My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2306 W Manly Ave - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Manly Ave
>
2306 W Manly Ave
>
2306 W Manly Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2026 5:00:12 AM
Creation date
6/10/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20188696
Full Address
2306 W Manly Ave
Street Number
2306
Street Direction
W
Street Name
Manly
Street Suffix
Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PAGE <br />REV: A 4/27/2026 <br />JAMES POBOG <br />2306 W MANLY AVE, SANTA <br />ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-306POBO2 PR-3005088446 <br />SHEET <br />DESIGNER: <br />SREERAJ P R <br />CUSTOMER RESIDENCE: <br />TEL. (714) 788-0787 <br />APN: 412-253-53 <br />(415) 580-6920 ex3 <br />PV-5.0 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />SIGNAGE <br />NOTES AND SPECIFICATIONS: <br />·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2025 ARTICLE <br />110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR <br />IF REQUESTED BY THE LOCAL AHJ. <br />·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE <br />WORDS, COLORS AND SYMBOLS. <br />·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING <br />METHOD AND SHALL NOT BE HAND WRITTEN. <br />·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT <br />INVOLVED. <br />·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY <br />SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. <br />·DO NOT COVER EXISTING MANUFACTURER LABELS. <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER AND ESS <br />OCPD (IF APPLICABLE). <br />PER CODE(S): CEC 2025: 705.12(B)(2) <br />SOLAR <br />ELECTRIC PV <br />PANELS <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS <br />ARE CONNECTED. <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN PV <br />SYSTEM AND REDUCE SHOCK <br />HAZARD IN THE ARRAY. <br />4" <br />3" <br />PER CODE(S): CEC 2025: 690.12(D) <br />ELECTRICAL SHOCK HAZARD <br />WARNING! <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), <br />AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2025: 690.13(B), <br />705.20(7), 706.15(C) <br />LABEL LOCATION: <br />INSTALLED WITHIN 3' OF RAPID SHUT DOWN <br />SWITCH PER CODE(S): CEC 2025: 690.12(D)(2), IFC <br />2021: 1204.5.3 <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES. TOTAL <br />RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN <br />SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF <br />BUSBAR <br />WARNING! <br />LABEL LOCATION: <br />PV LOAD CENTER (IF APPLICABLE) AND <br />ANY PANEL THAT UTILIZES "THE SUM <br />OF BREAKERS RULE". <br />PER CODE(S): CEC 2025: 705.12 (B)(3) <br />INVERTER 1 <br />PHOTOVOLTAIC DC DISCONNECT <br />MAXIMUM SYSTEM VOLTAGE:VDC550 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): CEC 2025: 690.7(D) <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, <br />AT EACH TURN, ABOVE AND BELOW PENETRATIONS, <br />ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): CEC 2025: 690.31(D)(2) <br />WARNING! <br />SOURCES: UTILITY GRID, <br />BATTERY AND PV SOLAR <br />ELECTRIC SYSTEM <br />THREE POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />PER CODE(S): CEC 2025: 705.10, 705.30(C), <br />706.21(A) <br />INVERTER 1 <br />LABEL LOCATION: <br />REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 <br />LOCATION: MAIN PANEL <br />SIZE: 4.25" X 1.25" <br />PCS CONTROLLED CURRENT SETTING: 56 A <br />THE MAXIMUM OUTPUT CURRENT FROM THIS <br />SYSTEM IS CONTROLLED ELECTRONICALLY. <br />REFER TO THE MANUFACTURER'S <br />INSTRUCTIONS FOR MORE INFORMATION. <br />WARNING: THIS SENSOR IS PART <br />OF A POWER CONTROL SYSTEM. <br />DO NOT REMOVE. REPLACE ONLY <br />WITH THE SAME TYPE AND RATING. <br />WARNING: THIS SENSOR IS PART <br />OF A POWER CONTROL SYSTEM. <br />DO NOT REMOVE. REPLACE ONLY <br />WITH THE SAME TYPE AND RATING. <br />REQUIREMENT: UL 1741, SECTION 206.3 <br />LOCATION: AROUND THE CT WIRE BY CLAMP <br />SIZE 4.25" X 0.75" <br />NOMINAL ESS VOLTAGE VAC <br />LABEL LOCATION: <br />ENERGY STORAGE SYSTEM <br />PER CODE(S): CEC 2025: 706.15(C) <br />120/240 <br />ENERGY STORAGE SYSTEM DISCONNECT <br />ENERGY STORAGE SYSTEM <br />CAUTION! <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2025: 706.15(C)
The URL can be used to link to this page
Your browser does not support the video tag.