<br />18. 1" brace to each stud and plate
<br />Floor
<br />1.Blocking between ceiling
<br />joists, rafters or trusses to top
<br />plate or other framing below
<br />3-8d common (21/2" × 0.131"); or
<br />3-10d box (3" × 0.128"); or
<br />3-3" × 0.131" nails; or
<br />3-3" 14 gage staples, 7/16" crown
<br />Each end, toenail
<br />DESCRIPTION OF BUILDING ELEMENTS
<br />2-8d common (21/2" × 0.131")
<br />2-3" × 0.131" nails
<br />2-3" 14 gage staples
<br />2-16 d common (31/2" × 0.162")
<br />3-3" × 0.131" nails
<br />3-3" 14 gage staples
<br />Blocking between rafters
<br />or truss not at the wall top
<br />plate, to rafter or truss
<br />Flat blocking to truss and
<br />web filler
<br />2.Ceiling joists to top plate
<br />16d common (31/2" × 0.162") @ 6" o.c.
<br />3" × 0.131" nails @ 6" o.c.
<br />3" × 14 gage staples @ 6" o.c
<br />3-8d common (21/2" × 0.131"); or
<br />3-10d box (3" × 0.128"); or
<br />3-3" × 0.131" nails; or
<br />3-3" 14 gage staples, 7/16" crown
<br />Each end, toenail
<br />End nail
<br />Face nail
<br />Each joist, toenail
<br />Face nail
<br />Face nail
<br />Face nail
<br />NUMBER AND TYPE OF FASTENER SPACING AND LOCATION
<br />3.Ceiling joist not attached to parallel rafter,
<br />laps over partitions (no thrust) (see
<br />Section 2308.7.3.1, Table 2308.7.3.1)
<br />4.Ceiling joist attached to parallel rafter
<br />(heel joint) (see Section 2308.7.3.1,
<br />Table 2308.7.3.1)
<br />5.Collar tie to rafter
<br />6.Rafter or roof truss to top plate
<br />(See Section 2308.7.5, Table 2308.7.5)
<br />7.Roof rafters to ridge valley or hip
<br />rafters; or roof rafter to 2-inch
<br />ridge beam
<br />8.Stud to stud (not at braced wall
<br />panels)
<br />9.Stud to stud and abutting studs at
<br />intersecting wall corners (at braced
<br />wall panels)
<br />10.Built-up header (2" to 2" header)
<br />11.Continuous header to stud
<br />3-16d common (31/2" × 0.162"); or
<br />4-10d box (3" × 0.128"); or
<br />4-3" × 0.131" nails; or
<br />4-3" 14 gage staples, 7/16" crown
<br />Per Table 2308.7.3.1
<br />3-10d common (3" × 0.148"); or
<br />4-10d box (3" × 0.128"); or
<br />4-3" × 0.131" nails; or
<br />4-3" 14 gage staples, 7/16" crown
<br />3-10 common (3" × 0.148"); or
<br />3-16d box (31/2" × 0.135"); or
<br />4-10d box (3" × 0.128"); or
<br />4-3" × 0.131 nails; or
<br />4-3" 14 gage staples, 7/16" crown
<br />2-16d common (31/2" × 0.162"); or
<br />3-10d box (3" × 0.128"); or
<br />3-3" × 0.131" nails; or
<br />3-3" 14 gage staples, 7/16" crown; or
<br />3-10d common (3" × 0.148"); or
<br />4-16d box (31/2" × 0.135"); or
<br />4-10d box (3" × 0.128"); or
<br />4-3" × 0.131" nails; or
<br />4-3" 14 gage staples, 7/16" crown
<br />Wall
<br />16d common (31/2" × 0.162");
<br />10d box (3" × 0.128"); or
<br />3" × 0.131" nails; or
<br />3-3" 14 gage staples, 7/16" crown
<br />16d common (31/2" × 0.162"); or
<br />16d box (31/2" × 0.135"); or
<br />3" × 0.131" nails; or 3-3" 14 gage
<br />staples, 7/16" crown
<br />16d common (31/2" × 0.162"); or
<br />16d box (31/2" × 0.135")
<br />4-8d common (21/2" × 0.131"); or
<br />4-10d box (3" × 0.128")
<br />Toenailc
<br />End nail
<br />Toenail
<br />24" o.c. face nail
<br />16" o.c. face nail
<br />16" o.c. face nail
<br />12" o.c. face nail
<br />12" o.c. face nail
<br />16" o.c. each edge, face nail
<br />12" o.c. each edge, face nail
<br />Toenail
<br />Connections for wood members shall be designed in accordance with the appropriate
<br />methodology in Section 2302.1. The number and size of fasteners connecting wood members
<br />shall be not less than that set forth in Table 2304.10.2.
<br />2304.10.2 Fastener Requirements
<br />(TABLE 2304.10.2) FASTENING SCHEDULE
<br />12.Top plate to top plate
<br />16d common (31/2" × 0.162"); or
<br />10d box (3" × 0.128"); or
<br />3" × 0.131" nails; or
<br />3" 14 gage staples, 7/16" crown
<br />16" o.c. face nail
<br />12" o.c. face nail
<br />13.Top plate to top plate, at end joints
<br />8-16d common (31/2" × 0.162"); or
<br />12-10d box (3" × 0.128"); or
<br />12-3" × 0.131" nails; or
<br />12-3" 14 gage staples, 7/16" crown
<br />Each side of end joint, face
<br />nail (minimum 24" lap splice
<br />length each side of end joint)
<br />14.Bottom plate to joist, rim joist, band joist or
<br />blocking (not at braced wall panels)
<br />16d common (31/2" × 0.162"); or
<br />16d box (31/2" × 0.135"); or
<br />3" × 0.131" nails; or
<br />3" 14 gage staples, 7/16" crown
<br />16" o.c. face nail
<br />12" o.c. face nail
<br />15.Bottom plate to joist, rim joist, band joist
<br />or blocking at braced wall panels
<br />2-16d common (31/2" × 0.162"); or
<br />3-16d box (31/2" × 0.135"); or
<br />4-3" × 0.131" nails; or
<br />4-3" 14 gage staples, 7/16" crown
<br />16" o.c. face nail
<br />17.Top plates, laps at corners and
<br />intersections
<br />19.1" × 6" sheathing to each bearing
<br />20.1" × 8" and wider sheathing to each bearing
<br />2-8d common (21/2" × 0.131"); or
<br />2-10d box (3" × 0.128"); or
<br />2-3" × 0.131" nails; or
<br />2-3" 14 gage staples, 7/16" crown
<br />2-8d common (21/2" × 0.131"); or
<br />2-10d box (3" × 0.128")
<br />3-8d common (21/2" × 0.131"); or
<br />3-10d box (3" × 0.128")
<br />Face nail
<br />4-8d common (21/2" × 0.131"); or
<br />4-10d box (3" × 0.128"); or
<br />4-3" × 0.131" nails; or
<br />4-3" 14 gage staples, 7/16" crown; or
<br />Toenail
<br />End nail
<br />2-16d common (31/2" × 0.162"); or
<br />3-10d box (3" × 0.128"); or
<br />3-3" × 0.131" nails; or
<br />3-3" 14 gage staples, 7/16" crown
<br />16.Stud to top or bottom plate
<br />2-16d common (31/2" × 0.162"); or
<br />3-10d box (3" × 0.128"); or
<br />3-3" × 0.131" nails; or
<br />3-3" 14 gage staples, 7/16" crown
<br />Face nail
<br />Face nail
<br />Face nail
<br />21.Joist to sill, top plate, or girder
<br />3-8d common (21/2" × 0.131"); or floor
<br />3-10d box (3" × 0.128"); or
<br />3-3" × 0.131" nails; or
<br />3-3" 14 gage staples, 7/16" crown
<br />22.Rim joist, band joist, or blocking to top
<br />plate, sill or other framing below
<br />8d common (21/2" × 0.131"); or
<br />10d box (3" × 0.128"); or
<br />3" × 0.131" nails; or
<br />3" 14 gage staples, 7/16" crown
<br />6" o.c., toenail
<br />Toenail
<br />23.1" × 6" subfloor or less to each joist 2-8d common (21/2" × 0.131"); or
<br />2-10d box (3" × 0.128")
<br />2-16d common (31/2" × 0.162")24.2" subfloor to joist or girder
<br />25.2" planks (plank & beam — floor & roof)2-16d common (31/2" × 0.162")Each bearing, face nail
<br />20d common (4" × 0.192")
<br />26.Built-up girders and beams, 2" lumber
<br />layers
<br />10d box (3" × 0.128"); or
<br />3" × 0.131" nails; or
<br />3" 14 gage staples, 7/16" crown
<br />24" o.c. face nail at top and
<br />bottom staggered on opposite
<br />sides
<br />And:
<br />2-20d common (4" × 0.192"); or
<br />3-10d box (3" × 0.128"); or
<br />3-3" × 0.131" nails; or
<br />3-3" 14 gage staples, 7/16" crown
<br />Ends and at each
<br />splice, face nail
<br />27.Ledger strip supporting joists or
<br />rafters
<br />3-16d common (31/2" × 0.162"); or
<br />4-10d box (3" × 0.128"); or
<br />4-3" × 0.131" nails; or
<br />4-3" 14 gage staples, 7/16" crown
<br />Each joist or rafter, face nail
<br />32" o.c., face nail at top and
<br />bottom staggered on opposite
<br />sides
<br />Face nail
<br />Face nail
<br />28.Joist to band joist or rim joist
<br />3-16d common (31/2" × 0.162"); or
<br />4-10d box (3" × 0.128"); or
<br />4-3" × 0.131" nails; or
<br />4-3" 14 gage staples, 7/16" crown
<br />Each end, toenail
<br />2-8d common (21/2" × 0.131"); or
<br />2-10d box (3" × 0.128"); or
<br />2-3" × 0.131" nails; or
<br />2-3" 14 gage staples, 7/16" crown
<br />29.Bridging or blocking to joist, rafter or truss
<br />End nail