##KEYED NOTES#EQUIPMENT NOTES# <br />A INTERCONNECTION LOCATION <br />NTS <br />COMMUNICATION <br />CIRCUIT IDENTIFIER <br />##KEYED NOTES#EQUIPMENT NOTES# <br />A INTERCONNECTION LOCATION <br />NTS <br />COMMUNICATION <br />CIRCUIT IDENTIFIER <br />SYSTEM SUMMARY <br />15.20 ACKW | 22.14 DCKW | 20.63 CECKW <br /> 15.20 BESS ACKW | 58.20 BESS KWH <br />TOTAL FAULT CURRENTS <br />UTILITY: 42,000A | GENERATORS: 156.2A <br />+ -18 <br />14 <br />1 13 <br />14 <br />ES-1 <br />(3 <br />) <br /> <br />S <br />O <br />L <br />A <br />R <br />E <br />D <br />G <br />E <br /> <br />B <br />A <br />T <br />- <br />1 <br />0 <br />K <br />1 <br />P <br /> <br />B <br />A <br />T <br />T <br />E <br />R <br />I <br />E <br />( <br />S <br />) <br />ST <br />R <br />- <br />8 <br />. <br />1 <br />. <br />A <br /> <br />- <br /> <br />( <br />1 <br />3 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />3 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />8 <br />. <br />1 <br />. <br />B <br /> <br />- <br /> <br />( <br />1 <br />4 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />4 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ES-2 <br />DC-8.1.1 <br />SO <br />L <br />A <br />R <br />3 <br />16 BA <br />T <br />T <br />E <br />R <br />Y <br />7 <br />12 <br />4 <br />A-B <br />40A <br />INV-8.1 <br />+ -18 <br />14 <br />1 13 <br />14 <br />ES-1 <br />(3 <br />) <br /> <br />S <br />O <br />L <br />A <br />R <br />E <br />D <br />G <br />E <br /> <br />B <br />A <br />T <br />- <br />1 <br />0 <br />K <br />1 <br />P <br /> <br />B <br />A <br />T <br />T <br />E <br />R <br />I <br />E <br />( <br />S <br />) <br />ST <br />R <br />- <br />8 <br />. <br />2 <br />. <br />A <br /> <br />- <br /> <br />( <br />1 <br />3 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />3 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />8 <br />. <br />2 <br />. <br />B <br /> <br />- <br /> <br />( <br />1 <br />4 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />4 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ES-2 <br />DC-8.2.2 <br />SO <br />L <br />A <br />R <br />3 <br />16 BA <br />T <br />T <br />E <br />R <br />Y <br />7 <br />12 <br />4 <br />A-B <br />40A <br />INV-8.2 <br />6 <br />LC-8.1 <br />6 <br />8 <br />5 (N) ACDS-2 SYSTEM AC DISCONNECT <br />SWITCH,, SQUARE D, VHU363RB, 600V RATED, <br />240V OPERATIONAL, 100A, 3 POLE, <br />NON-FUSIBLE, NEMA 3R. SEE REFERENCE <br />SHEETS FOR KAIC RATING. <br />AC-8.2 <br />M9 <br />4 <br />(N) SCE PV PRODUCTION METER SOCKET <br />ADDRESS: 1235 E WILSHIRE AVE BLDG 1413 <br />SOMAH8, COOPER B-LINE, 114TB, 100 A, <br />SERVICE 1 PHASE 3 WIRE 120/240 VAC, NEMA <br />3R <br />AC-8.2 <br />10 <br />3 <br />(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT <br />SWITCH, SQUARE D, VH223NRB, 240V RATED, <br />240V OPERATIONAL, 100A, 2 POLE, FUSIBLE, <br />NEMA 3R, OR EQUIVALENT ON THE UTILITIES <br />APPROVED LIST. CLASS R FUSE WITH <br />REJECTION CLIPS OR CLASS J FOR 200KAIC <br />RATING. <br />A-B <br />80AAC-8.1 <br />1. PV MODULES (54) QCELLS NORTH <br />AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 <br />2. (54) SOLAREDGE DC OPTIMIZER U650 <br />3. DC PV AND ESS CONNECTION UNIT W/ <br />INTEGRAL LOAD BREAK DISCONNECT <br />4. (2) SOLAREDGE SE7600H-US HOME HUB <br />[SI1-SB], 7,600W, 240VAC, 1ø, 3W <br />5. (N) REVENUE GRADE METER, 1ø, <br />INTERGRATED RGM, W/ NOT REQUIRED <br />CTS <br />6. (1) LOAD CENTER, 100A, 1ø, MIN.240VAC, <br />MIN. 22KAIC, NEMA 3R <br />7. NOT USED <br />8. (N) ACDS-2 SYSTEM AC DISCONNECT <br />SWITCH, SQUARE D, VHU363RB, 600V <br />RATED, 240V OPERATIONAL, 100A, 3 POLE, <br />NON-FUSIBLE, NEMA 3R. SEE REFERENCE <br />SHEETS FOR KAIC RATING. <br />9. (N) SCE PV PRODUCTION METER SOCKET <br />ADDRESS: 1235 E WILSHIRE AVE BLDG <br />1413 SOMAH8, COOPER B-LINE, 114TB, <br />100A, SERVICE: 1 PHASE 3 WIRE 120/240 <br />VAC, # JAW, NEMA 3R, EUSERC: 304 <br />10. (N) ACDS-1 SYSTEM UTILITY AC <br />DISCONNECT SWITCH, SQUARE D, <br />VH223NRB, 240V RATED, 240V <br />OPERATIONAL, 100A, 2 POLE, FUSIBLE, <br />NEMA 3R, OR EQUIVALENT ON THE <br />UTILITIES APPROVED LIST. CLASS R FUSE <br />WITH REJECTION CLIPS OR CLASS J FOR <br />200KAIC RATING. <br /> 11. (E) MAIN SERVICE EQUIPMENT: 1 PHASE 3 <br />WIRE 120/240 VAC, 100A <br />12. MANUFACTURER INTERGRATED CELL <br />CARD <br />13. (6) SOLAREDGE BAT-10K1P BATTERIES, <br />9.70KWH, 5,000DCW, NEMA 3R, MOUNTED <br />TO WALL OR MANUFACTURER FLOOR <br />MOUNT KIT <br />14. NOT USED <br />15. (N) POLARIS BLOCKS <br />16. NOT USED <br />1. (E) MAIN SWITCHGEAR AND (N) POINT OF <br />AC INTERCONNECTION. ALL <br />CONNECTIONS MADE INSIDE (E) <br />SWITCHGEAR AT OTHER THAN CIRCUIT <br />BREAKERS OR FUSED SWITCHES LISTED <br />FOR USE WITH THAT SWITCHGEAR SHALL <br />BE PERFORMED FOLLOWING <br />MANUFACTURERS INSTRUCTIONS OR BE <br />RE-LISTED BY A NRTL. ALL TERMINATIONS <br />OF ALUMINUM CONDUCTORS SHALL BE <br />WITH HIGH PRESS CRIMP LUGS ONLY. <br />WARNING LABEL DETAIL 1/E800 <br />2. (E) UTILITY TENANT LOAD METER. UTILITY <br />REFERENCE METER NUMBER: <br />222013-048131 <br />3. (N) PV SYSTEM UTILITY AC DISCONNECT <br />'ACDS-1'. WARNING LABEL DETAIL 1/E810 <br />4. (N) UTILITY BIDIRECTIONAL KWH METER. <br />WARNING LABEL DETAIL 1/E810 <br />5. (N) PV SYSTEM MAINTENANCE AC <br />DISCONNECT 'ACDS-2'. WARNING LABEL <br />DETAIL 2/E800 & 1/E810 <br />6. NOT USED <br />7. (N) GRID-INTERACTIVE PV INVERTER <br />LISTED TO UL 1741 WITH GROUND FAULT <br />DETECTION & INTERRUPTION. WARNING <br />LABEL DETAIL 15/E800. <br />8. NOT USED <br />9. NOT USED <br />10. FOR SUPPLY SIDE CONNECTIONS, A <br />PLAQUE SHALL BE INSTALLED AT THE <br />MAIN SERVICE DISCONNECTING DEVICE <br />AND THE PV SYSTEM UTILITY AC <br />DISCONNECT INDICATING THE LOCATION <br />OF THE RESPECTIVE SERVICE <br />DISCONNECT. WARNING LABEL DETAIL <br />1/E800 & 1/E810 <br />11. NOT USED <br />12. CONDUCTORS RUN IN PARALLEL SHALL <br />BE INSTALLED PER ART 310.4/310.10(G) <br />AND 250.122 (F). <br />13. NOT USED <br />14. NEW PULL/JUNCTION BOXES. PROVIDE <br />SERVICE LOOP IN ALL DC BRANCH <br />CONDUCTORS SOURCED FROM <br />ROOFTOPS, MIN LOOP RADIUS = 12X <br />CONDUCTOR DIAMETER. <br />15. NOT USED <br />16. (N) INVERTER INTERNAL DC DISCONNECT <br />SWITCH(ES). WARNING LABEL DETAIL <br />3/E800 <br />17. NOT USED <br />18. (N) PV MODULE LISTED TO UL 1703. <br />19. EXTRA MODULES THAT ARE UNABLE TO <br />BE PAIRED WILL HAVE THEIR OWN <br />OPTIMIZER. <br />20. (N) COMMUNICATION WIRING TO FOLLOW <br />MANUFACTURING SPECIFICATIONS. <br />21. DURING UTILITY GRID OUTAGE THE PV <br />GENERATION AND BESS WILL <br />DISCONNECT FROM THE GRID AND <br />REMAIN DISCONNECTED UNTIL GRID <br />VOLTAGE IS RESTORED TO THE <br />ACCEPTED MEASURE. <br />22. BATTERY AC OUTPUT POWER IS LIMITED <br />TO THE CORRESPONDING INVERTER OR <br />TOTAL BATTERIES CONNECTED TO A <br />SINGLE INVERTER,WHICHEVER IS LOWER. <br />23. BATTERIES SHOULD NOT BE INSTALLED IN <br />DIRECT SUNLIGHT OR LOCATIONS <br />SUBJECTED TO WATER SPRAY. <br />SPRINKLERS SHOULD BE DIVERTED <br />WHEN NECESSARY. <br />24. BATTERIES CAN COMMUNICATE <br />WIRELESSLY OR VIA RS-485 TO INVERTER. <br />BATTERIES WITHIN 150' (IDEALLY 50') OF <br />RESPECTIVE INVERTER CAN USE <br />WIRELESS COMMUNICATIONS VIA SEDG <br />HOME NETWORK CARD. <br />25. COMBINED PV AND BESS OUTPUT POWER <br />IS LIMITED TO THE INVERTER AC RATING. <br />26. NOT USED <br /># <br />CAT5E 600V RATED SHIELDED CABLE. <br />INSTALLER SHALL FOLLOW <br />MANUFACTURES RECOMMENDATION FOR <br />WIRE SIZING BASED ON LENGTH. <br />EQUIPMENT TYPE <br />SYSTEM IDENTIFIER X INDICATES LETTERS <br /># INDICATES NUMBERS <br />XX-#.# <br />1235 E WILSHIRE AVE BLDG 1413 SOMAH8 <br />POI-8 DC STRING SCHEDULE <br />STR-A STR-B <br />TAG DESTINATION CIRCUIT LENGTH ²VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES CIRCUIT LENGTH ²VD% MODULE WATTAGE MODULE QTY OPTIMIZER MIN/MAX MODULES <br />DC-8.1.1 INV-8.1 120 1.06%410 13 U650 8 / 16¹50 0.45%410 14 U650 8 / 16¹ <br />DC-8.2.2 INV-8.2 95 0.84%410 13 U650 8 / 16¹95 0.85%410 14 U650 8 / 16¹ <br />¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION <br />² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS <br />³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) <br />⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. <br />POI-8 DC WIRE SCHEDULE <br />TAG WIRE GAUGE CONDUCTOR JACKET CCC PER CONDUIT GROUNDING ³EMT RMC PVC 40 PVC 80 <br />DC-8.1.1 CU #10 THWN2 4 CU #10 3/4"3/4"3/4"3/4" <br />DC-8.2.2 CU #10 THWN2 4 CU #10 3/4"3/4"3/4"3/4" <br />POI-8 AC WIRE SCHEDULE <br />LABEL DESTINATION NOMINAL VAC LINE <br />SELECTION <br />FLA FLAX1.25 PHASE <br />CONDUCTOR <br />NEUTRAL <br />CONDUCTOR <br />GROUNDING <br />CONDUCTOR <br />CONDUCTORS <br />PER PHASE <br />CONDUIT QTY CIRCUIT <br />LENGTH ² <br />SEGMENT <br />VD% <br />DC/AC RATIO AFC START AFC END ⁴EMT IMC PVC 40 PVC 80 <br />INV-8.1 LC-8.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 145.7%4,918 4,346 1/2"1/2"3/4"3/4" <br />INV-8.2 LC-8.1 240 A-B 31.7 39.6 CU #8 CU #10 CU #10 1 1 5 0.10% 145.7%4,918 4,346 1/2"1/2"3/4"3/4" <br />LC-8.1 AC-8.2 240 A-B 63.3 79.1 CU #4 CU #8 CU #8 1 1 70 1.10%--19,967 4,918 1"1"1"1" <br />AC-8.2 AC-8.1 240 A-B 63.3 79.1 CU #4 CU #8 CU #8 1 1 7 0.11%--28,771 19,967 1"1"1"1" <br />AC-8.1 POI-8.8 240 A-B 63.3 79.1 CU #4 CU #4 CU #8 1 1 5 0.08%--42,000 28,771 1"1"1"1 1/4" <br />M <br />M <br />M <br />M <br />M FACILITY <br />LOADS <br />(N) TENANT <br />METERS (TYP.) <br />UTILITY METER REFERENCE NUMBER: <br />222013-048131 <br />SCE UTILITY GRID 240V, <br />1ø,3W <br />11101 <br />- <br />A <br />15 <br />(N) POLARIS <br />BLOCK <br />POLARIS SUPPLY SIDE TAP <br />POINT OF INTERCONNECTION <br />C:\USERS\EMILIANO.MORALES\DESKTOP\WORKING PROJECTS\1235_WILSHIRE_MINNIE\CD100\WILSHIRE MINNIE_WORKINGDOCS_V0\WILSHIRE MINNIE.DWG <br />POI-8 ONE LINE <br />CONTRACTOR: <br />ENGINEERING APPROVAL: <br />600 CALIFORNIA ST #1800, SAN <br />FRANCISCO, CA 94104 <br />CA CL #750184 <br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT <br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. <br />WILSHIRE MINNIE <br />1235 E WILSHIRE AVE, <br />SANTA ANA, CA 92707, USA <br />APN:014-251-49/014-251-50 <br />DEVELOPER: <br />C&C DEVELOPMENT <br />DESCRIPTION DATE REV <br />0ORIGINAL06/23/25 <br />PROJECT DETAILS: <br />PV SYSTEM: <br />·355.88 kW DC <br />·250.8 kW AC <br />·331.612 CEC AC <br />ENERGY STORAGE: <br />·243.2 kW AC <br />·756.6 kWH <br />E607 <br />SHEET SIZE: <br />REVISION: <br />SHEET TITLE: <br />36" X 24" (ARCH D) <br />DESIGNER: FINS_TM <br />ORIGINAL <br />CONTRACT NUMBER: <br />3003197607 <br />PJT #: PROP-001235