Loading...
HomeMy WebLinkAbout10192746 - Permittl city of Santa Ana 20 Civic Center Plaza (M-19), Santa Ana, CA 92702 2' 7 Building Permil Counter: (714) 647-5800 lnspection Requests: (714\ 667-2738 lnspector Section: (714) 647-5853 Permit #: 10192746 Pin #: 64526 a ProjectAddress:711 S Kilson Dr Assessor's Parcel 0'r 1-094-03 Lot: 8 Bldg: Address Range Suite Range: Zoning: Rl $Tracl 608 Historic No Building Use: Job Type: Nature of Work: Existing Bldg. & Use: Proposed Use: Single Family Dwelling Solar Solar Sfd w/d6t garage R-3 VB cBc 2016 x-0602320276J 1st FL Area: 2nd FL Area: Other Areas: Garage Area Totall Patio: T.l.Area: Yards Req'd: Valuation: i6,000.00 Description of Work: lnstall new '1.68 kw roof mounted solar PV system (6 panels) Per PV checklist Planning Conditions: Owner: Address Phone: Tenant Richard E Stephens 711 S Kilson Dr Santa Ana, cA 927016043 (714) 543-s795 Contracior: Zero Energy Co Address: 10500 Shoemaker Avenue, * Santa Fe Sprlngs, CA 90670 Phone: (626) 701.3180 State Lic #: 953417 Lic Type: B Bus. Lic #: 347102 Workers' Compensation lnsurance: Carrier; Great Oivide lnsurance Company Policy #: WCA2014597 Expires: 0411412017 J.S.Byon Structural Engineerir Jin S Byon 13601 E Whitlier Blvd, Suite 205 Whittier, CA 90605 (626) 991.7354 r, 45122 Engineer iD: LRoSA1of 1019? 7 {6 9:i3 All t5[rl .nnPhone: License #: Phone: License #: Architecl / Desiqner: Address: gu i ld ins rrl I 16002- il6trlr:[-rU-gl de SIds Revol,r ing r.r1 I 16t-fl:r2- 51612t:rurt- 1(:[ Chec]r 0l s6l0 $5(t(r. r:fl:r $ ,. r,I:r $:;r:r1 . r:rtl Planning Approval By: Plan Checked By: Permit lssued By: NPDES Insp. Req'd: PWA lnsp. Req'd: Planning lnsp. Req'd: Landscaping lnsp. Req'd Date: Date: Oale: 0112112017 Subject to Field: Misc. Receipt Misc. Receipt Misc Receipt $500.00 $1.00 $0.00 07776002 51501 Permit Fee 07776002 57672 Bldg. Stds. Revolving 07776002 51600 General Plan Update Fire lnsp. Req'd: Police lnsp. Req'd Flood Zone Cerl. Req'd; No Ot 116002 51601 Every pennit issued sholl become invalid unless the wo* on the site authoized by such permit is commencad within 180 days afret its issuance,ot il the wot* aulhoized on the site by such pemit is suspended or abandoned for a peiod of180 days after the time the wo* is commencod . lnspector MID#: 2017-135702 No No No No No No Account#Total 01 't 16002 51612 $500 00 $1.00 Fee Total: Paid to Date: Balance Due: $501.00 $0.00 $501 .00 Unit Block: NA Occupancy: Constr Type: Code: Flood Zone: # of Stories: Address: zunisa, Attissa KL' SITE.WORK DATE,i'd/stG.COMMENTS ollNlrR BUrr,Dt:R Dul,( ARAI l(rN Ihd.l'!ammuqtnFuh)nrFjurtrdIm.\mFaRnnrh.(i!rfr1o^lEdEln\hrrh(rdrkNin!re&rls<70!ll Ausio6s ind Proa6n)n cotl.) An) (ily !r (,'unrr trhich rqui6 r rEnnl r,,.on{'rr. rlr{. trtrr,o\.. &rNl'\h.' rq.n uy 3rtudu(Frnh t iram., ik rqri6rh.q'plai t fff ruch r-rir L' ika riri.l{ddhr rhd lEordrFhriFal putrd ro rh. Fo\6ionr uf rh. ( onrikrn s Li...e,.l Ii\ ((16n( q, (inMr.n(in* *[h se(it!, ?lixr .f l,n 'sinr I oi rlk lnuind &d EorBh.. ( od.) or rhd rEor$c n crorti rhd.r'o'nind rlr hra ntr rh. ilkldl.r.i'rrirr n\ \ir'Llrin,.rsNrntr rlrrl5 byey rpplcad tu a Fn ruhrerrrh..tr|)lronrhr.chilp.n.lryolno(nu.rh6nfi\el,i.tlAl(n,rln\rtrrir) 1.6o$kofrh.F.trdr.orn)(nplo)c\rh\arLrsrh.trrnccomEns knr.\ill ,drs,,Id nkenrtr(rDl inldrlol or oitccd for slc(S( 7044,I]ui'rNsnd t\oliatbN ('rds lh. (nd'.rkr s l i(6& l.d\ d,'6n lhl'til! l,' trsnsof rh.F F! \h)tr lorii{r,r6tlEur-on$h'd6*iso'rhnnsrladrhokl,orrl .url,Iso.hso\noll'r,\!a-. foldRirldrchi'nrnordndin.'rnir.rLrldolldqlftsklLlx\rc\.l.rlrhnltliruo'rtx\.lkiric!'l.l(nhi L{.q oacGr?tri{. rh.()$F ltuikj. rill h,r!ilE h df,fForn$ thd h.or {f,Jrl r{ h .lor( Fo\. kFqrrr\ lin rlxtintr4of l,6osffi ofrh! t otdy. tun.r(lGi\.b.onr.dinr \(h ltanB, (.nrltrloF h con$rc' rh. trq8i (s$ Torr.ltr'ns &d fttrkrs ( od. Ih.(onrrcrorr I ic.nl.l n\ do- (n !ml! rr Mornr olr,.tir\ ntu h'il,lrN irnrrr\snucrn. ,nd trri, coolmds [r tu.h roj(lr $ irh n (i,ftBb( n lrdrs! rn,ntr n)rh.(irntri.rr's l ($sc lis) I !n.(n utuLr S(rdr l).1. Oir.r l!!B$:Bfll,lr!ttu$ ll!.1!u;!.L^ts{llo! I ho.l,) iflnnun(ls lErtrhtoltEl,trrrrcoirh.n,l[N,nt .r'h8rkn lhn\.elNlln{'nra'nr(Fl,[irr.oI(onhrn,S.lfln('.tutrort6\'rotmlii,n.a3lro\(l.nnrl'\\c..n!{rrr()ofrh. I ahtr (irdc. tr rh. p6tunrtr.c ollhr \o'I ftn \h'ch lhc l]otr trn\'(d rhr rfrLlLr $h'rh(lnsJEnr '\ 'rnhl \t\\o,ldi ftltrl(\rro['.nr I rr\1 ' ,-r:_2f t-> -,.2- Pdir\ Nun,rs:- ,--<a 7at15C'7 -'j r'\ri'c .+. tL< ll Ic.nilvrhar inr[.pntuinin.. lrh. $orl nn $hi.hrhn rEnrir ir iBud. I rhrll Dor r r n\rr)Brso irtrn) nmkr e a lo 6L.nE shr.cr h tlF \ $tG' ompqRanr b\ ! .a ('ilir!,mtr. ind i$'a rt 'rl rhull lno r. sulr.rt r,rlE N*sJ $nrp.0sriotr |]ro\i.ion! olsccrnr lT0orfrhe lihtr ( (i..lrlull,linrlrtrirh cont'l\ \ irI rlk'k l'xNiri'nn W 7t ilNlN(;: F ilur. ro RUr. tro 6. anqn$ritn N\ d!. . unh{ tu|. .'kt rldl srhF-l M dnl'Lt\q hr d nnn l tir{li! ..d .nil find up ld.N h ndreJ rkru$nJ &n[R (lllnl.lnx)1. in {Jdni,,n k' rlr (.{ ol( nrEnslidr, ,ltnra[.s nr rro\nl.! fo.lh. vrrir ur76.r,h.l rtn riii. dradralnn6 itar,//'-> '?tht: -.t- 7C1- t? rPPlda: ,< . -..\ _ _lt(};rsEDr!)!-raa(lllB -'- DloJnallo! I h6.1,,.m"n ud.r Frh) oarErju') rhd INn l'(EJ unj.r F.Li$'i ot( l[ d',l.ontr,Eu'trs \insNr{'irxxrroIl,nnion l of rh.lru3nN rnd Pn,ldhN(trd.. Md me lir6k ir in tul|(trc..rklerli(r ..,,,..",". ;)* E:;', ( {,\stRl( I t()\ MDr\(; !Grl! l ir\'.(l(sn rri,!-. (il I I ]trPl't( aN I tr[('t-{R (t l(,N I hsin aflnrondd rmri) olFjo') .E olrh. nnLN i'rr J&ltr,.ri(tr'\ t). hlirio.lt6nli'ash.!lo3 Noifi.attrn li.ddrl R.ttrlirn,nsl t l.lo.l'n 6) Rqtutrd I dr. orNd'li.irr l.dr'l\rlr rlr lcJ.', 'rrtrltrr($rN \l[ri\r*n\'.n,r,r,niJfr](,1,.(,rlr.t,..r '\'*,!{ '. "^-.-v.". -\f'nrrcinr.r \rc{ \iEnN'trry---r- - -- r- n . < !-t t7/ lcrnnkr' trsn,c, rrr ,r: /, **,.,. 3_- .: .^ ( Set Backs Forms/Steel/Holdowns Erection Pads UFER Ground SLAB Floor Subf loorA/enUl nsulation Roof Sheathing Shear Wall Framing lnsulation/Energy Drywall Ext./lnt. Lath Brown Coat Mason tY Pool Fence T-Bar Handicap Req Deputy Final Report Engineer Final Report Flood Zone Certif FINAL kllib+tNilt{1q Certificate of Occu n Notes, Remarks, Etc BUILDING- INSPECTOR RECORD I I I I I I I I *,,SANTA NA Itt\Ti0 IBI|IIJT|O rcNl' Planning & Buihling Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (Ml9) Santa Ana, CA 92702 (714) 647-s800 www,santa-ana.org laFqErtlFrEEEItrr.srin-.::ri-Tt..r:-i,.;: _;=:-;;1-::.:.,::.tI:ir@ soL-01 cBC 2013 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMTLY RESTDENCES Onty lnstructions: The Iicensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 1 1 " x '17" size. If answerinq NO to anv of the ouesti ons, plan check shall be reouired. Proj ect Address: .71 \ 3 \ee- L-s,o ^) RESIDENT!AL PHOTOVOLTAIC CHECKLIST Contractor Company Name: Contractor License Number: YES NO 1. trItr "FA 3 qtr 4 EB 5. E}D Nl ?szt1 t1 Are the following applicable to the proposed project? Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.1 1 of the California Fire Code, and is lhis shown on the roof plan? Will the PV system be installed on a roof having only one roofing layer with no overlays? Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? Will the PV system weigh maximum 4 pounds per square feet or less? Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be installed with a space of 2" minimum to 10" maximum between the underside of modules and the surface of the roof? Will the PV system be installed without using any ballast system or counter-weight system? Will the anchors be installed with a maximum horizontat anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Will the minimum 5/16'' lag screws be installed with a minimum of 2-112inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project spe ciflc site plan, PV layout, anchorage spacing, anchorage details and man r,S sup ation.) I certify under penalty of perjury under the laws of the S o tiforn true: Print Name: WP?*v L [+-s Signature Date: 6. Ertr 7. El,,O 8 Etr 9 Etr 10 E}E phone Number: e22 b) 70 I - 3\tL) Email Address: 7u *t,=n \.:) tl Lo/\ Rev 11/19/2015 Ll l> .-,,SANTA NA tLlllNC &BIIIDNC tcil0 Planning & Building Agency Building Safety 0ivision 20 Civic Center Plaza P.O. Box 1988 (M-'19) Santa Ana, CA92702 (714) 647-s800 www.sanla-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST sol-01 cBc 2013 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only lnstructions: The licensed contractor of record shall complete all sections, answer the len questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11" x 17' size. lf answerinq NO to anv of the q uestions. olan check shall be required. Project Address:1tt a. lreu-sozJ -D rz- Contractor Company Name: Contractor License Number: Zeuc, F'N€u4 7 ?<3t'1 t1 a7- YES NO 1. tr} tr 2FA 3, EItr 4 Eltr 5. Eltr 6 E]tr 7 El.E 8 ETEI s. da Are the following applicable to the proposed project? Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? Will the PV system be installed on a roof having only one roofing layer with no overlays? Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? Will the PV system weigh maximum 4 pounds per square feet or less? Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be installed with a space of 2" minimum to '10" maximum between the underside of modules and the surface of the roof? Will lhe PV system be installed without using any ballast system or counter-weight system? Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Will the minimum 5/16" lag screws be installed with a minimum ol2-112 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the structural pages of the plans stamped and signed by a California10 E}E licensed professional engineer? (including project speci fic site plan, PV layoul, anchorage spacing, anchorage details and man r's su pp tion.) I certify under penalty of perjury under the laws of the Sta lifo rn true: Print Name: WP?*v L ll*^, sc,J Signature phone Number: Ub>7o I -3\8D Date: 4 l= 't Email Address '7c, nn>r-.-nt€Zeuo @ 7 ove I Rev: 11/19/2015