Laserfiche WebLink
8' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br /> <br />( <br />T <br />Y <br />P <br />. <br />) <br />13'-11"15'-2"13'-10"13'-10"18'-2"17'-6"20'-0"20'-0"19'-6"19'-7" <br />ROOF <br />ACCESS <br />HATCH <br />173'-0" <br />13 <br />1 <br />' <br />- <br />4 <br />" <br />4'-0"4'-0" <br />4' <br />- <br />0 <br />" <br />4' <br />- <br />0 <br />" <br />3'-0" <br />1' <br />- <br />0 <br />" <br />3' <br />- <br />6 <br />" <br />2'-6" <br />3'-0" <br />SHEET NUMBER <br />PV-3.0 <br />NEW GRID - TIED SYSTEM 103.84 kW <br />DATE: 5/25/2026 <br />DRAWN BY: <br />MCGUFF <br />APN: 415-021-15 <br />Utility: SDGE <br />AHJ: CITY OF SANTA ANA <br />3080 S. HARBOR BLVD. <br />SANTA ANA, CA 92704 <br />CARLSBAD SOLAR CORPORATION <br />3525 HIGHLAND DR. <br />CARLSBAD, CA 92008 <br />PHONE: 760-826-9226 <br />CSLB #1023872 <br />TOP JUNCTION BOX <br />SOLAR MODULES <br />PVC PIPE VENT <br />48" FIRE SETBACKS <br />INTERIOR EQUIPMENT <br />SHOWN AS DASHED <br />MAIN SWITCH BOARD <br />LEGEND : <br />FLUSH ATTIC VENT <br />CHIMNEY <br />UTILITY METERUM <br />MSB <br />INV <br />- - - - - - - - - - 3/4" EMT CONDUIT RUN <br />JB <br />(238)SNAPNRACK ULTRA RAIL TILT-MOUNT KIT <br />1. Attach clamps at 25% from edge and <br />50% from center of modules. <br />2. Junction box mounted to the rail. <br />MODULE <br />(176)MISSION SOLAR <br />MSI10-590HN4G 590W <br />MODULES <br /> Module Dimensions 89.60"x 44.6"x1.2" <br />Module Weight 70.99 LBS (32.2 KG) <br />MODULES AREA SQ.FT.27.75 <br />Unit Weight of Array (PSF)2.56 <br />AC DISCONNECTAC <br />ARRAY AREA & ROOF AREA CALC'S <br />Total Array <br />Area (Sq.Ft.) <br />Area of Roof <br />(Plan View) <br />Total Roof Area <br />Covered by Array % <br />4892.80 22972.5 21.30 <br />ROOF AREA (ARRAY <33% OF ROOF AREA) <br />ALTERNATELY, BOND THE METAL PARTS OF PV EQUIPMENT <br />TO GROUNDED METAL SUPPORTS PER CEC 690.43(B). <br />ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM) <br />LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) <br />INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR <br />ATTACHMENTS <br />48 <br />" <br />ROOF PLAN <br />1 ROOF PLAN: <br />SCALE: 1" = 8'-0" <br />S.R.ARRAY <br />TILT AZIMUTH PV AREA <br />(SQ. FT) <br />NO. OF <br />MODULES <br />ROOF AREA <br />(SQ. FT) <br />ROOF AREA COVERED <br />BY ARRAY (%)ROOF TYPE ROOF ATTACHMENT ROOF HEIGHT FRAME PURLINS <br />AR-01 10°180°4884.20 176 22972.5 21.26 TPO SNAPNRACK ULTRA RAIL <br />TILT-MOUNT KIT 2-STORY STEEL 8' BETWEEN PURLINS WITH 2X6 <br />@24" O.C. BETWEEN PURLINS <br />JB <br />Sol-Ark 60K-3P-480V INVERTER <br />ARRAY DISTRIBUTION WEIGHT CALC'S <br /> NUMBER OF MODULES 176 <br /> ONE MODULE WEIGHT 70.99 LBS <br /> TOTAL MODULE (ARRAY) WEIGHT 12494.24 LBS <br />TOTAL AP Smart RSD-S-PLC WEIGHT 147.84 LBS <br />ULTRA RAIL TILT-MOUNT KIT 23IN 809.20 LBS <br />ULTRA RAIL TILT-MOUNT KIT 14IN 476 LBS <br />DOMESTIC UR-45 RAIL 172" - MILL 532.80 LBS <br />UR-40 & UR-45 SPLICE, SILVER (USA)42.64 LBS <br />ULTRA RAIL MID CLAMP, BLACK (USA)48.60 LBS <br />ULTRA RAIL END CLAMP, BLACK (USA)5.12 LBS <br />DOMESTIC OMNILUG 1.36 LBS <br />UR-45 END CAP 6.40 LBS <br /> TOTAL SYSTEM WEIGHT 14564.20 LBS <br /> WEIGHT OF EACH ATTACHMENT POINT 18.0 LBS <br /> TOTAL ARRAY AREA 4892.80 Sq.Ft. <br /> DISTRIBUTED LOAD (PSF)0.63 LBS <br /> TOTAL ROOF AREA 22972.5 Sq.Ft. <br />UM <br />MS <br />B <br />IN <br />V <br />IN <br />V <br />BAT <br />JB <br />CB <br />BAT Sol-Ark L3-HVR-60KWH BATTERY <br />LC 200A LOAD CENTER <br />4' <br />- <br />0 <br />" <br />4' <br />- <br />0 <br />" <br />4'-0" <br />ADDITIONAL RACKING IS FOR FUTURE SOLAR. <br />4'-0" <br />BAT <br />17'-0" <br />DC <br />BATTERY + INVERTER WEATHER-PROTECTED <br />ENCLOSURE (8 FT TALL) (ENCLOSURE BY <br />OTHERS -- NOT IN PERMIT SCOPE.) <br />AP Smart RSD-S-PLC <br />7' <br />- <br />0 <br />" <br />SU <br />B <br />PLC <br />PROTECTED LOADS <br />PANEL <br />JB AT <br />S <br />PL <br />C <br />HEAVY HEX NUT <br />LOCK WASHER <br />FLAT WASHER <br />Ø5/8" ASTM F1554 <br />GR.36 THREADED ROD <br />EPOXIED INTO <br />FOUNDATION W/ HILTI <br />HIT-HY 200 V3, MIN. <br />3.25" EFFECTIVE <br />EMBEDMENT, <br />INSTALLATION & <br />SPECIAL INSPECTION <br />PER MANUFACTURER <br />SPECS AND ICC <br />ESR-4858 TYP. <br />(E) CONCRETE <br />FOUNDATION <br />(3) ESS ANCHORAGE DETAIL <br />(2) POST-INSTALLED ANCHORS <br />(4) ANCHORS PER STACK <br />CONNECTED DIRECTLY TO <br />(E) CONCRETE FOUNDATION <br />BATTERY WEIGHT <br />950KG & (2,095 LBS)