My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HISTORIC - 2044 N Ross St - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Ross St
>
2044 N Ross St
>
HISTORIC - 2044 N Ross St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2026 5:00:09 AM
Creation date
6/24/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
101127114
Full Address
2044 N Ross St
Street Number
2044
Street Direction
N
Street Name
Ross
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
N <br />ED <br />am <br />0 <br />10 <br />N <br />1.0 <br />N <br />N <br />co <br />N <br />OC3 <br />CIS!U <br />\o <br />LO <br />HH <br />00 <br />00 <br />2 <br />13 <br />2 <br />2 <br />10 12 <br />AFTER CUTTING HOUSE WRAP <br />8 <br />HOLD UP HEAD FLAP and <br />TEMPORARILY TACK <br />11 <br />HEAD <br />EAD <br />EAD <br />Is- <br />8 <br />8 <br />; <br />6 <br />6 <br />5 <br />5 <br />HEAD <br />HEAD <br />HEAD <br />R.O. <br />R.O. <br />R.O. <br />LL� <br />LL, <br />Z <br />z <br />9 <br />PRESS into SEALANT z � <br />CL Q <br />CL Q <br />and TACK IN PLACE uj Q <br />0 z <br />0 z <br />0 z <br />0 z <br />4 <br />0 z <br />4 <br />0 z <br />cc <br />cc <br />cc <br />JAMB FRAMING <br />BEYOND <br />4b <br />IN <br />OUTSIDE <br />INSIDE <br />OUTSIDE <br />INSIDE <br />OUTSIDE <br />SET WINDOW FRAME with <br />SEALANT ON BACKSIDE OF <br />JAMB FRAMING <br />FLANGES, PRESS INTO PLACE <br />BEYOND <br />4b <br />PLUMB, LEVEL and SHIM <br />for ALIGNMENT, CHECK <br />DIAGONALS FOR OUT -of <br />Z LL <br />4 <br />SQUARE RACKING, and FASTEN Z <br />4 <br />Z LL <br />z <br />TO FRAMING per MANUFR <br />z <br />z Z) <br />CL Q <br />INSTRUCTIONS <br />L Q <br />L Q <br />0 z <br />0 z <br />O z <br />3 WRAP UP JAMBS <br />d- <br />14 <br />0 <br />a0c <br />=0 <br />= <br />m <br />SILL <br />SILL <br />SILL <br />R.O. rlu <br />R.O. <br />R.O. <br />5 LEAVE (3) 2" L. <br />GAPS IN BEAD <br />5 <br />with (3) 2" L. GAPS IN BEAD <br />3 WRAP SILL PAN DOWN <br />3 <br />3 <br />over HOUSE WRAP <br />SILL <br />SILL <br />SILL <br />n WRAP UP over SILL SURFACE <br />2 <br />2 <br />/ <br />13 <br />INFx <br />1 OUTSIDE <br />IN <br />1 <br />OUTSIDE <br />IN <br />1 <br />OUTSIDE <br />ROUGH OPENING <br />ROUGH OPENING <br />ROUGH OPENING <br />OUTSIDE <br />m DIM per MANUFR <br />OUTSIDE <br />m <br />DIM per MANUF'R <br />OUTSIDE <br />m DIM per MANUFR <br />Q o <br />Q o <br />Q o <br />2 WRAPAROUND <br />3 <br />2 7 <br />6 5 <br />2 13 <br />7 <br />6 5 <br />onto JAMB SURFACE <br />4b <br />3" WRAP SILL PAN <br />around JAMB <br />JAMB <br />JAMB <br />4 <br />JAMB <br />4 <br />. <br />INSIDE <br />15 <br />3 <br />INSIDE 1 <br />15 14 <br />GE OF <br />INSIDE 1 15 to JAMB SURFACE APE HOUSE P SD L BELOW <br />1ST — PREPARE HOUSE WRAP and SET SILL PA <br />2ND — SET <br />WINDOW IN <br />OPENING <br />3RD <br />FINISH <br />HEAD FLASHING <br />INTEGRATION <br />Cl <br />�, <br />� <br />SCALE: 3" = 1'-0" <br />SCALE: 3" = 1'-0" <br />O- O <br />O HEAD O O <br />11 <br />O PERIMETER OF WINDOW O <br />OPENING BENEATH <br />HOUSE WRAP <br />HOUSE WRAP at JAMBS <br />C <br />O <br />SILL <br />INSTALL HOUSE WRAP <br />HORIZ ROWS <br />2 <br />U <br />O <br />CUTTING SEQUENCE <br />HORIZ HEAD CUT <br />O <br />O2 <br />SIDE TO SIDE <br />VERT CENTER CUT <br />OLOWER <br />DIAGONAL CUTS <br />of INVERTED 'Y' <br />O <br />4O <br />UPPER DIAGONAL CUTS <br />77 <br />O <br />HOLD UP HEAD FLAP, <br />TEMPORARILY TACK <br />OFOLD <br />JAMB FLAPS BACK <br />CUT EXCESS HOUSE -WRAP <br />MIN LAP <br />SEE SPECS <br />O <br />FOLD SILL FLAP DOWN <br />CUT EXCESS HOUSE -WRAP <br />STAPLE and SEAM TAPE <br />1 HORIZ WEATHER -LAPPED <br />/ HOUSE -WRAP SEAM FIRST -CUTTING HOUSE WRAP <br />HOUSE WRAP PREP at WINDOW OPENINGS <br />PREPARED ROUGH <br />OPENING <br />READY FOR WINDOW <br />INSTALLATION <br />HOUSE WRAP at SILL <br />CONCEALED EDGE <br />of LOWER ROW <br />EXPOSED EDGE <br />of UPPER ROW <br />/O <br />HEAD <br />SILL <br />SECOND - PREPARED OPENING <br />DETAIL <br />INSIDE <br />WOOD DOOR <br />FRAME and STOP <br />WOOD THRESHOLD <br />SET ON SILL PAN in <br />CONT BEAD of <br />SEALANT then ANCHOR <br />TO SLAB with <br />EXPANSION TYPE <br />ANCHORS <br />CONIC <br />SLAB i <br />4 <br />J <br />CITY OF SANTA ANA <br />PWpning 4rgjWj*rj§bjqWncy <br />DOOR, SEE SCHEDULE and <br />ELEVATIONS I <br />n <br />FOR <br />PE <br />S <br />20 GA GALV SILL PAN <br />WRAP ENDS UP R UGH JAMBS 3" <br />SET PAN IN FULL BED MASTIC <br />PA PROFILE 1" <br />ARCHITECTURE / INTERIORS <br />SEE DETAIL 5/-- fcMAN@mto r <br />I D. <br />A D V I51 O LI OF FOX GROUP ARCHITECTS, INC. <br />INFORMATION abo t PAN <br />Date: <br />N <br />275 SOUTH GLASSELL STREET <br />TOP of <br />ORANGE, CALIFORNIA 92866 <br />Pll AR <br />TEL: 714 628-0777 <br />FAX: 714 628-0797 <br />EXTERIOR SURFACE <br />SEE SITE PLAN for <br />TYPE and ELEVATION <br />RICK FOX, ARCHITECT <br />DOOR THRESHOLD OUTSWING CAROL TINK- FOX, ARCHITECT <br />SCALE: 3" = 1'-0" ® SCALE: 3" = 1'-0" <br />SELF ADHERED FLEXIBLE <br />FLASHING - SEE SPECS <br />'J' METAL STUCCO TRIM <br />CONT BEAD SEALANT — <br />DETAIL <br />SCALE: 3" = 1'-0" <br />WALL FRAMING and PLYWOOD <br />SHEATHING <br />2 <br />Z <br />4 ll� co <br />4 I Lu <br />z Q> <br />I z _jO <br />00 w I <br />> <br />o <br />I i <br />— S S <br />COPPE R <br />STAINLESS <br />SCALE; 3" = 1'-O" <br />FASTENERS <br />FULLY -SOLDER <br />ALL JOINTS NOT <br />THE FOLLOWING KEYNOTES APPLY TO WEATHER -BARRIER INSTALLATION: <br />BROKEN FROM A <br />CONTINUOUS SHEET <br />1 <br />WALL FRAMING and SUBSTRATE ASSEMBLY, SEE DWGS and WALL LEGEND <br />2 <br />HOUSE WRAP, SEE SPECS <br />VERTICAL FACE — <br />3 <br />SILL PAN SELF-AHDHERED FLEXIBLE FLASHING, SEE SPECS <br />of CONC SLAB <br />4 <br />FLANGED WINDOW FRAME, SEE DWGS, WINDOW SCHEDULE, and SPECS <br />5 <br />CONTINUOUS BEAD OF SEALANT, PER WINDOW MANUFR SPECS <br />6 <br />FASTENERS TO ANCHOR FLANGES, TYPE and SIZE PER WINDOW MANUFR <br />7 <br />SELF -ADHERED FLEX TAPE, VERT over WINDOW JAMB FLANGES <br />8 <br />SELF -ADHERED FLEX TAPE, HORIZ over WINDOW HEAD FLANGES <br />O VERT LEG <br />VERT SEE FLR <br />�oR�ti FINISH THK <br />VIER FULLY- S D <br />ALL SEAMS <br />ISOMETRIC VIEW <br />THE FOLLOWING KEYNOTES APPLY TO THIS DETAIL ONLY: <br />9 METAL DRIP CAP, ACCROSS ENTIRE WIDTH OF WINDOW HEAD <br />10 FOLD HOUSE WRAP DOWN OVER FLEX TAPE and TACK STAPLE IN PLACE 1 FLOOR SHEATHING <br />11 "SKIP TAPE" HOUSE WRAP HEAD FLAP 2 PLYWOOD WALL SHEATHING UNDERLAYMENT OR STRUCTURAL SHEAR PANEL <br />12 TAPE OVER 45-DEGREE ANGLED HEAD CUTS IN HOUSE WRAP 3 COPPER PAN / SADDLE FLASHING, 20 OUNCE/SF (22 GA), ATTACH with <br />13 EXTERIOR FINISH, SEE DWGS, ADDITIONAL DETAILS and SPECS COPPER NAILS OR STAINLESS SCREWS. FULLY -SOLDER ALL JOINTS. <br />O FLEXIBLE FLASHING at HEAT and JAMB - SEE SPECS <br />14 CONTINUOUS BEAD OF SEALANT AFTER WINDOW IS SET <br />15 HOUSE WRAP TAPE <br />16 <br />17 <br />WINDOW INSTALLATION KEYNOTES ��� SILL PAN FLASHING at EXTERIOR DOOR <br />DUAL GLAZED WINDOW UNIT <br />SEE WINDOW SCHEDULE and <br />SPECIFICATIONS <br />2xV1 <br />STUD <br />SEE � <br />LIEGE <br />GYPS <br />DRY\.A <br />W00 <br />pCASII` <br />INTEF <br />DESI _ <br />SHIM <br />for LE <br />NOTICE REGARDING OWNERSHIP OF DOCUMENTS: <br />ALL SKETCHES, DRAWINGS AND/ OR SPECIFICATIONS PREPARED <br />FOR THIS PROJECT BY STRATOS FORM ARE AND SHALL REMAIN <br />7/8" EXTERIOR CEMENT <br />THE EXCLUSIVE PROPERTY OF STRATOS FORM WHETHER OR <br />- <br />NOT THE PROJECT FOR WHICH THEY ARE PREPARED IS <br />PLASTER SEE SPECS <br />EXECUTED. RE -USE, REPRODUCTION OR PUBLICATION OF THESE <br />DOCUMENTS BY ANY METHOD, IN WHOLE OR IN PART, IS <br />LATH OVER TWO LAYERS <br />PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM STRATOS <br />'D' <br />FORM UNAUTHORIZED USE SHALL CONSTITUTE A BREACH OF <br />OF GRADE PAPER <br />CONFIDENCE. <br />SEE SPECS <br />STRATOS FORM SHALL BE HELD HARMLESS FROM ANY AND <br />ALL CLAIMS, DAMAGES AND LOSSES WHATSOEVER <br />RESULTING FROM SUCH UNAUTHORIZED USE. ANY EXPENSES <br />INCURRED, INCLUDING COURT COSTS AND FEES, SHALL BE <br />PAYABLE UPON DEMAND. <br />T /I\ K <br />PIL D SHTG ' <br />WHERE OCCURS <br />2 x WOOD STUD WALL <br />SEE WALL LEGEND <br />GYPSUM DRYWALL <br />WOOD CASING per <br />INTERIOR DESIGNER <br />WINDOW JAMB — CASEMENT <br />SCALE: 3" = 1'-0" <br />PLYWD SHTG WHERE OCCURS <br />7/8" EXTERIOR CEMENT <br />PLASTER - SEE SPECS <br />LATH OVER TWO LAYERS OF <br />GRADE 'D' PAPER - SEE SPECS <br />EXTEND DOWN over FLEXIBLE <br />FLASHING <br />SELF -ADHERED FLEXIBLE <br />FLASHING -SEE SPECS <br />DOWN over NAILING FLANGE <br />"J" METAL STUCCO TRIM <br />CONT BEAD SEALANT <br />DUAL GLAZED WINDOW UNIT <br />SEE WINDOW SCHEDULE and <br />SPECIFICATIONS <br />SET HEAD and JAMB NAILING <br />FLANGES IN FULL BED OF <br />SEALANT, SILL FLANGE SEALANT <br />BEAD SHALL NOT BE CONT <br />WINDOW HEAD — CASEMENT <br />SCALE: 3" = 1'-0" <br />SHIM UNIT <br />for LEVEL <br />DUAL GLAZED WINDOW UNIT <br />SEE WINDOW SCHEDULE and <br />SPECIFICATIONS <br />SET HEAD and JAMB NAILING <br />FLANGES IN FULL BED OF <br />SEALANT, SILL FLANGE SEALANT <br />BEAD SHALL NOT BE CONT <br />CONT BEAD SEALANT <br />In <br />/ "J" METAL STUCCO TRIM <br />WOOD <br />CASIN <br />SELF -ADHERED FLEXIBLE <br />SILL PAN FLASHING - SEE SPECS <br />INer <br />TERIOR <br />DESIGNER <br />SILL APRON FLASHING under <br />FLEXIBLE SILL PAN FLASHING <br />GYPSUM <br />7/8" EXTERIOR CEMENT <br />DRYWALL <br />PLASTER - SEE SPECS <br />LATH OVER TWO LAYERS OF <br />GRADE 'D' PAPER - SEE SPECS <br />2 x WOOD <br />STUD WALL <br />EXTEND UP under SILL APRON <br />SEE WALL <br />FLASHING <br />LEGEND <br />—Iff <br />PLYWD SHTG WHERE OCCURS <br />WINDOW SILL <br />— CASEMENT <br />0 <br />� <br />b <br />Q <br />� <br />� <br />IT W <br />Q <br />CO <br />ccoie <br />�l <br />(may <br />a <br />° <br />z <br />�z <br />z <br />NCO <br />PROFESSIONAL SEAL <br />e1c`o <br />p+RCTI <br />o <br />No. C-19457 <br />REN.9-30-27 <br />9�F of CAS-�F�Q <br />ARCHITECTURAL <br />DETAILS <br />MILESTONES: <br />1. <br />REVISIONS: <br />A <br />SHEET <br />A5.2 <br />E <br />SCALE: NONE <br />SCALE: NONE <br />SCALE: NONE <br />SCALE: 3" = l'-O" <br />
The URL can be used to link to this page
Your browser does not support the video tag.