HomeMy WebLinkAbout10198320 - Permit (2)q
Project Address: 1345 S Parton St
Assessor'sParcel: 0'13-1'13-12 Lot: 13
LJ n it:Bldg: Address Range:Suite Range:
Zoning: RlBiock. l3 Tract: 352 Historic; No
@ City of Santa Ana
Permat Counter: 1714) 647-5A00
20 Civic Center Plaza (M-19), Santa Ana, CA 92702 Building Permit #: lO{98320
Pin #: 94500lnspection Requests: (714\ 667-2738 lnspector Section: (714\ 647-5853
1st FL Area:
2nd FL Area:
Other Areas:
Garage Area:
Total:
Description of Work: lnstall (12) roof mounted solar panels. Perchecklist.
Planning Conditions:
Engineer: Douglas M Morales, Engineer
Owner: Julio Velasco Contractor: Solarmax Renewable Energ Douglas M Morales
Build jng Use:
Job Type:
Nature of Work:
Existing Bldg. & Use
Proposed Use:
Single Family Dwelling
Solar
Solar
Sfd Wdet garage
Occupancy:
Constr Type
Code:
Flood Zone:
# of Storiesi
Addressi 3080'l2th St
Riverside, CA 92507
Phone: (951) 300-0788
State Lic #: 972048
Lic Type: C-10, C-45
Bus. Lic #: 346803
Workers' Compensation lnsurance:
Carrier: State lnsurance Fund
Policy #: 9070313
Expires: O4lO1l2O19
R-3, U
VB
cBc 2016
x-0602320276J
,|
Patio:
T.l.Area:
Yards Req'd:
Valuation: $12,000.00
Address
Phone:
Tenant:
Address:
Phone:
License #:
Architect /
Desiqner:
Address:
Phone:
License #:
69't 63
1345 S Parton St
Santa Ana, CA 927071627
(714) 315-4860
ld ing
16802- 516(11000-
s Stds RPvol.v ine
1,an0?- 1161?0trr1"
o.
+: }rr*r*r*rrII2g6?
._ -< q:!
. i1
,5 81
Aut h; : ilTr-7tr4
Eui
011
Bld
nt l
Vis
Planning Approval By
Plan Checked By:
Permit lssued By:
NPDES lnsp. Req'dl
PWA lnsp. Req'd:
Planning lnsp. Req'd:
Landscaping lnsp. Req'd
Amsden, Julie
Date:
Date:
Date: 11/09/2018
Subject to Field:
lvlisc. Receipt
NIisc. Receipt
lvlisc. Receipt
07776002 51501 Permit Fee
07776002 57672 Bldg. Stds. Revolving
07776002 57600 Genetal Plan Update
$4s0.00
$'1.00
$0.00
No
o Fire lnsp. Req'd:
Police lnsp. Req'd
No
No Account#TotalNo
No Flood Zone Cert. Req'd: No 01i 16002 5160i
Every permit issued shall become invalid unlessthe wo* on the site authorized by
such pennit is commenced within 180 days aftet ils issuance,or if the wo* authorized
on the site by such permit is suspended or abandoned for a peiod of180 days aftet
the time the wo* is commenced
I\IlD#: 2018-147581
01116002 51612
$450.00
$1 .00
Fee Total;
Paid to Datel
Balance Due:
$4s1.00
$0.00
$451 .00
lnspector
BUILDING- INSPECTOR RECORD
SITE-WORK DATE ID/SIG.COMMENTS OWNERBUILDER DEL(-ARA ION
I hscby afiirn utrdr pmlty of r€.jury lhat I an clear lLom rh. conttcr.a' Liceise Ld* lffrhe a.llowin! 1t6on (sec.70115
Businss dd Proa6sion cod.): An, ciry or Counry (hi.h r.qunB a pdnrn lo consnld. alt6. impro\€. doolsh or rerEtr any
sle!1u.. rior k, its isuance. also r.qut6 the applicanr lor such peflnrr kr file a sisned srat€mqr that hcor shc 6li.dsd t6udr
lo Ih. Fo\isions ol th. Contncloas Liccns.d tjrv (ch,pr.r L (.(nnnrn iig wnh selion 70L\) of Dn'bion I oa lhc llusiness ed
Prolessions Codc)orrhat he orsh€ is €x.mpl thEciom md llE tr6is for lhc alles.d €xoprion. Anr- viobton oas.atnJd 70r I 5lry atry
appli.mr ror atcmir snbjNrs rhc dpplicantoadv,lpenalryoanornor.rhMnv.hu.drcddollrs(5500).
L a osne ollhc FoFrlt, or my dnplotB snh {as* d rhct sn. .onrpdrslion, \rill do the $ork od lhe $nrc1ue s Nl
inrc .d orolldcd tor ele (Se 7([4, Lrusin* d Prcf6sioN (odc lhc Ci,nhdor.l-te.* I-a$ do6 nol alply ro o otrn€' or
rh. phtdy Rho b{'ilds or iinlyors rh.on. dd who do6 nich N!* hinN€lfor hmclfor though his or h.t o\w enployeB.
provid.n rhar such iryrcr@.nrs @ nor inlod.d or onsarj ror elc I I ho\vd d. $e &ildins or nnproEndl is $ld * ith'n onc y@
oacomphn . nE oNnq atrillg will have lhc burdtr olprcrins rlEt h€ or sh. dd mt bu[j or nDprole lhe propqry lor rh. puls* dl
l.asosnerollhepropfi). n erclusivcly conlracrins \irh I'cen*d .ont{doN ro ..6hd rh.,,ojd (S.r 7044,lr6rn€r5
dJ Poieasion (bde: Thc (orrractois Lic.nsc Law do6 nor aptlyro.n o$trd ofplopen) sho builds or nnpnn6 lhersn,
and \vho conimds fo. such prqds with a Contrrcro(, lice.rd pusudr nr the cdnti.rorr I-icds. hw)
-l
m cxcmpt undq Srxon-, B & P C. for $is r@n
D.re Ofrner:
li!.8!iE8S1C9!!!!LSr!-LlO!pEltAB3lrra!
I h.(by affin un,t6 pdahy of rriury on. ofr h. fdl$vi'u dccltuarn,ns
Ih.vead\villmintain0Ccniicarco,CorsntloSelfJ$trrcforvorksiconfens,rnrn.atmvid.dlorbys.diotrl?00otthc
lnlsr aodc, aor Ihc pfiloandce o f lhc work for \ hich nrc pmnit is isuen
I havc and sill mainlain wolkets comgcnsal ion insu,ance. 6 r.1luir.{ by S€i on .1700 or rhc Lth4r cdd., for tlE p(fom ccoi
'1
s \str!\i NlYro l.h (u Lon insu.atue ctmid and Bnic) nunrbd tuc:
/o7u A, *-
_l cenifyrhat 'n rh€ p€rformlnce oathe \rorl for shi.h rht p.nnir is issucJ, I shallnut dnploy an! pdso. i. any flrmncr
$ d ro b.en. strbjdl b the sorldl .onpmdion la{ s o I Cililomia a.d agrc rhar il I slNuld becomc sbjLrl re lhc
$ort6s conrpdrarionpiorisionsolsNrio.lT00.lrlrLahrcodc,Ishallhnhwnhcomplysirhlho$prorisu,s
WARNING: liflilwe lo wurc qolkod colnpsation covsasc is lnhs rul. and shail subjdr an mtlo]s lo oiminal rsmltis and
cnil fines up to onc hundred rholsd dollau ($100.000)- i'r add(i.n r. thc.o$ of.onlxnsariotr. d nascs c provided lorlhe
(i\1. n.,.1ritrd.rlf'trr\ s lc(1
tl Appli.rnl:_---_._
DECI,6AAIIA!
I n.rcb, ami,n u.d{ pddltyofptrjury rhar Ln lic.f,s.d undd prevision ofCharlg 9 (conomcins $nh salion 7000) oaDivision l
of lhe B6ins dd ProlsioB code, my li.ds. i in atrllao,eadcllel
,',"""",,,*"4Q( /<74 ?/r4'!lft/d'14y',*//4k
catilBl,icuoxL[N.allc-&GEli(r
I hEcby rfiinn und.. LEnally oi pqrury lhal th6€ s a conslru.1io. E.di,! ascncy aor rh. po aomdc. olrlrc \ork aor shich this Fmn is
hsucd(sc 1097.ci! c ).
L..der s Ntrme
afB.rcaMDEct aSalll]x
I holty amm und6 p€nally ofp€.jury on.olthe tollowins d€claalions
Denrlition Pftnn$Asbeeos Norificai ion t'.dsal Rqulations (l nk 40. P.n6)
-Required
txlld oi Nolifi carbo
I .dilr rld rh€ fcd.r.l
'luularioru
resedin8 slB6s rcmo\il ac nor aDplicabl. to rhis pmjcct.
f-hd,[ rldr I ha, e rqJ rhr app](,r'on od sra, e lhar rh€ abor e
'n
tunnarn,n
's
cor(l I asre ro co Dl, wnh all (-ry and (-ounry
&dm\R6 J Srak Lnqs rehrrns ro bu,ld'ns conrrucl'on, dd h6ebyaurhorize Epr6nlariv6 oarhis Cny dd countylo atc olnnlh.
ab.\ . nBtrioncn prop{tt ior nq€.rion
Appli.,nr or ,{Betrl Signrtu.r
l'ci,trilrr n{n,rlp.itrr):
,rrr" lh/f
Set Backs
Forms/Steel/Holdowns
UFER Ground
SLAB Floor
Subf loor/VenUlnsulation
Roof Sheathino
Shear Wall
Framing
lnsulation/Energy
Drywall
Ext./lnt. Lath
Brown Coat
[,4asonry
Pool Fence
T-Bar
Handicap Req
Deputy Final Report
En gineer Final Report
Flood Zone Certif
I
FINAL lllzrl14 .1'12$d,\
Certificate of Occu anc
Not es, Remarks, Etc.
Ereclion Pads
I
+
I
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA'92702
(714) 647-s800
www.santa-ana.org
RESIDENTIAL
PHOTOVOLTAIC
GHECKLIST
soL-01 cBc 2013
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall fill in the address of the project, contractois
licensing information and answer questions 1 -10 below. Complete and sign the certification section.**lf answering NO to any of the questions, plan check shall be required.**
Project Address:1345 S. PARTON STREET
Contractor Gompany Name:
Contractor License Number:
1 Eltr
trtrtrtr
trtr
trtr5
8 Eltr
9. Etr
10. BE
6. trtr
7 trtr
I certify under penalty of
Print name: /3
p under the laws of the State of California th the above is true:
Date:Phone Number:
Email Address:
Rev.2117l2O15
-'-SANTA
ANA,'i,il,l+l
YES NO Are the following applicable to the proposed project?
Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
Will the PV system weigh maximum 3 pounds per square feet or less?
Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
Will the PV system be installed with a space of 2" minimum to 10" maximum between
the underside of modules and the surface of the roof?
Will the PV system be installed without using any ballast system or counter-weight
system?
Will the PV system be installed on a roof having only one roofing layer with no
overlays?
Will the PV system layout provide a three-foot wide clear access pathway per the
latest edition of "Guideline for Fire Safety Elements of Solar Photovoltaic Systems"
by OCFA? (Guideline available on the OCFA website: hto://www.ocfa.orq)
Do the plans show a maximum horizontal anchor spacing of 6 feet?
Do the plans show a minimum of 2-112 inch lag screw embedment into roof rafters?
Are ALL the structural pages of the plans WET stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufactureis PV support information.)
2.
,)
4.
Signature: