Loading...
HomeMy WebLinkAbout3314 W First St - Addressing Letter (2)SANTA ANA CITY COUNCIL Miguel A. Pulido Mayor mpulido@santa-ana.org Juan Villegas Mayor Pro Tem, Ward 5 jvillegas@santa-ana.org Vicente Sarmiento Ward 1 vsarmiento@santa-ana.org David Penaloza Ward 2 dpenaloza@santa-ana.org Jose Solorio Ward 3 jsolorio@santa-ana.org Roman Reyna Ward 4 rreyna@santa-ana.org Cecilia Iglesias Ward 6 ciglesias@santa-ana.org MAYOR Miguel A. Pulido MAYOR PRO TEM Juan Villegas COUNCILMEMBERS Cecilia Iglesias David Penaloza Roman Reyna Vicente Sarmiento Jose Solorio CITY OF SANTA ANA PLANNING & BUILDING AGENCY 20 Civic Center Plaza P.O. Box 1988 ● Santa Ana, California 92702 www.santa-ana.org/pba ACTING CITY MANAGER Steven A. Mendoza CITY ATTORNEY Sonia R. Carvalho ACTING CLERK OF THE COUNCIL Norma Mitre CITY MANAGER Raul Godinez II CITY ATTORNEY Sonia R. Carvalho CLERK OF THE COUNCIL Maria D. Huizar March 15, 2019 Ryan Ratcliff, AIA Also email to: rratcliff@adcollaborative.com architecture design collaborative 23231 South Pointe Dr. Laguna Hills, CA 92653 Subject: Site Addresses for New Residential Project at 3314 West First Street in Santa Ana (formerly 3312 West First Street) Dear Mr. Ratcliff: The City of Santa Ana Planning & Building Agency is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the existence of the addresses for the residential project entitled at 3314 (formerly 3312) West First Street in Santa Ana. The addresses are listed on Exhibit A attached to this letter. Addressing plans are provided as Exhibit B. Please update your records accordingly. You may contact me by phone at (714) 647-5882 or by email at APezeshkpour@santa-ana.org if I can answer any questions. Sincerely, Ali Pezeshkpour, AICP Senior Planner Attachments: A. Address list B. Site Plan AP: M:\Letters, External\Address Letters\Addresses 3314 W First.docx Page 2 of 2 c: Alvaro Nunez, Code Enforcement Manager Kim Fong, United States Post Office Dale Feeney, United States Post Office Federal Express, Administration Joe R. Lopez, Santa Ana Unified School District Julie Amsden, Permit Technician Ruben Colmenares, Orange County Fire Authority Mishele Richards, Orange County Fire Authority Jenny Cradle, Orange County Fire Authority (Vacant), Executive Assistant to the City Manager Mark Paszkiewicz, Registrar of Voters Bill McGovern, Police Community Service Specialist Mirella Vargas, Customer Service Representative Monica Chairez, Customer Service Representative, Lead Kathy Hernandez, Acting Permit Supervisor Jason Kwak, Acting Building Safety Manager Postmaster Santa Ana, United States Post Office Sandie Coyle, Southern California Gas Company Sara Phomprasack, Southern California Edison Company Sherry McCall, County Assessor's Office SAG, AT&T Taig Higgins, Principal Civil Engineer UPS, Administration Vince Fregoso, Principal Planner Units: A - Leasing 203 303 B - Services 204 304 103 205 305 104 206 306 105 207 307 106 208 308 107 209 309 108 210 310 109 211 311 110 212 312 111 214 314 112 216 316 149 218 318 150 220 320 151 221 321 152 222 322 153 223 323 154 224 324 156 226 326 158 228 328 230 330 249 349 250 350 251 351 252 352 253 353 254 354 256 356 258 358 Unit M, Building M - Maintenance Building Property Addresses for Santa Ana Veterans Village Project Primary Address: 3314 West First Street Exhibit A: Address List EV WEST 1ST STREET GOODMAN DRIVE KE N T O N D R I V E GUEST GUEST GUEST GUEST EV MA I L SITE PLAN A-101 Company: Address: Phone No. Project Contact: Email: Principal: Project Manager: ADC Project No: Ryan RatcliII rratcliII#adcollaEorative.com Chris Weimholt laguna hills, ca 92653 www.adcollaborative.com 23231 south pointe drive 949.267.1660 SA N T A A N A V E T E R A N S V I L L A G E Client COPYRIGHT C 20160136 Sh e e t I s s u e D a t e Sh e e t I s s u e & R e v i s i o n L o g 8- 7 - 2 0 1 8 1S T C I T Y S U B M I T T A L 8 - 7 - 2 0 1 8 JAMBOREE HOUSING CORPORATION 17701 COWAN AVE, SUITE 200 IRVINE, CA 92614 949-263-8676 Ryan RatcliII 33 1 4 W . F I R S T S T SA N T A A N A , C A CHRISTOPHER WEIMHOLT No. C-32271 10/31/19 RENEWAL DATE SYMBOLS & LEGEND SITE PLAN KEYNOTESSITE PLAN NOTES 1.PROJECT CONSTRUCTION SHALL NOT DISRUPT TRANSIT SERVICE OR PEDESTRIAN ACCESS TO TRANSIT STOPS. 2.ALL PROPERTY LINES, EASEMENTS AND BUILDINGS, BOTH EXISTING AND PROPOSED, ARE SHOWN ON THIS SITE PLAN. FIRE RISER ROLLED CURB TRASH ENCLOSURE - REFER TO SHEET A-260 CONCRETE PAD FOR TRASH ENCLOSURE KNOX BOX. LOCATION PER LOCAL FIRE AUTHORITY WALL MOUNTED FIRE ALARM ANNUNCIATOR PANEL FIRE DEPARTMENT CONNECTION GAS & WATER METERS - REFER TO PLUMBING PLANS BACKFLOW PREVENTION DEVICES - REFER TO CIVIL ENGINEERS PLANS MAINTENANCE GARAGE - REFER TO SHEET A-260 MODULAR WETLAND SYSTEM. REFER TO CIVIL ENGINEER PLANS PEDESTRIAN GATE - REFER TO LANDSCAPE PLANS EXISTING CMU SITE WALL - REFER TO CIVIL ENGINEER PLANS AREA TO BE KEPT CLEAR FOR VEHICLE SIGHT LINES TRANSFORMER VEHICLE ACCESS SLIDING GATE SECURITY GATE CALL BOX - REFER TO LANDSCAPE PLANS FIRE ALARM CONTROL UNIT PER OCFA REQUIREMENTS EXISTING SINGLE FAMILY RESIDENCE TYPE VB CONSTRUCTION 1 2 3 4 5 6 7 8 9 DISABLED ACCESS PATH OF TRAVEL - REFER TO CIVIL ENGINEERS PLANS FOR ADDITIONAL INFORMATION FIRE HYDRANT - REFER TO CIVIL ENGINEERS PLANS FOR ADDITIONAL INFORMATION ACCESSIBLE PARKING SPACES. FOR ALL REQUIREMENTS, INCLUDING SIGNAGE, REFER TO SHEET A-791 10 11 12 13 14 15 16 EV FUTURE ELECTRIC VEHICLE PARKING EXISTING PROPERTY LINE 17 FUTURE PROPERTY LINE - REFER TO CIVIL ENGINEER PLANS FOR ADDITIONAL INFORMATION 18 19 SCALE: 1/16"=1'-0"1SITE PLAN AD D I T I O N A L L O C K E R AD D I T I O N A L L O C K E R 17 C O M P A R T M E N T S 17 C O M P A R T M E N T S 37 1 0 D A - 1 0 ) L 9 B O ; E S 2 P A R C E L S 37 1 0 D A - 1 0 ) L 9 B O ; E S 2 P A R C E L S 37 1 0 D A - 1 0 ) L 9 B O ; E S 2 P A R C E L S 37 1 0 D A - 1 0 ) L 9 B O ; E S 2 P A R C E L S 37 1 0 D A - 1 0 ) L 9 B O ; E S 2 P A R C E L S 37 1 0 D A - 1 0 ) L 9 B O ; E S 2 P A R C E L S 37 1 0 D A - 1 0 ) L 9 B O ; E S 2 P A R C E L S 37 1 0 D A - 1 0 ) L 9 B O ; E S 2 P A R C E L S 37 1 0 D A - 1 0 ) L 9 B O ; E S 2 P A R C E L S )IRST LEVEL OVERALL BUILDING PLAN A-201 SCALE 18 1 -01)IRST LEVEL OVERALL BUILDING PLAN ComSany Address Phone No. ProMect Contact Email PrinciSal ProMect ManaJer ADC ProMect No Ryan Ratcliff rratcliff@adcollaborative.com Chris Weimholt laguna hills, ca 92653 www.adcollaborative.com 23231 south pointe drive 949.267.1660 SA N T A A N A V E T E R A N S V I L L A G E Client COP<RIGHT C 20160136 Sh e e t I s s X e D a t e Sh e e t I s s X e R e v i s i o n L o J 8- 7 - 2 0 1 8 1S T C I T < S U B M I T T A L 8 - 7 - 2 0 1 8 JAMBOREE HOUSING CORPORATION 17701 COWAN AVE, SUITE 200 IRVINE, CA 92614 949-263-8676 Ryan Ratcliff 33 1 4 W . ) I R S T S T SA N T A A N A , C A CHRISTOPHER WEIMHOLT No. C-32271 103119 RENEWAL DATE BUILDING PLAN KE<NOTES 1 2 3  6 7 8 9 10 11 12 13 BUILDING PLAN NOTES 1.WHERE IN)ORMATION IS UNCLEAR OR A CON)LICT IS )OUND, CONTRACTOR IS RESPONSIBLE )OR CONTACTING THE ARCHITECT PRIOR TO PROCEEDING. 2.DIMENSIONS INDICATED, U.N.O. ARE TO THE )ACE O) STUD, OR )ACE O) CONCRETE. E;TERIOR WALL STUDS ARE TO ALIGN WITH THE )ACE O) CONCRETE DIRECTL< BELOW U.N.O. 3.RE)ER TO SHEETS A-000 THRU A-02 )OR BUILDINGS OCCUPANT LOAD, E;ITING COMPLIANCE, TRAVEL DISTANCE, )IRE RATINGS AND ADDITIONAL IN)ORMATION NOT SHOWN. 4.RE)ER TO ENLARGED PLANS, WHERE APPLICABLE, )OR ADDITIONAL DIMENSIONS, NOTES AND IN)ORMATION NOT SHOWN. .SLOPE AT PATH O) TRAVEL MA< NOT E;CEED 14 PER )OOT IN AN< DIRECTION. RE)ER TO SHEET A-791 A-792 )OR DISABLED ACCESS RE4UIREMENTS 6.PENETRATIONS AT )IRE RATED ASSEMBLIES TO BE IN COMPLIANCE WITH THE C.B.C, CHAPTER 7. RE)ER TO )IRE RATED DETAILS ON SHEET A-711 A-712 )OR ADDITIONAL IN)ORMATION NOT SHOWN. 7.)IRE DAMPERS ARE TO BE INSTALLED IN COMPLIANCE WITH C.B.C. SECTION 717.6.2 WHERE PENETRATING THE )IRE RATED )LOORCEILING ASSEMBL<. 8.VERTICAL AND HORI=ONTAL )IRE BLOCKING TO COMPL< WITH C.B.C. SECTION 718.2 9.CONTRACTOR IS RESPONSIBLE )OR INSTALLATION O) ALL RE4UIRED ACCESS PANELS IN )LOORS AND CEILINGS. ACCESS PANELS ARE TO BE PRIMED AND PAINTED TO MATCH ADJACENT )INISH. WHERE PANELS PENETRATE )IRE RATED ASSEMBLIES, PANELS SHALL MEET THE RE4UIREMENTS IN C.B.C. SECTION 718. 8.)IRE E;TINGUISHER CABINETS SHALL BE LOCATED IN SUCH A MANNER AS TO NOT E;CEED 7 TRAVEL DISTANCE )ROM AN< POINT IN THE BUILDING. T<PE AND LOCATION AS RE4UIRED PER THE INTERNATIONAL )IRE CODE. 9.CONTRACTOR TO PROVIDE )URRING AS RE4UIRED TO MAINTAIN LEVEL AND PLUMB WALL, )LOOR AND CEILING )INISHES. 10.RE)ER TO THE BUILDING AND WALL SECTIONS )OR VERTICAL DIMENSIONS AND ADDITIONAL ASSEMBL< DETAILS. VERTICAL DIMENSIONS U.N.O. ARE TAKEN )ROM THE TOP O) )OUNDATION OR TOP O) STRUCTURAL SHEATHING. 11.RE)ER TO THE STRUCTURAL ENGINEERS PLANS )OR )RAMING MEMBER SI=ES, SPACING, RE4UIRED )ASTENING, HOLDDOWN-S<STEMS, AND SPECIAL INSPECTION RE4UIREMENTS. 12.RE)ER TO THE MECHANICAL ENGINEERS PLANS )OR LA<OUTS, HVAC ROUTING, ACOUSTICAL ISOLATION AND PENETRATIONS, E;HAUST TERMINATIONS AND SO))IT LA<OUTS 13.RE)ER TO THE ELECTRICAL ENGINEERS PLANS )OR E;IT SIGN LOCATIONS, )OOT-CANDLE LIGHTING COMPLIANCE AND OUTLET AND SWITCH MOUNTING HEIGHTS AND LOCATIONS. 14.RE)ER TO THE PLUMBING ENGINEERS PLANS )OR PIPE PENETRATION LOCATIONS, ACOUSTICAL ISOLATION, AND )IRE STOPPING INSTALLATION. 1.)OR ACCESSIBILIT< RE4UIREMENTS O) BUILDING ELEMENTS, RE)ER TO SHEETS A-790 THRU A-792 16.ASSISTIVE LISTENING S<STEMS RE4UIRED IN ASSEMBL< AREAS, CON)ERENCE AND MEETING ROOMS SHALL COMPL< WITH 2016 C.B.C. SECTION 11B-706. RE)ER TO A-793. )IRE RISER )IRE ALARM ANNUNCIATOR PANEL GAS METERS NOT USED E;TERIOR 3 DOWNSPOUT. DOWNSPOUT TO CONNECT INTO STORM S<STEM PER CIVIL. PRE-CAST CONCRETE PLANTERS 18;48;24 DROPPED HEADER OVERHEAD. RE)ER TO ELEVATIONS MOP SINK )LATWORK AT GROUND )LOOR PATIOS PER LANDSCAPE ARCHITECT 2A10BC )IRE E;TINGUISHER PER DETAIL 20A-710 PIPES )ROM ROO) DRAINS, ROO) DRAIN OVER)LOWS AND )ROM )LOOR DRAINS )ROM )LOORS ABOVE. )OR ADDITIONAL IN)ORMATION, RE)ER TO CIVIL AND PLUMBING DRAWINGS. PENETRATIONS THRU RATED ASSEMBLIES PER SHEETS A-710 THRU A-714 NOT USED AWNING, RE)ER TO E;TERIOR ELEVATIONS SHEET A-772 METAL RAILING, RE)ER TO DETAIL 11A-720 WALL MOUNTED ROO) ACCESS LADDER COLLECTOR HEAD AND OVER)LOW SCUPPER. CLASS A TPO ROO)ING B< )IRESTONE. 60 MIL ULTRAPL<, WHITE, CLASS A, ASTM E-108, UL-790. WITH A THREE-<EAR SUBCONTRACTOR GUARANTEE AND A MINIMUM 20-<EAR MANU)ACTURERS WARRANT<. 16 S<MBOLS LEGEND UNIT ;; ;;;; A-;;; UNIT T<PE  ROOM NAME UNIT ADDRESS  ROOM NUMBER SHEET NUMBER )OR ENLARGED PLAN 1-HOUR RATED WALL. RE)ER TO DETAILS ON SHEET A-710 1-HOUR RATED )IRE BARRIER AT STAIRWELLS AND OCCUPANC< SEPARATION. 0 STC PROVIDED TO MEET ACOUSTICAL RE4UIREMENT. RE)ER TO DETAIL 2A-710 )OR SINGLE WALL AND 3A-710 )OR DOUBLE STUD WALL 1-HOUR RATED PARTITION. 0 STC PROVIDED TO MEET ACOUSTICAL RE4UIREMENT. RE)ER TO DETAIL 2 OR 3A-710 1-HOUR RATED )IRE PARTITION AT CORRIDORDWELLING UNIT DWELLING UNITDWELLING UNIT. RE)ER TO DETAILS 13 OR 14 ON A-710 CONCRETE ROO) TILE B< EAGLE ROO)ING OR E4UAL. COLOR TO BE APPROVED B< ARCHITECT. 17 14 1 4 MU MOBILIT< UNIT. UNIT TO MEET RE4UIREMENTS O) CBC CHAPTER 11B CU COMMUNICATION UNIT. UNIT TO HAVE ASSISTED LISTENING ENHANCEMENTS AL COMMON AREA ROOM TO HAVE ASSISTED LISTENING DEVICES INSTALLED SECOND LEVEL OVERALL BUILDING PLAN A-202 SCALE: 1/8"=1'-0"1SECOND LEVEL OVERALL BUILDING PLAN Company: Address: Phone No. Project Contact: Email: Principal: Project Manager: ADC Project No: Ryan RatcliII rratcliII#adcollaEorative.com Chris Weimholt laguna hills, ca 92653 www.adcollaborative.com 23231 south pointe drive 949.267.1660 SA N T A A N A V E T E R A N S V I L L A G E Client COPYRIGHT C 20160136 Sh e e t I s s u e D a t e Sh e e t I s s u e & R e v i s i o n L o g 8- 7 - 2 0 1 8 1S T C I T Y S U B M I T T A L 8 - 7 - 2 0 1 8 JAMBOREE HOUSING CORPORATION 17701 COWAN AVE, SUITE 200 IRVINE, CA 92614 949-263-8676 Ryan RatcliII 33 1 4 W . F I R S T S T SA N T A A N A , C A CHRISTOPHER WEIMHOLT No. C-32271 10/31/19 RENEWAL DATE BUILDING PLAN KEYNOTES 1 2 3 5 6 7 8 9 10 11 12 13 BUILDING PLAN NOTES 1.WHERE INFORMATION IS UNCLEAR OR A CONFLICT IS FOUND, CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE ARCHITECT PRIOR TO PROCEEDING. 2.DIMENSIONS INDICATED, U.N.O. ARE TO THE FACE OF STUD, OR FACE OF CONCRETE. EXTERIOR WALL STUDS ARE TO ALIGN WITH THE FACE OF CONCRETE DIRECTLY BELOW U.N.O. 3.REFER TO SHEETS A-000 THRU A-025 FOR BUILDINGS OCCUPANT LOAD, EXITING COMPLIANCE, TRAVEL DISTANCE, FIRE RATINGS AND ADDITIONAL INFORMATION NOT SHOWN. 4.REFER TO ENLARGED PLANS, WHERE APPLICABLE, FOR ADDITIONAL DIMENSIONS, NOTES AND INFORMATION NOT SHOWN. 5.SLOPE AT PATH OF TRAVEL MAY NOT EXCEED 1/4" PER FOOT IN ANY DIRECTION. REFER TO SHEET A-791 & A-792 FOR DISABLED ACCESS REQUIREMENTS 6.PENETRATIONS AT FIRE RATED ASSEMBLIES TO BE IN COMPLIANCE WITH THE C.B.C, CHAPTER 7. REFER TO FIRE RATED DETAILS ON SHEET A-711 & A-712 FOR ADDITIONAL INFORMATION NOT SHOWN. 7.FIRE DAMPERS ARE TO BE INSTALLED IN COMPLIANCE WITH C.B.C. SECTION 717.6.2 WHERE PENETRATING THE FIRE RATED FLOOR/CEILING ASSEMBLY. 8.VERTICAL AND HORIZONTAL FIRE BLOCKING TO COMPLY WITH C.B.C. SECTION 718.2 9.CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ALL REQUIRED ACCESS PANELS IN FLOORS AND CEILINGS. ACCESS PANELS ARE TO BE PRIMED AND PAINTED TO MATCH ADJACENT FINISH. WHERE PANELS PENETRATE FIRE RATED ASSEMBLIES, PANELS SHALL MEET THE REQUIREMENTS IN C.B.C. SECTION 718. 8.FIRE EXTINGUISHER CABINETS SHALL BE LOCATED IN SUCH A MANNER AS TO NOT EXCEED 75' TRAVEL DISTANCE FROM ANY POINT IN THE BUILDING. TYPE AND LOCATION AS REQUIRED PER THE INTERNATIONAL FIRE CODE. 9.CONTRACTOR TO PROVIDE FURRING AS REQUIRED TO MAINTAIN LEVEL AND PLUMB WALL, FLOOR AND CEILING FINISHES. 10.REFER TO THE BUILDING AND WALL SECTIONS FOR VERTICAL DIMENSIONS AND ADDITIONAL ASSEMBLY DETAILS. VERTICAL DIMENSIONS U.N.O. ARE TAKEN FROM THE TOP OF FOUNDATION OR TOP OF STRUCTURAL SHEATHING. 11.REFER TO THE STRUCTURAL ENGINEERS PLANS FOR FRAMING MEMBER SIZES, SPACING, REQUIRED FASTENING, HOLDDOWN-SYSTEMS, AND SPECIAL INSPECTION REQUIREMENTS. 12.REFER TO THE MECHANICAL ENGINEERS PLANS FOR LAYOUTS, HVAC ROUTING, ACOUSTICAL ISOLATION AND PENETRATIONS, EXHAUST TERMINATIONS AND SOFFIT LAYOUTS 13.REFER TO THE ELECTRICAL ENGINEERS PLANS FOR EXIT SIGN LOCATIONS, FOOT-CANDLE LIGHTING COMPLIANCE AND OUTLET AND SWITCH MOUNTING HEIGHTS AND LOCATIONS. 14.REFER TO THE PLUMBING ENGINEERS PLANS FOR PIPE PENETRATION LOCATIONS, ACOUSTICAL ISOLATION, AND FIRE STOPPING INSTALLATION. 15.FOR ACCESSIBILITY REQUIREMENTS OF BUILDING ELEMENTS, REFER TO SHEETS A-790 THRU A-792 16.ASSISTIVE LISTENING SYSTEMS REQUIRED IN ASSEMBLY AREAS, CONFERENCE AND MEETING ROOMS SHALL COMPLY WITH 2016 C.B.C. SECTION 11B-706. REFER TO 5/A-793. FIRE RISER FIRE ALARM ANNUNCIATOR PANEL GAS METERS NOT USED EXTERIOR 3" DOWNSPOUT. DOWNSPOUT TO CONNECT INTO STORM SYSTEM PER CIVIL. PRE-CAST CONCRETE PLANTERS 18"X48"X24" DROPPED HEADER OVERHEAD. REFER TO ELEVATIONS MOP SINK FLATWORK AT GROUND FLOOR PATIOS PER LANDSCAPE ARCHITECT 2A:10BC FIRE EXTINGUISHER PER DETAIL 20/A-710 PIPES FROM ROOF DRAINS, ROOF DRAIN OVERFLOWS AND FROM FLOOR DRAINS FROM FLOORS ABOVE. FOR ADDITIONAL INFORMATION, REFER TO CIVIL AND PLUMBING DRAWINGS. PENETRATIONS THRU RATED ASSEMBLIES PER SHEETS A-710 THRU A-714 NOT USED AWNING, REFER TO EXTERIOR ELEVATIONS & SHEET A-772 METAL RAILING, REFER TO DETAIL 11/A-720 WALL MOUNTED ROOF ACCESS LADDER COLLECTOR HEAD AND OVERFLOW SCUPPER. CLASS A TPO ROOFING BY FIRESTONE. 60 MIL ULTRAPLY, WHITE, CLASS A, ASTM E-108, UL-790. WITH A THREE-YEAR SUBCONTRACTOR GUARANTEE AND A MINIMUM 20-YEAR MANUFACTURERS WARRANTY. 16 SYMBOLS & LEGEND UNIT XX XXXX A-XXX UNIT TYPE / ROOM NAME UNIT ADDRESS / ROOM NUMBER SHEET NUMBER FOR ENLARGED PLAN 1-HOUR RATED WALL. REFER TO DETAILS ON SHEET A-710 1-HOUR RATED FIRE BARRIER AT STAIRWELLS AND OCCUPANCY SEPARATION. 50 STC PROVIDED TO MEET ACOUSTICAL REQUIREMENT. REFER TO DETAIL 2/A-710 FOR SINGLE WALL AND 3/A-710 FOR DOUBLE STUD WALL 1-HOUR RATED PARTITION. 50 STC PROVIDED TO MEET ACOUSTICAL REQUIREMENT. REFER TO DETAIL 2 OR 3/A-710 1-HOUR RATED FIRE PARTITION AT CORRIDOR/DWELLING UNIT & DWELLING UNIT/DWELLING UNIT. REFER TO DETAILS 13 OR 14 ON A-710 CONCRETE ROOF TILE BY EAGLE ROOFING OR EQUAL. COLOR TO BE APPROVED BY ARCHITECT. 17 14 15 4 MU MOBILITY UNIT. UNIT TO MEET REQUIREMENTS OF CBC CHAPTER 11B CU COMMUNICATION UNIT. UNIT TO HAVE ASSISTED LISTENING ENHANCEMENTS AL COMMON AREA ROOM TO HAVE ASSISTED LISTENING DEVICES INSTALLED THIRD LEVEL OVERALL BUILDING PLAN A-203 SCALE: 1/8"=1'-0"1THIRD LEVEL OVERALL BUILDING PLAN Company: Address: Phone No. Project Contact: Email: Principal: Project Manager: ADC Project No: Ryan RatcliII rratcliII#adcollaEorative.com Chris Weimholt laguna hills, ca 92653 www.adcollaborative.com 23231 south pointe drive 949.267.1660 SA N T A A N A V E T E R A N S V I L L A G E Client COPYRIGHT C 20160136 Sh e e t I s s u e D a t e Sh e e t I s s u e & R e v i s i o n L o g 8- 7 - 2 0 1 8 1S T C I T Y S U B M I T T A L 8 - 7 - 2 0 1 8 JAMBOREE HOUSING CORPORATION 17701 COWAN AVE, SUITE 200 IRVINE, CA 92614 949-263-8676 Ryan RatcliII 33 1 4 W . F I R S T S T SA N T A A N A , C A CHRISTOPHER WEIMHOLT No. C-32271 10/31/19 RENEWAL DATE BUILDING PLAN KEYNOTES 1 2 3 5 6 7 8 9 10 11 12 13 BUILDING PLAN NOTES 1.WHERE INFORMATION IS UNCLEAR OR A CONFLICT IS FOUND, CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE ARCHITECT PRIOR TO PROCEEDING. 2.DIMENSIONS INDICATED, U.N.O. ARE TO THE FACE OF STUD, OR FACE OF CONCRETE. EXTERIOR WALL STUDS ARE TO ALIGN WITH THE FACE OF CONCRETE DIRECTLY BELOW U.N.O. 3.REFER TO SHEETS A-000 THRU A-025 FOR BUILDINGS OCCUPANT LOAD, EXITING COMPLIANCE, TRAVEL DISTANCE, FIRE RATINGS AND ADDITIONAL INFORMATION NOT SHOWN. 4.REFER TO ENLARGED PLANS, WHERE APPLICABLE, FOR ADDITIONAL DIMENSIONS, NOTES AND INFORMATION NOT SHOWN. 5.SLOPE AT PATH OF TRAVEL MAY NOT EXCEED 1/4" PER FOOT IN ANY DIRECTION. REFER TO SHEET A-791 & A-792 FOR DISABLED ACCESS REQUIREMENTS 6.PENETRATIONS AT FIRE RATED ASSEMBLIES TO BE IN COMPLIANCE WITH THE C.B.C, CHAPTER 7. REFER TO FIRE RATED DETAILS ON SHEET A-711 & A-712 FOR ADDITIONAL INFORMATION NOT SHOWN. 7.FIRE DAMPERS ARE TO BE INSTALLED IN COMPLIANCE WITH C.B.C. SECTION 717.6.2 WHERE PENETRATING THE FIRE RATED FLOOR/CEILING ASSEMBLY. 8.VERTICAL AND HORIZONTAL FIRE BLOCKING TO COMPLY WITH C.B.C. SECTION 718.2 9.CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ALL REQUIRED ACCESS PANELS IN FLOORS AND CEILINGS. ACCESS PANELS ARE TO BE PRIMED AND PAINTED TO MATCH ADJACENT FINISH. WHERE PANELS PENETRATE FIRE RATED ASSEMBLIES, PANELS SHALL MEET THE REQUIREMENTS IN C.B.C. SECTION 718. 8.FIRE EXTINGUISHER CABINETS SHALL BE LOCATED IN SUCH A MANNER AS TO NOT EXCEED 75' TRAVEL DISTANCE FROM ANY POINT IN THE BUILDING. TYPE AND LOCATION AS REQUIRED PER THE INTERNATIONAL FIRE CODE. 9.CONTRACTOR TO PROVIDE FURRING AS REQUIRED TO MAINTAIN LEVEL AND PLUMB WALL, FLOOR AND CEILING FINISHES. 10.REFER TO THE BUILDING AND WALL SECTIONS FOR VERTICAL DIMENSIONS AND ADDITIONAL ASSEMBLY DETAILS. VERTICAL DIMENSIONS U.N.O. ARE TAKEN FROM THE TOP OF FOUNDATION OR TOP OF STRUCTURAL SHEATHING. 11.REFER TO THE STRUCTURAL ENGINEERS PLANS FOR FRAMING MEMBER SIZES, SPACING, REQUIRED FASTENING, HOLDDOWN-SYSTEMS, AND SPECIAL INSPECTION REQUIREMENTS. 12.REFER TO THE MECHANICAL ENGINEERS PLANS FOR LAYOUTS, HVAC ROUTING, ACOUSTICAL ISOLATION AND PENETRATIONS, EXHAUST TERMINATIONS AND SOFFIT LAYOUTS 13.REFER TO THE ELECTRICAL ENGINEERS PLANS FOR EXIT SIGN LOCATIONS, FOOT-CANDLE LIGHTING COMPLIANCE AND OUTLET AND SWITCH MOUNTING HEIGHTS AND LOCATIONS. 14.REFER TO THE PLUMBING ENGINEERS PLANS FOR PIPE PENETRATION LOCATIONS, ACOUSTICAL ISOLATION, AND FIRE STOPPING INSTALLATION. 15.FOR ACCESSIBILITY REQUIREMENTS OF BUILDING ELEMENTS, REFER TO SHEETS A-790 THRU A-792 16.ASSISTIVE LISTENING SYSTEMS REQUIRED IN ASSEMBLY AREAS, CONFERENCE AND MEETING ROOMS SHALL COMPLY WITH 2016 C.B.C. SECTION 11B-706. REFER TO 5/A-793. FIRE RISER FIRE ALARM ANNUNCIATOR PANEL GAS METERS NOT USED EXTERIOR 3" DOWNSPOUT. DOWNSPOUT TO CONNECT INTO STORM SYSTEM PER CIVIL. PRE-CAST CONCRETE PLANTERS 18"X48"X24" DROPPED HEADER OVERHEAD. REFER TO ELEVATIONS MOP SINK FLATWORK AT GROUND FLOOR PATIOS PER LANDSCAPE ARCHITECT 2A:10BC FIRE EXTINGUISHER PER DETAIL 20/A-710 PIPES FROM ROOF DRAINS, ROOF DRAIN OVERFLOWS AND FROM FLOOR DRAINS FROM FLOORS ABOVE. FOR ADDITIONAL INFORMATION, REFER TO CIVIL AND PLUMBING DRAWINGS. PENETRATIONS THRU RATED ASSEMBLIES PER SHEETS A-710 THRU A-714 NOT USED AWNING, REFER TO EXTERIOR ELEVATIONS & SHEET A-772 METAL RAILING, REFER TO DETAIL 11/A-720 WALL MOUNTED ROOF ACCESS LADDER COLLECTOR HEAD AND OVERFLOW SCUPPER. CLASS A TPO ROOFING BY FIRESTONE. 60 MIL ULTRAPLY, WHITE, CLASS A, ASTM E-108, UL-790. WITH A THREE-YEAR SUBCONTRACTOR GUARANTEE AND A MINIMUM 20-YEAR MANUFACTURERS WARRANTY. 16 SYMBOLS & LEGEND UNIT XX XXXX A-XXX UNIT TYPE / ROOM NAME UNIT ADDRESS / ROOM NUMBER SHEET NUMBER FOR ENLARGED PLAN 1-HOUR RATED WALL. REFER TO DETAILS ON SHEET A-710 1-HOUR RATED FIRE BARRIER AT STAIRWELLS AND OCCUPANCY SEPARATION. 50 STC PROVIDED TO MEET ACOUSTICAL REQUIREMENT. REFER TO DETAIL 2/A-710 FOR SINGLE WALL AND 3/A-710 FOR DOUBLE STUD WALL 1-HOUR RATED PARTITION. 50 STC PROVIDED TO MEET ACOUSTICAL REQUIREMENT. REFER TO DETAIL 2 OR 3/A-710 1-HOUR RATED FIRE PARTITION AT CORRIDOR/DWELLING UNIT & DWELLING UNIT/DWELLING UNIT. REFER TO DETAILS 13 OR 14 ON A-710 CONCRETE ROOF TILE BY EAGLE ROOFING OR EQUAL. COLOR TO BE APPROVED BY ARCHITECT. 17 14 15 4 MU MOBILITY UNIT. UNIT TO MEET REQUIREMENTS OF CBC CHAPTER 11B CU COMMUNICATION UNIT. UNIT TO HAVE ASSISTED LISTENING ENHANCEMENTS AL COMMON AREA ROOM TO HAVE ASSISTED LISTENING DEVICES INSTALLED