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. <br />·WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND <br />NEC TABLES 310.15 (B)(1) AND 310.15 (B)(2) IF RACEWAYS ARE < 7/8" ABOVE THE ROOF. <br />·JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. <br />·ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. <br />·ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. <br />·ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. <br />STRUCTURAL NOTES: <br />·RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE <br />BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL <br />MANUFACTURER’S INSTRUCTIONS. <br />·JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL <br />REQUIREMENTS. <br />·ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED <br />CONTRACTOR. <br />·ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. <br />·WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. <br />DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: <br />·DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO <br />THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). <br />·DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH. <br />·DC DISCONNECT INTEGRATED INTO ROOFTOP DC COMBINER OR INSTALLED WITHIN 6 FT, ACCORDING TO NEC 690.15(B). <br />·ALL PV CIRCUITS LOCATED OUTSIDE THE ARRAY BOUNDARY OR MORE THAN 3 FT FROM THE POINT OF ENTRY INSIDE A BUILDING SHALL BE LIMITED TO NOT <br />MORE THAN 30 VOLTS WITHIN 30 SECONDS, CIRCUITS INSIDE THE ARRAY BOUNDARY OR NOT MORE THAN 3 FT FROM THE POINT OF PENETRATION SHALL BE <br />LIMITED TO NOT MORE THAN 80 VOLTS UPON RAPID SHUT-DOWN INITIATION PER 690.12. <br />·ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. <br />WIRING & CONDUIT NOTES: <br />·ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE <br />REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. <br />·CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. <br />·ALL CONDUIT MUST ACCOUNT FOR ENVIRONMENTAL CONDITIONS AND THERMAL EXPANSIONS ACCORDING TO NEC 300.7. <br />·PV WIRE BLACK WIRE MAY BE FIELD-MARKED BY MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, <br />TAGGING, OR OTHER APPROVED MEANS. <br />·MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. <br />·RACKING, MID CLIPS, END CLIPS, AND MODULES UL2703 LISTED <br />·ACCORDING TO NEC 200.7, SYSTEMS DC CONDUCTORS COLORED OR MARKED AS FOLLOWS: <br />···DC POSITIVE- RED, OR OTHER COLOR EXCLUDING WHITE, GRAY AND GREEN <br />···DC NEGATIVE- BLACK, OR ANY COLOR EXCLUDING WHITE, GRAY AND GREEN <br />·AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: <br />···PHASE A OR L1- BLACK <br />···PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE <br />···PHASE C OR L3- BLUE, YELLOW, ORANGE*, OR OTHER CONVENTION <br />···NEUTRAL- WHITE OR GRAY <br />*IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15]. <br />CODES AND STANDARDS <br />SHEET INDEXBILL OF MATERIALS <br />NEW PV AND ENERGY STORAGE SYSTEM: <br />ON ROOF <br />PV SYSTEM: 259.12 DCkW, 186.2 ACkW, 241.45 CEC ACkW <br />ENERGY STORAGE SYSTEM: 184.8 ACkW, 523.8 kWH <br />WILSHIRE MINNIE <br />1235 E WILSHIRE AVE, SANTA ANA, CA 92707, USA <br />APN #: 014-251-49/014-251-50 <br />BUILDING: IBC 2024 <br />LOCAL BUILDING: CBC 2025 <br />OCCUPANCY GROUP: R-2 <br />ELECTRICAL: NEC 2023 <br />LOCAL ELECTRICAL: CEC 2025 <br />FIRE: CFC 2025 <br />AHJ: CA-CITY OF SANTA ANA <br />UTILITY: SCE <br />C100 : COVERSHEET <br />E100 : ELECTRICAL SITE PLAN <br />E101 : ELECTRICAL SITE PLAN <br />E102 : ELECTRICAL SITE PLAN <br />E200 : ELECTRICAL PLAN VIEWS <br />E201 : ELECTRICAL PLAN VIEWS <br />E202 : ELECTRICAL PLAN VIEWS <br />E300 : ELECTRICAL STRINGING <br />E301 : ELECTRICAL STRINGING <br />E302 : ELECTRICAL STRINGING <br />E303 : ELECTRICAL STRINGING <br />E400 : ELECTRICAL DETAILS <br />E401 : ELECTRICAL DETAILS <br />E500 : ELECTRICAL NOTES <br />E600 : ONELINE DIAGRAM POI-1 <br />E601 : ONELINE DIAGRAM POI-2 <br />E602 : ONELINE DIAGRAM POI-3 <br />E603 : ONELINE DIAGRAM POI-4 <br />E604 : ONELINE DIAGRAM POI-5 <br />E605 : ONELINE DIAGRAM POI-6 <br />E606 : ONELINE DIAGRAM POI-7 <br />E800 : WARNING LABELS <br />E801 : WARNING LABELS <br />E810 : SITE PLACARDS <br />S100 : STRUCTURAL SITE PLAN <br />S200 : STRUCTURAL ARRAY DETAIL <br />S201 : STRUCTURAL ARRAY DETAIL <br />S202 : STRUCTURAL ARRAY DETAIL <br />S203 : STRUCTURAL ARRAY DETAIL <br />S300 : STRUCTURAL SIDE SECTIONS <br />S400 : STRUCTURAL ATTACHMENT DETAILS <br />S401 : STRUCTURAL ATTACHMENT DETAILS <br />S500 : EQUIPMENT PAD <br />R100 : REFERENCE SHEETS <br />R101 : REFERENCE SHEETS <br />R102 : REFERENCE SHEETS <br />R103 : REFERENCE SHEETS <br />R104 : REFERENCE SHEETS <br />R105 : UL9540A <br />R106 : UL9540A <br />R107 : UL9540A <br />MODULES: <br />(632) QCELLS NORTH AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 <br />OPTIMIZERS: <br />(632) SOLAREDGE U650 <br />INVERTERS: <br />(11) SOLAREDGE SE11400H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] <br />(8) SOLAREDGE SE7600H-US HOME HUB [240V] [SI1-SB] [CRD-PCS NEM] <br />MONITORING: <br />(19) CELL-B-R05-US-S-S2 <br />BESS: <br />(54) SOLAREDGE BAT-10K1P <br />(19) SOLAREDGE HOME NET CARD <br />(54) SEDG FLOOR MOUNT <br />RACKING: <br />FLUSH ROOF: ULTRAFOOT RAFTER - 1 LAG <br />FLAT ROOF: SNAPNRACK TILT KIT - OMNIBASE <br />SCOPE OF WORK <br />INSTALL 259.12 kW-DC OF PV AND 523.8 kWh OF ESS AT SEVEN (7) DIFFERENT INTERCONNECTION POINTS (POIs) AT WILSHIRE MINNIE APARTMENTS: <br />POI #PV LOCATION PV kW ESS Location ESS <br />QTY <br />ESS <br />kWh INTERCONNECTION LOCATION <br />1 <br />1201 E WILSHIRE AVE 19.68 <br />1209 3/4 E WILSHIRE AVE UNIT# ELE01 12 116.4 1209 E WILSHIRE AVE UNIT# MTR021209 E WILSHIRE AVE 17.22 <br />1213 E WILSHIRE AVE 17.22 <br />2 <br />1221 E WILSHIRE AVE 17.22 <br />1221 3/4 E WILSHIRE AVE UNIT# ELE01 9 87.3 1221 E WILSHIRE AVE UNIT# MTR02 <br />1225 E WILSHIRE AVE 30.34 <br />3 <br />1229 E WILSHIRE AVE 29.52 <br />1229 3/4 E WILSHIRE AVE UNIT# ELE01 9 87.3 1229 E WILSHIRE AVE UNIT# MTR02 <br />1235 E WILSHIRE AVE 17.22 <br />4 1233 E WILSHIRE AVE 28.70 ESS CONCRETE PAD 6 58.2 1233 E WILSHIRE AVE UNIT# MTR01 <br />5 1401 S MINNIE ST 35.67 1401 S MINNIE ST (WALL MOUNT)6 58.2 1401 S MINNIE ST UNIT# MTR01 <br />6 1403 S MINNIE ST 22.96 1403 S MINNIE ST (WALL MOUNT)6 58.2 1403 S MINNIE ST UNIT# MTR01 <br />7 1425 S MINNIE ST 23.37 1425 S MINNIE ST (WALL MOUNT)6 58.2 1425 S MINNIE ST UNIT# MTR01 <br />TOTALS 259.12 54 524 <br />D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG <br />COVER SHEET <br />CONTRACTOR: <br />ENGINEERING APPROVAL: <br />600 CALIFORNIA ST #1800, SAN <br />FRANCISCO, CA 94104 <br />CA CL #750184 <br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT <br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. <br />WILSHIRE MINNIE <br />1235 E WILSHIRE AVE, <br />SANTA ANA, CA 92707, USA <br />APN:014-251-49/014-251-50 <br />DEVELOPER: <br />C&C DEVELOPMENT <br />DESCRIPTION DATE REV <br />0ORIGINAL06/23/25 <br />BAHJ COMMENTS #2 12/10/25 <br />CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 <br />PROJECT DETAILS: <br />PV SYSTEM: <br />·259.12 kW DC <br />·186.2 kW AC <br />·241.45 CEC AC <br />ENERGY STORAGE: <br />·184.8 kW AC <br />·523.8 kWH <br />C100 <br />SHEET SIZE: <br />REVISION: <br />SHEET TITLE: <br />36" X 24" (ARCH D) <br />DESIGNER: <br />FINS_TM <br />C <br />PROJECT NUMBER: <br /> PROP-001235 <br />ASYSTEM DOWNSIZED 09/05/25 <br />AHJ COMMENTS #1 & <br />#ESTAMP <br />#SSTAMP <br />WILSHIRE MINNIE <br />1209 E WILSHIRE AVE UNIT# MTR02 <br />1209 3/4 E WILSHIRE AVE UNIT# ELE01 <br />1221 E WILSHIRE AVE UNIT# MTR02 <br />1221 3/4 E WILSHIRE AVE UNIT# ELE01 <br />1229 E WILSHIRE AVE UNIT# MTR02 <br />1229 3/4 E WILSHIRE AVE UNIT# ELE01 <br />1233 E WILSHIRE AVE UNIT# MTR01 <br />1401 S MINNIE ST UNIT# MTR01 <br />1403 S MINNIE ST UNIT# MTR01 <br />1425 S MINNIE ST UNIT# MTR01 <br />APN: 014-251-49 / 014-251-50 <br />DEVELOPER: C&C DEVELOPMENT