GENERAL NOTES: <br />1. DETAILS OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS THOSE <br />SHOWN FOR SIMILAR CONDITIONS. REFER TO THE TYPICAL DETAIL SHEETS FOR <br />TYPICAL DETAILS OF CONSTRUCTION. TYPICAL DETAILS APPLY TO ALL <br />CONSTRUCTION UNLESS SPECIFICALLY NOTED OR SHOWN OTHERWISE. WHERE <br />CONDITIONS REQUIRE MODIFICATIONS OF A TYPICAL DETAIL, THE CONTRACTOR <br />SHALL SUBMIT MODIFIED DETAIL FOR APPROVAL BY THE ENGINEER OF RECORD <br />PRIOR TO FABRICATION AND INSTALLATION. DETAILS OF CONSTRUCTION NOT SHOWN <br />SHALL BE OF SAME NATURE AS THOSE SHOWN FOR SIMILAR CONSTRUCTION. <br />2. CONTRACTOR SHALL CONSIDER THE PROJECT SPECIFICATIONS A PART OF THE <br />CONTRACT DOCUMENTS. WHERE INFORMATION IS CONFLICTING, SPECIFIC DETAILS <br />SHALL GOVERN OVER TYPICAL DETAILS WHICH SHALL GOVERN OVER THESE NOTES <br />WHICH SHALL GOVERN OVER SPECIFICATIONS. <br />3. REFER TO THE PROJECT SPECIFICATIONS FOR SHOP DRAWING REQUIREMENTS AND <br />SUBMITTALS. <br />4. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST <br />ARCHITECTURAL DIMENSIONS. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE <br />OMITTED OR NOT CLEAR, CONTACT THE ARCHITECT (ARCH) OR STRUCTURAL <br />ENGINEER OF RECORD (SEOR). ALL DIMENSIONS RELATED TO EXISTING CONDITIONS <br />SHALL BE FIELD VERIFIED BY THE CONTRACTOR. DIMENSIONS ARE TO THE FACE OF <br />STUDS, AND TO CENTERLINE OF COLUMNS UNO. <br />5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY NOTIFY THE SEOR OF <br />ANY CONFLICTS BETWEEN THE STRUCTURAL DRAWINGS AND OTHER DRAWINGS; OR <br />EXISTING CONDITIONS NOT SHOWN OR DIFFERENT FROM THOSE SHOWN ON <br />DRAWINGS PRIOR TO COMMENCEMENT OF WORK. THE CONTRACTOR IS NOT TO <br />ORDER MATERIAL OR CONSTRUCT ANY PORTION OF THE BUILDING THAT IS IN <br />CONFLICT UNTIL THE CONFLICT IS RESOLVED WITH THE AFFECTED PARTIES. <br />6. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED <br />STRUCTURE. UNLESS OTHERWISE SHOWN THEY DO NOT INDICATE METHOD OF <br />CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO <br />PROTECT THE CONSTRUCTION AND ALL ADJACENT PROPERTIES DURING <br />CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT ARE NOT LIMITED TO <br />BRACING, SHORING OF LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. <br />OBSERVATION VISITS TO THE SITE BY THE ARCHITECT OR SEOR SHALL NOT INCLUDE <br />OBSERVATION OF THE ABOVE ITEMS. <br />7. SUBSTITUTION REQUESTS FOR MATERIALS SPECIFIED ON THE STRUCTURAL <br />DRAWINGS MAY BE CONSIDERED WITH MATERIALS HAVING EQUIVALENT OR GREATER <br />CAPACITY AND PERFORMANCE. CURRENT EVALUATION REPORTS AND PRODUCT <br />INFORMATION SHALL BE PROVIDED TO THE STRUCTURAL ENGINEER DEMONSTRATING <br />THE REQUIRED CAPACITY AND PERFORMANCE OF THE MATERIAL TO BE <br />SUBSTITUTED. WRITTEN APPROVAL FROM THE SEOR AND DSA SHALL BE OBTAINED <br />PRIOR TO THE SUBSTITUTION OF ANY MATERIAL SPECIFIED ON THE STRUCTURAL <br />DOCUMENTS. <br />8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT <br />SECTIONS OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE STATE OF <br />CALIFORNIA, LATEST EDITION, AND ALL OSHA REQUIREMENTS AS THEY APPLY TO <br />THIS PROJECT. THE ARCHITECT, SEOR AND DSA, AND THE OWNER DO NOT ACCEPT <br />ANY RESPONSIBILITY FOR THE CONTRACTOR'S FAILURE TO COMPLY WITH THESE <br />REQUIREMENTS. <br />9. NOT USED <br />10. CONSTRUCTION MATERIALS SHALL BE DISTRIBUTED WHEN PLACED ON THE <br />STRUCTURE SUCH THAT LOADS DO NOT EXCEED DESIGN LIVE LOADS OR RESULT IN <br />AN UNBALANCED CONDITION. <br />STRUCTURAL DESIGN CRITERIA: <br />1. CODES: <br />ALL WORK SHALL BE IN CONFORMANCE WITH THE CALIFORNIA BUILDING <br />CODE (CBC) 2022 EDITION, INCLUDING ALL AMENDMENTS. ALL STANDARDS <br />USED SHALL BE THE LATEST VERSION APPROVED BY THE CODE <br />ENFORCEMENT AGENCY ON THE DATE OF THE PERMIT ISSUANCE UNLESS <br />SPECIFICALLY NOTED OTHERWISE. <br />2. SEISMIC DESIGN INFORMATION: <br />3. WIND DESIGN INFORMATION: <br />4. LIVE LOADS <br />RESIDENTIAL: 40 PSF <br />ROOF: 20 PSF <br />BASIC WIND SPEED V = 95 MPH (3 SEC GUST) EXPOSURE C <br />I = 1.0 OCCUPANCY CAT. II SITE CLASS D <br />(DEFAULT) <br />SS = 1.323 S1 = 0.471 SDS = 1.508 SD1 = 0.532 <br />SEISMIC DESIGN CATEGORY = D <br />R = 6.5 Cd = 4 Ω <br />Kz = 0.85 Kd = 0.85 <br />AB ANCHOR BOLT <br />ABV ABOVE <br />ADDT'L ADDITIONAL <br />ADJ ADJACENT <br />AFF ABOVE FINISH FLOOR <br />ALT ALTERNATE <br />ARCH ARCHITECT(URAL) <br />BLDG BUILDING <br />BLKG BLOCKING <br />BLW BELOW <br />BM BEAM <br />BN BOUNDARY NAILING <br />B.O. BOTTOM OF <br />BOTT BOTTOM <br />BRG BEARING <br />BS BOTH SIDES <br />BTWN BETWEEN <br />C CAMBER <br />CIP CAST IN PLACE <br />CJ CONTROL/ <br />CONSTRUCTION JOINT <br />CL CENTERLINE <br />CLR CLEAR <br />CMU CONCRETE MASONRY <br />UNIT <br />COL COLUMN <br />CONC CONCRETE <br />CONN CONNECTION <br />CONT CONTINUOUS <br />CP COMPLETE <br />PENETRATION <br />CSK COUNTERSINK <br />CTR(D) CENTER(ED) <br />D BAR OR BOLT DIAMETER <br />DBL DOUBLE <br />DEMO DEMOLITION <br />DET DETAIL <br />DIA DIAMETER <br />DIAG DIAGONAL <br />DIM DIMENSION <br />DO DITTO <br />DWG DRAWING <br />(E) EXISTING <br />EA EACH <br />EF EACH FACE <br />EJ EXPANSION JOIST <br />EMBED EMBEDMENT <br />ELEC ELECTRICAL <br />ELEV ELEVATION <br />EN EDGE NAILING <br />E.O. EDGE OF <br />EOR ENGINEER OF RECORD <br />EQ EQUAL <br />EQUIP EQUIPMENT <br />ES EACH SIDE OR EDGE <br />SCREW <br />EW EACH WAY <br />EXP EXPANSION <br />EXT EXTERIOR <br />FIN FINISH <br />FLR FLOOR <br />FN FIELD NAILING <br />FND FOUNDATION <br />F.O. FACE OF <br />FS FAR SIDE OR FIELD <br />SCREW <br />FRMG FRAMING <br />FT FOOT OR FEET <br />FTG FOOTING <br />G GIRDER <br />GA GAGE <br />GALV GALVANIZED <br />HAB HEADED ANCHOR BOLT <br />HD HOLDDOWN <br />HDR HEADER <br />HGR HANGER <br />HK HOOK <br />HORIZ HORIZONTAL <br />HP HIGH POINT <br />HS HIGH STRENGTH <br />HSS HOLLOW STRUCTURAL <br />STEEL <br />HT HEIGHT <br />IN INCH <br />INT INTERIOR <br />JST JOIST <br />KLF KIPS PER LINEAR FOOT <br />KSL KIPS PER SQUARE FOOT <br />KSI KIPS PER SQUARE INCH <br />L ANGLE <br />LFRS LATERAL FORCE <br />RESISTING SYSTEM <br />LLH LONG LEG HORIZONTAL <br />LLV LONG LEG VERTICAL <br />LP LOW POINT <br />LWC LIGHTWEIGHT <br />CONCRETE <br />MAX MAXIMUM <br />MB MACHINE BOLT <br />MECH MECHANICAL <br />MFR MANUFACTURER <br />MIN MINIMUM <br />MTL METAL <br />(N) NEW <br />NS NEAR SIDE OR <br />NON-SHRINK <br />NTS NOT TO SCALE <br />NWC NORMAL WEIGHT <br />CONCRETE <br />OC ON CENTER <br />O.F. OUTSIDE FACE <br />OH OPPOSITE HAND <br />OPNG OPENING <br />PDF POWDER DRIVEN <br />FASTENER <br />PJ PANEL JOIST <br />PL PLATE <br />PLC(S) PLACE(S) <br />PLF POUND PER LINEAR <br />FOOT <br />PLYWD PLYWOOD <br />PREFAB PREFABRICATED <br />PSF POUND PER SQUARE <br />FOOT <br />PSI POUND PER SQUARE <br />INCH <br />PT PRESSURE TREATED OR <br />POST TENSION <br />QTY QUANTITY <br />RAD, R RADIUS <br />REF REFERENCE <br />REINF REINFORCING <br />REQD REQUIRED <br />SB SILL BOLT <br />SC SAW CUT OR SLIP <br />CRITICAL <br />SCHED SCHEDULE <br />SEOR STRUCTURAL ENGINEER <br />ON RECORD <br />SHTG SHEATHING <br />SIM SIMILAR <br />SMS SHEET METAL SCREW <br />SN SILL NAIL <br />SOG SLAB ON GRADE <br />SQ SQUARE <br />SS STAINLESS STEEL <br />STD STANDARD <br />STGRD STAGGERED <br />STIFF STIFFENER <br />STL STEEL <br />STRUCT STRUCTURAL <br />T&B TOP AND BOTTOM <br />THK THICK <br />T.O. TOP OF <br />TOM TOP OF MASONRY <br />TOS TOP OF STEEL <br />TYP TYPICAL <br />UNO UNLESS NOTED <br />OTHERWISE <br />VERT VERTICAL <br />W/ WITH <br />W/O WITHOUT <br />WF WIDE FLANGE <br />WLD WELDED <br />WO WHERE OCCURS <br />WP WORK POINT <br />WT WEIGHT <br />WWF WELDED WIRE FABRIC <br />Ø = DIAMETER = REFERENCE ELEVATION OR WORK POINT <br />TYPICAL ABBREVIATIONS <br />1. FIELD VERIFY ALL CONDITIONS & DIMENSIONS PRIOR TO SHOP DRAWING <br />PRODUCTION AND FABRICATION OF STRUCTURAL ELEMENTS. <br />2. WHERE ALL OTHER EXISTING CONDITIONS VARY SIGNIFICANTLY FROM THOSE <br />SHOWN ON THESE DRAWINGS, THE STRUCTURAL ENGINEER SHALL BE <br />NOTIFIED PRIOR TO CONTINUED CONSTRUCTION RELATED TO SUBJECT <br />CONDITIONS. <br />3. SHORE ALL EXISTING CONSTRUCTION AS REQUIRED. <br />EXISTING CONDITIONS NOTES: <br />1. THE ARCHITECT AND ENGINEERS ARE NOT RESPONSIBLE FOR THE LOCATIONS <br />OF EXISTING UNDERGROUND UTILITIES WHETHER OR NOT SHOWN ON THE <br />DRAWINGS. THE LOCATION OF ANY EXISTING UNDERGROUND UTILITIES <br />SHOWN ON THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL <br />IMMEDIATELY NOTIFY THE OWNER SHOULD ANY SUCH UNIDENTIFIED <br />CONDITIONS BE DISCOVERED. <br />2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES WHICH MAY <br />RESULT FROM HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ALL EXISTING <br />UNDERGROUND UTILITIES. <br />EXISTING UNDERGROUND UTILITY NOTES: <br />1. REINFORCING GRADES FOR CONCRETE OR MASONRY: <br />A. ALL BARS EXCEPT THOSE TO BE WELDED.............. ASTM A615, GRADE 60 <br />B. TIES AND STIRRUPS .................................................. ASTM A615, GRADE 60 <br />C. WELDED WIRE FABRIC ........................................... ASTM A185 <br />D. ALL BARS TO BE WELDED ........................................ ASTM A706, GRADE 60 <br />2. MAINTAIN MINIMUM CONCRETE COVER FROM FACE OF CONCRETE TO EDGE OF <br />ALL REINFORCEMENT AS FOLLOWS (UNO): <br />PROVIDE THE LARGEST COVER REQUIRED FOR ALL APPLICABLE CONDITIONS. <br />WHERE #3 STIRRUPS OR TIES ARE USED, ENSURE THAT THE COVER FOR <br />LONGITUDINAL BARS IS ADEQUATE. <br />3. REINFORCEMENT SHALL BE PLACED IN ACCORDANCE WITH THE CONCRETE <br />REINFORCING STEEL INSTITUTE (CRSI) "MANUAL OF STANDARD PRACTICE". <br />EACH REINFORCING BAR SHALL BE WIRED TO A CROSS BAR AT A MAXIMUM <br />SPACING OF 24" OC. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT <br />REINFORCING IN POSITIONS SHOWN ON THE PLANS. <br />4. SPLICES IN CONTINUOUS REINFORCEMENT, SHALL HAVE A CLASS "B" LAP <br />(1'-6" MIN) AND THE SPLICES IN ADJACENT BARS SHALL BE NOT LESS THAN 5'-0" <br />APART. BARS MAY BE WIRED TOGETHER AT SPLICES OR LAPS EXCEPT FOR TOP <br />REINFORCING OF BEAMS AND SLABS OR WHERE SPECIFICALLY DETAILED TO BE <br />SEPARATED. WELDED WIRE FABRIC SHALL BE LAPPED 12" MINIMUM. <br />5. ALL DOWELS, ANCHOR BOLTS AND OTHER HARDWARE TO BE SET IN CONCRETE <br />SHALL BE TIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NO WET <br />SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED ITEMS <br />SHALL BE PERFORMED DURING PLACEMENT OF CONCRETE. <br />6. BEND REINFORCING BARS COLD. <br />7. STEEL SHALL BE KEPT CLEAN AND FREE OF RUST. <br />8. DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME <br />GRADE, SIZE AND SPACING AS THE MAIN REINFORCING UNO. <br />9. ALL BARS SHALL BE MARKED SO THEIR IDENTIFICATION CAN BE MADE WHEN <br />THE FINAL IN PLACE INSPECTION IS MADE. <br />10. CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC <br />COATED WHEN RESTING ON EXPOSED SURFACES. <br />CONDITION COVER <br />CONCRETE POURED AGAINST EARTH 3" <br />CONCRETE POURED IN FORMS AND <br />EXPOSED TO WEATHER OR EARTH <br />- #6 BARS AND LARGER 2" <br />- #5 BARS AND SMALLER 1 1/2" <br />STRUCTURAL SLABS ON GRADE <br />- FROM BOTTOM OF SLAB 2" <br />- FROM TOP OF SLAB 1 1/2" <br />OTHER CONCRETE NOT EXPOSED TO WEATHER <br />OR EARTH FOR #11 BARS AND SMALLER <br />REINFORCING STEEL NOTES: <br />3/4" <br />1. CONCRETE SHALL BE MIXED, PLACED AND CURED IN ACCORDANCE WITH ACI <br />318, 2019 EDITION, AND PROJECT SPECIFICATIONS. <br />2. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN <br />WALLS) SO AS TO CAUSE SEGREGATION OF AGGREGATES. IN SUCH CASES, <br />HOPPERS AND VERTICAL CHUTES OR TRUNKS SHALL BE USED. CHUTES OR <br />TRUNKS SHALL BE OF VARIABLE LENGTHS SO THAT FREE UNCONFINED FALL OF <br />CONCRETE SHALL NOT EXCEED SIX FEET. A SUFFICIENT NUMBER OF CHUTES <br />OR TRUNKS SHALL BE USED TO ENSURE THE CONCRETE IS KEPT LEVEL AT ALL <br />TIMES. <br />3. CONSTRUCTION JOINTS SHALL BE CLEANED AND ROUGHENED BY REMOVING <br />THE ENTIRE SURFACE TO EXPOSE CLEAN AGGREGATE SOLIDLY EMBEDDED IN <br />THE MORTAR MATRIX. SEE PLANS AND DETAILS FOR LOCATION AND TYPE OF <br />CONSTRUCTION JOINT. LOCATIONS OF ADDITIONAL CONSTRUCTION JOINTS <br />NOT SHOWN ON THESE PLANS SHALL BE SUBMITTED FOR APPROVAL BY THE <br />EOR PRIOR TO PLACING ANY CONCRETE. <br />4. STRUCTURAL CONCRETE SHALL MEET THE FOLLOWING DESIGN CRITERIA: <br />a. MAXIMUM DRY WEIGHT OF LIGHTWEIGHT CONCRETE SHALL BE 110 PCF, <br />UNLESS APPROVED BY SEOR. <br />b. SLUMP MEASURED PRIOR TO SUPERPLASTICIZER, WHERE OCCURS. <br />c. USE TYPE II/V CEMENT. <br />5. CONCRETE MIX DESIGN AND TESTING SHALL MEET THE REQUIREMENTS OF THE <br />BUILDING CODE, AND SPECIFICATIONS. ALL CONCRETE MIXES SHALL BE <br />DESIGNED BY A RECOGNIZED TESTING LAB STAMPED AND SEALED BY A <br />LICENSED CALIFORNIA CIVIL ENGINEER AND SUBMITTED TO THE SEOR FOR <br />REVIEW PRIOR TO CONCRETE PLACEMENT. STRUCTURAL CONCRETE MIXES <br />SHALL CONSIST OF 5 SACK MINIMUM UNO. <br />6. AGGREGATES IN NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33 <br />(HARDROCK). AGGREGATES IN LIGHT WEIGHT CONCRETE SHALL CONFORM TO <br />ASTM C-330. <br />7. COMPRESSIVE STRENGTH TEST REPORTS SHALL BE SUBMITTED TO THE <br />BUILDING DEPARTMENT AND THE SEOR. <br />8. PORTLAND CEMENT SHALL BE TYPE II/V FOR ALL CONCRETE CONFORMING TO <br />ASTM C150, LOW ALKALI. MILL TESTS WITH CERTIFICATES OF COMPLIANCE <br />SHALL BE SUBMITTED. <br />9. FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 CLASS N OR F <br />MAY BE USED AS A PARTIAL SUBSTITUTION FOR PORTLAND CEMENT UP TO A <br />MAXIMUM OF 15% TOTAL CEMENTITIOUS MATERIALS BY WEIGHT IF THE MIX <br />DESIGN IS PROPORTIONED PER ACI 318, SECTION 5.3. <br />10. CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C94. <br />11. NOT USED. <br />12. DRYPACK OR NONSHRINK GROUT SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2 TIMES THE SUPPORTING CONCRETE <br />STRENGTH, AND SHALL BE OF MASTERFLOW 713, FIVE STAR GROUT, SIKA <br />GROUT 212, EMBECO 636, OR APPROVED EQUAL. FOR THICK GROUT LAYERS <br />FOLLOW MANUFACTURER'S GUIDELINES TO ATTAIN THE REQUIRED STRENGTH, <br />WHICH MAY INCLUDE THE ADDITION OF PEA GRAVEL. <br />13. DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER <br />USED IN MIX SHALL BE CLEAN AND POTABLE. <br />14. PRIOR TO ERECTING ANY ELEMENTS THAT LOAD THE FOUNDATION, CONCRETE <br />MUST REACH AN UNCONFINED COMPRESSION STRENGTH OF 2000 PSI MINIMUM <br />AS DETERMINED BY TESTING OR PREVIOUSLY DOCUMENTED DATA FOR THE <br />MIX DESIGN USED UNDER SIMILAR CONDITIONS, AND MUST BE ALLOWED TO <br />CURE FOR A MINIMUM OF 3 DAYS. <br />15. FOR INTERIOR SLABS-ON-GRADE AND ALL OTHER SLABS RECEIVING ADHERED <br />FLOORING FINISHES (I.E., GLUED, ETC.), THE MAXIMUM W/C RATIO SHALL NOT <br />EXCEED 0.45. CURING COMPOUNDS USED ON CONCRETE THAT IS TO RECIEVE <br />FINISHES SHALL BE COMPATIBLE WITH TILE AND ADHESIVES OR GROUTS IN <br />ACCORDANCE WITH MANUFACTURER'S DATA AND BE APPROVED BEFORE USE. <br />16. MAINTAIN CONCRETE ABOVE 50 DEGREES FAHRENHEIT AND IN A MOIST <br />CONDITION FOR A MINIMUM OF 7 DAYS AFTER PLACEMENT UNLESS OTHERWISE <br />ACCEPTED BY SEOR. <br />17. SEE ARCHITECTURAL DRAWINGS FOR WALL OPENINGS, WALL OFFSETS, <br />CHAMFERS, KERFS, DRIPS AND FOR EXTENT OF DEPRESSIONS, RAMPS, ETC. <br />PROVIDE SLEEVES FOR ALL PIPES THROUGH CONCRETE WALLS AND FOOTINGS <br />WHERE SHOWN ON THESE DRAWINGS. CORING IS NOT PERMITTED WITHOUT <br />PRIOR APPROVAL BY THE SEOR AND DSA. <br />18. EXPOSED CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC. SHALL BE <br />FORMED WITH 3/4" CHAMFER, UNO. <br />STRUCTURAL CONCRETE NOTES: <br />LOCATION <br />CONC <br />TYPE <br />MAX <br />AGGR. <br />SIZE <br />MAX <br />W/C <br />RATIO <br />MAX <br />SLUMP <br />FOUNDATIONS 3000 PSI NWC 1 1/2" 0.45 4" <br />SLAB ON GRADE 3000 PSI NWC 1" 0.45 4" <br />ALL OTHER STRUCTURAL <br />CONCRETE NOT NOTED <br />ABOVE <br />3000 PSI NWC 1" 0.50 6" <br />MIN 28-DAY <br />COMP <br />STRENGTH <br />Kzt = 1 <br />Rho = 1.0 <br />INTERNAL PRESSURE COEFF. = +/- 0.18 <br />DESIGN PROCEDURE: <br />ELFP <br />STATEMENT OF SPECIAL INSPECTIONS: <br />1. THE OWNER SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE <br />INSPECTIONS DURING CONSTRUCTION. THE SPECIAL INSPECTOR SHALL BE A <br />QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION <br />OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE PARTICULAR TYPE OF <br />CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. <br />2. SPECIAL INSPECTIONS ARE NOT REQUIRED WHERE THE WORK IS DONE ON THE <br />PREMISES OF A LA APPROVED FABRICATOR REGISTERED AND APPROVED TO <br />PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. APPROVED FABRICATORS <br />MUST SUBMIT A CERTIFICATE OF COMPLIANCE FOR OFFSITE FABRICATIONS SUCH AS <br />STRUCTURAL STEEL, PRECAST CONCRETE, GLUED LAMINATED TIMBER, ETC. <br />3. ALL INSPECTIONS SHALL BE PERFORMED BY INDEPENDENT SPECIAL INSPECTORS. <br />JOB SITE VISITS BY THE STRUCTURAL ENGINEER OR BUILDING OFFICIAL DO NOT <br />CONSTITUTE AND ARE NOT A SUBSTITUTE FOR INSPECTIONS BY A SPECIAL <br />INSPECTOR. <br />4. ALL INSPECTION REPORTS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL AND <br />SEOR. THE FINAL REPORTS BY THE SPECIAL INSPECTOR(S) MUST CERTIFY THAT THE <br />ENTIRE STRUCTURAL SYSTEM COMPLIES WITH THE APPROVED PLANS AND <br />SPECIFICATIONS. <br />5. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO SEE THAT THESE INSPECTIONS <br />ARE PERFORMED. <br />6. WORK REQUIRING SPECIAL INSPECTION SHALL BE INSPECTED BY THE SPECIAL <br />INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK IS PERFORMED AND AT <br />THE COMPLETION OF WORK. CONTINUOUS INSPECTION CONSISTS OF FULL-TIME <br />INSPECTION; PERIODIC INSPECTION CONSISTS OF PART-TIME OR INTERMITTENT <br />INSPECTION. <br />7. THE FOLLOWING SPECIAL INSPECTIONS ARE IN ADDITION TO INSPECTIONS BY THE <br />BUILDING OFFICIAL. THIS LIST IS NOT INTENDED TO BE ALL INCLUSIVE. <br />TABLE 1705.6 <br />REQUIRED VERIFICATION AND INSPECTION OF SOILS <br />VERIFICATION AND INSPECTION TASK <br />CONTINUOUS <br />DURING TASK <br />LISTED <br />PERIODICALLY <br />DURING TASK <br />LISTED <br />1.VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS <br />ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING <br />CAPACITY. <br />- X <br />2.VERIFY EXCAVATIONS ARE EXTENDED TO PROPER <br />DEPTH AND HAVE REACHED PROPER MATERIAL. - X <br />3.PERFORM CLASSIFICATION AND TESTING OF <br />COMPACTED FILL MATERIALS.- X <br />4. <br />VERIFY USE OF PROPER MATERIALS, DENSITIES AND <br />LIFT THICKNESSES DURING PLACEMENT AND <br />COMPACTION OF COMPACTED FILL. <br />X - <br />5. <br />PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE <br />SUBGRADE AND VERIFY THAT SITE HAS BEE N <br />PREPARED PROPERLY. <br />- X <br />TABLE 1705.3 <br />REQUIRED VERIFICATION AND INSPECTION OF CONCRETE <br />CONSTRUCTION <br />VERIFICATION AND INSPECTION CONT. PERIODIC REF. <br />STANDARD <br />CBC <br />REF. <br />1.INSPECTION OF REINFORCING STEEL, <br />INCLUDING PRESTRESSING TENDONS, <br />AND PLACEMENT. <br />-AIC 318: 3.5, <br />7.1-7.7 1913.4 <br />2. INSPECTION OF REINFORCING STEEL <br />WELDING IN ACCORDANCE WITH TABLE <br />1704A.3, ITEM 5B. <br />- -AWS D1.4; ACI <br />318: 3.5.2 - <br />3. INSPECTION OF BOLTS TO BE <br />INSTALLED IN CONCRETE PRIOR TO <br />AND DURING PLACEMENT OF <br />CONCRETE WHERE ALLOWABLE LOADS <br />HAVE BEEN INCREASED OR WHERE <br />STRENGTH DESIGN IS USED. <br />X -ACI 318: 8.1.3, <br />21.2.8 <br />1911.5, <br />1912.1 <br />4.INSPECTION OF ANCHORS INSTALLED <br />IN HARDENED CONCRETE.-ACI 318: 3.8.6, <br />8.1.3, 21.2.8 1912.1 <br />5.VERIFYING USE OF REQUIRED DESIGN <br />MIX.- X ACI 318: CH 4, <br />5.2-5.4 <br />1904.2.2, <br />1913.2, <br />1913.3 <br />6.AT THE TIME FRESH CONCRETE IS <br />SAMPLED TO FABRICATE SPECIMENS <br />FOR STRENGTH TESTS, PERFORM <br />SLUMP AND AIR CONTENT TESTS, AND <br />DETERMINE THE TEMPERATURE OF <br />THE CONCRETE. <br />X - <br />ASTM C172 <br />ASTM C31; ACI <br />318: 5.6, 5.8 <br />1913.10 <br />7.INSPECTION OF CONCRETE AND <br />SHOTCRETE PLACEMENT FOR PROPER <br />APPLICATION TECHNIQUES. <br />X -ACI 318: 5.9, <br />5.10 <br />1913.6, <br />1913.7, <br />1913.8 <br />8. INSPECTION FOR MAINTENANCE OF <br />SPECIFIED CURING TEMPERATURE <br />AND TECHNIQUES. <br />-ACI 318: <br />5.11-5.13 1913.9 <br />9.INSPECTION OF PRESTRESSED <br />CONCRETE:X - <br />A <br />. <br />APPLICATION OF PRESTRESSING <br />FORCES.ACI 318: 18.20 - <br />B <br />. <br />GROUTING OF BONDED <br />PRESTRESSING TENDONS IN THE <br />SEISMIC-FORECE-RESISTING <br />SYSTEM. <br />ACI 318: 18.18.4 - <br />10.ERECTION OF PRECAST CONCRETE <br />MEMBERS.-ACI 318: CH 16 - <br />11.VERIFICATION OF IN-SITU CONCRETE <br />STRENGTH, PRIOR TO STRESSING OF <br />TENDONS IN POSTTENSIONED <br />CONCRETE AND PRIOR TO REMOVAL <br />OF SHORES AND FORMS FROM BEAMS <br />AND STRUCTURAL SLABS. <br />-ACI 318: 6.2 - <br />12.INSPECT FORMWORK FOR SHAPE, <br />LOCATION AND DIMENSIONS OF THE <br />CONCRETE MEMBER BEING FORMED. <br />-ACI 318: 6.1.1 - <br />FOR SI: 1 INCH = 25.4 MM <br />A. WHERE APPLICABLE, SEE ALSO SECTION 1705.11, SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE. <br />B. SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTIONS SHALL BE INCLUDED IN THE RESEARCH <br />REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH ACI 355.2 OR <br />SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO COMMENCEMENT OF THE WORK. <br />C. INSTALLATION OFF ALL ADHESIVE ANCHORS IN THE HORIZONTAL AND UPWARDS INCLINED <br />POSITIONS SHALL BE PERFORMED BY AN ACI/CRSI CERTIFIED ANCHOR INSTALLER. <br />1. ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. <br />2. DOUGLAS FIR (DF) SHALL BE GRADED BY THE WESTERN WOOD PRODUCTS <br />ASSOCIATION GRADING RULES, AND ASTM D245. <br />3. REDWOOD SHALL BE GRADED BY THE CALIFORNIA REDWOOD ASSOCIATION, <br />REDWOOD INSPECTION SERVICE. <br />4. SILL PLATES SHALL BE PRESSURE-TREATED (PT) DOUGLAS FIR #1. REDWOOD <br />IS PERMITTED WITH SEOR APPROVAL. <br />5. TOP PLATES, SILL PLATES, STUDS SHALL BE....................................DF #1 <br />JOISTS, RAFTERS, PURLINS, BEAMS & POSTS SHALL BE ................DF #1 (UNO) <br />LOAD BEARING STUDS SHALL BE.........................................................DF #1 <br />6. MOISTURE CONTENT OF SAWN LUMBER SHALL NOT EXCEED 18% WHEN <br />FRAMING STARTS OR SHEATHING IS APPLIED. ANY NONCOMPLIANT WORK <br />SHALL BE REJECTED AND REFRAMED WITH ACCEPTABLE LUMBER. <br />7. TIMBERS 4" NOMINAL IN THE LEAST DIMENSION SHALL NOT CONTAIN BOXED <br />HEART. <br />8. SILL PLATES SHALL BE PRESSURE-TREATED AND SHALL BE BOLTED TO <br />CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS AT 32" OC MAX, UNO WITH A <br />BOLT BETWEEN 4" TO 12" FROM THE END OF EACH PIECE OF SILL (2 BOLTS MIN <br />EACH PIECE). PIECE OF SILL SHALL BE CONSIDERED ENDED WHERE PLATE IS <br />CUT OUT OVER ONE-THIRD OF CROSS-SECTION. <br />9. ANCHOR BOLTS FOR NON-STRUCTURAL WALLS SUPPORTED ON SLABS SHALL <br />HAVE 3 1/2" EMBEDMENT (UNO) MEASURED FROM TOP OF SLAB. <br />10. ANCHOR BOLTS FOR STRUCTURAL WALLS SHALL HAVE 12" EMBEDMENT (UNO) <br />MEASURED FROM TOP OF SLAB. <br />11. STUD BEARING WALLS AND PARTITIONS SHALL HAVE DOUBLE TOP PLATES <br />LAPPED AT WALL AND PARTITION INTERSECTIONS. JOINTS IN UPPER AND <br />LOWER MEMBERS OF DOUBLE TOP PLATES SHALL BE STAGGERED AT LEAST <br />4'-0". <br />12. HOLES IN WOOD AND STEEL MEMBERS FOR BOLTS SHALL BE THE NOMINAL <br />BOLT DIAMETER PLUS 1/16". <br />13. ALL BOLTS IN WOOD SHALL BE ASTM A307 STANDARD BOLTS, UNO. BOLTS AND <br />SCREWS SHALL BE TIGHTENED AT TIME OF ERECTION AND RETIGHTENED <br />BEFORE CLOSING IN OR AT THE COMPLETION OF THE JOB. <br />14. HOLES IN WOOD FOR LAG SCREW SHANK SHALL BE BORED TO THE SAME <br />DIAMETER AND DEPTH AS THE SHANK, AND FOR THE THREADED PORTION <br />BORED WITH A BIT NOT LARGER THAN 40% TO 70% OF THE SHANK DIAMETER. <br />15. LAG SCREWS AND SCREWS SHALL BE SCREWED AND NOT DRIVEN INTO PLACE. <br />BOLT HOLES SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM 1/16" LARGER THAN <br />THE BOLT DIAMETER. HOLES SHALL BE ACCURATELY ALIGNED IN MAIN <br />MEMBERS AND SIDE PLATES. BOLTS SHALL NOT BE FORCIBLY DRIVEN. <br />16. METAL FRAMING CONNECTORS SHALL BE MANUFACTURED BY SIMPSON <br />STRONG TIE COMPANY (CURRENT CATALOG), OR "USP" WITH EQUIVALENT ICC <br />PUBLISHED VALUES AND SHALL BE INSTALLED PER SPECIFICATIONS, NO <br />EXCEPTIONS. <br />17. INSTALL WINDOWS AND DOORS IN STUD WALLS AFTER DEAD LOADS ARE <br />APPLIED, AND PROVIDE A 1/2" SHIM SPACE AT THE HEAD CONDITION. <br />18. STEEL WASHERS SHALL BE PROVIDED UNDER HEADS AND NUTS OF ALL BOLTS <br />AND LAG SCREWS WHICH BEAR ON WOOD. STANDARD CUT WASHERS MAY BE <br />USED IN ALL CASES EXCEPT SILL PLATES AND WOOD LEDGERS AGAINST <br />CONCRETE OR MASONRY. NOTE, WASHERS UNDER CARRIAGE BOLT HEADS <br />SHALL BE LARGE ENOUGH TO ALLOW FOR SQUARE SHOULDERS. <br />19. ONLY LOAD BEARING AND/OR SHEAR WALLS ARE SHOWN. SEE <br />ARCHITECTURAL DRAWINGS FOR ALL OTHER PARTITIONS. <br />20. ELEVATIONS SHOWN ON PLANS ARE FROM FINISHED FIRST FLOOR, DATUM <br />ELEVATION = 0'-0". <br />21. ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS ARE 2x6 STUDS @ 16"OC <br />TYPICAL, UNO. <br />22. ALL EXTERIOR STUD WALLS SHALL BE COMPLETELY SHEATHED WITH 15/32" <br />APA RATED SHEATHING, EXPOSURE-1 (32/16). <br />23. INTERIOR STRUCTURAL SHEATHED WALLS ARE SHOWN ON PLANS AND SHALL <br />HAVE 15/32" APA RATED SHEATHING EXPOSURE-1, (32/16),TYPICAL UNO. <br />24. ALL STRUCTURAL WALL SHEATHING IS SPLICED ON 2" NOMINAL BLOCKING AT <br />HORIZONTAL JOINTS, UNO. <br />25. STRUCTURAL FLOOR AND ROOF SHEATHING SHALL BE AS SPECIFIED BELOW. <br />NOTE: 1/8" GAP SHALL BE PROVIDED BETWEEN ADJACENT PANELS. PANELS <br />WITH GRADE STAMP INDICATION "SIZED FOR SPACING" MAY BE USED TO <br />FACILITATE THIS REQUIREMENT. SEE PLANS FOR REQUIRED BOUNDARY AND <br />EDGE NAILING NOT LISTED BELOW. FLOOR SHEATHING SHALL BE GLUED AND <br />NAILED PER PLAN. <br />( * - SHEATHING @ EXTERIOR DECKS SHALL BE EXTERIOR RATED PLYWOOD.) <br />BN=BOUNDARY NAILING <br />EN=EDGE NAILING <br />FN=FIELD NAILING <br />26. SEE PLANS FOR LOCATION OF NOMINAL 2X FLAT BLOCKING AT ROOF <br />SHEATHING PANEL JOINTS. SEE THIS SHEET FOR PLY CLIP REQUIREMENTS AT <br />UNBLOCKED ROOF PANEL JOINTS. T&G SHEATHING IS NOT REQUIRED WHERE <br />JOINTS ARE BLOCKED. <br />27. (S) INDICATES METAL FRAMING CONNECTORS MANUFACTURED BY SIMPSON <br />STRONG TIE COMPANY (CURRENT CATALOG) OR "USP" WITH EQUIVALENT ICC <br />PUBLISHED VALUES AND SHALL BE INSTALLED PER SPECIFICATIONS, NO <br />EXCEPTIONS. <br />ROUGH CARPENTRY/ WOOD NOTES: <br />1705.11.2 STRUCTURAL WOOD. <br />CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING FIELD GLUING OPERATION <br />OF ELEMENTS OF THE SEISMIC FORCE-RESISTING SYSTEM. PERIODIC SPECIAL <br />INSPECTION IS REQUIRED FOR NAILING, BOLTING, ANCHORING AND OTHER <br />FASTENING OF COMPONENTS WITHIN THE SEISMIC FORCE-RESISTING SYSTEM, <br />INCLUDING WOOD SHEAR WALLS, WOOD DIAPHRAGMS, DRAG STRUTS, BRACES, <br />SHEAR PANELS AND HOLD0DOWNS. <br />WOOD LATERAL LOAD RESISTING <br />SYSTEM SPECIAL INSPECTION: <br />EXCEPTION: <br />SPECIAL INSPECTION IS NOT REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS <br />AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING AND OTHER <br />FASTENING TO OTHER COMPONENTS OF THE SEISMIC FORCE0RESISTING SYSTEM, <br />WHERE THE FASTENER SPACING IF THE SHEATHING IS MORE THAN 4INCHES <br />(102MM) ON CENTER (O/C) <br />FOUNDATION NOTES (NO SOILS REPORT): <br />(UNLESS OTHERWISE NOTED ON PLANS) <br />NAIL SPACING TO BE NOT LESS THAN REQUIRED PENETRATION. EDGE AND END <br />DISTANCES SHALL BE NOT LESS THAN HALF THIS SPACING. ALL SPACING AND EDGE <br />AND END DISTANCES SHALL BE SUCH AS TO AVOID SPLITTING OF THE WOOD. <br />HOLES FOR NAILS, WHERE NECESSARY TO PREVENT SPLITTING, SHALL BE BORED <br />OF A DIAMETER SMALLER THAN THAT OF THE NAILS. COMMON NAILS SHALL BE <br />USED FOR NAILING AT TYPICAL CONNECTIONS NOTED BELOW (U.N.O.). FOR ALL <br />CONNECTIONS OTHERWISE NOTED OR DETAILED ON PLANS, COMMON NAILS SHALL <br />BE USED (SEE SCHEDULE BELOW). <br />NAILING SCHEDULE <br />SHORTENED 10d COMMON NAILS MAY BE USED <br />TO FASTEN WOOD STRUCTURAL PANELS UNO. <br />USE THE FOLLOWING MINIMUM LENGTHS: <br />10d x 2 1/4" FOR 15/32" OR THINNER PANELS, <br />10d x 2 3/8" FOR 19/32" PANELS, AND FULL <br />LENGTH FOR 5/8" OR THICKER PANELS. <br />NAIL TYPES <br />SIZE DIAMETER (IN) LENGTH (IN) <br />8d 0.131 2 1/2 <br />10d 0.148 3 <br />12d 0.148 3 1/4 <br />16d 0.162 3 1/2 <br />20d 0.192 4 <br />ROOF <br />1. BLOCKING BETWEEN CEILING JOISTS, RAFTERS OR TRUSSES TO TOP PLATE OR OTHER FRAMING BELOW <br />•EACH END, TOENAIL (4-8D BOX NAILS; OR 3-8D COMMON NAILS; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) <br />2. BLOCKING BETWEEN RAFTERS OR TRUSS NOT AT THE WALL TOP PLATE, TO RAFTER OR TRUSS <br />•EACH END, TOENAIL (2-8D COMMON NAILS; OR 2-3" × 0.131" NAILS) <br />•END NAIL (2-16D COMMON NAILS; OR 3-3" × 0.131" NAILS) <br />3. FLAT BLOCKING TO TRUSS AND WEB FILLER <br />•FACE NAIL (16D COMMON NAILS @ 6" O.C.; OR 3" × 0.131" NAILS @ 6" O.C.) <br />4. CEILING JOISTS TO TOP PLATE <br />•EACH JOIST, TOENAIL (4-8D BOX NAILS; OR 3-8D COMMON NAILS; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) <br />5. RAFTER OR ROOF TRUSS TO TOP PLATE (SEE CBC SECTION 2308.7.5, CBC TABLE 2308.7.5) <br />•2 TOENAILS ON ONE SIDE AND 1 TOENAIL ON OPPOSITE SIDE OF RAFTER OR TRUSSC (3-10 COMMON (3" × 0.148"); <br />OR 3-16D BOX (3 1/2" × 0.135"); OR 4-10D BOX NAILS; OR 4-3" × 0.131 NAILS) <br />6. ROOF RAFTERS TO RIDGE VALLEY OR HIP RAFTERS; OR ROOF RAFTER TO 2-INCH RIDGE BEAM <br />•END NAIL (2-16D COMMON NAILS; OR 3-16D BOX (3 1/2" × 0.135"); OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) <br />•TOENAIL (3-10D COMMON (3 1/2" × 0.148"); OR 4-16D BOX (3 1/2" × 0.135"); OR 4-10D BOX NAILS; OR 4-3" × 0.131" NAILS) <br />WALL <br />1. STUD TO STUD (NOT AT BRACED WALL PANELS) <br />•24" O.C. FACE NAIL (16D COMMON NAILS) <br />•FACE NAIL (10D BOX NAILS; OR 3" × 0.131" NAILS) <br />2. STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS (AT BRACED WALL PANELS) <br />•16" O.C. FACE NAIL (16D COMMON NAILS) <br />•12" O.C. FACE NAIL (16D BOX NAILS; OR 3" × 0.131" NAILS) <br />3. BUILT-UP HEADER (2" TO 2" HEADER) <br />•16" O.C. EACH EDGE, FACE NAIL (16D COMMON NAILS) <br />•12" O.C. EACH EDGE, FACE NAIL (16D BOX NAILS) <br />4. CONTINUOUS HEADER TO STUD <br />•TOENAIL (4-8D COMMON NAILS; OR 4-10D BOX NAILS; OR 5-8D BOX NAILS) <br />5. TOP PLATE TO TOP PLATE <br />•16" O.C. FACE NAIL (16D COMMON NAILS) <br />•12" O.C. FACE NAIL (10D BOX NAILS; OR 3" × 0.131" NAILS) <br />6. TOP PLATE TO TOP PLATE, AT END JOINTS <br />•EACH SIDE OF END JOINT, FACE NAIL WITH MINIMUM 24" LAP SPLICE LENGTH EACH SIDE OF END JOINT (8-16D COMMON <br />NAILS; OR 12-16D BOX NAILS; OR 12-10D BOX NAILS; OR 12-3" × 0.131" NAILS) <br />7. BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING (NOT AT BRACED WALL PANELS) <br />•16" O.C. FACE NAIL (16D COMMON NAILS ) <br />•16" O.C. FACE NAIL (16D BOX NAILS; OR 3" × 0.131" NAILS) <br />8. BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST OR BLOCKING AT BRACED WALL PANELS <br />•16" O.C. FACE NAIL (2-16D COMMON NAILS; OR 3-16D BOX NAILS; OR 4-3" × 0.131" NAILS) <br />9. STUD TO TOP OR BOTTOM PLATE <br />•TOENAIL( 3-16D BOX; OR 4-8D COMMON NAILS; OR 4-10D BOX NAILS; OR 4-3" × 0.131" NAILS; OR 4-8D BOX NAILS) <br />•END NAIL (2-16D COMMON NAILS; OR 3-16D BOX; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) <br />10. TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS <br />•FACE NAIL (2-16D COMMON NAILS; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) <br />FLOOR <br />1. JOIST TO SILL, TOP PLATE, OR GIRDER <br />•TOENAIL (4-8D BOX; OR 3-8D COMMON NAILS; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) <br />2. RIM JOIST, BAND JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER FRAMING BELOW <br />•4" O.C., TOENAIL (8D BOX NAILS) <br />•6" O.C., TOENAIL (8D COMMON NAILS; OR 10D BOX NAILS; OR 3" × 0.131" NAILS) <br />3. 26. BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYERS <br />•32" O.C., FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES (20D COMMON NAILS) <br />•24" O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES (10D BOX NAILS; OR 3" × 0.131" NAILS) <br />•AT ENDS AND AT EACH SPLICE, FACE NAIL (2-20D COMMON NAILS; OR 3-10D BOX NAILS; OR 3-3" × 0.131" NAILS) <br />4. LEDGER STRIP SUPPORTING JOISTS OR RAFTERS <br />•EACH JOIST OR RAFTER, FACE NAIL (3-16D COMMON NAILS; OR 4-16D BOX NAILS; OR 4-10D BOX NAILS; OR 4-3" × 0.131" NAILS) <br />5. JOIST TO BAND JOIST OR RIM JOIST <br />•END NAIL (3-16D COMMON NAILS; OR 4-10D BOX NAILS; OR 4-3" × 0.131" NAILS) <br />6. BRIDGING OR BLOCKING TO JOIST, RAFTER OR TRUSS <br />•EACH END, TOENAIL (2-8D COMMON NAILS; OR 2-10D BOX NAILS; OR 2-3" × 0.131" NAILS) <br />1. NO SOILS REPORT AVAILABLE; THEREFORE, MINIMUM VALUES USED PER 2022 CBC. <br />2. ALLOWABLE VERTICAL BEARING PRESSURE = 1500 PSF <br />ALLOWABLE LATERAL BEARING PRESSURE = 100 PSF PER FT OF DEPTH <br />3. THE CONTRACTOR SHALL CONFORM TO ALL RECOMMENDATIONS AND CONDITIONS <br />INDICATED IN THE 2022 CBC. A GEOTECHNICAL ENGINEER SHALL OBSERVE ALL <br />FOOTING EXCAVATIONS PRIOR TO PLACING CONCRETE. <br />4. WHERE THE BUILDING OFFICIAL HAS REASON TO DOUBT THE CLASSIFICATION, <br />STRENGTH OR COMPRESSIBILITY OF THE SOIL OR WHERE A LOAD-BEARING VALUE <br />SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BULIDNG OFFICIAL <br />SHALL BE PERMITTED TO REQUIRE THAT A GEOTECHNICAL INVESTIGATION BE <br />CONDUCTED. <br />5. PRESUMPTIVE LOAD-BEARING VALUES SHALL APPLY TO MATERIALS WITH SIMILAR <br />PHYSICAL CHARACTERISTICS AND DISPOSITIONS.MUD, ORGANIC SILT, ORGANIC <br />CLAYS, PEAT OR UNPREPARED FILL SHALL NOT BE ASSUMED TO HAVE A <br />PRESUMPTIVE LOAD-BEARING CAPACITY UNLESS DATA TO SUBSTANIATE THE USE <br />OF SUCH A VALUE ARE SUBMITTED. <br />5.1. EXCEPTION: A PRESUMPTIVE LOAD-BEARING CAPACITY SHALL BE PERMITTED <br />TO BE USED WHERE THE BUILDING OFFICIAL DEEMS THE LOAD-BEARING <br />CAPACITY OF MUD, ORGANIC SILT OR UNPREPARED FILL IS ADEQUATE FOR THE <br />SUPPORT OF LIGHTWEIGHT OR TEMPORARY STRUCTURES. <br />6. THE BOTTOM OF FOUNDATION SHALL BE CLEARED AND COMPACTED TO 90 <br />PERCENT OF THE MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT <br />DETERMINED IN ACCORDANCE WITH ASTM D1557. <br />7. SPREAD FOOTINGS ARE CENTERED UNDER WALLS AND COLUMNS, UNO. <br />8. FOOTING ELEVATIONS ARE NOTED ON THE PLANS AND DETAILS AND SHALL BE USED <br />FOR BIDDING. IN ANY CASE, FOOTINGS SHALL BEAR ON FIRM UNDISTURBED SOIL <br />OR ENGINEERED FILL, IN ACCORDANCE WITH THE CURRENT BUILDING CODE AND <br />DETAILS SHOWN. <br />9. CONTRACTOR SHALL PROTECT ALL UTILITY LINES, ETC. ENCOUNTERED DURING <br />EXCAVATION AND BACKFILLING. <br />10. ALL EXCAVATION SHALL COMPLY WITH APPLICABLE OSHA REQUIREMENTS. <br />11. PRIOR TO REINFORCEMENT FOR FOUNDATIONS BEING PLACED, THE CONTRACTOR <br />SHALL SUBMIT A REPORT INDICATES THE ITEMS 5, 6, 7, 8, 9 AND 10 ARE VERIFIED. <br />THE REPORT SHALL ALSO STATE THAT: <br />11.1. THE BUILDING PAD WAS PREPARED IN ACCORDANCE WITH THE APPROVED <br />CONSTRUCTION DOCUMENTS. <br />11.2. THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED AND COMPACTED. <br />11.3. THE FOUNDATION EXCAVATIONS COMPLY WITH THE INTENT OF THE APPROVED <br />CONSTRUCTION DOCUMENTS. <br />PROJECT NUMBER: <br />A <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br />: <br />CHECKED: <br />DRAWN: <br />ISSUE/REVISION: <br />7/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />1 <br />9 <br /> <br />4 <br />: <br />0 <br />6 <br />: <br />5 <br />5 <br /> <br />P <br />M <br /> <br />C <br />: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />y <br />m <br />i <br />n <br />\ <br />D <br />o <br />c <br />u <br />m <br />e <br />n <br />t <br />s <br />\ <br />S <br />- <br />T <br />h <br />o <br />m <br />p <br />so <br />n <br />_ <br />R <br />1 <br />7 <br />_ <br />Y <br />m <br />i <br />n <br />. <br />r <br />v <br />t <br />LT201801 <br />S- <br />2 <br />. <br />1 <br /> <br />2 <br />/ <br />2 <br />7 <br />/ <br />2 <br />0 <br />1 <br />9 <br />Th <br />o <br />m <br />p <br />s <br />o <br />n <br /> <br />R <br />e <br />s <br />i <br />d <br />e <br />n <br />c <br />e <br />CITY SUBMITTAL <br />23 <br />4 <br />4 <br /> <br />N <br />. <br /> <br />F <br />a <br />i <br />r <br />m <br />o <br />n <br />t <br />Av <br />e <br />n <br />u <br />e <br />, <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />E N G I N E E R S I N C <br />2401 E Katella Ave. #430 <br />Anaheim, CA 92806 <br />Tel. 949.679.0870 <br />Fax. 949.679.9370 <br />Project No.: F482 <br />V C A <br />C I V I LQuality <br />Service <br />Commitment <br />S T R U C T U R A L DBEMBE SBE <br />02-S001 <br />05/06/2026 Revision 23 <br />3 <br />3