Laserfiche WebLink
CITY OF SANTA ANA <br />Planning dr00A1MrftA%fncy <br />m <br />co <br />I <br />N <br />I <br />0 <br />U <br />N <br />a� <br />a� <br />s <br />U <br />W <br />0 <br />0 <br />O-0 <br />N 0 <br />Lo C� <br />�dl <br />~w <br />OJ <br />d� <br />KEYNOTES <br />FI EXISTING CONCRETE AND BRICK DRIVEWAY TO REMAIN <br />Ifl EXISTING MAIN OVERHEAD UTILITY LINE TO REMAIN <br />17 ANY WORK INVOLVING WATER SERVICE/METER OR SEWER LATERAL <br />IN THE PUBLIC RIGHT-OF-WAY WILL REQUIRE A SEPARATE <br />ENCROACHMENT PERMIT. PLANS WOULD NEED TO BE SUBMITTED <br />FOR A FORMAL PLAN CHECK REVIEW THROUGH PUBLIC WORKS PRIOR <br />TO THE ISSUANCE OF AN ENCROACHMENT PERMIT. <br />LEGEND <br />Ifl EXISTING POWER FEED TO HOUSE 18 PROPERTY OWNER IS RESPONSIBLE FOR CHECKING AND VERIFYING <br />WITH THE UTILITY COMPANY FOR UTILITY/EASEMENT. 01 <br />O <br />EXISTING 6'-O'" HIGH BLOCK WALL TO REMAIN 19 A BACKFLOW DEVICE (DOUBLE CHECK VALVE) WILL NEED TO BE L��� <br />INSTALLED FOR FIRE SPRINKLERS. THE EXISTING WATER SERVICE (FROM <br />THE MAIN TO THE METER) MUST BE A MINIMUM SIZE OF 1", OTHERWISE FG <br />EXISTING 2'-9" HIGH WOOD FENCE WITH 3'-O" HIGH PILASTERS ANEW 1" SERVICE WILL NEED TO BE CONSTRUCTED IN THE PUBLIC o0 <br />TO REMAIN RIGHT-OF-WAY, WHICH WOULD REQUIRE AN ENCROACHMENT PERMIT, <br />❑6 EXISTING 5'-0" HIGH WOOD AND BLOCK FENCE TO REMAIN <br />�7 EXISTING TREE TO REMAIN - VERIFY WITH LANDSCAPE PLAN <br />❑8 EXISTING TREE TO BE REMOVED <br />9❑ EXISTING BRICK WALKWAY TO REMAIN <br />10 EXISTING CONCRETE STOOP AND STEPS TO REMAIN <br />11 PROPOSED AC UNIT ON ROOF - SEE ROOF PLAN <br />12 NEW CONCRETE WALKWAY <br />13 UTILITIES TO BE UNDERGROUND, PER SAMC SEC, 41-626 <br />14 NEW LANDSCAPING WILL MEET SAMC SEC, 41-239 AND 41-240 <br />15 LANDING WHALL NOT BE MORE THAN 1 3/4" BELOW <br />TOP OF THRESHOLD <br />16 NEW HEDGE TO SCREEN ROOF EQUIPMENT FROM THE WEST <br />EXISTING SPOT ELEVATION <br />PROPOSED SPOT ELEVATION <br />NG <br />NATURAL GRADE <br />FF <br />FINISH FLOOR <br />FG <br />FINISH GRADE <br />FL <br />FLOW LINE <br />FS <br />FINISH SURFACE <br />TB <br />TOP OF BERM <br />TC <br />TOP OF CURB <br />TG <br />TOP OF GRATE <br />TP <br />TOP OF POLE <br />TW <br />TOP OF WALL <br />TOE <br />TOE OF SLOPE <br />TOS <br />TOP OF SLOPE <br />LIP <br />LIP OF GUTTER <br />BW <br />BACK OF WALK <br />BM BENCHMARK <br />TBM TEMPORARY BENCHMARK <br />.................... <br />..................... <br />........... <br />.................. <br />PROPOSED ADDITION <br />SITE PLAN <br />SCALE; 1/8" = 1'-O" <br />0 <br />FOR PE <br />Master ID: <br />Date: <br />ARCHITECTURE / INTERIORS <br />A DIVISION OF FOX GROUP ARCHITECTS, INC. <br />275 SOUTH GLASSELL STREET <br />ORANGE, CALIFORNIA 92866 <br />TEL: 714 628-0777 <br />FAX: 714 628-0797 <br />RICK FOX, ARCHITECT <br />CAROL TINK- FOX, ARCHITECT <br />NOTICE REGARDING OWNERSHIP OF DOCUMENTS: <br />ALL SKETCHES, DRAWINGS AND/ OR SPECIFICATIONS PREPARED <br />FOR THIS PROJECT BY STRATOS FORM ARE AND SHALL REMAIN <br />THE EXCLUSIVE PROPERTY OF STRATOS FORM WHETHER OR <br />NOT THE PROJECT FOR WHICH THEY ARE PREPARED IS <br />EXECUTED. RE USE, REPRODUCTION OR PUBLICATION OF THESE <br />DOCUMENTS BY ANY METHOD, IN WHOLE OR IN PART, IS <br />PROHIBITED EXCEPT BY WRITTEN PERMISSION FROM STRATOS <br />FORM. UNAUTHORIZED USE SHALL CONSTITUTE A BREACH OF <br />CONFIDENCE, <br />STRATOS FORM SHALL BE HELD HARMLESS FROM ANY AND <br />ALL CLAIMS, DAMAGES AND LOSSES WHATSOEVER <br />RESULTING FROM SUCH UNAUTHORIZED USE. ANY EXPENSES <br />INCURRED, INCLUDING COURT COSTS AND FEES, SHALL BE <br />PAYABLE UPON DEMAND. <br />C� <br />o <br />� <br />no <br />Q <br />a <br />� <br />w <br />Q <br />m0 <br />113:w <br />CO< <br />CO <br />Ix � <br />° <br />z <br />Q <br />z <br />N( <br />PROFESSIONAL SEAL <br />�5eD AR <br />p�. T1NK`.cT�CC� <br />0 <br />No. C-19457 <br />�>. REN.9-30-27 <br />OF CA`\��Q, <br />PROPOSED <br />SITE PLAN <br />MILESTONES <br />REVISIONS <br />0 PLAN CHECK CORR <br />5/4/26 <br />A <br />0 <br />SHEET <br />Al <br />E <br />