My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2124 N Ross St - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Ross St
>
2124 N Ross St
>
2124 N Ross St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2026 5:38:00 AM
Creation date
6/19/2026 5:00:17 AM
Metadata
Fields
Template:
Plan
Permit Number
101126497
Full Address
2124 N Ross St
Street Number
2124
Street Direction
N
Street Name
Ross
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A <br />B <br />1 2 3 <br />GARAGE ADU CONVERSION <br />2120/2124 N ROSS ST <br />SANTA ANA, CA, 92706 <br />25-1022 <br />6/16/2025 <br />3/8" = 1'-0" <br />S101 <br />Jeffrey Schaefer, P.E. <br />(562) 850-1223 <br />License Number - C91734 <br />Expiration Date - Dec 31, 2026 <br />3325 E 4th St. <br />Long Beach, CA 90814 <br />FOUNDATION <br />PLAN <br />1 2 3 <br />A <br />B <br />N <br />STRUCTURAL ENGINEERING <br />1. ON SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY OF THE <br />CONTRACTOR AND SUB-CONTRACTORS. NOTES AND DIMENSIONS TAKES PRECEDENCE OVER SCALING OF <br />THE DRAWING. EACH CONTRACTOR OR SUB-CONTRACTOR SHALL REPORT TO PROJECT OWNER AND <br />DESIGNER ALL CONDITIONS WHICH PREVENT THE PROPER EXECUTION OF THEIR WORK. REFER TO <br />ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS <br />2. NO DEVIATIONS FROM STRUCTURAL DETAILS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF THE <br />STRUCTURAL DESIGN ENGINEER. APPROVAL BY CITY INSPECTOR DOES NOT CONSTITUTE AUTHORITY TO <br />DEVIATE FROM PLANS OR SPECIFICATIONS. <br />3. STRUCTURAL DESIGN DOES NOT CONSIDER EFFECTS OF MECHANICAL EQUIPMENT. <br />4. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS <br />SOLE RESPONSIBILITY OF THE CONTRACTOR AND HAS NOT BEEN CONSIDERED BY THE ENGINEER. THE <br />CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE PRIOR TO THE APPLICATION OF ALL <br />SHEAR WALLS, ROOF AND FLOOR DIAPHRAGMS AND FINISH MATERIALS. <br />STRUCTURAL DESIGN CRITERIA <br />1. SOIL BEARING CAPACITY ASSUMED TO BE 1,500 PSF <br />2. DESIGN VALUES ARE BASED OFF THE FOLLOWING CRITERIA: <br />2.1. RISK CATEGORY: II <br />2.2. GROUND FLOOR LIVE LOAD: 40 PSF <br />2.3. ROOF LIVE LOAD: 20 PSF <br />2.4. ROOF DEAD LOAD: 15 PSF (19 PSF WHERE SOLAR PANELS) <br />2.5. FLOOR LIVE LOAD: 30 PSF (BEDROOM AREA) <br />2.6. FLOOR LIVE LOAD: 40 PSF (OTHER AREAS) <br />2.7. FLOOR DEAD LOAD: 10 PSF <br />2.8. GROUND SNOW LOAD: 0 PSF <br />2.9. BASIC WIND SPEED: 95 MPH <br />2.10. EXPOSURE CATEGORY: B <br />2.11. ENCLOSURE CLASSIFICATION: ENCLOSED <br />2.12. SEISMIC SITE CLASS: D <br />2.13. SEISMIC DESIGN CATEGORY: D <br />2.14. RESPONSE MODIFICATION FACTOR: 6.5 <br />2.15. SEISMIC DESIGN COEFFICIENTS: SDS=1.19, SD1=0.82 <br />FOUNDATION <br />1. ANY VEGETATION AND/OR DEMOLITION DEBRIS SHALL BE REMOVED AND HAULED FROM THE PROPOSED <br />GRADING AREAS PRIOR TO THE START OF GRADING OPERATIONS EXISTING VEGETATION SHALL NOT BE <br />MIXED OR DISCED INTO THE SOILS <br />2. ANY REMOVED SOILS MAY BE REUSED AS COMPACTED FIL ONCE ANY DELETERIOUS MATERIAL OR <br />OVERSIZED MATERIALS (IN EXCESS OF EIGHT INCHES) IS REMOVED. <br />3. GRADING SHALL EXTEND A MINIMUM OF SEVEN HORIZONTAL FEET OUTSIDE THE EDGES OF FOUNDATIONS <br />OR EQUIDISTANT TO THE DEPTH OF FILL PLACED, WHICHEVER IS GREATER <br />4. DUE TO ELEVATED MOISTURE LEVELS IN THE SUBSURFACE SOILS, IT IS POSSIBLE THAT WET AND/OR <br />YIELDING SOILS MAY BE ENCOUNTERED DURING SITE GRADING. AERATION OF WET SOILS AND <br />STABILIZATION INCLUDING THE USE OF GEOTEXTILE FABRIC AND GRAVEL MAY BE REQUIRED BASED ON <br />ACTUAL FIELD CONDITIONS DURING SITE GRADING <br />CONCRETE <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (F'C) OF 2,500 PSI WITH TYPE <br />V CEMENT AND MAXIMUM WATER CEMENT RATIO OF .45. NO SPECIAL INSPECTION REQUIRED IF <br />CONCRETE TRUCK MIX TICKET IS PROVIDED. <br />2. ALL REBAR REINFORCING SHALL BE ASTM A955 GRADE 60 (FY=60 KSI) <br />HDUE3HDUE3 <br />HDUE3 <br />HDUE3 <br />HDUE3 <br />HDUE3 <br />HDUE3 <br />HDUE3 <br />(E) 4" CONCRETE SLAB TO REMAIN. APPLY (N) <br />REDGARD WATERPROOFING AND CRACK <br />PREVENTION MEMBRANE TO SURFACE (ESR-1413) <br />(E) 4" CONCRETE SLAB TO REMAIN. <br />APPLY (N) REDGARD WATERPROOFING <br />AND CRACK PREVENTION MEMBRANE <br />TO SURFACE (ESR-1413) <br />(E) 4" CONCRETE <br />SLAB TO REMAIN. <br />EXISTING 12" THICKENED PERIMETER <br />EDGE FOOTING TO REMAIN WITH <br />DEPTH OF 18". VERIFY IN FIELD <br />EXISTING 12" THICKENED PERIMETER <br />EDGE FOOTING TO REMAIN WITH <br />DEPTH OF 18". VERIFY IN FIELD <br />9'X6' CONCRETE <br />LANDING, 4" THICK <br />EXISTING 12" THICKENED PERIMETER <br />EDGE FOOTING TO REMAIN WITH <br />DEPTH OF 18". VERIFY IN FIELD <br />18" <br />11 <br />S105 <br />12 <br />S105 <br />13 <br />S105 <br />14 <br />S105 <br />25 <br />S106 <br />15 <br />S10517 <br />S105 <br />16 <br />S105 <br />18 <br />S105 <br />12 <br />S105 <br />12 <br />S105 <br />HDUE3 HDUE3 <br />HDUE3 <br />52"X36" CONCRETE <br />LANDING. 4" THICK
The URL can be used to link to this page
Your browser does not support the video tag.