Loading...
HomeMy WebLinkAbout20166267 - Permit (2)@ City of Santa Ana Permit Counter: (714) 647-5800 20 Civic Center Plaza (lvl-19), Santa Ana CA92702 Electrical Permit #: 2lJ166.267 Pin #: 17132lnspection Requests: (714) 667-2738 lnspector Section: (714) 647-5853 Project Address: 2333 N Linwood St Unit: Block: NA Bldg: Tract; 8370 Address Range: Historicr No Suite Range: Zoning: RlAssessor'sParcel 396-242-13 Lot.35 Ownerl Address Jeffrey J Pereira 2333 N Linwood St Santa Ana, CA 927056959 (714) 317-9058 Fee Type 011'16002 51600 General Plan Update Amount 21 .25 Qty 0.00 Fee $0.00 Phone Tenant Name: Contractor Address: Vivint Solar Developer 9847 Pioneer Blvd. Santa Fe Springs, CA 90670 (5621942-127OPhone State Lic #: 973756 Lic Type: ' C-10, C-46 Bus. Lic #: 345470 Workers' Compensation lnsurance:Carrier: American Zurich lns Co Policy #; WC5096013 Expires: 1110112018 Building Use: Job Type: Nature of Work Single Family Dwelling Solar Solar Occupancy: Constr Type Code: R-3, U VB cEc 2016 Notes: lnstall(29) roof mounted solar panels. FEES PD ON 10196838 Planning Condilions: Planning Approval By:Date Date Date lvlisc. Receipt: l\,lisc. Receipt: Misc. Receipt: Total Plan Checked By: Permit lssued B Subject to Field: Amsden, Julie 06122t2018 Account# Buildins Permit #: 1 0196838 Every permit issuod shall become invalid unless the wo on lhe site authorized by such pemil is cofimenced within 180 days after its $suance. ot if the wofu authorizod on the site by such pemtt is suspended ot abandoned fot a period o1180 days after the time the work is commenced. $0.00 $0 00 $0.00 lnspector tntD# 2018-144236 Fee Totali Paid to Date; Balance Due: ELECTRICAL-INSPECTOR RECORD IDiSIG.COMMENTSAPPROVALSDATE Site-Work Underqround Liqht Standards Spas, Pool, Fountains Siqns (monument) Lile Salety /Low Voltaqe Fire Alarm / Dampers Communications Cable Buildinq Under Slab / Floor Bondinq / Groundinq / UFER Transformers Torqueinq Sub-Panels Air Conditioners Roof Top Equipment Factory Wired Unit Walls (Conduit) Walls (Rouqh) Ceilinqs (Hard & Sollit Rouoh Ceilinos (T-Bar Rouqh) Meter Release Rouqh Service lvleter rLfz.k7/'x//iFINAL Noles, Remarks, Etc 1)WNEk n!Il,DIR Dr.r.(',1l{,\r()N U!I86!8!:.QAM[ENIAIION DECI.AXAIII]N I hcrcby rfrnr undcr rcnalryorp.rjuryonc ol'rhc lbllowing dccl.rutions: I h.rc.trd will nuinrain d ccnifiQrc of Co.scnr tu sc!f.lnsurc lhr *orkcr' .oq)cnqrt,n rjbr Codc. for lhc pcrabntuna ofltu wori fo, shi.h rh. psmil i\ hsu.d r\ tn,!idcd ktr b) Sc.riotr 17(xr otthc illnri anworkcs comrcn!,tion insurrrcc. i\ rcquir.d hySccrion.1700.llhc Labor Codc.lor lhc Pc.fonmn'c ol collr|[n\rrion in\u n.c cntricr JxlIrllrynumh(r uc: ltlUSuteo I ?de f( -t 1P -l ccdifyihrl ir rhc pcrtormdncu orrhc worl lor trhirhrhk p.rmii t hsued.l \hrll.ot cnlkrvanylc6on in onv'tunncr o ns ro bGorrE ubjcd k, rltr uo*cr{co'nFnsarion l.*s olCalilomia. Md i3Nc rhlr it I should hcconE slhj'rr l' lhc sorlcN conr.nqlionFUvisions olSdtri:lnnofthc tjtry Code.l shrll lodhwirh .onulv wilh rhoe pmvistns WARNINCT Failurc ro Kuc *ttrkc6'.onrcnsrlion.o\cmec is unlawltl- md sh0ll suhjccr an. ll)lovcr to mtui'd trtrokis d .nil *dia 'Dt "7" 1vgottuGrf)1 r kr l,Ic!Nsrl) (r)Nl RAc l!rR DIEUSAIIQN lherci,yrtfirmundcrFnollyorr.riuryrlurlamliens.rlund.trrovnionoiChnFlc.9(commminswithSccrbnTfixJ)'rllivisinl of lhc Dusinc$&d Pbri$ionsCode. drd myli.cn$ n ir full tu.c xl calccl lo 'a+'t F cL-' C(INS'[It](:TIoN LENDIN(I (:ENCY Ihcrchynfiirmumldpcndry.rPcrjurylhlrlhcEnrconsrru.rionlcndincqcn.yturhcPedunturctolthcworkior*hichrhi\pcnnnis isrcd rsc. rl)97. Ci! C ) kndcf\ Ainrc\\: - APPI I(]ANT DFCI ARA'II(}N I hsc+,y aninn undcr !cnrlry otl).rlury onc ollhc lollowins dccl,rarion\: Dcnolirion lcnnirs A\bc{$ Nolil-r.!n'. Fcdchl RcBuhr ions lTirlc 4(1. Pan6l _Rcqrird lInd of Norilicrli.n _l rcnni rharthc fcdcrr I r.Eu lar io. l.c.liitlhrr I havc.e rhi\apf iscoturr I a8lc hcomnlyrirhrllCilyrid C.udy ordirrrcs rn Slrrcl,r*srclnt rtrvc rctrrirrrdplopcn,:,'_:ry'p:- Pole Bases I h6cby amrm undcrycnolly of p.riury rhol I !m cx.hpr rrum ih. ClntacloF Liccn$ tnw for lhc lolk,winS rclen (le 70l l 5 Busincss atn Eofcrsio. Cod.): Any Ci!, or Counry which Equncs a Fnnir ro consldcr. ahs inlPmvc. dcmliib or rcron anv strucure, prior ro irs issurNc. ako tqnirs rhc applic!tr| for stch Fmir to fiha si-sncd Mr.mrr rhrl hcorsh. i liccn{d poFu.r , b rhc tmvisioni ot rhc Cotrlfurols Licco€d llw (Chol)ler 9, C.ndcftinB q'iln Scclion 70fi) of Divhion :l o, rh' Busin's 8nd Itofcssnrns Codc) or lhd hc or shc t .r.mpt rhcrcfrom and lh. btrsis for rhc rlh[sd ex.nflion Afl,liolari.norSerbn?0:]15hvt'rv aptlicanlror,r.rnilsubjccrslh.0PplicanlloacivilDenalrrotnormorclhanfildhundrcddnllaN(S500) l. as ownq ot lhc pmFriy. or my .nPloF.s wirh vogcs 0s thcn sb cd.D.ns0tion. sill do rh. m* and he smrum is mr inrcndcn or.nar.d n" sh ( Sa,7{}44, Busincs snd kolc$ions C.d.r TIE Conlncrdis Liccnr Llu dcs nol opllv lo an osNr or rhc,mtEny who l{ildsor ir!6ws rhcMn. a,i *ho d{B h wo* himsclf or h.r*lf or tnmusn ,ris or h.r own enPl'v'cs trovidcd rhnr su.h inprolcrnk e nor ir cndcd or ofttd for sL. ll howcvcr. rlt blillin3 .r intoEmnr k sld rirhin onc Fr ;tcomphri.n. tth Ovrcr Build.r *ill hnE llE burdcn ol Dmvins rhd rE or shc dil mr t iU or iqtoE rhc Impdrv ro lr,uIrEoI -1. N o*ftr dr rh. popcny- om c&lusivoly contoclils sirh li.cnsd conlroclos ro Ltn{rucl llE I'ojC{ (Sd 7O4{. Bl\ims ,d PiDrcsion Codc: The C{,nlacrols Liccnsc l-Dw docs nor.DP!y k' !no*ncr orProrcrrvsho buildt or imrorts rhcrcotr ond wh. conrmds for s!.h pmFh wnh a C. mrodn L..nsd pununr ro rhc co.lr.dor's l-icent ln*). -l dm cx.mpr urdcr S(tn,n-. B. & P C lor lhh ...s.tr Dor. , O$ncr The Solar America Board for Codes and Srandards (Solar ABCS) Expedited permi( pro- cess provides a means to differentiate systems that can be permitted quickly and easjly due ro rheir srmilarity wirh rhe majoriay of small-scale pv systems Those sysrerns lvith unique characLeristics may be handled with small additions to this Expedjred permir Process or may require much more informaaion, depending on the uniqueness of rhe insrallarion. The lollowing pages conrain forms for rhe Srandard String System ro use wirh rhe Expe_ dired permit process. The Micro-tnverret AC Module, and Supply-Side Connection lorms are also available as inreracrive PDF tiles ar wr,vwsolarabcs org/permirring In jurisdic_ tions thar have adopred the Expedired permir process for pV Sysrems. these forms can be filled out elecrronjcally and submirted in eirher prinred lorm and via email. An elec_ tronic formac is used so thar rhe supplied informarion is srandar.lized and legible tor the local jurisdicrion. @ 2ol ax,aat- RR +- '\6 \) ,,. ,c)l l-:. \,/. rr:CtlOOL DIS lril(jI IXI'EDITELT I'E fu\lIT IR0CE5\ Ti,)R P\ S\'5TEi{5 I I I I ExPEDITED PERJVIIT PROCESS FoR PV SYSTEMS STANDARD STRI NC S\.STEM PERI,IITTYPE'BLOG LBG :LCOD ZONF MICFiC PERM!T I r .r'. FEE YES NO . EXPEDITED PER^IIT PROCESS FOR SNLALL-SCALE P\'S\-5TEN,lS S IANDARD 5IRtsr., j\: tErrr The information in this guideline is intended ro help local jurisd ictions and contractors idenrih/ when Pv system installations arc :iimplc, nccding only n basic review and when an insraliation is more complex. Ir is likely rhar 50 % -75 % of all residendal systems will comply with lhese simple criteria. For proJects that farl ro meet the simple criteria, resolurion sreps have been suggested to provide as a path ro permit approval. Reqrireil InJoflndtiofl for Pernit: t Sire plan showing localion of major components on the prooerrv This drawinq need not be exacrlv to scale, but ir should represenr relative locarion of components at site (see supplied example site plan). PV arrays on dwellings with a 5 perimeter space at ridge and sides may not need separate frre service review. 2. Electrical diagram showing PV array configrrrarion, wiring sysrem, overcurre t protcction, itrverter, disconneLrs. required signs. and ac connection ro buitding (see supplied sandard electrical diagram). 3. Spcciflcarion shccts and installation manuals (if available) for all nlanufactured contponents including, but nor limiled to, PV modules, inverter(s), combiner box, disconnectS, and mounting sysrcm. Step 1 ' Structurai Review o[ PV Anay Mounting $ystem Is the ar(ay to be moqnqed otr a defined, ler4itted roof structure? EJVes E no I No due to non-compliant rooJ or a ground mount , sLtbmit campleted wat ksheet .for the structurc WKS L R@f hfontation: I Is rhe roohng rype lighMeighr (Yes = composition, lighrweighr masonry. meral- "1a . ycomp shingle IJ No. submit compLeted worhsheet jot rool struc1re WRSI (No = heavy masonry slate. etc. .). 2 Does rhe roof have a single rooF coveringt Elyes I r.to IJ No, submit cornpleted worksheetJor roor structure WKSl. 3 Provide merhod and rype of wearherproofing roof penetrarions (e.g. flashing. 63,1L1.flashing Mornting S! stem Sormatiort: I ls Llrc Ilrounti[g stluLturc dlr beneath the modlrle frames?Yes tr prur.luL-t dcsiSrred ru nroulit PV nrodules with l1o n-rore thalt alr 18" gap No IJ No, prol)ide details ol structurq.l q.ttachment certif.ed by a design professional. 2. For manufactured mountlng systems, llll out inlorrnation on tlte r oullLiIg sysLel Ucluw a vloun no Svstem Mdnufacturer EcoFasten loducr Name and r,1pds1x Rock it t of PV Modules an'l Ra'ls 712 4 lbsb. Total weigh c. TJta. Number o'ALrachrenr Po,nrs22 d. Weighr per ArBchment Poinr (b-c)32.4 lbs (if greater rhan 45 lbs,seewKst) e. i\,laximum Spacing Between Artachrnent Points on a Rail 48 inches (see product manual for maximum spacing allowed based on maximum desrgn wind speed) I Total Surtace Area oF PV Nlodules (square Feet)246.5 It] 2.9 lbsi fttr If dbtributed weight of the PV slstem is greater than 5 lbslfF, see WRS1. Step 2, Electrical Reviev, o[ PV System (Calculations lor Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. Pv modules. utili[y-interactive invefters. and combiner boxes are idenrined for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter 3. The tocal inverter capacity has a continuous ac power outpur Il.440 War$ or li:ss 4. The ac interconnection poinr is on rhe load side of service disconnecring means (690.6418)t. 5. One of lhe sandard elecrrical diagranrs(El.l.El.la.El.lb.orEL1c)canbeusedcoaccuratelyrepresentrhePV system [nteracrive PDF diagrams are available at ww\rsolarabcs org/permrrung Fil! oLtt the srundqrd elecn lcal dio.gram completeb/ A qutde b the electri{ql didg'am ,s plotid.ed ta help rhe arylicant unLlerstanLl eac\ btaak to fll in If che electricul s-vstem is more cctmpler tl:(ln the standd.fd eleLtriul dtLrgrq.m can effzctively tDmmunicete provide ar,lltertutive d-iaqtanl vltt\,tpproprtate detaii 2 l\pEDltaD l'tR.r,ril t'R()CEr) t()R l\ iysTL\rs i g Disrributed weighr of PV ModuLe on RooF (b - 0 Site Plan for Small-Scale, Single-Phase PV Systems Site Name: peneta,c Site AddreSS: 2333 N Lnw@d sr sr System AC Size:855 NT5 SLOPE 22% r',),uuoouru" S oa,ouoor,rt 230 aoMP sHrNc,LE (2) SLOPE .22 AZIMUTN - 140 lOMP,SHINGLE o)sLoPE.22 A2tMiltH - 230 AOMPSHINGLE(, sLoPE . 22 COMP,SHINGLE rf)oF-c\to) O z Fz. aFU)ooo =z. =z (f) cf) (f)c! SITE PLAN 1 2 o M N **N ,,%, N '.r%, N% N SCALE: 1/8'= I '0" STANDARD STRINC SYSTEM SITE ['LAN F Uo c- F d o to Conlr.clor Nam Ptdress ad Phon6 Vivint Sola. Developrent 562-942-12701 One-Line Standard Electrical Diagram for Small-Scale, Single-Phase PV SystemsVrvml Sotar Oeveloporenl 562-942-1270 Site AddreSS 2333 N L,nw@d sr st Site Name:PERETRA 855System AC Size NT5 o EOUIPMENT SCHEDULE DFSCRIPTION sornn pv uoourr J,BOX (IF USED) COMBINER (IF USED) DC DISCONNECT DC/AC INVERTER GEN METER (IF USED) AC DISCONNECT {IF USED) SERVICE PANEL PART NUMBER NOTES 1 JKM295M-6og 2 E!!?R xEgqo lL 0221Rd 2 3 .l UTILITY SERVICE6 8 9 _r40 vt\c, l3s A M4lryr_l:s A e!l9r l0 {r[vEB]ER ocPD (SEE NOTE 5 FOR INVERTER OCPDS, ALSO SEE GUIDE SECTION 9) I Disregard if provided with inverter BU IL D ING GROUNDING ELECTRODEFOR UNUSED SERIES STRINGS PUT "N/A' in ELANK ABOVE SEE GUIOE APPENDIX C FOR INFORIUATION ON MODULE AND ARRAY GROUNDING rAG DESCR PTION OR CONDUCTOR TYPE COND, GAUGE 6 NUMBER OF CONDUCTORS 2 1 CONOUlT TYPE CONOUIT SIZE USE-2tr or PV WIRE E BARE COPPER EO. GRD, COND, (EGC) THWN'2 E or XHHW'2 D or RHW'2 tr THWN-2 E or XHHW-2 tr or RHW-2 tr INSULATED EGC DC GROUNDING ELECTRODE CONO, ) l 314" 1! 314 5 3 314 29 L,toouLes tru SERTES SOURCE-CrRCUtT. ]"BOXMoDULES rN ! senres sounce-crncurr ! INVERTER COM BiN ER AC O SCODC DlSCO MoDULES rN ! sr-nrrtsouncr-crpcurt!I )ocP INVTRIER OCPD MODULES tN ! se-nrrssounce-crncurtl A CONOU T ANO CONDUCTOR SCHEDULE THWN-2 E or XHHW-2 D or RHW-2 tr INSULATED EGC STANDA}TD STRINC SYSTEM ELECTRICAL DIACRAM F o Uo L o F o 1 t.,ll \ I s 6 ! 1 3 1 Notes for One-Line Standard Electrical Diagram for Single-Phase PV SystemsV'v'nl solar Deveiopmenl Site Name: "- *" sys tem AC Size: ," Site Address; NTS SIGNS SEE GUIDE SECTION 7 PV l\,1ODULE RATINGS @ STC (Guide Section 5) NOTES FOR ALL DRAWINGS: oCPD = OVERCURRENT PROTECTION DEVICE SIGN FOR DC DISCONNECT PHOTOVOLTAIC POWER SOURCE MoDULE I\,1AKE Jinko Solar MoDULE MODEL . JKI!,l295M-608 MAX POWER.POINI CURRENT (IMP) MAX POWER.POINT VOLTAGE (V,P) OPEN.CIRCUIT VOLTAGE (VOC) SHORT,CIRCUIT CURRENT lISC) IVAX SERIES FUSE (OCPD) MAXIr\,4UM POWER (PMd) MAX VOLTAGE (TYP 6OOVD' J VoC TEMP COEFF (mV/oCtr or %/oCE) IF COEFF SUPPLIED CIRCLE UNITS NATIONAL ELECTRICAL CODEO REFERENCES SHOWN AS (NEC XXX XX) RATED MPP CURRENT RATED MPP VOLTAGE I\4AX SYSTEM VOLTAGE na na na INVERTER RATINGS (Guide Section 4) INVERTER I\,4AKE SOIAT tdoE INVERTER I\,loDEL SE7600H-US l I\,4AX DC VOLT RATING r\,4AX POWER @ 40oC NOMINAL AC VOLTAGE I\,1AX AC CURRENT MAX OCPD RATING T,4AX CIRCUIT CURRENT L na WARNING ELECTRICAL SHOCK HAZARD LINE AND LOAD I\4AY BE ENERGIZED IN OPEN POSITION48 3.8 240 12.5 '15 AC OUTPUT CURRENT 15.83 A NOMINAL AC VOLTAGE 24O v NOTES FOR ARRAY CIRCUIT WIRING lcuid€ Seclion 6 and 8 aad Appendix D):NoTES FoR INVERTER CIRCUITS (Guide Section 8 and 9) 1 ) LOWEST EXPECT AMBIENT TEIIIPERATURE BASED ON ASHRAE MINIMUIV MEAN EXTREINE DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TElvlP , oC 1) IF I]TILITY REOUIRES AVISIELE.AREAK SWITCH, DOES THIS SWITCH MEET THE REOUIREI\,IENT' YES E NOE] N/AE 2 ) HIGHEST CONTINUOUS AMBIENT IEMPERATURE BASED ON ASHRAE HIGHEST IVONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION I\,IOST SIl\,4ILAR TO 2) lF GENERATION METER REOUIRED, DOES THIS METER SOCXET IIIEET THE REQUIREII,IENT? YES O NOf] N/A E 3)SIZE PHOTOVOLTAIC POWER SOURCE (DC)CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT OISCONNECT INSTALLATION LOCATION HIGHEST CONIINUOUS TEMPERATUaE ,," '6 2.) 2OO5 ASHRAE FUNDEMENTALS 2% OESIGN TEMPERATURES OO NOT EXCEED 47"C IN THE UNITED STATES {PALM SPRINGS, CA IS 44,1"C). FOR LESS THAN 9 CURRENT.CARRYING CONDUCTORS IN ROOF.IT,lOUNTED SUNLIT CONDUII AT LEAST 0,5' AAOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47'C OR LESS iALL OF UNITED SIATES). a) 12 AWG, gO"C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH lsc OF 7.68 AMPS OR LESS WHEN PROTECTEO BY A 12-AMP OR SI\.{ALLER FUSE b) 1O AWG, gO"C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH lsc OF 9.6 A[.{PS OR LESS WHEN PROTECTED BY A 1s-AMP OR SMALLER FUSE 4)SIZE INVERTER OUTPUT CIRCUIT (AC) CONOUCTORS ACCOROING TO INVERTER OCPD AIvPERE RATING. (See Guide Seclion 9) 5)TOTAL OF -- INVERTER OCPD(S) ONE FOR EACH INVERTER DoES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2Xa)? YES E NOtr - c- do Uo =:d o - o NOTES FOR STANDARD STRINC SYSTEM ELECTRICAL DIACRAM saora Fe Spri.os. cA $2-942-t2TO Dale 9.'1 A 32.4 v 39.7 v 9.61 A 20A 2gS w 1OOO v 0.29 SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) SOt AR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR)