My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
888 N Main St_1 - Soils Report
PBA
>
Building
>
Soils Reports
>
M
>
Main St
>
888 N Main St
>
888 N Main St_1 - Soils Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2022 11:07:09 AM
Creation date
1/13/2022 11:07:04 AM
Metadata
Fields
Template:
Soils Report
Full Address
888 N Main St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
3033 S. Harbor Blvd. <br />Santa Ana, CA 92704 <br />Rhone: 714-427-0501 <br />Fax: 714-427-0502 <br />www.inspection-resources.com <br />#dIM INSPECTION <br />I I RESOURCES <br />allp/lis In No••destructl¥/ V//tin' <br />GROUND PENETRATING RADAR TESTING FIELD REPORT- Concrete <br />Project Name <br />888 N. Main <br />Address Where Testing Occurred <br />888 N. Main, St, Santa Ana, CA <br />Contractor or Person Requesting Testing <br />Pennit #:Jurisdiction: <br />Information Purposes Only <br />Name of Contact Person at Site <br />Date <br />06-29 thru 07-03-18 <br />IRC Project #: <br />1204-12480 <br />Technician(s)GPR Equipment Mfg and Model Number <br />Ryan Barkley Maia CX 11 <br />List Other Equipment Utilized (e.g. electromagnetic device) Mfg and Model <br />Elcometer <br />Type of Structure (e.g. multi story hotel; parking facility)General Site Conditions <br />Multi story building Free from obstructions <br />Technician Comments: <br />Excel file contains further reinforcing details <br />Antenna Frequency <br />1.6 GHz <br />Test Locations This Date <br />25 locations <br />Project Notes: <br />• Contractor is responsible for maintaining all lines drawn (test results) on concrete and masonry <br />• Scans conducted near walls, ceilings or borders will result in a 3" dead zone (area that cannot be scanned). <br />• Targets located with GPR aremarked directly on scanning surface using BLACK, BLUE ORGREEN colormarkers. <br />• Uve 50/60 Hz Electrical targets are marked in RED color markers or spray paint. <br />• Un-energized / low voltage wires / data cables in plastic conduit cannot be easily detected with conventional GPR/Electromagnetic methods. <br />Client understands that detection using GPR/Electromagnetic methods are pe,formed on a best effort basis and results are not guaranteed. If <br />GPR method proves to be having difficulty in resolving critical areas, X.Ray method is recommended. <br />• If GPR target lines physically marked on test area(s) by the technician are In conflict with the specified layout for saw cut, drilling and/or <br />coring operations, it is recommended that written approval is obtained from authorized client representative prior to commencement of any <br />saw cut, drilling and/or corIng operations. <br />• Client understands that GPR interpretations do not differentiate between rebar, conduit and/or PT cable. If client is requesting that these <br />elements must be positively identified, then X-Ray method shall be required. <br />• Rough surface conditions, obstructions in immediate GPR scanning area. high density wire mesh, weather proofing. or alr gaps between <br />structural concrete/masonry layers may impede or prohibit radar penetration. If such condition(s) exists alternative methods may be <br />necessary. <br />• If rebar size estimation is performed, results are subject to a tolerance of +/- 1 bar diameter. <br />• It is recommended that client stays 2" away from all targets marked. <br />• Signature below verifies technician(s) time onsite and services performed as per customer request <br />SEE ATTACHED PHOTOGRAPHS ON NEXT PAGE FOR DETAILS <br />Time In: 0730 Time Out: 1530 Total (Hrs): 24 Travel (Hrs): <br />Regular Time: 24 1.5X:2X: <br />t.>25- <br />Technician'* Signature Client Signatore <br />Continued on Next Page <br />Test Results provided by Inspection Resources, co are given in good faith and are usually accurate. However, in the unlikely event that such information proves to be <br />inaccurate, the extent of liability assumed by Inspection Resources, Co., if any, is limited to the amount billed for labor and materials on the day that information provided was <br />alleged to have been inaccurate. Please Note: Certain low-density materials such as PVC, -smurf tube' and plastics in general may not be located accurately, if at 81], using <br />any inspection method. <br />C"Y
The URL can be used to link to this page
Your browser does not support the video tag.