Laserfiche WebLink
www.hilti.com <br />Hilti PROFIS Engineering 3.0.80 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />1 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br />Tesla <br />1216 Stealth St, Livermore, CA 94551 <br /> | <br />Charging Post Anchorage - CIP-One <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />Yoo Jin Kim <br />yokim@tesla.com <br />9/26/2022 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: HIT-HY 200 V3 + HAS-R 304/316 SS 1/2 <br /> Item number: 2045003 HAS-R 316 SS 1/2"x6 1/2" (element) / 2334276 <br /> HIT-HY 200-R V3 (adhesive) <br /> Effective embedment depth: hef,act = 4.000 in. (hef,limit = - in.) <br /> Material: ASTM F 593 <br /> Evaluation Service Report: ESR-4868 <br /> Issued I Valid: 11/1/2021 | 11/1/2022 <br /> Proof: Design Method ACI 318-14 / Chem <br /> Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. <br /> Anchor plateR : lx x ly x t = 7.000 in. x 23.000 in. x 0.250 in.; (Recommended plate thickness: not calculated) <br /> Profile: no profile <br /> Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 18.000 in., Temp. short/long: 32/32 °F <br /> Installation: hammer drilled hole, Installation condition: Dry <br /> Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present <br /> edge reinforcement: none or < No. 4 bar <br />R - The anchor calculation is based on a rigid anchor plate assumption. <br />Geometry [in.] & Loading [lb, ft.lb] <br />60