Laserfiche WebLink
= <br />LOAD OUTGRID GEN <br />MOD BUS <br />PARALLEL <br />PARALLEL BATTERY CAN BUS <br />PV1+PV1-PV2+PV2-PV3+PV3- <br />200A LOAD BREAKER <br />L3L2L1 L3L2L1 L3L2L1PV4+PV4- <br />(64) JA SOLAR JAM66D45 LB JA (630W) MODULES <br />(32) AP SMART RSD-D-20 RAPID SHUTDOWN DEVICES <br />MPPT 1 <br />1 STRING OF (08) MODULES <br />WITH (04) AP SMART RSD-D-20 RAPID SHUTDOWN DEVICES <br />1 STRING OF (08) MODULES <br />WITH (04) AP SMART RSD-D-20 RAPID SHUTDOWN DEVICES <br />MPPT 2 <br />1 STRING OF (08) MODULES <br />WITH (04) AP SMART RSD-D-20 RAPID SHUTDOWN DEVICES <br />1 STRING OF (08) MODULES <br />WITH (04) AP SMART RSD-D-20 RAPID SHUTDOWN DEVICES <br />MPPT 3 <br />1 STRING OF (08) MODULES <br />WITH (04) AP SMART RSD-D-20 RAPID SHUTDOWN DEVICES <br />1 STRING OF (08) MODULES <br />WITH (04) AP SMART RSD-D-20 RAPID SHUTDOWN DEVICES <br />MPPT 4 <br />1 STRING OF (08) MODULES <br />WITH (04) AP SMART RSD-D-20 RAPID SHUTDOWN DEVICES <br />1 STRING OF (08) MODULES <br />WITH (04) AP SMART RSD-D-20 RAPID SHUTDOWN DEVICES <br />(N) SOL-ARK 30K-3P-208V-N INVERTER <br />INVERTER OUTPUT CURRENT: 83.4A(208V) <br />48VDC BATTERY INPUT 150-550 VDC PV <br />INPUT WITH MPPT TRACKING BUILT IN <br />ARC FAULT AND GROUND FAULT <br />DETECTION ON PV INPUT CIRCUITS <br />LOAD <br />LINE <br />(N) 200A FUSED AC DISCONNECT <br />WITH (3) 110A FUSES, VISIBLE <br />LOCKABLE LABELED, 120/208V, <br />3-PHASE, 4-W, <br /> NEMA 3R, UL LISTED <br />L1 <br />L2 <br />G <br />L3 <br />(N) JUNCTION BOX <br />600 V, NEMA 3R <br />UL LISTED <br />4 <br />1 <br />EMERGENCY STOP BUTTON <br />ADJACENT TO AC DISCONNECT <br />EXTERIOR WALL <br />LOCATED PER NEC 690.12 <br />3 <br />2X INTEGRATED LOCKING <br />PV DISCONNECT <br />N <br />(E) SUB PANEL PANEL 250A <br />RATED, 120/208V, 3-PHASE, <br />4-W, WYE <br />G <br />(E) MAIN BREAKER 175A/3P, <br />120/208V, 3-PHASE, <br />4-W, WYE <br />N <br />(E) 600A RATED MAIN LUG <br />PANEL, 120/208V, 3-PHASE, <br />4-W, WYE <br />G <br />N <br />(E) SUB PANEL PANEL <br />200A RATED, 120/208V, <br />3-PHASE, 4-W, WYE <br />G <br />(E) MAIN BREAKER 200A/3P, <br />120/208V, 3-PHASE, 4-W, WYE <br />N <br />(E) SUB PANEL PANEL 200A RATED, <br />120/208V, 3-PHASE, 4-W, WYE <br />G <br />(E) MAIN BREAKER 200A/3P, <br />120/208V, 3-PHASE, 4-W, WYE <br />N <br />(N) AC DISCONNECT <br />VISIBLE, LOCKABLE, LABELED <br />600A AC DISCONNECT WITH <br />(3) 600A FUSES, 120/208V, <br />3-PHASE NEMA 3R, UL LISTED <br />(READILY ACCESSIBLE) <br />(E) LOADS <br />(N) <br />100A/3P <br />(N) SOLAR PV BREAKER <br />(E) <br />175A/3P <br />(E) <br />200A/3P <br />(E) <br />200A/3P <br />LOAD <br />LINE <br />(E) 600A FUSED AC DISCONNECT <br />VISIBLE LOCKABLE LABELED <br />DISCONNECT, (3) 200A FUSES, <br />120/240V, 3-PHASE, 4-W NEMA 3R, <br />UL LISTED <br />L1 <br />L2 <br />L3 <br />G <br />#3/0 AWG GEC (CU) <br />112.15KVA TRANSFORMER <br />PRIMARY-277/480V,WYE 3-PHASE <br />SECONDARY-120/208V WYE, <br /> NEMA 3R, UL LISTED <br />N <br />(E) MAIN DISCONNECT <br />SWITCHGEAR 2500A RATED, <br />277/480V, 3-PHASE, 4-W, WYE <br />EXISTING GROUNDING <br />ELECTRODE SYSTEM TO EARTH <br />REF. CEC 250.52, 250.53(A) <br />G <br />(E) MAIN BONDING <br />JUMPER PER <br />CEC 250.8 & 250.28 <br />(E) BONDING JUMPER <br />PER CEC 250.92(A)(2) <br />(E) GROUNDING ELECTRODE <br />CONDUCTOR PER CEC 250.62,250.64, <br />& 250.66 <br />(E) GROUNDING ELECTRODE <br />SYSTEM PER CEC 250.50 <br />(E) MAIN BREAKER 2500A/3P, <br />277/480V, 3-PHASE, 4-W, WYE <br />M <br />(E) <br />2500A/3P <br />TO UTILITY GRID <br />L2L1 NL3 <br />(E) (04) 600 KCMIL ALUMINIUM <br />(01) #2 GROUND <br />(E) 2 PARALLEL FEEDER OF <br />(04) 600 KCMIL ALUMINIUM <br />(01) #2 GROUND <br />(E) (04) 350 KCMIL ALUMINIUM <br />(01) #2 GROUND EXISTING <br />2 LOAD <br />LINE <br />E <br />(E) SERVICE DISCONNECT <br />277/480V, 3-PHASE, 4-W, WYE <br />(E) 2 PARALLEL FEEDER OF <br />(04) 600 KCMIL ALUMINIUM <br />(01) #2 GROUND <br />E <br />MAIN LUG ONLY <br />(E) LOADS (E) LOADS <br />PV-02 <br />ARCH D (24" X 36") PRINT PAPER SIZE <br />NO DATE DESCRIPTION ELECT. <br />05/05/2026 SLD ONLY 01 <br />DESCRIPTION: <br />DESIGN BY <br />EMAIL: PROJECT@TECHVERSESMARTSOLUTIONS.COM <br />PHONE NO: +1 (626) 548-7535 <br />REVIEWED BY Jogindar Kumar <br />DRAWN BY Shubham Parab <br />ELECTRICAL <br />LINE DIAGRAM <br />ELECTRICAL <br />LINE DIAGRAM <br />SCALE: NTS <br />705.12(B)(2)(3)(B): LOAD SIDE CONNECTION OPPOSITE <br />END OF BUSBAR FROM MAIN BREAKER/FUSED FEEDER <br />PV CONT. OUTPUT + MAIN < 120% BUSBAR RATING <br />110A + 175A < 1.2 X 250A <br />285A < 300A <br />Vmax = Voc + ((TLow - TStc) x (VocCoef x Voc/100)) <br />Vmax = 48.90+ ((1ºC - 30ºC) x (-0.250 x 48.90/100) <br />Vmax = 48.90 + (-29 x -0.122) <br />Vmax = 52.43 <br />= 550/52.43 <br />= 10.49 (Maximum Number of Modules in Series) <br />CABLE CABLE TYPE CABLE VOLTAGE <br />RATING (V) <br />CABLE TEMP <br />RATING <br />DISTANCE ABOVE ROOF <br />TO BOTTOM OF CONDUIT <br />ADJUSTED AMBIENT <br />TEMP (°C)CONDUIT CONDUIT TYPE <br /># OF <br />CONDUCTORS PER <br />PHASE <br />WIRE/BUS SIZE NEUTRAL GROUND <br />TOTAL CC <br />CONDUCTORS IN <br />RACEWAY <br />BASE <br />AMPACITY <br />(A) <br />DERATING FACTOR FOR <br />CONDUCTORS CEC <br />310.15(B)(3)(A) <br />DERATING FACTOR FOR <br />AMBIENT TEMP CEC <br />310.15(B)(2)(a) <br />OVERALL DERATING <br />FACTOR <br />DERATED <br />AMPACITY (A) <br />CIRCUIT <br />LOAD (A) <br />CIRCUIT LOAD (A) <br />(156%DC, 125% AC, <br />125%OPT, <br />100%BATT) <br />MINIMUM <br />OCPD PER <br />LOAD <br />CONDUCTORS IN <br />CONDUIT <br />EST. <br />DISTANCE FT <br />VOLTAGE <br />DROP %VD <br />1 PV-WIRE/ <br />USE-2, CU 1000 90°C (194°F) Cu ABOVE 7/8"30 N/A FREE AIR 1 SET(S) OF #10 NA #6 16 40 100%100%100%40 16.18 25.24 30 N/A 60 0.65% <br />2 PV-WIRE/ <br />USE-2, CU 1000 90°C (194°F) Cu ABOVE 7/8"30 1-1/2"EMT 1 SET(S) OF #8 NA #10 16 55 50%100%70%27.5 16.18 25.24 30 (16) #8, (1) #10 50 0.36% <br />3 THWN-2 208 90°C (194°F) Cu NOT ON ROOF 30 1-1/4"EMT 1 SET(S) OF #2 #6 #6 3 130 100%100%100%130 83.4 104.25 110 (3) #2, (1) #6, (1) #6 10 0.17% <br />4 THWN-2 208 90°C (194°F) Cu NOT ON ROOF 30 1-1/4"EMT 1 SET(S) OF #2 #6 #6 3 130 100%100%100%130 83.4 104.25 110 (3) #2, (1) #6, (1) #6 10 0.17% <br />AMBIENT TEMPERATURE SPECS <br /> RECORD LOW TEMP 5° <br /> AMBIENT TEMP (HIGH TEMP 2%)30° <br /> CONDUIT HEIGHT 7/8" <br /> ROOF TOP TEMP 30° <br /> CONDUCTOR TEMPERATURE RATE 90° <br />MODULE SPECIFICATIONS <br />MODULE MANUFACTURER: JA SOLAR <br />MODULE MODEL:JA SOLAR JAM66D45 LB JA (630W) MODULES <br />Parameters (DC):Output (AC): <br />LOCAL TEMPERATURE (°C):-40°C TO +85°C Voc:48.90 V STC Power:630 W <br />COLDEST DAY VOC:48.90 V Vmp:40.70 V <br />WARMEST DAY VMP:40.70 V <br />Isc:17.47 A <br />Pmax Temp. Coeff.: -0.290 %/°C <br />MAXIMUM FUSE RATING 35 A <br />Imp:16.72 A <br />Voc Temp. Coeff.-0.250 %/°C <br />Max System Voltage:1500VDC <br />PERCENT OF VALUES NUMBER OF CURRENT <br />CARRYING CONDUCTORS IN EMT <br />0.80 4-6 <br />0.70 7-9 <br />0.50 10-20 <br />INVERTER SPECIFICATIONS: <br />INVERTER MANUFACTURER:SOL-ARK MAX STRING VOLTAGE : 1000VDC <br />TEMP. FACTOR OF MODULE: -0.260%/°C <br />INVERTER TYPE:SOL-ARK COMMERCIAL 30K-3P-208V <br />HYBRID INVERTER <br />INPUT (DC):OUTPUT (AC): <br />MAXIMUM DC POWER (STC):39,000 W <br />MAXIMUM INPUT DC VOLTAGE:550 VDC <br />OPERATING VOLTAGE RANGE:150 – 500 VDC <br />MAXIMUM INPUT CURRENT:36 A <br />TRANSFORMER-LESS: YES <br />INVERTER EFFICIENCY:96.5 % <br />RATED AC ACTIVE OUTPUT POWER: 30,000 W <br />NOMINAL OUTPUT VOLTAGE (L-L): 208V 3-PHASE <br />AC FREQUENCY:60 HZ <br />MAX. CONTI. OUTPUT CURRENT : 83.4 A <br />AMBIENT TEMPERATURE:-40°C TO -60°C <br />PROTECTION RATING:IP65 <br />ELECTRICAL NOTES: <br />1. ALL CONDUCTORS SHALL BE COPPER. COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. <br />2. MODULES AND RACKING GROUNDING METHOD – ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE <br />MANUFACTURER’S INSTALLATION INSTRUCTIONS – UL 2703 COMPLIANT ON IRONRIDGE XR INTEGRATED GROUNDING SYSTEM. <br />3. USING UFO GROUNDING MID CLAMPS AND BOLT GROUNDING LUGS – SEE ATTACHED CUT SHEET. <br />4. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, A GROUNDING ELECTRODE ROD <br />SHALL BE INSTALLED, WHERE #8 THWN-2 GROUND SERVES AS BOTH EQUIPMENT GROUND AND GROUNDING ELECTRODE <br />CONDUCTOR. SUPPLEMENTAL GROUNDING ELECTRODE REQUIRED WHERE EXISTING GROUNDING ELECTRODE HAS RESISTANCE OF <br />MORE THAN 25 OHMS, OR IF RESISTANCE TESTING RESULTS ARE NOT PROVIDED (CEC 690.47(A)). IF REQUIRED, MULTIPLE GROUNDING <br />ELECTRODES MUST BE AT LEAST 6 FT APART (CEC 250.53(A)(3)). <br />5. THE GEC/EGC SHALL BE CONTINUOUS, OR WHEN SPLICED, THE SPLICE SHALL BE MADE BY IRREVERSIBLE CRIMP OR EXOTHERMIC <br />WELD. <br />6. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE <br />GROUNDED IN ACCORDANCE WITH NEC 250.13 OR 250.136(A), REGARDLESS OF VOLTAGE. <br />7. MARKING WILL BE PROVIDED IN ACCORDANCE WITH CALIFORNIA SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINES. <br />8. UTILITY WILL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR INSTALLATION. SYSTEM WILL BE COMMISSIONED BY OWNER <br />PER UTILITY INTERCONNECTION AGREEMENT. <br />9. AC AND DC CONDUCTOR SIZING AND TERMINATIONS AT JUNCTION BOXES WERE CALCULATED IN ACCORDANCE WITH CEC. ALL WIRES <br />TO BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRIES TO JUNCTION BOXES AS REQUIRED BY THE BOX LISTING. <br />10. DC SOURCE AND OUTPUT CIRCUITS SHALL BE CONTAINED IN A METAL RACEWAY/ENCLOSURE WITHIN A BUILDING (ATTIC/WALLS) AND <br />SHALL BE IDENTIFIED EVERY 10 FT PER NEC 690.31(E). <br />Core Investments1600 N BroadwaySanta Ana, CA 92706Office Building/ Commercial <br />Contractor / Designer Os Electric Group Inc. 619-942-46688910 University Ln San Diego, CACA C-10 License # 1133290