My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
20173968 - Permit
PBA
>
Building
>
Permits
>
C
>
Curie Ave
>
1122 W Curie Ave
>
20173968 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2021 8:27:01 AM
Creation date
10/26/2021 8:26:59 AM
Metadata
Fields
Template:
Permit
Permit Number
20173968
Full Address
1122 W Curie Ave
Permit ID
277870
Master ID Number
2021-166498
Project Name
Miscellaneous Counter1 Permit
Street Number
001122
Street Direction
W
Street Name
Curie
Street Suffix
Ave
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
8/12/2021
Issued Date
8/12/2021
Finalized Date
9/27/2021
Flood Zone
X-0602320259J
Description of Work
Install new roof mounted solar PV sytsem. ALL ELECTRICAL SOLAR FEES PAID ON 101107496
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Notes for One-Line Standard Electrical <br />Diaqram for Sinqle-Phase PV Systems <br />Contractor Name, <br />Address and Phone: <br />Sitg Name: Doris Grigtey <br />Sitg AddfeSS: 1122 W curie Avenue,santa Ana,cA,e2707 <br />SVstem AC Size: 3.oeekwcEc-Ac <br />Drawn ,r,A. H U <br />StzE FSCM NO DWG NO REV <br />Checked By:SCAtt NTS Date: <br />MODULE MAKE CANADIAN SOLAR <br />MODULE MODEL CS3K-31sMS <br />MAX POWER-PO|NT CURRENT (lr,rp)9.52 A <br />MAX POWER-POINT VOLTAGE (Vrr)33.1 V <br />oPEN-CtRCUIT VOLTAGE (Voc)39.9 V <br />sHoRT-CIRCUtT CURRENT (tsc)10.06 A <br />MAX SERTES FUSE (OCPD)30A <br />MAXTMUM POWER (Puox)315 W <br />MAX VOLTAGE (TYP 600VDc)1 500v <br />VOC TEMP COEFF (mVfC El or %fC g1 -0.29 <br />IF COEFF SUPPL!ED, CIRCLE UNITS <br />stcNS-SEE GUrDE SECTTON Z <br />P\r_MODULE RATINGS @ STC (Guide Section 5) <br />NOTES FOR ALL DRAWINGS: <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODE@ REFERENCES <br />sHowN AS rNEC XXX.Xn <br />INVERTER RATINGS (Guide Section 4) <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E):NOTES FOR INVERTER CIRCUITS (Guide Section I and_9: <br />1.) LOWEST EXPECTAMBIENTTEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP 2 OC <br />2.\ HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE 31 OC <br />?.)2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED <br />47oC lN THE UNTTED STATES (PALM SPRINGS, CA tS 44.1oC). FOR LESS THAN I <br />CURRENT.CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT <br />LEAST 0.5'' ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47oC OR LESS (ALL OF UNTTED STATES), <br />al 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH IsC OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER <br />FUSE. <br />b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH lsc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 1S.AMP OR SMALLER <br />FUSE. <br />SIGN FOR DC DISCONNECT <br />No sign necessary since 690.51 <br />marking on PV module covers <br />needed information <br />SIGN FOR INVERTER OCPD AND AC <br />prscoNNECT (rF usEp) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />AC OUTPUT CURRENT 204 <br />NOMINAL AC VOLTAGE 240V <br />THIS PANEL FED BY MULTIPLE <br />souRcES (uTrLlTY AND SOLAR) <br />INVERTER MAKE ENPHASE ENERGY <br />INVERTER MODEL IQTPLU S-72-x-US 240V <br />MAX DC VOLT RATING 60v <br />MAX POWER @ 4ooc 2gOVA <br />NOMINAL AC VOLTAGE 240V <br />MAX AC CURRENT 1 .21p. <br />MAX OCPD RATING 204 <br />1) tF UTtL|TY REQUTRES A VTSIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE <br />REQUIREMENT? YES g NO tr N/A D <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE <br />REQUTREMENT? YES EI NO tr N/A EI <br />3) S|ZE PHOTOVOLTATC POWER SOURCE (DC) CONDUCTORS BASED ON MAX <br />CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT <br />4) SrZE TNVERTER OUTPUT CTRCUTT (AC) CONDUCTORS ACCORDTNG TO INVERTER <br />OCPD AMPERE RATING. (See Guide Section 9) <br />5) TOTAL OF 1 INVERTER OUTPUT CIRCUIT OCPD(s), ON <br />INVERTER CTRTUTT: DOES TOTAL SUPPLY BREAKERS COMPL <br />EXCEPTIoN lN 6e0.64(B)(2)(a)? YESEI Notr <br />E FOR EACH MICRO. <br />Y WITH 120o/o BUSBAR <br />SHEET <br />Norrs FoR MICRo-INve RTER EIccTRICAL DIAcRAM <br />tt)z <br />].LlFva <br />l-r) <br />C- <br />dol& <br />VAt)1! <br />Ucd <br />=:d <br />t4J <br />c <br />lfJF <br />c <br />rJ.l <br />xr! <br />rn <br />t
The URL can be used to link to this page
Your browser does not support the video tag.