My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001 E Carnegie Ave - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Carnegie Ave
>
2001 E Carnegie Ave
>
2001 E Carnegie Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2026 5:00:09 AM
Creation date
6/12/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
101126006
Full Address
2001 E Carnegie Ave
Street Number
2001
Street Direction
E
Street Name
Carnegie
Street Suffix
Ave
Text box
ID:
1
Creator:
Import Agent
Created:
6/12/2026 5:00 AM
Modified:
6/11/2026 7:33 AM
Text:
www.hilti.com
ID:
2
Creator:
Import Agent
Created:
6/12/2026 5:00 AM
Modified:
6/11/2026 7:33 AM
ID:
3
Creator:
Import Agent
Created:
6/12/2026 5:00 AM
Modified:
6/11/2026 7:33 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.hilti.com <br />Hilti PROFIS Engineering 3.1.29 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2026 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />1 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Concrete - Mar 16, 2026 (1) <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />4/9/2026 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: Kwik Bolt TZ2 - CS 5/8 (4) hnom3 <br /> Item number: 2210272 KB-TZ2 5/8x5 1/2 <br /> Specification text: HILTI Æ 5/8 IN KWIK BOLT TZ2 - CS WITH <br /> 4.5 IN NOMINAL EMBEDMENT DEPTH PER <br /> ICC-ES ESR-4266 , HAMMER DRILL BIT <br /> INSTALLATION PER MPII <br /> Effective embedment depth: hef,act = 4.000 in., hnom = 4.500 in. <br /> Material: Carbon Steel <br /> Evaluation Service Report: ESR-4266 <br /> Issued I Valid: 12/1/2025 | 12/1/2027 <br /> Proof: Design Method ACI 318-19 / Mech <br /> Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-19 Fig. R.17.7.2.1b) <br /> Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.375 in. <br /> Anchor plateR : lx x ly x t = 17.000 in. x 15.000 in. x 0.375 in.; (Recommended plate thickness: not calculated) <br /> Profile: Rectangular HSS (AISC), HSS8X4X.125; (L x W x T) = 8.000 in. x 4.000 in. x 0.125 in. <br /> Base material: cracked concrete, Custom, fc' = 4,848 psi; h = 6.750 in. <br /> Installation: Hammer drilled hole, Installation condition: Dry <br /> Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present <br /> edge reinforcement: none or < No. 4 bar <br /> Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) <br /> Shear load: yes (17.10.6.3 (c)) <br />R - The anchor calculation is based on a rigid anchor plate assumption. <br />Geometry [in.] & Loading [lb, in.lb]
The URL can be used to link to this page