My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
406 S Western Ave Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Western Ave
>
406 S Western Ave Unit# 2
>
406 S Western Ave Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2026 5:00:15 AM
Creation date
6/13/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101125303
Full Address
406 S Western Ave Unit# 2
Street Number
406
Street Direction
S
Street Name
Western
Street Suffix
Ave
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Company:Date:12/29/2025 <br />Engineer:Page:4 <br />Project: <br />Address: <br />Phone: <br />E-mail: <br />Anchor Designer™ for <br />Concrete Software <br />Version 3.4.2512.1 <br />4. Steel Strength of Anchor in Tension (Sec. 17.6.1) <br />Nsa (lb)Nsa (lb) <br />35133 0.75 26350 <br />5. Concrete Breakout Strength of Anchor in Tension (Sec. 17.6.2) <br />Nb = kc a f’chef1.5 (Eq. 17.6.2.2.1) <br />kc a f’c (psi)hef (in)Nb (lb) <br />24.0 1.00 2500 5.000 13416 <br />Ncb =(ANc / ANco)ed,N c,N cp,NNb (Sec. 17.5.1.2 &Eq. 17.6.2.1a) <br />ANc (in2)ANco (in2)ca,min (in)ed,N c,N cp,N Nb (lb)Ncb (lb) <br />302.24 225.00 17.00 1.000 1.25 1.000 13416 0.70 15769 <br />6. Pullout Strength of Anchor in Tension (Sec. 17.6.3) <br />Npn =c,PNp =c,P8Abrgf’c (Sec. 17.5.1.2, Eq. 17.6.3.1 &17.6.3.2.2a) <br />c,P Abrg (in2)f’c (psi)Npn (lb) <br />1.4 3.68 2500 0.70 72170 <br />7. Results <br />Interaction of Tensile and Shear Forces (Sec. 17.8) <br />Tension Factored Load,Nua (lb)Design Strength, øNn (lb)Ratio Status <br />Steel 9540 26350 0.36 Pass <br />Concrete breakout 9540 15769 0.60 Pass (Governs) <br />Pullout 9540 72170 0.13 Pass <br />1"Ø F1554 Gr. 36 (2.50 x 2.50 x 0.38) with hef = 5.000 inch meets the selected design criteria. <br />8. Warnings <br />-Designer must exercise own judgement to determine if this design is suitable. <br />-Projected breakout area ANc is limited per ACI 318-19 Section 17.6.2.1.3. <br />Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. <br />Simpson Strong-Tie Company Inc.5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com <br />72
The URL can be used to link to this page
Your browser does not support the video tag.