My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
20174157 - Permit
PBA
>
Building
>
Permits
>
V
>
Van Ness Ave
>
1334 S Van Ness Ave
>
20174157 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2021 8:26:56 AM
Creation date
10/26/2021 8:26:53 AM
Metadata
Fields
Template:
Permit
Permit Number
20174157
Full Address
1334 S Van Ness Ave
Permit ID
278718
Master ID Number
2021-168348
Project Name
Miscellaneous Counter1 Permit
Street Number
001334
Street Direction
S
Street Name
Van Ness
Street Suffix
Ave
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
8/24/2021
Issued Date
8/24/2021
Finalized Date
9/10/2021
Flood Zone
X-0602320276J
Description of Work
Additional panels to existing roof mounted PV system. Total under 10kw. All fees paid on # 101107755.
Nature of Work
Solar - Additional panels
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Ntl il:s l:(ltt S't'nNt)Atr.t> .\ t lUN(; Sys t t,u l:1-1,(..t IUcn t [)tnr;ll.AN4 <br />Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />Contractor Name, <br />Aclclress and Phone <br />VIVINT SOLAR, LLC <br />2500 White Rd <br />lrvine, CA 92614 <br />714-363-2685 <br />System AC SizQ. zuaxw <br />Site Name: Guzrnan <br />Sitg AddfeSS: rrr.r sVarrN,ssAvc <br />Drawn By. <br />SIZE FSCM NO DWG NO REV <br />Checked By.SCALE NTS Date: <br />MODULE MAKE Longi <br />MODULE MODEL LR4.6OHPB-355M <br />MAX POWER-PO|NT CURRENT (tMP)10.27 A <br />MAX PO\ /ER-POINT VOLTAGE (VMP)34.6 v <br />oPEN-CTRCUTT VOLTAGE (Vu.)40.6 v <br />sHoRT-CTRCUtT CURRENT (tsc)11 .25 A <br />MAX SERTES FUSE (OCPD)15 A <br />MAXTMUM PO\ /ER (PMAX)355 w <br />MAX VOLTAGE (TYP 6ooVDC)1000 v <br />VOC TEMP COEFF (mV/oCE or %tocm)-0.27 <br />IF COEFF SUPPLIED, CIRCLE UNITS <br />SIGNS_SEE GUIDE SECT]ON 7 <br />NOTES FOR ALL DRAWINGS: <br />PV MODULE RATINGS @ STC (Guide Section 5) <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODE@ REFERENCES <br />sHowN AS (NEC XXX.XX) <br />INVERTER RATINGS (Guide Section 4) <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D)NOTES FOR INVERTER CIRCUITS (Guide Section I and 9) <br />1.) LO\ /EST EXPECT AMBTENT TEMPERATURE BASED ON ASHRAE MTNTMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION LO\A/EST EXPECTED AMBIENT TEMP g oC <br />2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION HIGHEST CONTINUOUS TEMPERATURE z:r o oQ <br />2.) 2005 ASHRAE FUNDEMENTALS 2% DESTGN TEMPERATURES DO NOT EXCEED <br />47oC tN THE UNTTED STATES (PALM SPR|NGS, CA tS44.1oC).FOR LESSTHAN 9 <br />CURRENT.CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT <br />LEAST O.5,, ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47oC OR LESS (ALL OF UNTTED STATES), <br />a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WTH lsc OF 7 68 AMPS OR LESS \ ftlEN PROTECTED BY A 12-AMP OR SMALLER <br />FUSE <br />b) 10 A\ 13, 90oc CoNDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WTH lsc OF 9 6 AMPS OR LESS \ ftlEN PROTECTED BY A 1S-AMP OR SMALLER <br />FUSE. <br />INVERTER MAKE SOLAR EDGE <br />INVERTER MODEL SE3SOOH-US <br />MAX DC VOLT RATING 48v <br />MAX PO\ /ER @ 40oC 3.8 w <br />NOMINAL AC VOLTAGE 240 v <br />MAX AC CURRENT 16 A <br />MAX OCPD RATING 20A <br />SIGN FOR DC DISCONNECT <br />SIGN FOR INVERTER OCPD AND <br />AC DTSCONNECT (rF USED) <br />PHOTOVOLTAIC POWER SOURCE <br />RATED MPP CURRENT NAA <br />RATED MPP VOLTAGE NAV <br />MAX SYSTEM VOLTAGE NAV <br />MAX CIRCUIT CURRENT NAA <br />WARNING: ELECTRICAL SHOCK <br />HAZARD-LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />AC OUTPUT CURRENT 15.83 A <br />NOMINAL AC VOLTAGE 240 v <br />THIS PANEL FED BY MULTIPLE <br />souRCES (UTrLrrY AND SOLAR) <br />1) IF UTILITY REQUIRES A VISIBLE-BREAK SWTCH, DOES THIS SWTCH MEET THE <br />REQUIREMENT? YES tr NO tr N/A II <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE <br />REQUIREMENT? YES tr NO E] N/A E <br />3) S|ZE PHOTOVOLTATC POWER SOURCE (DC) CONDUCTORS BASED ON MAX <br />CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT <br />4) SIZE TNVERTER OUTPUT CTRCU|T (AC) CONDUCTORS ACCORDTNG TO TNVERTER <br />OCPD AMPERE RATING (See Guide Section 9) <br />5) TOTAL OF INVERTER OCPD(s), <br />SUPPLY BREA_KERS COMPLY WITH 1206/O <br />YES EI NO tr <br />ONE FOR EACH INVERTER DOES TOTAL <br />BUSBAR ExCEPTION lN 6e0 64(B)(2Xa)? <br />SHEET <br />t <br />a
The URL can be used to link to this page
Your browser does not support the video tag.