##KEYED NOTES#EQUIPMENT NOTES# <br /># <br />COMMUNICATION <br />CAT5E 600V RATED SHIELDED CABLE. <br />INSTALLER SHALL FOLLOW <br />MANUFACTURES RECOMMENDATION FOR <br />WIRE SIZING BASED ON LENGTH. <br />CIRCUIT IDENTIFIER <br />EQUIPMENT INDEX <br />EQUIPMENT TYPE <br />SYSTEM IDENTIFIER X INDICATES LETTERS <br /># INDICATES NUMBERS <br />XX-#.# <br />SYSTEM SUMMARY <br />15.20 ACKW | 22.96 DCKW | 21.39 CECKW <br /> 15.20 BESS ACKW | 58.20 BESS KWH <br />TOTAL FAULT CURRENTS <br />UTILITY: 42,000A | GENERATORS: 148A <br />DESCRIPTION OF OPERATION (DOO) <br />1.INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 PCS CRD AND WILL HAVE <br />EXPORT-ONLY MODES ENABLED. THEY WILL UTILIZE EXCESS PV POWER TO CHARGE <br />THE BATTERIES AND THE BATTERIES WILL DISCHARGE DURING SET HOURS. <br />2.THE PRODUCER'S STORAGE DEVICE(S) WILL NOT CONSUME POWER FROM THE <br />DISTRIBUTION PROVIDER'S DISTRIBUTION SYSTEM AT ANY TIME. <br />3.GRID EXPORT IS ALLOWED THROUGH NEMV METER. <br />4.DURING UTILITY GRID OUTAGE THE PV GENERATION AND BESS WILL DISCONNECT <br />FROM THE GRID AND REMAIN DISCONNECTED UNTIL GRID VOLTAGE IS RESTORED TO <br />THE ACCEPTABLE MEASURE. <br />+- <br />18 <br />14 <br />1 <br />13 <br />14 <br />ES-1 <br />(3 <br />) <br /> <br />S <br />O <br />L <br />A <br />R <br />E <br />D <br />G <br />E <br /> <br />B <br />A <br />T <br />- <br />1 <br />0 <br />K <br />1 <br />P <br /> <br />B <br />A <br />T <br />T <br />E <br />R <br />I <br />E <br />( <br />S <br />) <br />ST <br />R <br />- <br />6 <br />. <br />1 <br />. <br />A <br /> <br />- <br /> <br />( <br />1 <br />4 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />4 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />6 <br />. <br />1 <br />. <br />B <br /> <br />- <br /> <br />( <br />1 <br />4 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />4 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ES-2 <br />DC-6.1.1 <br />SO <br />L <br />A <br />R <br />3 <br />16 BA <br />T <br />T <br />E <br />R <br />Y <br />7 <br />12 <br />4 <br />A-B <br />40A <br />INV-6.1 <br />+- <br />18 <br />14 <br />1 <br />13 <br />14 <br />ES-1 <br />(3 <br />) <br /> <br />S <br />O <br />L <br />A <br />R <br />E <br />D <br />G <br />E <br /> <br />B <br />A <br />T <br />- <br />1 <br />0 <br />K <br />1 <br />P <br /> <br />B <br />A <br />T <br />T <br />E <br />R <br />I <br />E <br />( <br />S <br />) <br />ST <br />R <br />- <br />6 <br />. <br />2 <br />. <br />A <br /> <br />- <br /> <br />( <br />1 <br />4 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />4 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />6 <br />. <br />2 <br />. <br />B <br /> <br />- <br /> <br />( <br />1 <br />4 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />4 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ES-2 <br />DC-6.2.2 <br />SO <br />L <br />A <br />R <br />3 <br />16 BA <br />T <br />T <br />E <br />R <br />Y <br />7 <br />12 <br />4 <br />A-B <br />40A <br />INV-6.2 <br />6 <br />LC-6.1 <br />6 <br />8 <br />5 <br />(N) ACDS-2 SYSTEM AC DISCONNECT <br />SWITCH,, SQUARE D, VHU363RB, 600V RATED, <br />240V OPERATIONAL, 100A, 3 POLE, <br />NON-FUSIBLE, NEMA 3R. VISIBLE, LOCKABLE. <br />SEE REFERENCE SHEETS FOR KAIC RATING. <br />AC-6.2 <br />M9 <br />4 <br />(N) SCE PV PRODUCTION METER SOCKET <br />ADDRESS: 1403 S MINNIE ST UNIT# MTR01, <br />COOPER B-LINE, 114TB, 100 A, SERVICE 1 <br />PHASE 3 WIRE 120/240 VAC, NEMA 3R <br />AC-6.2 <br />10 <br />3 <br />(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT <br />SWITCH, SQUARE D, VH223NRB, 240V RATED, <br />240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, <br />NEMA 3R, OR EQUIVALENT ON THE UTILITIES <br />APPROVED LIST. VISIBLE, LOCKABLE. <br />CLASS J FUSE, 200KAIC RATING. <br />A-B <br />80AAC-6.1 <br />A INTERCONNECTION LOCATION <br />NTS1403 S MINNIE ST UNIT# MTR01 <br />POI-6 DC STRING SCHEDULE <br />STR-A STR-B <br />TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD%MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES <br />DC-6.1.1 INV-6.1 75 0.71%410 14 U650 8 / 16¹80 0.71%410 14 U650 8 / 16¹ <br />DC-6.2.2 INV-6.2 85 0.81%410 14 U650 8 / 16¹50 0.45%410 14 U650 8 / 16¹ <br />¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION <br />² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS <br />³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) <br />⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. <br />POI-6 DC WIRE SCHEDULE <br />TAG WIRE GAUGE CONDUCTOR <br />JACKET <br />MAX ISC 1.25 X MAX <br />CIRCUIT AMPS <br />CIRCUIT FUSE <br />RATING <br />CCC PER <br />CONDUIT <br />MAX AMBIENT <br />TEMP (C) <br />C.O.U TEMP. <br />DERATE <br />C.O.U CONDUIT <br />FILL DERATE <br />75°C AMPACITY COMPLIES WITH <br />690.8(B)(1) <br />90°C AMPACITY <br />WITH C.O.U <br />COMPLIES WITH <br />690.8(B)(2) <br />FAULT CURRENT <br />FROM PARALLEL <br />STRINGS <br />COMPLIES WITH <br />690.9(A) <br /> GROUNDING <br />PER CONDUIT <br />GROUNDING ³EMT RMC PVC 40 PVC 80 <br />DC-6.1.1 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4" <br />DC-6.2.2 CU #10 THWN2 15 18.75 NONE 4 38 91%80%35 YES 29.1 YES 15 YES 2 CU #10 3/4"3/4"3/4"3/4" <br />LINE SIDE TAP VIA POLARIS TAPS <br />(POINT OF INTERCONNECTION) <br />SCE METER <br />1. PV MODULES (56) QCELLS NORTH <br />AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 <br />2. (56) SOLAREDGE DC OPTIMIZER U650 <br />3. DC PV AND ESS CONNECTION UNIT W/ <br />INTEGRAL LOAD BREAK DISCONNECT <br />4. (2) SOLAREDGE SE7600H-US HOME HUB <br />[240V] [SI1-SB] [CRD-PCS NEM], 7,600W, <br />240VAC, 1ø, 3W <br />5. (N) REVENUE GRADE METER, 1ø, <br />INTERGRATED RGM, W/ NOT REQUIRED <br />CTS <br />6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC, <br />MIN. 10KAIC, NEMA 3R <br />7. NOT USED <br />8.(N) ACDS-2 SYSTEM AC DISCONNECT <br />SWITCH, SQUARE D, VHU363RB, 600V <br />RATED, 240V OPERATIONAL, 100A, 3 POLE, <br />NON-FUSIBLE, NEMA 3R. SEE REFERENCE <br />SHEETS FOR KAIC RATING. <br />9. (N) SCE PV PRODUCTION METER SOCKET <br />ADDRESS: 1403 S MINNIE ST UNIT# MTR01, <br />COOPER B-LINE, 114TB, 100A, SERVICE: 1 <br />PHASE 3 WIRE 120/240 VAC, # JAW, NEMA <br />3R, EUSERC: 304 <br />10. (N) ACDS-1 SYSTEM UTILITY AC <br />DISCONNECT SWITCH, SQUARE D, <br />VH223NRB, 240V RATED, 240V <br />OPERATIONAL, 100A, 2 POLE, FUSIBLE, <br />NEMA 3R, OR EQUIVALENT ON THE <br />UTILITIES APPROVED LIST. <br /> CLASS J FUSE, 200KAIC RATING. <br /> 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 <br />WIRE 120/240 VAC, 100A <br />12. (N) CELL-B-R05-US-S-S2 CELL CARD <br />13. (6) SOLAREDGE BAT-10K1P BATTERIES, <br />9.70KWH, 5,000DCW, NEMA 3R, MOUNTED <br />TO WALL OR MANUFACTURER FLOOR <br />MOUNT KIT <br />14. NOT USED <br />15. (N) POLARIS BLOCKS <br />16. NOT USED <br />1.(E) MAIN SWITCHGEAR AND (N) POINT OF <br />AC INTERCONNECTION. ALL <br />CONNECTIONS MADE INSIDE (E) <br />SWITCHGEAR AT OTHER THAN CIRCUIT <br />BREAKERS OR FUSED SWITCHES LISTED <br />FOR USE WITH THAT SWITCHGEAR SHALL <br />BE PERFORMED FOLLOWING <br />MANUFACTURERS INSTRUCTIONS OR BE <br />RE-LISTED BY A NRTL. ALL TERMINATIONS <br />OF ALUMINUM CONDUCTORS SHALL BE <br />WITH HIGH PRESS CRIMP LUGS ONLY. <br />WARNING LABEL DETAIL 1/E800 <br />2.(E) UTILITY TENANT LOAD METER. UTILITY <br />REFERENCE METER NUMBER: <br />222013-048110 <br />3.(N) PV SYSTEM UTILITY AC DISCONNECT <br />'ACDS-1'. WARNING LABEL DETAIL 1/E810 <br />4.(N) UTILITY BIDIRECTIONAL KWH METER. <br />WARNING LABEL DETAIL 1/E810 <br />5.(N) PV SYSTEM MAINTENANCE AC <br />DISCONNECT 'ACDS-2'. WARNING LABEL <br />DETAIL 2/E800 & 1/E810 <br />6.NOT USED <br />7.(N) GRID-INTERACTIVE PV INVERTER <br />LISTED TO UL 1741 WITH GROUND FAULT <br />DETECTION & INTERRUPTION. WARNING <br />LABEL DETAIL 15/E800. <br />8.NOT USED <br />9.NOT USED <br />10.FOR SUPPLY SIDE CONNECTIONS, A <br />PLAQUE SHALL BE INSTALLED AT THE <br />MAIN SERVICE DISCONNECTING DEVICE <br />AND THE PV SYSTEM UTILITY AC <br />DISCONNECT INDICATING THE LOCATION <br />OF THE RESPECTIVE SERVICE <br />DISCONNECT. WARNING LABEL DETAIL <br />1/E800 & 1/E810 <br />11.NOT USED <br />12.CONDUCTORS RUN IN PARALLEL SHALL <br />BE INSTALLED PER ART 310.4/310.10(G) <br />AND 250.122 (F). <br />13.NOT USED <br />14.NEW PULL/JUNCTION BOXES. PROVIDE <br />SERVICE LOOP IN ALL DC BRANCH <br />CONDUCTORS SOURCED FROM <br />ROOFTOPS, MIN LOOP RADIUS = 12X <br />CONDUCTOR DIAMETER. <br />15.NOT USED <br />16.(N) INVERTER INTERNAL DC DISCONNECT <br />SWITCH(ES). WARNING LABEL DETAIL <br />3/E800 <br />17.NOT USED <br />18.(N) PV MODULE LISTED TO UL 1703. <br />19.EXTRA MODULES THAT ARE UNABLE TO <br />BE PAIRED WILL HAVE THEIR OWN <br />OPTIMIZER. <br />20.(N) COMMUNICATION WIRING TO FOLLOW <br />MANUFACTURING SPECIFICATIONS. <br />21.DURING UTILITY GRID OUTAGE THE PV <br />GENERATION AND BESS WILL <br />DISCONNECT FROM THE GRID AND <br />REMAIN DISCONNECTED UNTIL GRID <br />VOLTAGE IS RESTORED TO THE <br />ACCEPTED MEASURE. <br />22.BATTERY AC OUTPUT POWER IS LIMITED <br />TO THE CORRESPONDING INVERTER OR <br />TOTAL BATTERIES CONNECTED TO A <br />SINGLE INVERTER,WHICHEVER IS LOWER. <br />23.BATTERIES SHOULD NOT BE INSTALLED IN <br />DIRECT SUNLIGHT OR LOCATIONS <br />SUBJECTED TO WATER SPRAY. <br />SPRINKLERS SHOULD BE DIVERTED <br />WHEN NECESSARY. <br />24.BATTERIES CAN COMMUNICATE <br />WIRELESSLY OR VIA RS-485 TO INVERTER. <br />BATTERIES WITHIN 150' (IDEALLY 50') OF <br />RESPECTIVE INVERTER CAN USE <br />WIRELESS COMMUNICATIONS VIA SEDG <br />HOME NETWORK CARD. <br />25.COMBINED PV AND BESS OUTPUT POWER <br />IS LIMITED TO THE INVERTER AC RATING. <br />26.SOLAREDGE ENERGY BANK MAY BE <br />WALL, FLOOR, OR PAD MOUNTED <br />INDIVIDUALLY OR IN GROUPS OF (2), (3), <br />OR (4) UTILIZING THE SOLAREDGE FLOOR <br />MOUNT STAND. ENERGY BANK MEETS <br />THE UNIT LEVEL PERFORMANCE <br />CRITERIA OF UL 9540A, ALLOWING <br />ENERGY BANK TO BE STACKED FRONT TO <br />BACK AS LONG AS THE CLEARANCE <br />REQUIREMENTS ARE FOLLOWED TO <br />ALLOW FOR AIR FLOW AROUND THE <br />UNITS. <br />M <br />M <br />M <br />M <br />M FACILITY <br />LOADS <br />(E) TENANT <br />METERS (TYP.) <br />(N) POLARIS <br />BLOCK <br />- <br />A <br />11101 <br />15 <br />100A <br />UTILITY METER REFERENCE NUMBER: <br />222013-048110 <br />SCE UTILITY GRID 240V, 1ø,3W <br />RMC ONLY <br />E401 <br />G <br />BLDG <br />1403 <br />GEC <br />E500 <br />D <br />E401 <br />G <br />BLDG <br />1403 <br />GEC <br />E500 <br />D <br />AHJ NOTES: <br />1.FUSED AC DISCONNECTS MUST BE SUSE RATED WITH A MAIN BONDING JUMPER <br />INSTALLED. CEC 230.82(6) <br />2.THE "GROUND" WIRE OF FUSED AC DISCONNECTS IS A GROUNDING ELECTRODE <br />CONDUCTOR TO BE BONDED TO THE GEC SYSTEM OF THE BUILDING <br />3.DISCONNECTS MUST BE WITHIN RMC TO THE POI. THE DISCONNECT AND THE <br />SUPPLY-SIDE POI MUST BE SEALED BY SCE. THIS IS CITY POLICY FOR SE <br />CONDUCTORS TO MINIMIZE POWER THEFT AND DAMAGE. <br />TO <br />GEC <br />EGCRMC ONLY <br />RMC ONLY <br />WEATHERHEAD - UTILITY <br />TERMINATION POINT <br />SCE CECTION <br />CUSTOMER <br />SECTION <br />DISTANCE FROM FUSED <br />ACD TO POI ~ 5 FT <br />UTILITY TERMINATION <br />POI-6 AC WIRE SCHEDULE <br />LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE <br />CONDUCTOR <br />NEUTRAL <br />CONDUCTOR <br />GROUNDING <br />CONDUCTOR <br />CONDUCTORS PER <br />PHASE <br />CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/ <br />C.O.U <br />C.O.U TEMP <br />DERATE <br />C.O.U CONDUIT <br />FILL <br />CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 <br />INV-6.1 LC-6.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%151.1%2,851 2,649 1/2"1/2"3/4"3/4" <br />INV-6.2 LC-6.1 240 A-B 31.7 39.6 40 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.10%151.1%2,851 2,649 1/2"1/2"3/4"3/4" <br />LC-6.1 AC-6.2 240 A-B 63.3 79.1 80 CU #4 CU #8 CU #8 1 1 85 95 86.5 91%100%10 0.16%--3,041 2,851 1"1"1"1" <br />AC-6.2 AC-6.1 240 A-B 63.3 79.1 80 CU #4 CU #8 CU #8 1 1 85 95 86.5 91%100%10 0.16%--3,258 3,041 1"1"1"1" <br />AC-6.1 POI-6.6 240 A-B 63.3 79.1 80 CU #4 CU #4 CU #8 1 1 85 95 86.5 91%100%5 0.08%--42,000 28,771 1"1"1"1 1/4" <br />D:\PROJECTS\FEB\19\UPLOAD\WILSHIRE MINNIE\CAD FILE\WILSHIRE MINNIE\WILSHIRE MINNIE_NEW(1).DWG <br />POI-6 ONE LINE <br />CONTRACTOR: <br />ENGINEERING APPROVAL: <br />600 CALIFORNIA ST #1800, SAN <br />FRANCISCO, CA 94104 <br />CA CL #750184 <br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT <br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. <br />WILSHIRE MINNIE <br />1235 E WILSHIRE AVE, <br />SANTA ANA, CA 92707, USA <br />APN:014-251-49/014-251-50 <br />DEVELOPER: <br />C&C DEVELOPMENT <br />DESCRIPTION DATE REV <br />0ORIGINAL06/23/25 <br />BAHJ COMMENTS #2 12/10/25 <br />CCAHNGED DECK MOUNT TO RAFTER MOUNT 02/18/26 <br />PROJECT DETAILS: <br />PV SYSTEM: <br />·259.12 kW DC <br />·186.2 kW AC <br />·241.45 CEC AC <br />ENERGY STORAGE: <br />·184.8 kW AC <br />·523.8 kWH <br />E605 <br />SHEET SIZE: <br />REVISION: <br />SHEET TITLE: <br />36" X 24" (ARCH D) <br />DESIGNER: <br />FINS_TM <br />C <br />PROJECT NUMBER: <br /> PROP-001235 <br />ASYSTEM DOWNSIZED 09/05/25 <br />AHJ COMMENTS #1 & <br />#ESTAMP <br />WILSHIRE MINNIE <br />1403 S MINNIE ST UNIT# MTR01 <br />APN: 014-251-49 <br />DEVELOPER: <br /> C&C DEVELOPMENT