Loading...
HomeMy WebLinkAbout20164593 - Permit (2)City of Santa Ana Permit Counter: (714) 647-5800 20 Civic Center Plaza (M-19), Santa Ana, CA92702 Electrical lnspectaon Requeslsr (714\ 667-2738 lnspector Section: (714) 647-5853 Project Address: 1125 W River Ln Unit: Block: NA Bldg: Tract: 1357 Address Range: Historic: No Suite Range: Zoning: Rl b? Assessor'sParcel: 001-137-24 Lot POR 8 & POR 9 Owner: Address: Patricia Boa 'l125 W. River Lane Santa Ana, CA 92706 Fee Type Amount Qrr Fee Tenant Name: Conlractor Address: SolarCity Corporation l83l Ritchey St Santa Ana, CA 92705 (702) 785-2998Phone State Lic #: 888104 Lic Type: B, A, C-10, C.20, C46 Bus. Lic #: 321401 Workers' Compensation lnsurance:Carrier: Zurich Policy #: WC0182018 Expires: 1013112018 Single Family Dwelling Solar Solar R-3, U VB cEc 2016 Notes. lnslall new l'1.7 kry roof mounted solar PV system. Planning Conditions Planning Approval By Plan Checked By: Permit lssued By: Subject to Field: Building Permit #: Chavez, Dave Oate: Date: Date:12t14t2017 Account# Misc. Receipt: Misc. Receipt: Misc. Receipt: Total .<2c Every parmil issued shall becgme invalid unless lhe worr( on lhe silo aulhotized by such pomil is cornrnenced within 180 days aftet ils issuance. or iflhe wo* aothoized on lhe sile by such pemil is suspended ot abandoned for a perid ol 180 days aftet the tirne the wo is comfiencod. $0.00 90.00 $0.00 lnspector MtD# 2017-139902 Fee Tolal. Paid to Date: Balance Due Permit #: 20{64593 Pin #: 17E7E Phone . Suilding Use: , Job Type: Nature of Work Occupancy: Constr Type Code: ELECTRICAL.INSPECTOR RECORD DATE COMMENTS (,WNEX BUILDER DELCAf,ATION I lE.et y .lrtrn ud.r rErhy or p.4!r, !h, I rn .r.q{ fin rrE (ndhlort La.e Lr* fd rlx folbuina Elon 15( tul l t Buri*( a,rd &of.*io. (ii.) An, C y or Cou y lhth r.1!iEr r tffii ro Nisrud- .116. in{,mE. dcmlnh o, rFtr dt lrMr!r., ridro irr isum. ds, Equircs rtE.ppliud tu seh Fmir h fik. siSEd ild.nEnl th.r h.or $. n li..n$d Pu^u.nl ro rlI rmvnhn\ .r r,t Gntrroi( I..i.€rt Lr lorykr 9. Comrrins *irh s<rrr ]ul) ol DirFion I ol rn aunfts aid Ptua.sri,.t CdL) or rh.t lE r sh. n .rcmrl rlEEfnd !.d rlE t rir n, dE .lr.8.d .r..i9rhn An, ltbrrh 6t 5d$. 703 1 J hl .nt rp!,lr.trt ror. Frrrir$bFl(th. rl'Pli.lnr l{, !cirilr.nixyornur m,rcthln fiv. hundrddolhr ($5{x)) -1, s\ u*E otrtF FoFdl, or ny.,r?hye( *'nh uas.r ar rlri {'k.onltndhn. hll& rrt $ot !d rlE ture is t{ inl.fil.n or olIer.d r(tr $L (S(.7(r+{. ttlsiftl\ md Pnntsion\ Cud. Th. ( onlro.tor'r t-iccns ljs do.s nor dr,ply x, un ork. rf rlE Fr'rEny *,r llitl or nlln's trEcr .rd *rr d(6 srh q,t himElt or lE*lf or rllsoSh hi( m lE ovr .@k,!t<. pmviLd rhd rsh rrproHEdt @ n{ ncnLd d otu lq s! lt lb$68. rlE ttriunq d iqr'mtn n $B rihin m Fr ofort't rhn. rh. ()w*r Borlkr *rll hlr rhc hd.n ol Jn'v!n3 thrl lE or sh. dil tui lxrld or infn)E rh.IrlFny for rlr pu4r,t ol -1. fi o*m. of rlE fmrrdt, am.r.lu{vcly c. rrlins lirh li.cn{d codndonro.nNul rlE I'FFi (Sd 7041. Bhift\1 rnl Pn,fsrinCidc'thdC.ikj.r.lsLi..nrclrwd..!.orapplyt'rnowncrofpn,Frlywtu,huildsotinprovdrh.r.on. .nd who curtrr ftr rr-h FnFrt sirh e (o dndtr licn.d l[6unt !, rlE Conrrld r liiR Le) I ror(\ft! trrLlrr S\!,,' !OBf, TN.:(TME!TAITOJ! DECIdIAIIA! I h.ichy lffirm uRk' p.rlrt ur tdrrtrt or otrh.ldbsmB d.rlr.rr,nt Ihrvcmd*rllnEinruir!Ccnii.srcofCon{nrrosulflnruEritr*odc..mp!n\srion.,rti&vid.i(trtyS..rion3?rx)ulrhc lrtrr (lxt, ror rh. FrLrnlnc of llr r'o* f({ shth rh. Fnn n trsd $u"c ana ",tr,urnrrin "*I rh. xrr rin rhxhrhii mrtul ,",.lN-\^flt kcrs con,p.n\"rnn rnsxrdtu., as E( i! n\krl l\rt wollc^ . nIEnsri,)n tuircd I'y S.(lion.l7(n of rh. I irNrk..'c crri.r arl Frky nu iborCnd.. forln pc,nnnlN. ot *,,*rn,"*. WC-fl?? U pt ,rl( -l ccnily rh,r in rhc p.rr.tiMnc. ol th. *od rrn which rhh Frnir is ir\u.d, I shtll ftn.mPl.y.ny l.m'n in tny m!n*r {r s lo tE$m .uhFl ln llE enrt6'or{Inqriri b$r.f C.litu..n, lxl .Xr rh, if I rlbuld h.t m ruhFl lo rlt F.t6i oqrn{ti,n pmrii,E or S.<bn l7(f,) of rh. lrho. CGL. I rhll. lr hsnh miply tnh tbt PmvtioN I{ARNING: FliluE h suE *dk6' mtrFN.li'n i'wr+! i. lnbwful. ..d sh.ll iubrdr e .rlploF ro siniMl Fmhaa rn .ivil rik. up ro or hudt d lhousd dolt,i (!loo.Cxt)r. in .ddni,n ki th. @n oa NtqEturion, drf!.s tr FoviH ro. llI ,,.,.,pLr{ lnh{ ( "dc.lnr.hr rRlrnfnf,v'\[a DPCIJSAIIQ! I lEEby .,rm lndcr Fndry or FJUry ihI I .m lirn!.d unLr FNn,'n or Chq,rn I ldrmEi.8 yilh S.clinn 7l{O I .I Qit itiln .r ol tlE BuriE( .rn PrDr.(hnr Cod.. &d my ltd* t in rull roN !i .lTEl ,.."..,,,.e4.&b ,,* \r1t{ ta "-*r.*.m 4 Ia$UATIjIIQNIEIDIIG.ACEBCX I t Ebt rrrr !nL, ltclry or,Errlrt rhsl ttcE is a ondrudion bnrinS r&ry for llr Frfolr'uc of rh. wrt lor qfiah lhir Fml h ir.u.rl rsc .!0s7.civ c l a.tfut tiLIlgJBAIllJ! I hdrt:rfimu,rld I'cn,ht,'r Frrurl ue of rh. n)lhuot d(larxtnni I)cnrniii,)n Pcnrr\ Ashcio\ Nor iur(nr Fcdcrnl Rc3!!{i(r( r'rIh ]o. l'rn6) -Rqur.i lrn.r of M{,frdi,. [ffi,#ffi rl,rrulartrrN r! ior r\tr{'\ krnf\rl ' mr rnt,li.rht n, rhN nn,}(r rhrrnllr)rkr:uil !rr. rhrrrlf,rh*. nr,tr lrrtr{ ^ cotr..r I rsrd r,.onpl, rrh lll Ci'r{nd Counry h'\ Cny and Couiry t' crlc' lllr,n rh.Itrn!n,l,tr l(1tr,!.f nr,u!1trr, xtrrl YX rurhorrc r.nrc\ctrrdnc\ ol I ..P{ \-4 Lr3 Site-Work Underground Pole Bases Liqht Standards Spas, Pool, Fountains Siqns (monument) Life Satety /Low Voltage Fire Alarm / Dampers Communications Cable Buildinq Under Slab i Floor Bondinq / Groundinq / UFER Transformers Torqueing Sub-Panels Boof Top Equipment Factory Wired Unit Walls (Conduit) Walls (Rough) Ceilings (Hard & Sotfit Rouoh Ceilinqs (T-Bar RouOh) Meter Release Rouqh Service ltrleter FINAL t\d\rtr I \rl#r\\ Notes, Remarks, Etc -+ APPROVALS ID/SIG. Air Conditioners cn ('tr5+< .ac{ f-a-dcUoc-i4a-c oc{gcrl r </ ; o -- \ U -J.s o) o E - :. E -L U .\ l OJ x o= u- - : uJ * ; , , " .: PE = E 5 9 -; i ' - o : r" r -C Y C L = b , ; c -- H -: \ - 9: r o i- o 0J ( ) : - ! : - c ' - r 9U : ' S i l P r -o J ' = d > - OE E tr f 6 :; : : 6 -. B / E o_ !O , f E g #, ? : r E E- ur : I : !- ? r y = tr (E J j : q) 6: 6 3 = E Y- u l u - d: d 2 !r 0r : E€ i N 5 E g: 3 = o, B E- ' - ^ o . r c c li o r q ' ) r o r q d =/ 1 ;: l = o -. O- r, ^ a) € t Y. I o E !z ( . 0 r r s . ! E or EE >. 5 c$ o 6 I* ; - + i H -0 . ) - 0, lE i J Y; rE ^- : . 6 (J - - o- i -o ". o, m . bn * .t l ) rD -' l c: . = r g - r t o =t r i r l E t >i - ( n p u L ( , Y dr ^: n U L ; q l, = Q .. i r; x ? , ^ = . Y _ o, d: : EE c, ! o- ( u 2 C - EE = t r ; o- = >, o c Y= a r E - Y ai q q X; F L ! J r, j F E = ! ^E L - - @ +> , o t: / ) <q , ) E E '" > . 9 o O. ! oJ ! (, ) co u= E lr -- : ! r E O ) ; o (4 ! ! ,, Eo t i 15 i. ^ >, _ ll ;; . e o E o , Uo , l q o J - 'd o . : : E 6 E >, J4 = co d = . : = ;- t r 9 > . <t l E i c ia E s : : o! ^ o J i , j . ! !l l . . , ! / ' = O i ; zLJ JFL/ , ).> *l= t/ ) (r > cu Z Xd \J L_ dl n L,o= .. < .J t) uZ .- < 2. , F tr JFolr Ja-xIJ J I EXPEDITED PERMIT PROCESS FOR SMALL.SCALE PV SYSTEMS STANDARD STRING SYSTEM The information in this guideline is intended to help local jurisdict ions and conlraclors identity when PV syslem inslallarions are simple, needing only a basic review and when an installation is more complex. ll is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple crileria. resolulion sleps have been suggested to provide as a path to permit approval Requireil Information fot Perinit : L Site plan showing location of ma]or components on the property. This drawing need not be exactly lo scale, but it should represent relative location oI components at site (see supplied example site plan). PV arrays on dwellings with a 3'perimeter space at ridge and sides may not need seParate nre service review. 2. Electrical diagram showing PV array configuration. wiring system. overcurrenl protection, Invertet disconnecls. required signs, and ac conneclion to building (see suPPlied standard eleclrical diagram). 3 Specihcarion sheers and insralla(ion manuals (if available) lor all manufactured components including. but not limired ro. PV modules, inverter(s). combiner box, disconnects. and mounting sysrem. Step 1 : Structural Review o[ PV Array Mounting System Is the array to be mounted on a defined. permitted rcof sructure? Eyes Ello U No due to non-contpliant roof or a ground n\ount, submit completed worksheet.for the structure wKSl. Roof Infonnation: I ls rhe roohng type lighlweight (Yes = composition. Iightweight masonry metal, etc...)YES I No, submit completed worksheet Jor rooJ structure wXS, (No = heavy masonry. slate, etc...) 2. Does the roof have a single rooF coveringz Eyes E no lf No, submit completed worksheet lor roof structure WKSI. I Provrde method and rype of weatherproofing roof penelralrons (e g flashing. caulk)Flashinq. geocell sealant M ount ing S y s t ern I nf onnat ion : I ls the mounling structure an benealh the module frames? tf No. provide detsils ol st/uctural Lttachment certiled by a design professional. 2. For manulactured mounling systems, hll out information on Ihe mounting system below a. Mounting Sy stem Manufaturer ZeP Pro .1cr Name and yo,1"16 Comp Mount Type C b Tolal Weight of PV Modules and Rails 1680.9 lbs d. werghr per Attachment Pornt (b + c) 19.55 lbs(if greater than 45 lbs,seewKsl) e. Maxrmum Spacing Belween Altachment Points on a Rail 48 inches (see product manual for maximum spacing allowed based on maximum design wind speed) Tolal Surface Area of PV Modules (square feel)701 elr ineered producl designed to mount PV modules with no more than an 18" gap Yes tr No f g lr Distributed Weight of PV Module on Roof (b + i)2.397 lbs/ft IJ distributed weight of the PV system is geater than 5 lbs/fC, see wf\51. Step 2: Electrical Review o[ PV System (Calculations lor Electrical Diagrar) ln order for a Pv system to be consider€d for an expedited permit process, the following must apply: l. PV modules, utiltty-interactive inverters, and combiner boxes are identified For use in PV systems. 2. The PV array rs composed of 4 series strings or less per inverter. l. The toml inverter capacity has a con(inuous ac power outpul 15,440 watts or less 4 The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One ofthe standard electrical diagrams (El. i, El.la, El.lb, or El.lc) can be used to accurately represent the PV system. ln(eractive PDF diagrams are available at www.solarabcs.org/Permirting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fll in. f the electical system is more complex than the standard electrical diagram can elrectively communicote, provide an alternotive diagram with appropriate detail. 2 ExlEDtrED lERMlr PRocEss roR PV sysrEMs c Total Number of Altachment Points 86 =3 -! v v a P z 51N uoslarN seuJoqf ^s,N,o L! :azrs 9v ursts^s arzL, :sselppv alts _€ u,trd :eurPN alts suals^s nd eseqd-alours 'alecs-lleus rol ueld alrs @s^.!.!lsllsl u@rodJosl!}.ps V l,i H,! 1, .l '. llli1 .1 I I , lll, 1l . I ll.l ' l,tll., 't , ,.11 ' ll: Ip I I l=f itI lll atII NVrd lr_rs wlrs^S DNlur_s cuvcNVrs 4-- E d \ \ I r ',".1 STANDARD STRINC SYSTTU ELECTRICAL DIAGRAM One-Line Standard Electrical Diagram for Small-Scale, Single-Phase PV Systems site Name tuo, Be System AC Size Site Address ,.*.u" Thomas Nielson NT5 o EQU PN,4L NT 5CHEDULE TAG 1 2 3 4 s 6 7 E 9 OESCRIPTION SOLAR PV MODULE J.BOX (IF USED) COMBINER (IF USED) DC DISCONNECT DC/AC INVERTER GEN METER (IF USEO) AC DISCONNECT (IF USED) SERVICE PANEL PART NUMBER NOTES 16r rsM.rloDoo5a 13trr 39 Modul.s UTILITY SERVICE I OG2?2URB Cutler Bahmer 60A 240vac Non-lusrble NEMA 3R -rqvec. g1 r n.mN. 391a aus, !1a Nvenrea ocpo (SEE NOTE 5 FOR INVERTER OCPDS ALSO SEE GUIDE SECTION 9) Disregard if provided with inverter BU ILDING GROUNDING ELECTRODEFOR UNUSED SERIES STRINGS PUT "N/A" ifl BLANK ABOVE SEE GUIDE APPENDIX C FOR INFORMATION ON MOOULE AND ARRAY GROUNDING A CONOUIT ANO CONDUCIOR 5CH€OULE rAG OESCRIPTION OR CONOUCTOR TYPE COND 6AUGE NUI\,IBER OF CONOUCTORS 1 1 3 CONOUIT TYPE N/A va EMT IA NA EMT EMT EMT CONDUIT slzE N/A N/A 14' x1 NA 314', 3t4' 311' USE-2 D or PV WIRE O BARE COPPER EO, GRD, COND, (EGC) THWN-2 E or XHHW-2 O or RHW2 tr THWN-2 E or XHHW2 tr or RHW-2 tr INSULATED EGC DC GROUNDING ELECTRODE COND, THWN-2 E or XHHW-2 E orRHW"2 E INSULATED EGC 10 10 tq NA NA I 0 I I MoDULES lN SERtES SOURCE-CrRCUlT. t.80x8 vooules nt ! srntes sounce-crncurr ! tataTMEmrirn o AC 0rscoDC DrSCO o t.,tooures rru i se-nn s sou nc e-cr ncu r r ! INVERTER ocPo )MAN ocP o MoDULES tN . srnres souace-ctncutr I ffiffiIIIIII F c- c.o ) c- i c c t 1 A A A A 1 . ; i T I I I NOTES FOR STANDARD STRINC SYSTEM ELECTRICAI- DIACRAM Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems System AC Size Site Address Site Name D"- n, Thomas Nielson NTS PV MODULE RATINGS @ STC (Guide Section 5) MoDUt t MAK1- Trina Solar r,.4oDULE MoDEL TSM-300DD05A.18(ll) MAx PowER-PotNT cURRENT (tMp) I 19 MAx PowER-PorNT voLrAGE (vMJ 32.6 oPEN-crRcurr VoLTAGE (v.,-) 39.9 INVERTER RAI|NGS (Guide Section 4) NOTES FOR ALL DRAWINGS OCPD = OVERCURRE\ I PRO IEC I ION OEVICE NATIONAL ELECTRICAL CODE. REFERENCES SHOWN AS TNEC XXXXX) S]GN FOR DC DISCONNECT PHOTOVOLTAIC POWER SOURCE RATEO MPP CUfRENT RATEO MPP VOLTAGE MAX SYSTEM VOLTAGE SIGNS_SEE GUIDE SECTION 7 MAX CIRCUIT CURRENT sHoRT-CTRCUIT CURRENT (lsc) MAX SERIES FUSE (OCPD) I MAXTMUM POWER (P"^,) _.*""g9trrr!ryy*L i vOC TEMP COEFF (mvPcEl or "/"/'C !) IF COEFF SUPPLIED CIRCLE UNITS *r.-*" ^111. io"rt" TNVERTER MoDEL Solivia 3 8 TL , MAX DC VOLT RATING t\4Ax PowER @ 40.c NOMINAI AC VOLTAGE ,* * ar**=* WARNING: ELECTRICAL SHOCK HAZARD_LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION 9.64 A 15 A 300 w 1000 v -0.29 600 3800 240 15.8 20 2 ) HIGHEST CONTINUOUS AMBIENT IEMPERAlURE BASEO ON ASHRAE HIGHEST MONTH 2Ol. ORY EULA TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. IIIGHEST CONTINUOUS TEMPERATURE e "C 1) IF UTILITY REOUIRES A VISIALE.AREAK SWITCH, DOES THIS SWITCH IVEET THE REOUIREMENT? YES T NOtr N/AE 2) IF GENERATION METER REQUIREO, DOES THIS METER SOCKET MEET THE REOUIREMENT? YES E NO tr N/A I 3)StZE PHOTOVOLTATC POWER SOURCE (DC)CONDUCTORS BASED ON MAX CURRENT ON NEC 690 53 SIGN OR OCPD RATING AT DISCONNECT NOTES FOR ARRAY CIRCUIT WIRING (G!rde Sectlon 6 and 8 and Appendrx D) 1,) LOWEST EXPECT AMBIENT TE[4PERATURE BASED ON ASHRAE MINIMUM MEAN EXTREI\IE DRY BULB TEMPERATURE FOR ASHRAE LOCATION I\IOST SIMILAR TO INSTALLATION LOCATION LOWEST EXPECTEO AMBIENT TEMP ., 'C NOTES FOR INVERTER CIRCUITS (Gurde Sectron 8 and 9) THIS PANEL FED BY MULTIPLE SOURCES {UTILITY AND SOLAR) I\,4AX OCPD RATING AC OUTPUl CURRENT NOMINAL AC VOLTAGE 15.8 A 240 v 2 ) 2OO5 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED STATES (PALM SPRINGS, CA IS 4{,1'C) FOR LESS THAN 9 CURRENT.CARRYING CONOUCTORS IN ROOF.MOUNTEO SUNLIT CONDUIT AT LEAST 0,5' AAOVE ROOF AND USING THE OUTDOOR DESIGN IEMPERATURE OF 47"C OR LESS (ALL OF UNTTED STATES), 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Gude Section 9) 5,TOTA. OF i INVERTER OCPD(S). O|.E FOR EACH I\VERTER DOES TOTAL SUPPLY BREAKERS COMPLY WITH 12OOlo BUSBAR EXCEPTION IN 690 6A(BX2Xa), YES El NO tra) 12 AWG. 90'C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MOOULES wlTH lsc OF 7 68 AMPS OR LESS WHEN PROTECTED BY A 12'AMP OR SMALLER FUSE b) 1O AWG,gO"C CONDUCTORS ARE GENERALLY ACCEPTAALE FOR I\,IODULES WITH lsc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 1s-ALlP OR SMALLER FUSE Dal€ - co Uoca- i c F a SIGN FOR INVERTER OCPD AND AC DTSCONNECT irF US€D) SOLAR PV SYSTEM AC POINT OF CONNECTION t' STANDARD STRINC SYSTIU ELECTRICAL DIACRAM One-Line Standard Electrical Diagram for Small-Scale, Single-Phase PV Systems Site Name: ."i* e- System AC Size Site Address ".,-., Thomas Nielson NT5 o EQUIPMENT 5CHEDUIE TAG DESCRIPTION SOLAR PV INODULE J-8OX (tF USED) COMEINER (IF USED) DC DISCONNECT DC/AC INVERTER GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL PARTNUMBER ]NOTES ,nn. .s*rooooo* ,"r,,r I rs iroout""1 2 3 4 5 6 ? 8 9 UTILITY 5ERVICE I oG222URB c!terHammer 60A 240Vac Non-rusrbre. NEMA 3R -tlLVAc. 17s AMA|N. 2oo ABUs. 30 atruvenrenocpo (SEE NOTE 5 FOR INVERTER OCPDS. ALSO SEE GUIDE SECTION 9) a Disregard if provided with inverter BUILDING GROUNDING ELECTRODEFOR UNUSED SERIES STRINGS PUT "N/A" in BLANK ABOVE SEE GUIDE APPENDIX C FOR INFORI\4ATION ON MODULE AND ARRAY GROUNDING A CONOUIT ANO CONDUCTOR 5CHEOULE IAC OESCRIPTION OR CONOUCTOR ryPE COND, GAUGE JO 10 l0 NA NA I I I NUMBER OF CONDUCTORS -:, NA NA CONDUIT TYPE N/A N/4 !Ml NA r.q EMT EMT EMT CONDUIT SIZE N/A 3'14" 3r4' I USE-2 0 or PV wlRE E AARE COPPER EO. GRD. COND, (EGC) THWN-2 E or XHHW-2 tr orRHw-2C THWN.2 E or XHHW.2 D or RHW.2 E INSULATED EGC DC GROUNDING ELECTROOE COND. lHry!?! gr\l1Hw-2 tr o, RHw-2 tr INSULATED EGC 2 3 5 3 9 f,4oDULEs tN SERtES SOURCE-CtRCUlr I I BOX7 tvoouLgs tr i senres souacr-ctncurr! rrIMMrfi o AC D SCOoc o!sco 7 l,looures tN i s e-n r E s sou ncr-c r ncu r r I INVERTER OCPD )MAN oc o MoDULES tN rse-ar es sou acg-cr nc u r t ! ffiffiIIIIII n 2 I do U Ia- F z F a 1 AA A A A NOTES FOR STANDARD STRINC SYSTEM ELECTRICAL DIACRAM Noles for One-Line Standard Electrical Diagram for Single-Phase PV Systems System AC Size Site Name o.- n, Thomas Nielson SLZE NTS Date PV MODULE RATINGS @ STC (Guide Section 5) NOTES FOR ALL DRAWINGS: OCPD = OVERCURRENT "aO,tcttOtt OtvtCi NATIONAL ELECTRICAL CODE6 REFERENCES sHowN AS rNEC )O(XXX) SIGNS.SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT PHOTOVOLTAIC POWER SOURCE XATEO MPP CURRENT RATED MPP VOLTAGE MoDULE MAKE Trina Solar iyqouLe !qoeL,1'qqggopD!!4 1tj!! ) I MAx polryryprorNrlylllNl(rld I ef s JqfgqllryUV!LIA!;E(vMp) 32.6 . oPlycrRcurlvlLrlcllyecr .31 1 sHoRr-crRcurr CURRENT (rs.) _9!4- MAx SERIES FUSE (ocPD} IC MAXTMUM PowER (Pr r) 10 MAx VoLTAGE arYP 6oov-) looo voc rEMP coEFF (mvl9tr "f1l9ll ! IF COEFF SUPPLIEO. CIRCLE UNITS INVERTER RATINGS (Guide Seclion 4) )o MAX SYSTEM VOLTAGE N4AX CIRCUIT CURRENT ^*1ra*q=-o91t1 |NVERTER MooEL Solivia--_ MAX DC VOLT RATING MAX POWER @ 40oC- NOMINAL AC VOLTAGE bUU , u?09 -249 21.6 30 SIGN FOR INVERTER OCPD AND AC DISCONNECT (lF USED) soLAn pv svsreu AC POINT OF CONNECTIONMAX AC CURRENT MAX OCPD RATING WARNING: ELECTRICAL SHOCK HAZARD_LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOI\4INAL AC VOLTAGE 21.6 240 THIS PANEL FED BY MULTIPLE souRcEs (uTtLrw AND soLAR) 25 TL NOTES FOR ARRAY CIRCUIT WIRING (Gurde Seclion 6 and 8 and Appendrx D)NOTES FOR INVERTER CIRCUITS (GU]de SacToN 8 ANd 9) 1 ) LOWEST EXPECT AMBIENI TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOS'T SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECIEDAMBIENT TEMP , "C 2 ) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2"/" DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION, HIGHEST CONTINUOUS T€MPERATURE u "C 2,) 2OO5 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47"C IN THE UNITED STATES (PALM SPRINGS, CA IS 44,1'C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF.MOUNTED SUNLIT CONDUIT AT LEAST 0,5'ABOVE ROOF AND USIN6 THE OUTDOOR DESIGN TEMPERATURE OF 47"C OR LESS (ALL OF UNITED STATES). a) 12 AWG. 90oC CONOUCTORS ARE GENERALLY ACCEPTABLE FOR MOOULES WITH lsc OF 7.68 AMPS OR LESS wHEN PROTECTED BY A 12-AMP OR SI,IALLER FUSF b) 1O AWG, gO"C CONO!CTORS ARE GENERALLY ACCEPTABLE FOR MOOULES WITH lsc OF 9.6AMPS OR LESS WHEN PROTECTED BYA ItAMP OR SMALLER FUSE, 1)IF UTILITY REOUIRES AVISIBLE.BREAK SWITCH. DOES THIS SWITCH MEET THE REOUIREMENT? YES I NOtr N/AE 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REOUIREMENT? YES E NO tr N/A I 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC)CONDUCTORS BASEO ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUI CIRCUIT (AC)CONOUCTORS ACCORDING TO INVERTER OCPo AMPERE RATING (See Gude S€ction g) 5ITOTAL OF " INVERTER OCPD(S), ONE FOR EACH INVERTER DOES TOTAL suppLy BREAfEqS coMpLy wrrH r2b;/o BUSBAR ExcEproN rN 690.6418)r2)ra)? YES E NOO F c- do Iod1 =c a i I t' I Site Address: