Laserfiche WebLink
Framing Results: <br />Below is a summary table of the results of the analysis and a description of upgrades if required. <br />Anchorage: <br />Below is a summary of the type of connection(s) that is proposed to be used and the allowable spacings. <br />Attachment  <br />Name Pattern:  <br />Where racking method is railless, attachments are located where panels meet. Otherwise, the attachments are connected directly to the rails. <br />Unless noted otherwise, all allowable cantilevers are limited to the maximum attachment spacing divided by 3. (1/3*spacing) <br />Limitations: <br />Please contact me with any further questions or concerns regarding this project. <br />Sincerely, <br />John Calvert, P.E. <br />Domus Structural Engineering, LLC <br />The scope of this report is strictly limited to an evaluation of the fastener attachment, underlying framing and supporting  <br />structure only. All panels, racking and hardware shall be installed per manufacturer specifications and within specified design  <br />limitations. All waterproofing shall be provided by the manufacturer. Domus Structural Engineering, LLC assumes no  <br />responsibility for misuse or improper installation of the solar PV panels or racking. <br />NoneRoof 1 <br />(2) 5/16" dia. lag screws with 2.5 inch min.  <br />embedment depth into framing.2 ‐ 5/16" dia. lag 2 Rails <br />Results Upgrade (if required)Array Name(s) <br />Adequate to support the imposed loading ‐ No  <br />structural upgrades required <br />Racking Method <br />Staggered <br />Maximum Spacing  <br />(Landscape/Portrait) <br />72 in. L / 72 in. P <br />Fastener  <br />P.O. Box 560, Broomfield, CO 80038 | projects@domusstruc.com | Page 2 of 8