Loading...
HomeMy WebLinkAbout20163390 - PermitCity of Santa Ana Permit Counter: (714) 647-5800 20 Civic Center Plaza (M-19), Santa Ana, CA92702 Electrical Permit #: 20{63390 Pin #: 9876{ l nspection Requests: (7 1 4\ 667 -?7 38 l nspector Section: (7 1 41 647 -5853 Project Address: 2552 N Valencia St Unit: Block: NA Bldg: Tract: 705 Address Range: Historic: No Suite Range: Zoning: Rl N4 Assessor'sParcel: 395.421-01 Lot: 45 & 57 Owner: Address: Mike O'valle 2552 Valencia Ave Santa Ana, CA 927061733 Fee Type Amount Ql)Fee Phone Tenant Name: Contractor Address: Boersman Construclion Cor 5433 Broderick Court Hemet, CA 92544 (9sl) 570-8706 PAID Phone JUN 0 S 201/ State Lic #: 994774 Lic Type: B Bus. Lic #: 35606.1 Workers' Compensation lnsurance Carrier: Exempt Policy #: Expires: $ City of Santa Ana Building Use: Job Type: Nature of Work: Single Family Dwelling Solar Solar Occupancy: Constr Type Codel R-3, U VB cEc 2016 Notes lnstall solar panels/fee pd on Planning Conditions: Planning Approval By Plan Checked By: Permit lssued By: Subject to Field: Building Permit #: $x"rn"no"., x"tny Date Date Date o6t09t2017 Account# Misc. Receipt: l\,lisc. Receipt: Misc. Receipt: Total Every permil issued sha become invalid unless tho wolr( o, lhe s/te authonzod by such pefinil is commenced within 180 days aller its issuance, ot if tl'€ wo* authonzed on the site by such permit is suspended ot abgndoned fot a poriod of 1 80 days atlet the tirfle the wo* is cofifiencod. lnspector MID#: 2017-136711 Fee Total: Paid to Date: Balanc6 Due: $0.00 $0.00 $0.00 APPROVALS DATE ID/SIG.COMMENTS Site-Work Underground Pole Bases Light Standards Spas, Pool, Fountains Signs (monument) Life Safety /Low Voltage Fire Alarm / Dampers Communications Cable Building Bonding / Grounding / UFER Transformers Torqueing Sub-Panels Air Conditioners Roof To p Equipment Factory Wired Unit Walls (Conduit) Walls (Rough) Ceilings (Hard & Soffit Rouoh Ceilings (T-Bar Rough) Meter Release Rough /t FINAL 6/tz /tt -+l<r47 Notes, Remarks, erc. -T -'T ELECTRICAL-INSPECTOR RECORD OWNET AUILDET DAT,CANATloN I hdrtt.ltm oid6 pdun, ol Fjlrr ln. I m.tnqt 86 dE Comrlotr tr.@ Lry fo, E lo!o*n8 lB,n (Saroll t Bcira !n Prof6hn Co&): Ary Cny or aou y which r.qui6 . Fnil lo 6dru.1, .t., ihFov., dsmlirh or lF.n Dy 3Iru.te Fhi ro ir. isue., .Lo r.q{iB thc +plicd tor such Fnir to lilc . !ho.d iliffir rhn lE or 3h. i lk@!d puBr,n lo llr FvirioN oa dE CmrdM r Li..N.d tr* (Cl'rp{d 9. Comning wnh Serion 7(m of Divirion I oa llE BBil6 ud Pftl6ioN (o<t )or rh.r lrstn. i d6rpr rlE6lE!d rlEtsir for rlE.lh.d dslvt i Aly vi,hrbn lfsdbn 70ll t t?ot .ppltd lor . F6i sbrd! tlE 4lkd ro..iril Fut, of @l lle Or ,iE tuid,rd dolLr (t500) .. I. s of,E oftlE FDFry. tr Dy c!ryLD6 wn,r *.96 s lh.n $b oB'FEnior witi & lli wsL !d IE Gr81c a d i drLd or otrald ao 3.1. (Se 7044. Bulin< od I'rrf6.io6 Cod. l lE Conrlcro t l-ic.@ L.* .106 mi .pply to u o"E of rh. FFly *ho hruror mF!6dE6( nnvho dEsxt s hiMlfo, h<*llor lleush hn n hd om dpk rd. F!ri,.n fid uh i,pm\qrE6 e El had.d dolH 6r s]. I( noM.llE hrildir{ or insoruEr i' DLl *alE o( yt 6f6rpl6be $. o'.E BolE win h.r dE h,&! of FornB dr lE d JE dil d lild d irgow dE F.Fiy 6r tlE F pnof l. a o*E of ih. FDFrr, m .rclBiv.lr codtuns *n[ [.d!.d codrdm ro .o.fud tlE FoFi lsc. ?04.1, llliB xd hDi!.i{ Cod. Th. Conr6ior'! Li.d. l-.u do6 ror q?ly ro d ownd of Fop6U *to build! or inprora rhao.. ud Rlb .o'rn ts for 3ut F.jat! $ith ! Co n ro(r) licaqt p6M lo rh. Conlreroir Lt@ bw) I m .ropl un& Sdirn Drt? Of,trfi sll3liEas:rcrfrlsarla! DECI Al.^'ft(rl I h6.hy dmnn undn pnElryolrEluryo..ofrh. n,llnv'ns d<lernrns -l h.E d sill did.n. Califtd. of CorEd ro Sdf-lNe lr *ut6 cuEdEri'q a EDviLd fo. b, sai61700 olrlE Ltor Codc tu tlE F6.l:]!E of llr wi ftr $tah lh. Fnn i! iqld I hrv..,td w l tuilnlin Nrld corpcru l'n itu!trc. 6 rarur.d by Salion 1700 of lh.lil,o. Co&. tot dE Ff6llre. of dE worl ld whkh lha pd.ir ir !&orl M, wortd snpsBnion iEurMcc 016 an FiLc, nuibf @: - l cql't lld r tlE Floffi of llE $o* lor *hth lhn Foit E e.n.l strllml mplor 6y lmn in &y nffi $ a ro b<omc rubjer lo lh. eltd .orFBnion hw ofc.lifomir -d .sc $n if I thoold b<oE rubjd lo th. worla.omFMriotrproeilioNoaselir.lT0oofrhcL$oCo{t,Irlull.fodhwnhcompltsiihlhoaFDltioB WARNIN(; I.ih,. ro s@ $ortd onFErFn drrsrsc i uLstuL !d .h.ll rubFt D dploF b din,ld F is di di n6 vp io oc hurhd rlh6.rd &'116 (t10o,000). in.ddnFn ro th. con of .onFMi!., tl.lr.eB 6 ForiH tu 'h.Sdion .t076 of rh. t bor Co&. ddd ed dlont,'*.{ Eteo.,tnnC \+a^rufii <rnirrt iiin Dt( trl{\ I to\ I h.r!r .ltm ur& Fdy or Fjury in I E U.a!.d u!& Foviin ol Clryld 9 (offiilB wnh Sanbn 7000) ot Dnaan 1 ol [r aui,E rd Pmf...d Cod.. r'd ny liqE i! n tul 6c tn.ffd ,".*..,- Cl0 Etecl.,eJ o.,., T*ne Q,10 tl .-,-o-, qqut778 \5*r" B"erlx"a- COISIIUIIIOIjJADTIE.dGEN(} I bolt' .rm !.<16 FuX, ol pqjlr, rhi rha. n . or!.rudb, knd's .8tr, lor rlE Ffr,'1e. of th. qtrt for $ith 'ht pahn i! i.su.d (Sc. 1097, Civ. C ). aItl.l(AdL[EClJaAUU! I hdtry.fm uid.r FElty of Fjury o* otiE rolhqins d.cl& ioN lLnohion Pmirs-Arbdlor Nor ific.r ion F.d6.l RquhrioN (Titl. 40. Pd6) - R.qun.d lnl6 oftLiificrbn I cd rt rh! rlE f.da.l rcsuld 68 rc8rdin3 6tdG rm1.l e Rn 4Dlk$L ro rh! F.F I cEl,fy rhd I lur. rdd rhs sppl(rr io. rd surr rhrl rhc rhovc i!tunnarn,n B corr<t I rg6 i{' .omply wir h .ll ( ir y ind ( ounl} ordinan.6 ed Srd. b$ rbri.8 n .oBrucri,)( ed ho.hy!urh.rr.rq'66bn6 olrhn ( il) dd (i)unlyb dl6 ur{n rh. alur n'.nrtr)Bl F)pcny for Doli...l o. ^161Sfrtlr ".*U*-..,rn*,, B r g'4 ao\n T\^/'lL \PI'? ",,., ju.'r'e QrlOlT I I I I Under Slab / Floor I I I Service Meter *-SNTA NA,Iffi Plan ning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www,santa-ana.org RES!DENTIAL PHOTOVOLTAIC CHECKLIST sol{1 cBc 2013 Solar Photovoltaic (PV) Checktist for Detached STNGLE FAMtLy RESIDENCES Onty lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of rwo sets of plans, of minimum 11" x 17' size. lf answerinq NO t o anv of the questions. olan ch eck shall be required Proj ect Address: }.5S )\Io..lenci o..SFree} /flcclh Contractor Company Name: Contractor License Number: l^/cs I Co,x+ G.EA 111 2 3 6 7 4 5 YES NO ZA trtr rza E tr ,da 7A ad ZA Are the following applicable to the proposed project? Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? Will the PV system be installed on a roof having only one roofing layer with no overlays? Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? Will the PV system weigh maximum 4 pounds per square feet or less? Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be installed with a space of 2" minimum to l0" maximum between the underside of modules and the surface of the roof? Will the PV system be installed wathout using any ballast system or counter-weight system? Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Will the minimum 5/16" lag screws be installed with a minimum ol 2-112 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, pV layout, anchorage spacing, anchorage details and manufacturer's PV support information.) 8 @tr Print Name: Phone Num Signaturei Oate: J 10 7a I certify under penalty of perjury under the laws of the state of california that the above is true ber Email Address: 1- t-1q er )o )..o i n ' Co r"'r Re! 1111912015 /A goo }-( n q 9. afix rn(, ,-t rno m?P =>()= O-t- '7 t-) jrn -im'T1PAP -lmz =(D c =- (o')14(D"io o I jd S -J,qJ=O_t' :r:r'rnr- .<alr!,_: - i =l ^3sEdilc =;ar @ = i;<:, oni-a@Fr J o) 1u * -c'-+:.!,r".n 6 d'a)A r-: o :lo)=(DrD o= i (, -.=Y=turX=(DlR*< o o-i l oX oI - -- I-ru =o I H =.o -.i -l X J :: =- - CI-Xor|,i'DNii-^ E &is I o-='<r'-r qq(,<-cDo=P6.) =JJ=md a v'i: -ml'-!Y =.8 o.o -*€ &6 E E(D: o:f *:, b.< : 'Do o!4< o3 -o! s i !1 r i: d; -ll--ol= < !u: X d o o =:.ri\j :r -: " - o.-:=oEL-o:" ='6du-o:-iosiiex-3ie-2s< -$-N=. 1"f = - (D < ;i roq9(/)rD'"(tf'or-.)ar=ftoJ! = o'" .- (,o 3,_:i1E1oo(DfxxoqrO-!'::=-.=- u i i:r-foiOo,o N .D al ,^ =' 'rgX; -'O9 PE;d ]pooC)-6;I;'rZ-; = rD _()oi2o=z-lno+oa1o-od'(^!f r r I; L_zOe={e;-i =-o> or:; d a { 3i -,a.ttrl:-r1.DoLo<Y - Lo -C.b ; i Ro'9iD."iixT\IiJ --o(, Laof o <h ^ -i j.e,A I kcip,9!b's o s-l 5llo< 6 i. c0 -3!+EHno'i 9,8 : -o ; (D - =r -AUO-r-l:X;rlE;i Q(D^d t e' \.1. *.$c {'i 1 .tt 7 a =U =: v o c 71'- -t 7 ov l-z - v I I I EXPEDITED PERMTT PROCESS FOR SMALL-SCALE PV SYSTEMS MtCRo.INVERTER The in[ormation in rhis guideline is intended to help local jurisdictions and contractors identify when PV syslem installarions are simple, needing only a basic review and when an installarion is more complex It is likely that 50%-75% of all resrdential syslems will comply wirh these simple criteria. For projects rhat fail to meet the simple criteria, resolution steps have been suggesred ro provide as a parh to permit aPproval. Required InJormation Jor Pennit: l. Site plan showing locarion of major componenrs on rhe property. This drawing need no( be exactly ao scale, but rt should represent relative location of componenrs ar sire (see supplied example sile plan) PV arrays on dwellings wirh a S perimerer space at ridge and sides may not need separate 6re service review 2. Elecrrical diagram showing PV array configurarion, wiring sysrem. overcurrenr prorectron. inverter, drsconnects. required signs. and ac connection ro building (see supplied standard electrical diagram) 3. Specihcarion sheers and insallarion manuals (if available) For all manufactured componenls including, but not limited ro, Pv modules, inverter(s), combiner box. disconnects. and mounting system. Step 1 : Structural Re"iew o[ PV Array Mounting System Is the array to be mounted on a defined, permitted roof sfiucture? Eyes !no IJ No due to non-compliant tooJ or a gound mount. submi completed worksheet Jor the structure WKSI RooJ Infonnation: l. Is rhe roofing rype lighrweighr (Yes = composition. lightweight masonry, meral, erc Composilion Mounting System I nJormalion: l. ls rhe mounting structure an benearh the module frames? IJ No, submtt completed worksheet jor rooJ strucrure wxsl lNo = heav! masonry, slate, etc. ) 2. Does rhe roof have a single roof covering? Eyes Er'lo IJ No, submit completed worksheetJor rooJ structwe wKSl. f Provide method and rype of wearherproohng roof penetrations (e.g. Rashing. caulk)Flashing en ineered producr desrgned ro mount PV modules wirh no more than an t8' gap Yes ! trto If No, provide details oJ sttuctural attachmettt certified by a design proJessional 2. For manufactured mounting systems. hll ou( information on the mounting sysrem below a. Mounring System [.'lanufacturer lronridge Product Name and vlodel# xR10 b. Toral Weighr of PV Modules and Rails 876 lbs c. Toral Number of Arrachmenr Poinrs d. Werghr per ArEchmenr Poinr (b = c) 33'69 lbs (if grearer rhan 45 lbs. see wKs I ) N4aximum Spacing Berween Artachmenr Poinrs on a Ra maximum spacing allowed based on maximum design t72 inches (see producr manual For Toral Surface Area of Pv Modules (square feer)292 wind speed) fu: DisLributed Weight of PV Nlodule on Roof (b +3 lbs/tu: IJ distributed v)eight oJ the Pv system is greater than 5 lbstf , see WNS L Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apPly; l. PV modules, uriliry-interactive inverrers, and combiner boxes are identifred for use in PV systems 2. The PV array is composed of 4 series strings or less per inverter. J. The roral inverrer capacity has a continuous ac power outpu! 13,440 walts or less 4. The ac inLerconnecrion point is on the load side of service disconnecting means (690 64(B)). 5. One of rhe srandard electrical diagrams (El.l, El Ia. El.lb. or El.lc) can be used to accurarely represent the PV system. lnteractive PDF diagrams are available at u"!vw.solarabcs.org/pernlitting Fill oLtt tht standard electricol Lliagram completeb). A guidc to the clectricul diqgrdtn is provided to help thr: tlpplicatlt wvlerstald each blunk to lll in. U the elech'icul systetn is more compler thatt thc stundard electri(dl d[agr m con effectiveb cotnnruticate. provtde an allernatire diagrdm witll appropriate detuil 2 ExtEDlrED IERI1II |R()C[S5 l()R fv syttE\ti -,\1lCR(]. lNVl llltR r. Site Plan for Small-Scale, Single-Phase PV Systems Site Name:@{Ed$se! Site Address: eur{ System AC Size . r:l -irtli (E) ?oia .lsP It 0,S|0UNEir E\rOY -Cil CEl.'Et t 12. r .tl lrtlll - i?.i' ilt 2rr' ' Itl P i?l. t N15 c UcI I a - MICRO, I NVEITT'ER SITE I'LAN lt I itSIJ I IY I M ICRO_ I NVI] RTE R E LI.CTRICAL D IAC RAM One-Line Standard Electrical Diagram for Micro-lnverter PV Systems Cdrrts xtr,rdd- rd PndE Sile Add.ess: System AC Size: . Sile Name N'IS o EQUIPMENT SCHEDUTE TAG 1 2 3 5 6 1 8 OESCRIPTION PV OC or AC MODULE DC/AC TNVERTER {MTCRO) J.BOX (IF USED) AC COMB PANEL (IF USED) GEN MEIER (IF USED) AC DTSCONNECf {rF USED) SERVICE PANEL PART NUMBER NO T ES UTILITY SERVICE SEE GUIDE APPENOIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING MICRO-INVERTERS IN ERANCH. CIRCUIT BUILDING GROUNDING ELECTRODEMICRO,INVERIERS IN ARANCH- CIRCUIT l--- FOR UNUSED MODULES PUT 'N/A' rn BLANK ASOV€ A CONDUIT ANO CONDUCTOA 5CHTOULE DESCRIPTION OR CONOUCIOR TYPE CONO . GAUGE USE.2 E or PV '{lRE E MFG GEC O EGC D XALLTHATAPPLY EXTERIOR CAELE LISTEO W/ INV MFG THWN-2 or XHHW-2 O orRHW-2O GEC D EGC E X ALL THAT APPLY NO DC GEC IF 690 35 SYSTEM IHWN"2 E or XHHW-2 D or RHW-2 D 3 GEC O EGC tr X ALL THAf APPLY BquqEI' or I CoNDUCTORS I MFG Cable ] ,""c^B,r ]*"",:":1. FI ry:e. CONOUIT TYPE SAME CONDUII SIZE SAME 5 MO0 MO{)MO0 DC DC DC ac Drsco t-80x )ocP INVIRTEq ocPo B-.--: MOO U J DC OC DC SAME SAME .l ! Uocc- F 3 F a 1 2 M II I AA A A 2 l t" i I i I I Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Addrd ..d Phdr Site Name eMFEwur Site Address: System AC Size: . N15 Dale 06.09 17 SIGNS sEE GUIDE SECTION 7 NOTES FOR AI L DRAW'NGS SIGN FOR DC DISCONNTCIPv MODULE RATINGS @ STC (Gurde Section 5) I OCPD " OVERCURRENT PROTECTION DEVICE MoourE MAxE Canadian Solar No sign necessary since 690.51 markrng on PV module covors needed informationMOOUTE MOOEL CS6P.26OP NATIoNAL ELEcTRIcAL coDE. REFERENcES sHowN As /rvEc xxx.xx) MAX POWER.POINT CURRENT (IMP)8.56 30.4MAX POWER.POINT VOL'TAGE (VP) OPEN.CIRCUIT VOLTAGE (Vd)37.5 9.1 2 15A 260 INVERTER RATINGS (Guide Sectlon 4) TNVERTEn MAXE Enphasg TNvERTERMoDTL M25O-50-2LL-S22 l MAx oc voLT RATTNG 48 l MAx PowER @ 4ooc L0 l NoMTNAL Ac votrAGE 240 SIGN FOR INVERTIR OCPD AND AC DrscoNNECr (rF ustD) SOLAR PV SYSTEM AC POINT OF CONNECTION SHoRT,CtRCUtT CURRENT (r{) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PM) MAX VOLTAGE (TYP 6OOVM) AC OUTPUT CURRINT NOMINAI AC VOLTAGT 18 18 600 THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR)voc TtMP coEr F hvfcn or .^rc nr 145*l IF COEFF SUPPLIEO, CIRCLE UNITS i MAX AC CURRENT MAX OCPD RATING 1 0 0 NOTES FOR ARRAY CIRCUII WIRING (Guide Secllon 6 and 8 anc, Appendix E)NOTES FOR INVERTER CIRCUITS {Guide Seclion 8 and 9) 1,) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME ORY AULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION IOCATION LOWEST EXPECIEO AMEIENT TEMP 3I 'C 1) IF UTILITY REOUIRES A VISIBLE,BREAK SWITCH, DOES fHIS SWITCH MEET THE REOUIREMENT? YESO NOO N/AE 2) IF GENERATION METER REQUIRED, DOES THIS MEIER SOCKET MEET THE REOUIREMENT" YES tr NO f] N/A E2 ) HIGIIEST CONTINUOUS AMBIENT TEMPERATURE EASED ON ASHRAE HIGHEST MONTH 2% DRY AULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION, HiGHEST CONTINUOUS TEMPERAIURE 53 'C 2.} 2OO9 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED4rC tN rHE UNTTED STATES (PALM SPRTNGS, CA tS 44.1'C). FOR LESS THAN I CURRENT-CARRYING CONDUCTORS IN ROOF.MOUNTED SUNLIT CONDUIT AT LEAST O 5" ABOVE ROOF AND USING fHE OUIDOOR DESIGN TEMPERATURE OF 476C OR LESS (ALL OF UNITED SIATES) a) 12 AWG, gOOC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH lsc OF 7.68 AMPS OR LESS WHEN PROIECTED BY A 12,AMP OR SMALLER FUSE b) 1O AWG, gOOC CONOUCTORS ARE GENERALLY ACCEPIABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 1s.AMP OR SMALLER FUSE 3I SIZE PHOTOVOLTAIC POWTR SOURCE (DC) CONDUCTORS AASED ON II,AX CURRfNT ON NEC 690 53 SIGN OR OCPD RATING AT DISCONNTCT 4)SIZE INVERTER OUTPUT CIRCUIT (AC)CONDUCTORS ACCOROING TO INVERTER OCPD AMPERE RATING. (36€ Gude Seclion 9) 5) TOTAL OF -L INVERIER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO. INVERTER CIICUTT DoES ToTAL SUPPLY EREAKEFS coMPLY wITH 120% EUSBAR EXCEPTION lN 690.64(BX2)(e)7 YESE NOO NOTES FOR MICRO-INVERTIR ELECTRICAL DIACRAM c U a- ;, I I I