My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
220 S Daisy Ave & Unit MET01 - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Daisy Ave
>
220 S Daisy Ave
>
220 S Daisy Ave & Unit MET01 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2026 5:00:11 AM
Creation date
6/17/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20188356
20188758
101127088
Full Address
220 S Daisy Ave
220 S Daisy Ave Unit# MET01
Street Number
220
Street Direction
S
Street Name
Daisy
Street Suffix
Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project: <br />Project No.: <br />Date: <br />BASIS OF DESIGN <br />•2025 California Building Code <br />•ASCE 7-22 Minimum design loads for buildings and other structures <br />•2019 ACI 318-19 Building Code Requirements for Structural Concrete <br />Material Specifications & Strengths <br />•Concrete* 3,000 psi specified, design for 2,500 psi <br />•Reinforcing Steel Fy = 60 ksi <br />Allowable Soil Pressures <br />Max Bearing Pressure: <br />Lateral Soil Pressure: <br />Seismic Design Data: ASCE 7-22 Wind Design Data: ASCE 7-22 <br />Risk Category II Basic Wind Speed V=mph <br />Seismic Importance Factor Ie=Exposure Category <br />Mapped Acceleration SS=g Gust Factor G = <br />Mapped Acceleration S1=g Velocity Pressure Coefficient Kz= <br />Design Spectral Acceleration SDS=g Directionality Factor Kd= <br />Design Spectral Acceleration SD1=g Topographic Factor Kzt= <br />Site Class DEFAULT <br />Seismic Design Category D <br />Analysis Procedure Nonstructural Components <br />Components <br />Switchboard <br />Transformer <br />2.0 2.001.0 1.4 <br />City of Santa Ana Corp Yard <br />1.170 0.85 <br />5/1/2026 <br />26035 <br />1.00 <br />*Concrete is exempt from special inspections per CBC 2025 1705.3 Exceptions 1. TKJSE is voluntarily specifying Mix Design on plan <br />to ensure a qualified inspector reviews and verifies compliance with the specifications prior to concrete placement to maintain <br />quality assurance. <br />0.820 1.00 <br />1500 psf** 1/3 increase permitted for load cases <br />including short-term loads <br />95 <br />1.49 <br />0.56 0.85 <br />100 psf* <br />2.00 <br />C <br />0.85 <br />1.0 1.4 1.5 <br />Ip CAR Rpo Ωop <br />3 of 32
The URL can be used to link to this page
Your browser does not support the video tag.