My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1201-1235 E Wilshire Ave & 1401-1403, 1425 S Minnie St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Susan St
>
3001 S Susan St
>
1201-1235 E Wilshire Ave & 1401-1403, 1425 S Minnie St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2026 5:00:30 AM
Creation date
6/5/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20186607
20186694
20186695
20186696
20186697
20186698
20186699
20186700
20186701
20186702
20186703
101124723
101124724
101124725
101124726
101124727
101124728
101124729
101124730
101124731
101124732
101124736
Full Address
3001 S Susan St
1201 E Wilshire Ave
1209 E Wilshire Ave
1213 E Wilshire Ave
1221 E Wilshire Ave
1225 E Wilshire Ave
1229 E Wilshire Ave
1233 E Wilshire Ave
1235 E Wilshire Ave
1401 S Minnie St
1403 S Minnie St
1425 S Minnie St
Street Number
1425
Street Direction
S
Street Name
Minnie
Street Suffix
St
Document Relationships
20186607 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Susan St\3001 S Susan St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
6' <br />- <br />3 <br />" <br /> <br />M <br />A <br />X <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />FR <br />O <br />M <br /> <br />G <br />R <br />A <br />D <br />E <br />B (N) NGO METER SOCKET ≤ 200A <br />NTS <br />10" <br />MIN. <br />MIN. CLEARANCE <br />TO OBSTRUCTIONS <br />OR SIDE WALLS <br />36" MIN. <br />(N) HOUSEKEEPING PAD <br />THE PAD SHALL BE FLUSH WITH <br />THE BOTTOM OF THE SERVICE EQUIPMENT <br />AND EXTEND A MINIMUM OF THREE FEET. <br />10" <br />MIN. <br />18" MIN. <br />MIN. CLEARANCE TO <br />EDGE OF WINDOW <br />OR DOOR <br />- NGO METER WORKING SPACE <br />TO BE MAINTAINED. <br />- EQUIPMENT ABOVE OR BELOW <br />NGOM WILL NOT EXCEED <br />DEPTH OF NGOM. <br />- NGOM TO BE MOUNTED ON <br />STRUT IF NEEDED TO <br />ACCOUNT FOR ANY DEPTH <br />DIFFERENCES. <br />- CENTER OF METER CAN NOT <br />TO EXCEED 6'-3" MAX, 4'-0" MIN. <br />-EQUIPMENT AND CONDUIT <br />SHOWN IS DIAGRAMMATIC <br />ONLY. SEE LINE DRAWINGS <br />FOR CONDUIT SIZING. <br />NOTES <br />MIN. CLEARANCE TO <br />PLUMBING FIXTURES <br />EXTENDING 6" OUT <br />FROM WALL SURFACE <br />6' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />CL <br />E <br />A <br />R <br />A <br />N <br />C <br />E <br />FR <br />O <br />M <br /> <br />G <br />R <br />A <br />D <br />E <br />(E) GRADE <br />A AC DISCONNECT <br />(E) GRADE <br />75 <br />" <br /> <br />M <br />A <br />X <br />HE <br />I <br />G <br />H <br />T <br /> <br />F <br />R <br />O <br />M <br /> <br />G <br />R <br />A <br />D <br />E <br />NOTES <br />- INSTALLED AT VERTICAL <br />HIEGHT OF BEWTEEN 48" MIN <br />AND 75" MAX, MEASURED <br />FROM GROUND TO TOP OF <br />ENCLOSURE <br />-EQUIPMENT AND CONDUIT <br />SHOWN IS DIAGRAMMATIC <br />ONLY. SEE LINE DRAWINGS <br />FOR CONDUIT SIZING. <br />DISCONNECT <br />(N) PV UTILITY <br />DISCONNECT <br />C INVERTER CLEARANCE - SOLAREDGE HOME HUB <br />MIN. CLEARANCE <br />BACK TO BACK <br />INVERTERS 8" MIN. <br />CLEAR <br />16" MIN. <br />CLEAR <br />8" MIN. <br />CLEAR <br />MIN. CLEARANCE <br />VERTICALLY <br />STACKED INVERTERS <br />8" MIN. <br />CLEAR <br />MIN. CLEARANCE <br />SIDE-BY-SIDE INVERTERS <br />- LISTED MIN. CLEARANCES FOR <br />INVERTER TO OTHER <br />OBJECTS, UNLESS NOTED <br />- MIN. CLEARANCES REQUIRED <br />FOR HEAT DISSIPATION <br />- CONDUIT MAY BE REQUIRE <br />ADDITIONAL CLEARANCE <br />-EQUIPMENT AND CONDUIT <br />SHOWN IS DIAGRAMMATIC <br />ONLY. SEE LINE DRAWINGS <br />FOR CONDUIT SIZING. <br />NOTES <br />8" MIN. <br />CLEAR <br />4" MIN. <br />CLEAR <br />4" MIN. <br />CLEAR <br />4" MIN. <br />CLEAR <br />46.4" <br />9.84" <br />BATTERY WEIGHT: 262LBS <br />31.1" 8" MIN. CLEAR <br />MIN. CLEARANCE <br />BATTERY SHOWN ON <br />OPTIONAL FLOOR STAND <br />KIT <br />SOLAREDGE ENERGY BANK <br />BAT-10K1P <br />D BESS CLEARANCE - SOLAREDGE ENERGY BANK <br />·LISTED MIN. CLEARANCES FOR ENERGY BANK TO OTHER <br />OBJECTS AS REQUIRED BY MANUFACTURER. NEC 110.3(B) <br />·BATTERY CAN BE WALL MOUNTED OR USE MANUFACTURES <br />FLOOR STAND KIT. <br />·8" MIN. CLEARANCES REQUIRED FOR HEAT DISSIPATION <br />·CONDUIT MAY REQUIRE ADDITIONAL CLEARANCE. <br />·EQUIPMENT AND CONDUIT SHOWN IS DIAGRAMMATIC ONLY. <br />·WORKING CLEARANCES SHALL BE IN ACCORDANCE WITH NEC <br />110.26 FOR ANY COMPONENTS THAT ARE LIKELY TO REQUIRE <br />EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE <br />WHILE ENERGIZED. <br />·BATTERIES SHALL NOT BE INSTALLED IN DIRECT SUNLIGHT <br />WITH OUT SHADE COVER <br />NOTES <br />8" MIN. <br />CLEAR <br />8" MIN. <br />CLEAR <br />8" MIN. <br />CLEAR <br />SOLAREDGE ENERGY BANK <br />WITH 4 BATTERIES ON FLOOR STAND KITS <br />53.15" <br />MIN. <br />6.3" <br />13.78" <br />1ST BATTERY FLOOR <br />STAND TO BE ANCHORED <br />TO WALL/RACK <br />SIDE BRACKETS <br />FOR <br />ATTACHING <br />BATTERIES <br />MIN. CLEAR IF <br />WALL MOUNTING <br />DC <br />CONNECTION <br />LOCATION <br />(N) AC DISCONNECT <br />GENERAL NOTES <br />·FIELD VERIFY ALL MEASUREMENTS <br />·ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ANY OTHER REGULATING AUTHORITIES <br />WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK. <br />·DRAWINGS HAVE BEEN DETAILED IN COMPLIANCE WITH UL LISTING REQUIREMENTS, OSFM SOLAR <br />PHOTOVOLTAIC INSTALLATION REQUIREMENTS, AND BUILDING CODES FOR THE MATERIALS SPECIFIED. PRIOR <br />TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND NOTIFY THE <br />DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FROM SUNRUN OF ANY DISCREPANCIES. ANY WORK <br />PERFORMED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT THE <br />SUBCONTRACTORS SOLE EXPENSE. <br />·SUBCONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO SUNRUN FOR APPROVAL BEFORE <br />MAKING ANY CHANGES OR DEVIATION FROM PLANS BEFORE WRITTEN APPROVAL FROM SUNRUN PLACES <br />LIABILITY ON THE SUBCONTRACTOR. <br />·ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, CONTRACTOR SHALL <br />USE STANDARD CONSTRUCTION PRACTICES. <br />·ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT TO MATCH EXISTING <br />FINISHES. ANY METAL SHAVINGS FROM SITE WORK SHALL BE CLEANED FROM ALL SURFACES WHERE OXIDIZED <br />OR CONDUCTIVE METAL SHAVINGS MY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE. <br />·APPROVALS FROM BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE <br />DRAWINGS. <br />·ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO <br />PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT IN ACCORDANCE WITH THE <br />CALIFORNIA ELECTRICAL CODE AND THE MANUFACTURER'S INSTRUCTIONS. <br />·ELECTROCHEMICAL ESS SHALL BE SEGREGATED INTO GROUPS NOT EXCEEDING 80 KWH PER CFC 127.5.1 AND <br />UL9540A REPORT. EACH GROUP SHALL BE SEPARATED A MINIMUM OF 3 FEET (914 MM) FROM OTHER GROUPS <br />AND FROM WALLS IN THE STORAGE ROOM OR AREA. THE STORAGE ARRANGEMENTS SHALL COMPLY WITH <br />CHAPTER 10. <br />·AREAS WITHIN 10 FEET (3048 MM) ON EACH SIDE OF OUTDOOR ESS SHALL BE CLEARED OF COMBUSTIBLE <br />VEGETATION AND OTHER COMBUSTIBLE GROWTH. SINGLE SPECIMENS OF TREES, SHRUBBERY OR CULTIVATED <br />GROUND COVER SUCH AS GREEN GRASS, IVY, SUCCULENTS OR SIMILAR PLANTS USED AS GROUND COVER <br />SHALL BE PERMITTED TO BE EXEMPT PROVIDED THAT THEY DO NOT FORM A MEANS OF READILY TRANSMITTING <br />FIRE. <br />·OUTDOOR INSTALLATIONS SHALL BE IN ACCORDANCE WITH SECTIONS 1207.8.1 THROUGH 1207.8.3. EXTERIOR <br />WALL INSTALLATIONS FOR INDIVIDUAL ESS UNITS ARE 9.7 KWH AND DO NOT EXCEED 20 KWH. ESS OUTDOOR <br />INSTALLATION SHALL BE IN ACCORDANCE WITH SECTION 1207.8.4. <br />··THE MAXIMUM ENERGY CAPACITY OF INDIVIDUAL ESS UNITS SHALL NOT EXCEED 20 KWH. <br />··THE ESS SHALL COMPLY WITH APPLICABLE REQUIREMENTS IN SECTION 1207. <br />··THE ESS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THEIR <br />LISTING. <br />··INDIVIDUAL ESS UNITS SHALL BE SEPARATED FROM EACH OTHER BY AT LEAST 8" PER MANUFACTURER <br />INSTRUCTIONS AND UL9540A REPORT <br />·THE ESS SHALL BE SEPARATED FROM DOORS, WINDOWS, OPERABLE OPENINGS INTO BUILDINGS OR HVAC <br />INLETS BY AT LEAST 3 FEET PER UL9540A REPORT <br />·ESS LOCATED OUTDOORS SHALL BE SEPARATED BY A MINIMUM OF 10 FEET (3048 MM) FROM EXPOSURES <br />LISTED ON CFC 1207.8.3. <br />1'1' <br />4" <br />1'1'1' <br />D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG <br />ELECTRICAL PLAN VIEWS <br />CONTRACTOR: <br />ENGINEERING APPROVAL: <br />600 CALIFORNIA ST #1800, SAN <br />FRANCISCO, CA 94104 <br />CA CL #750184 <br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT <br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. <br />WILSHIRE MINNIE <br />1235 E WILSHIRE AVE, <br />SANTA ANA, CA 92707, USA <br />APN:014-251-49/014-251-50 <br />DEVELOPER: <br />C&C DEVELOPMENT <br />DESCRIPTION DATE REV <br />0ORIGINAL06/23/25 <br />BAHJ COMMENTS #2 12/10/25 <br />CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 <br />PROJECT DETAILS: <br />PV SYSTEM: <br />·259.12 kW DC <br />·186.2 kW AC <br />·241.45 CEC AC <br />ENERGY STORAGE: <br />·184.8 kW AC <br />·523.8 kWH <br />E202 <br />SHEET SIZE: <br />REVISION: <br />SHEET TITLE: <br />36" X 24" (ARCH D) <br />DESIGNER: <br />FINS_TM <br />C <br />PROJECT NUMBER: <br /> PROP-001235 <br />ASYSTEM DOWNSIZED 09/05/25 <br />AHJ COMMENTS #1 & <br />#ESTAMP <br />(N) PV POINT OF INTERCONNECTION (POI-7) <br />(N) PV PRODUCTION METER SOCKET 1425 S MINNIE <br />ST UNIT# MTR01 PV PRODUCTION METER <br />REFERENCE METER NUMBER: 222013-124043 <br />(N) UTILITY AC DISCONNECT (ACDS-7.1) <br />(N) MAINTENANCE AC DISCONNECT (ACDS-7.2) <br />(N) AC LOAD CENTER (LC-7.1) <br />(N) PV INVERTER AND ESS AC DISCONNECT (INV-7.1) <br />(N) PV INVERTER AND ESS AC DISCONNECT (INV-7.2) <br />E EQUIPMENT PLAN - POI-7 1425 MINNIE ST <br />SCALE: 3/16" = 1'-0" <br />(N) 58.2 kWh ESS GROUP OF <br />(6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED <br />(EACH BATTERY 9.7KWh) <br />1425 MINNIE ST <br />1207.8.3 <br />1207.4.2 & 110.26(A)(1) <br />WORKING CLEARANCE <br />1429 MINNIE ST <br />F ESS ELEVATION - POI-7 1425 MINNIE ST <br />SCALE: 3/8" = 1'-0" <br />1425 MINNIE ST <br />(N) AC LOAD CENTER (LC-7.1) <br />(N) PV INVERTER AND ESS AC DISCONNECT (INV-7.1) <br />(N) PV INVERTER AND ESS AC DISCONNECT (INV-7.2) <br />(N) 58.2 kWh ESS GROUP OF <br />(6) SOLAREDGE BAT-10K1P BATTERIES WALL MOUNTED <br />3'-6"11'-10" <br />35'-11" <br />DISTANCE <br />BETWEEN <br />BUILDIGNS <br />WILSHIRE MINNIE <br />1425 S MINNIE ST UNIT# MTR01 <br />APN: 014-251-50 <br />DEVELOPER: <br /> C&C DEVELOPMENT <br />11 <br />' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />1 <br />"
The URL can be used to link to this page
Your browser does not support the video tag.