Laserfiche WebLink
SLAB OR WOOD FRAME <br />SLIDING DOOR <br />PROTECTO WRAP <br />MEMBRANE OR <br />PROTECTO DECK <br />DECK LEDGER BOARD <br />1. PROTECTOWRAP <br />2. REFER TO TECHNICAL DATA SHEET FOR MORE INFORMATION <br />3. PROTECTO WRAP UNDERLAYMENTS SHOULD BE INSTALLED TO FORM WATER-SHEDDING LAPS <br />4. ALL SURFACES MUST BE CLEAN, DRY, FREE OF DIRT AND OTHER FOREIGN MATERIALS. <br />5. CUT A PIECE OF PROTECTO PREMIUM DUAL GUARD THRESHOLD TAPE THE LENGTH OF THE THRESHOLD OPENING EXTENDING <br />APPROXIMATELY 1" MINIMUM UP THE SIDES OF THE DOOR JAM. <br />6. PEEL OFF RELEASE LINER AND BEGIN APPLYING PROTECTO PREMIUM DUAL GUARD THRESHOLD TAPE TO THE DOOR SILL PLATE BY <br />SMOOTHING AS THE ADHESIVE COMES INTO CONTACT WITH THE DOOR SILL. <br />7. PLACE THE THRESHOLD OVER THE PROTECTO PREMIUM DUAL GUARD THRESHOLD TAPE AND SECURE. <br />PROTECTO SEALANT 25XL <br />PROTECTO PREMIUM <br />DUAL GUARD THRESHOLD TAPE <br />DOOR THRESHOLD <br />EXTERIOR DOOR SILL CROSS SECTION SHOWING <br />PROTECTO PREMIUM DUAL GUARD THRESHOLD TAPE <br />1. PROTECTO WRAP <br />2. REFER TO TECHNICAL DATA SHEET FOR MORE INFORMATION <br />3. PROTECTO WRAP UNDERLAYMENTS SHOULD BE INSTALLED TO FORM WATER-SHEDDING LAPS <br />4. ALL SURFACES MUST BE CLEAN, DRY, FREE OF DIRT AND OTHER FOREIGN MATERIALS. <br />5. CUT A PIECE OF PROTECTO PREMIUM DUAL GUARD THRESHOLD TAPE THE LENGTH OF THE THRESHOLD <br />OPENING EXTENDING APPROXIMATELY 1" MINIMUM UP THE SIDES OF THE DOOR JAM. <br />6. PEEL OFF RELEASE LINER AND BEGIN APPLYING PROTECTO PREMIUM DUAL GUARD <br /> THRESHOLD TAPE TO THE DOOR SILL PLATE BY SMOOTHING AS THE ADHESIVE COMES INTO CONTACT WITH <br />THE DOOR SILL. <br />7. PLACE THE THRESHOLD OVER THE PROTECTO PREMIUM DUAL GUARD THRESHOLD TAPE AND SECURE. <br />SLAB OR WOOD FRAME <br />SWING DOOR <br />PROTECTO SEALANT 25XL <br />PROTECTO PREMIUM <br />DUAL GUARD THRESHOLD TAPE <br />DOOR THRESHOLD <br />PROTECTO WRAP <br />MEMBRANE OR <br />PROTECTO DECK <br />DECK LEDGER BOARD <br />EXTERIOR DOOR SILL CROSS SECTION SHOWING <br />PROTECTO PREMIUM DUAL GUARD THRESHOLD TAPE <br />1. PROTECTOWRAP <br />2. REFER TO TECHNICAL DATA SHEET FOR MORE INFORMATION <br />3. PROTECTO WRAP UNDERLAYMENTS SHOULD BE INSTALLED TO FORM WATER-SHEDDING LAPS <br />4. INSTALL PROTECTO WRAP PRODUCTS IN ORDER AS SHOWN BY NUMBERS <br />5. SCORE AND FOLD WEATHER RESISTIVE BARRIER ABOVE HEADER TO ALLOW PROTECTO WRAP PRODUCTS <br /> TO BE INSTALLED <br />6. INSTALL HEAD FLASHING UNDER WEATHER RESISTIVE BARRIER; MECHANICALLY FASTEN AS NECESSARY <br />7. FOLD WEATHER RESISTIVE BARRIER BACK OVER HEAD FLASHING AND SEAL EDGES <br />2 <br />3 <br />WEATHER RESISTIVE <br />BARRIER (CHECK LOCAL <br />BUILDING CODE FOR <br />REQUIREMENTS) <br />2 MECHANICALLY FASTEN <br />AS NECESSARY IN <br />CORNERS THROUGH <br />PROTECTO WRAP <br />MEMBRANE <br />4 <br />4 <br />5 <br />EXTERIOR SHEATHING <br />FOLD UP WEATHER <br />RESISTIVE BARRIER AND <br />TEMPORARILY SECURE <br />1 <br />1 <br />PROTECTO WRAP <br />MEMBRANE <br />SILL PLATE <br />SEAL TOP OF JOISTS <br />UNDER DECKING <br />WITH PROTECTO DECK <br />ACQ FLASHING TAPE <br />PROTECTO WRAP MEMBRANE <br />OR PROTECTO DECK <br />ACQ FLASHING TAPE <br />BEHIND WRB <br />SEE PW-PD05 <br />PROTECTO DETAIL TAPE WRAP <br />CUT WRB BACK <br />FROM OPENING <br />EXTERIOR SLIDING DOOR WITH DECK FLASHING <br />INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />1. PROTECTOWRAP <br />2. REFER TO TECHNICAL DATA SHEET FOR MORE INFORMATION <br />3. PROTECTO WRAP UNDERLAYMENTS SHOULD BE INSTALLED TO FORM <br /> WATER-SHEDDING LAPS <br />1 <br />WEATHER RESISTIVE <br />BARRIER OVER PW <br />MEMBRANE (CHECK LOCAL <br />BUILDING CODE FOR <br />REQUIREMENTS) <br />DOOR ROUGH OPENING <br />PROTECTO PREMIUM DUAL GUARD <br />THRESHOLD TAPE, WRAPPED UP <br />SIDES 1" <br />SUBFLOOR <br />RIM JOIST <br />PROTECTO WRAP <br />MEMBRANE OR <br />PROTECTO DECK ACQ <br />FLASHING TAPE <br />3 <br />PROTECTO DECK <br />ACQ FLASHING TAPE <br />SEAL TOP OF JOISTS <br />UNDER DECKING <br />2 <br />PROTECTO DECK <br />ACQ FLASHING TAPE <br />UNDER HANGERS <br />PROTECTO WRAP DETAIL TAPE <br />EXTERIOR DOOR SILL CORNER <br />ATTACH SILL STRIP WITH TOP EDGE LEVEL WITH <br />ROUGH SILL; EXTEND BEYOND EDGE OF ROUGH <br />OPENING AT LEAST 8". SECURE ALL BUILDING PAPER <br />OR SIMILAR APPROVED FLASHING MATERIAL WITH <br />GALVANIZED NAILS OR POWER DRIVEN STAPLES. <br />ATTACH JAMB STRIPS WITH SIDE EDGE EVEN WITH <br />ROUGH-JAMB FRAMING. START STRIP 1" BELOW <br />LOWER EDGE OF SILL STRIP AND EXTEND 4" ABOVE <br />LOWER EDGE OF LINTEL. <br />INSTALL WINDOW INTO ROUGH OPENING WITH SILL <br />AND JAMB FLANGES OVER PREVIOUSLY INSTALLED <br />FLASHING. ATTACH HEAD FLASHING OVER THE <br />WINDOW FLANGE. <br />COMMENCING AT THE BOTTOM(SOLE PLATE) OF THE WALL, LAY <br />BUILDING PAPER UNDER SILL STRIP. CUT ANY EXCESS BUILDING <br />PAPER THAT MAY EXTEND CUT ANY EXCESS BUILDING PAPER <br />THAT MAY EXTEND ABOVE THE SILL FLANGE LINE ON EACH SIDE <br />OF OPENING (SHOWN AS DASHED LINE). DO NOT CUT BUILDING <br />PAPER HORIZONTALLY SO THE PAPER WILL LAP OVER THE JAMB <br />STRIPS. INSTALL SUCCESSIVE LINES OF BUILDING PAPER (B,C,D <br />ETC) OVER JAMB AND HEAD FLANGES, LAPPING EACH COURSE. <br />WINDOW FLASHING DETAIL <br />1. PROTECTO WRAP <br />2. REFER TO TECHNICAL DATA SHEET FOR MORE INFORMATION <br />3. PROTECTO WRAP UNDERLAYMENTS SHOULD BE INSTALLED TO FORM WATER-SHEDDING LAPS <br />SILL PLATE <br />WALL SHEATHING <br />PROTECTO WRAP <br />DETAIL TAPE <br />IN LOWER <br />CORNERS <br />PROTECTO SILL <br />DRAINAGE SYSTEM <br />BEAD OF PROTECTO <br />SEALANT 25XL IN CORNER, <br />AT EDGE OF PSDS <br />PROTECTO WRAP <br />MEMBRANE, OVER WRB <br />AND DETAIL TAPE, UNDER <br />PSDS <br />WRB "BIB" <br />PROTECTO WRAP <br />MEMBRANE <br />PROTECTO SILL <br />DRAINAGE SYSTEM <br />1 <br />3 <br />2 <br />WRB "BIB" INSTALLED TO <br />ALLOW MIN. 1" ADHESION <br />OF FLASHING TO <br />SHEATHING <br />PROTECTO SEALANT <br />25XL, OPTIONAL <br />ALONG TOP <br />EDGE OF PSDS <br />BACKDAM <br />1. PROTECTOWRAP <br />2. REFER TO TECHNICAL DATA SHEET FOR MORE INFORMATION <br />3. PROTECTO WRAP UNDERLAYMENTS SHOULD BE INSTALLED TO FORM WATER-SHEDDING LAPS <br />4. PROTECTO WRAP COMPANY RECOMMENDS AN INTERIOR AIR SEAL WHEN USING THESE OPTIONS <br />OPTION B <br />SILL PLATE <br />"L" METAL OR <br />EQUIVALENT <br />BACKDAM <br />RECOMMENDED <br />OPTION A <br />PROTECTO WRAP MEMBRANE <br />COMPATIBLE <br />TAPERED <br />WOOD SIDING <br />SILL PLATE <br />WALL SHEATHING <br />PROTECTO WRAP <br />DETAIL TAPE <br />PROTECTO WRAP <br />MEMBRANE <br />PROTECTO WRAP MEMBRANE <br />WALL SHEATHING <br />PROTECTO WRAP <br />DETAIL TAPE <br />PROTECTO WRAP <br />MEMBRANE <br />PROTECTO SEALANT 25XL <br />WRB "BIB" INSTALLED TO <br />ALLOW MIN. 1" ADHESION <br />OF SILL FLASHING TO <br />SHEATHING <br />WRB "BIB" INSTALLED TO <br />ALLOW MIN. 1" ADHESION <br />OF SILL FLASHING TO <br />SHEATHING <br />WINDOW SILL PAN PROTECTO SILL <br />DRAINAGE SYSTEM <br />WINDOW SILL PAN OPTIONS A & B <br />WEATHER <br />RESISTIVE <br />BARRIER <br />(OPTIONAL) <br />PROTECTO <br />WRAP <br />UNDERLAYMENT <br />WALL SHEATHING <br />PROTECTO WRAP <br />DETAIL TAPE <br />CONTINUOUS BEAD OF <br />PROTECTO WRAP <br />JS160 H MASTIC <br />PROTECTO <br />WRAP <br />UNDERLAYMENT <br />SL <br />O <br />P <br />E <br />1. PROTECTO WRAP <br />2. REFER TO TECHNICAL DATA SHEET FOR MORE INFORMATION <br />3. PROTECTO WRAP UNDERLAYMENTS SHOULD BE INSTALLED <br /> TO FORM WATER-SHEDDING LAPS <br />4. EDGE LAPS ARE MINIMUM 2" AND END LAPS ARE MINIMUM 6"- <br /> REFER TO TECHNICAL DATA SHEET FOR PRODUCT SPECIFIC REQUIREMENTS <br />SLOPE <br />ROOF <br />DECK <br />1. PROTECTOWRAP <br />2. REFER TO TECHNICAL DATA SHEET FOR MORE INFORMATION <br />3. EXTEND PROTECTO WRAP UNDERLAYMENT ON THE WALL SHEATHING ABOVE THE HIGHEST EXPECTED LEVEL OF SNOW AND <br />ICE <br />3. EXTEND PROTECTO WRAP UNDERLAYMENT ON THE ROOF DECK ABOVE THE HIGHEST EXPECTED LEVEL OF WATER BACK-UP <br />FROM ICE DAMS <br />4. EXTEND PROTECTO WRAP UNDERLAYMENT BEYOND EAVE ONTO VERTICAL SIDE WALL <br />5. THE METAL FLASHING IS INSTALLED OVER THE PROTECTO WRAP UNDERLAYMENT <br />6. INSTALL PROTECTO WRAP UNDERLAYMENT IN ORDER AS SHOWN BY NUMBERS <br />7. PROTECTO WRAP UNDERLAYMENTS SHOULD BE INSTALLED TO FORM WATER-SHEDDING LAPS <br />8. EDGE LAPS ARE MINIMUM 2" AND END LAPS ARE MINIMUM 6"- REFER TO TECHNICAL DATA SHEET FOR PRODUCT SPECIFIC <br />REQUIREMENTS <br />METAL DRIP EDGE <br />BY OTHERS <br />ROOF DECK <br />VERTICAL <br />SIDEWALL <br />PROTECTO WRAP <br />UNDERLAYMENT <br />KICK OUT FLASHING <br />(OPTIONAL) <br />EXPOSED ROOF <br />COVERING <br />EXPOSED WALL <br />COVERING <br />WEATHER RESISTIVE <br />BARRIER (OPTIONAL) <br />METAL STEP <br />FLASHING <br />CONTINUOUS BEAD OF <br />JS 160 H MASTIC <br />PROTECTO WRAP <br />UNDERLAYMENT <br />PROTECTO WRAP <br />UNDERLAYMENT <br />CONTINUOUS BEAD OF <br />JS 160 H MASTIC AT SEAMS <br />1 <br />4 <br />3 <br />2 <br />1 <br />2 <br />1 <br />EXTEND PROTECTO WRAP <br />UDERLAYMENT ABOVE HIGHEST <br />EXPECTED LEVEL OF SNOW AND <br />ICE BUILD-UP <br />VERTICAL SIDE WALL <br />1. VALLEYS REQUIRE A MINIMUM 18" WIDE ROLL CENTERED DOWN THE FULL LENGTH OF THE VALLEY <br />2. INSTALL MEMBRANE STARTING AT THE LOWEST POINT OF ROOF SLOPE AND WORK UP THE SLOPE <br />3. PROTECTO WRAP UNDERLAYMENTS SHOULD BE INSTALLED TO FORM WATER-SHEDDING LAPS <br />4. INSTALL IN ORDER AS SHOWN BY NUMBERS <br />5. REFER TO TECHNICAL DATA SHEET FOR MORE INFORMATION <br />6. VISIT PROTECTOWRAP.COM FOR THE MOST CURRENT INFORMATION <br />1 <br />2 <br />26" min. <br />PROTECTO WRAP <br />UNDERLAYMENT <br />LAP <br />VALLEY FLASHING DETAIL <br />9" min <br />. <br />OUTSIDE CORNER WALL TO ROOF DECK 3 <br />2 <br />1 <br />7 <br />6 <br />5 <br />11 <br />10 <br />9 <br />8 <br />4 <br />CLASS A FIRE RESISTANT <br />ROOFING / ROOF ASSEMBLY <br />SOLID BLOCKING <br />FROM TOP PLATE TO UNDER <br />SIDE OF ROOF SHEATING. <br />EAVES BETWEEN 2 AND 5 FEET : <br />7/8" STUCCO FINISH <br />CLASS A FIRE RESISTANT <br />ROOFING / ROOF ASSEMBLY <br />FIRE RESISTANT EXTERIOR WALL <br />AND EAVE PROTECTION (TYP.) <br />EN <br />EN <br />EN <br />45° <br />PROTECT UNDERSIDE OF <br />EAVE WITH 1-HOUR PROTECTION AND <br />NO EAVES VENTS. STUCCO FINISH (TYP.) <br />EAVES BETWEEN 2 AND 5 FEET : <br />PROTECT UNDERSIDE OF <br />EAVE WITH 1-HOUR PROTECTION AND <br />EAVES BETWEEN 2 AND 5 FEET : <br />FIRE RESISTANT EXTERIOR WALL <br />AND EAVE PROTECTION (TYP.) <br />FR2FR1 <br />11 <br />5/8" TYPE "X" GYP BD. <br />2X4 STUD WALL WITH R-15 INSULATION <br />5/8" TYPE "X" GYP BD. <br />2X4 STUD WALL WITH R-15 INSULATION <br />OPENINGS PER STORY (DOORS, WINDOWS, MECHANICAL VENTS, <br />SCUPPERS) ARE ALLOWED WHERE THE CUMULATIVE AREA OF THE <br />OPENINGS NOT EXCEED 25% OF THE EXTERIOR WALL AREA PER STORY <br />5'-5" <br />5'-0" <br />5'-5" <br />5'-0" <br />7/8" STUCCO FINISH <br />OPENINGS PER STORY (DOORS, WINDOWS, MECHANICAL VENTS, <br />SCUPPERS) ARE ALLOWED WHERE THE CUMULATIVE AREA OF THE <br />OPENINGS NOT EXCEED 25% OF THE EXTERIOR WALL AREA PER STORY <br />NO EAVES VENTS. STUCCO FINISH (TYP.) <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />OF <br />SHEET NO. <br />DATE ISSUED DRAWN BY <br />CHECKED BY SCALE <br />PRINT:REVISION: <br />SH <br />E <br />E <br />T <br /> <br /> <br />N <br />A <br />M <br />E <br />: <br />THESE DRAWINGS, DESIGN AND SPECIFICATIONS ARE THE PROPERTY AND COPY RIGHT OF YOLANDA CASTRO AND/OR C+P DESIGN CONSTULTANTS AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH YOLANDA CASTRO. WRITTEN DIMENSIONS SHALL TAKE REFERENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE, ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF YOLANDA CASTRO TO THE COMMENCEMENT OF ANY WORK <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />OW <br />N <br />E <br />R <br />: <br />AD <br />D <br />R <br />E <br />S <br />S <br />: <br />Y.C. <br />C+P <br />25 <br />C <br />P <br />0 <br />0 <br />6 <br />1 <br />AS SHOWN <br />5/3/2025 <br />STAMP APPROVAL <br />11-05-2025 <br />A. <br />P <br />. <br />N <br />. <br />40 <br />6 <br /> <br />S <br /> <br />W <br />e <br />s <br />t <br />e <br />r <br />n <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br /># <br />2 <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />NE <br />W <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />Ma <br />t <br />i <br />a <br />s <br /> <br />M <br />i <br />r <br />a <br />n <br />d <br />a <br />00 <br />7 <br />- <br />2 <br />2 <br />3 <br />- <br />0 <br />6 <br />12-22-2025 <br />2 01-20-2026 02/27/2026 <br />01-A2 <br />FL <br />A <br />S <br />H <br />I <br />N <br />G <br /> <br />D <br />E <br />T <br />A <br />I <br />L <br />S