Loading...
HomeMy WebLinkAbout20163247 - Permitt City of Santa Ana Permit Counter: (714], 647-5800 20 Civic Center Plaza (M-19), Santa Ana, C492702 Electrical Permit #: 211163247 Pin #: 7O2A1 l n spection Req uests: (7 1 41 667 -27 38 l nspector Section: (7 1 41 647 -5853 Project Address: 2021 N Millwood St Unit: Block: NA Bldg: Tract: 3902 Address Range: Historic: No Suite Range: Zoning: RlAssesso/sParcel: 396-041-36 Lot 81 Steven G Sloma 2021 N Millwood St Santa Ana, CA 927057619 (714) 5s8-9197 Fse Type Amount Qtr.,Fee Phone Tenant Name Contractor Address: Green Conception lnc 263 W Olive, #313 Burbank, CA 91502 (818) 319-0900 State Lic #: 964965 Lic Type: B Bus. Lic #: 365800 Workers' Compensation lnsurance: Carrier: Stato Fund Policy #: 9077985 Expires: 1110512017 Building Use: Job Type: Nature of Work: Single Family Dwelling Solar Solar Panels Occupancy: Constr Type Code: R.3, U VB cEc 20i6 Notes.lnstall pv roof mounted solar. Per Expedited Permit Process For Small Scale PV Systems Standard String System. Fees paid on BP fl0193059. Planning Conditio0s: Planning Approval By Date Date Date Misc. Receipt: Misc. Receipt: Misc. Receipt: Total Plan Checked By Permit lssued By Subject to Field: Building Permit # , Teri o5t23t2017 Account# 93059 $0.00 $0.00 90.00 Every permit issued shall becofie invalid unless the wo* on the site aulhodzed by such peinil is conmenced wilhin 180 days atlet ils issuance, or if the wod< aulhonzod on the site by such pemit ts suspended ot ebandoned lor a peiod ot 180 days aftet the time the work is cofifiatrced. lnspector MtD#. 2017-136325 Fee Total: Paid to Date: Balance Duo: Owner: Address: Phone ELECTHICAL.INSPECTOR RECORD APPROVALS DATE COMMENTS Site-Work Underground Pole Bases Light Standards Spas, Pool, Fountains Signs (monument) Life Safety /Low Voltaqe Fire Alarm / Dampers Communications Cable Building Under Slab / Floor Bonding / Grounding / UFER Transformers Torqueinq Sub-Panels Air Conditioners Roof Top Equipment Factory Wired Unit Walls (Conduit) Walls (Bouqh) Ceilings (Hard & Solfit Rouqh Ceilings (T-Bar Rough) lvleter Release Rough \\l\\af!\FINAL r1\ 11 Notes Remarks, Etc (n\NlRl|t Dt.R Dt I ( 1lr\rXrN lrtrjn!\\ .tr lrLit\.i{,((!r,, nl,rh r.,]tu,.., t\ ,l',, n1t,,,,, ,r ,.r r I r(Nt ) x' Jfrlnrr tr,.' ( '\,lrn,,lr\.,1 ._1.n\ nlN,nrh |inF .,r ,rrn{Jl'\,L.{(hnr!.ixrrhr !'l 1,r trrN rrr.\rll,I'rl id!1itrl ,xoll.rrlr,x! lS,rTrnl.lln{'ra.r'xll','n.\\itrN(ixli'llr'Ii".',rrr\l. N'liN'i,y kii{ln\r,,',,$Nol rh(nn'[rrttrh,hnli(irn,tr$rlFs{rdrl\h,,1$nrh\'{thi'n\!llo,lr1\.llorrno,:r I slrt dnirnhn{lrhF!'}\i1\nhr(i{nriRtNrrrL.mrlI['{'xtrrL,rlr'rirrt,iti.lrrr!'l tl l,trr.u,'ti n r[, S.Lrir, 1lllah[ll-lQltllili$flrrLIr(I.rf,^lIQ! IlEcht!llnnrtr .' tuulltoll{'r,tr!'rorrlk l',11"{n'r!l(\h'xr(,tr I hr\r ftl Nll rtr')rrn rtilrn rri, t ,x!1..l(r rlr tur,trnukr "1 l h$r 'rl$illnLUdrr$n't.'a Ld$rn.ixtrr i'tror,nr. r. 't,ttrtr.,|1'r \r,rrar rTrtr, rrxl.'lr rlFsorkl,rtrhllrrh^tf,'ntrrr!ia{ial I\!) r'ilr,\.ontil'\,rrn' n^uxfi. i.n'i1 rrF,ri\ nntr'li 1,, L{ ll' |. l[(nENof \t r\r,h.{ r{!b\rn,rlrtro'l,ti.'DtrrNni L'tr.d1'illi trL' irliul rhi.irl.L{'lll\\!nn'!'l'rrrr,rrr f,ot.^.ontrnr(itr,|h Ni,h.lS(ar;r' lrlrtslrlr.] -'lii (irL'.l.lull. nnrl's ih,,tr,t'1, \ 'r' rh,\ tr{Fl trrr .r,,ir nrl)r.r .,,.,tr1,r,,\.r i,,,trntr,,1 \tril rnk\ ntt r' o.r. h"'rtt1l rLtr'\ il ,Lnh,r r\li ..r^r or rrr'trn\, ({ ,l s(r0 krxr !,trh.lxr!tr rixlr ,\t!t,t.t(,r\1. t)t,t(J.,\[ \ I tul llrd\xrntrrrtrlr.r ti r!l\ ({ t\rrtr\ lrx L,rrrk, r,,ll{rrr,L'r. r,r Ira'r,lnrid lr1fl r. \l{nLn N, i't. r' I InlLl.Ll Rn ' I lnrt,r'r,l I Lrnl L'l Nri'ln n, ' l L.d \ rhi rli.r,'1.r,'lnptrl.nn'n. kr 'ltr'!r.l\\rN rlr. 'rn rfitlixt r, rhn trtfrr hn{'r,lrnri,rnrl{.rhrrlk, l,r..n'.Lr'1,1\\ili,llr{\ r(i'Dnry tIi.r* r, l{itl0! 1,{r{'rrtirrll:\ff:lriil ^,,,,,,,.,,,l\2'",,,,',,Rn kbwslra;,-"" osfz ;l;r ID/SIG. Service lr/eter EXPEDITED I'ERMIT I'ROCESs FOR SMALL-SCALE PV SYSTEMS The informarion in rhis guideline ,, ,",."0":n:o:ll jr:l are simple. needing only a basic review and when an installarion ident ify lonS mo p lex is li ly en t ial systems will comply wirh rhese simple criteria. For projec(s rhat fail suggested ro provide as a path ro permir approval. Required Information Jot Pennit: ee e e occ, Srte plan showing locarion of malor componenrs on (he should represent relarive locar,on of components at site rt Thrs rawln n iI with a i perimerer space ar ridge and sides may nor n Electrical diagram showing PV array coniguration. wiri required signs. and ac connecrion ro building (see supp Specification sheets and installarion manuals (if availab) limited ro. PV modules. inverrer(s). combiner box. dis Step 1 : Structural Review o[ PV Array Mounting Syste ls the array to be mounted on a defined, permitted roof IJ No due to non-comphant rcoJ or a ground mount. submtt compl d-ry4,iq:.Pat+.ur?H6u6.1 yFs |to, Roof InJonrution: l. ls (he roonng rype lighrweighr (Yes = composirion. lighrweighr masonry, meral, erc '' l.l a) Yes-Compositioh- IJ No, submit completed worksheet for roo.f structure WKSl = heavy mq.sonry, slate, etc...) 2. Does the roof have a single rooi covering? Eyes E no U No, submit completed worksheet Jor roof stucture WKSI. l. Provide method and type of weatherproohng roof penerrarions (e.g. nashing, caulk)Everest Flashing, M-1 Sealant M ounfing Sy st em Informtti on : l. ls the mounting structure an elgrneered producr designed ro mounr PV modules wirh noJnore rhan an l8" gap benearh rhe module frames? 14 yes lJ no If No, provide d.etails oJ stuctural attachment certiled by a design prokssional. 2. For manufactured mounting systems, hll out information on the mounring system below: a. Mounting Sysrem Manufacrure . Everest producr Name and yo6g13 Crossrail 48-S, Mill b. Total Weight of PV Modules and Rails 1652 bs c. Toral Number of Attachment Poinrs65 d e Weight per Artachmenr Polnr (b - c)25.4 bs (if greater than 45 lbs. see WKS I ) Maximum Spacing Berween Arrachmenr Poinrs on a Rail 48 nches (see product manual for maximum spacing allowed based on maximum design wind speed) f. g Total SurFace Area of PV Modules (square [eet)628 fr' Disrributed Weighr oF PV Module on Roof (b - D 2.63 lbsi ft' II distributed weight o! the Pv system is greatet than 5 lbs/ff , see wKSl . Step 2: Electrical Review o[ PV System (Calculations lor Electrical Diasram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, ulility-interactive inverters, and combiner boxes are idenrihed tor use in PV systems. 2. The PV array is composed of 4 series srrings or less per inverter. 3. The toral inverter capacity has a continuous ac power outpur 1f.440 Watrs or less 4. The ac interconnecrion point is on the load side of service disconnecting means (690.64(8)). 5. qle ofthe standard electrical diagrams (E I . t , E I . I a. E L I b. or E L I c) can be used ro accurarely represenr rhe PV sysrem. Interactive PDF diagrams are available at www.solarabcs.org/perrnitting. Fill out the standard electrical diagram completeb,. A guide to the electrical diagram is provided to help the applicant understand each blank tolll in. lf the electical system is more complex than the standard electrical diagram can elfectivell communicate, provide an a|ernotive diagram with appropriate detail 2 EXNEDITED I)TRMIT IROCTSS TOR PV SYSTEMS em. overcur Y6S re vG3 to ffiffi Site Plan for Small-Scale, Single-Phase PV Systems 4O9lrvin9 Dr Site Address: 2o2r M irwood st saota Site Name: steve Sroma .-^', ,ose Villalvazo 3 CANADIAN SOLAR CSU , 34OM MODULES IN 2 SERIES STRINGS OF 15 MODULES ON EXISTING ROOF STRUCTURE RE INVERTER WITH SUPPLIED COMAINER, OC OIsCONNECT AND AC OISCONNECT 4O.AMP PV AREA(ER IN MSP ]/4 EMT ON ROOF FXISTING FENCE 13 CANADIAN SOLAR CSU . 34OM MODULES IN 2 SERIES STRINGS OF 15 MODULES ON EXISTING ROOF STRUCTURE 8 CANADIAN SOLAR CSU 34OIt4 MODULES IN 2 SERIES STRINGS OF 15 MODULES ON EXISTING ROOF STRUCTURE llr ROOFTOPj-BOX IO IBANSITION EXPOSED USE 2 TO THWN.2 CONOUCTORsIN ]/4" EMT t N 6 CANADIAN SOLAR CSU. 34OM I.4ODULES lN 2 SERIES STRINGS OF 1 N4ODULES ON EXISTING ROOF STRU 5.3' INV AC t4sP 35.3' rRt JB 22.4', ]B ]B 8.6', 3 l8 3 \ \ POOL STANDAI{D STRING SysTTm S E PTAN F a- d. Uoca-t d. a- f-- o System AC Sizei 9 164 \ One-Line Standard Electrical Diagram for Small-Scale, Single-Phase PV Systems Site AddreSS 2021 M,llwood si santa ana cA92705 Site Name: sre"e sro",a 9164System AC Size o,*" 3, Jose Villalvazo NI5 o IQUIPMENTSCHTOULE l 1 2 3 5 6 7 8 9 DESCRIPTION isoun pv Lroourp J.BOX (IF USED) coMBTNER (rF USED) DC DISCONNECT l DC/AC INVERTER GEN METER (IF USEO) AC DISCONNECT (IF USED) SERVICE PANEL PART NUMBER I ]s'J - 340M -l']]a .6OOV, NEMA 3R ,seooou. rzo sE7600A.US DU222RA NOTES ARRAY tS 2 STRTNGS W|TH 1S UOOUTeS pen SenrrS Srnrr,rC 61616 NEMA lR JUC IO,! aox WllH POLARIS CONNLCIORS I INTEGRAiEDWTI] INVERTER 6OOVOC 45A SOLAREDGE WITI.] INIEGRATEO OC OISCONNECI ANO RAPIO SHUTDOWN UTILITY SERVICE SWITCII NO-I FUSIBLE 2'IOVAC 60A NEMA3R 2.o tAC, 2oo AMA|N, 2oo ABUS, 40 A TNVERTER OCPO (SEE NOTE 5 FOR INVERTER OCPDS, ALSO SEE GUIoE SECTION 9) Oisregard if provided with inverter FOR UNUSED SERIES STRINGS PUT'N/A" in BLANK ABOVE SEE GUIDE APPENDIX C FOR INFORI\.,IATION ON MODULE AND ARRAY GROUNDING A CONDUIT AND CONOUCTOR SCHt DUIE TAG DESCRIPTION OR CONDUCTOR TYPE COND, GAUGE NUMEER OF CONDUIT L"r. I CONDUIT srzl N/4 t!4 x14' N/A N/A 3!4' 114', 34' CONDUCTORS 1 USE-2 E or PV WIRE E , BARE COPPER EQ, GRD, COND, (EGC) 2 THWN-2 E or XHHW-2 tr or RHw-2 tr 3 THWN-2 E or XHHW-2 E or RHW-2 E INSULATED EGC 4 OC GROUNOING ELECTROOE COND, s THWN-2 E or XHHW-2 tr or RHw-2 E INSULATED EGC 81i./9 8 8 2-B 2-R,2'8. I'G 1.GREEN l GREEN EMT EMT EM'I EMT 15 uoouLes tN SERtES SOURCE-CtRCUtr. srntes so MODULES rN I URCE-CIRCUII r AC 0rscooc orsco sEnres souace-crncurr I MOOI.JLES IN I )ocP INVTRTER OCPD MOOULES IN 'se-ntsssouace-ctncur! ffiffi EIIIEE EIltr STANDARD STRING SYSTEM ELEC'TRICAL DIACRAM : - Uod t-- d ._ c F c it 1 A \A A A BUILDING GROUNDING ELECTRODE Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Address: Site Name: "-..-' sys tem AC Size: ... nam Ey Jose Villalvazo srzF NTS Date PV MODULE RATINGS @ STC (Guide Section 5) MoouLE MAKE Canadian Solar I MoDULE MooEL CSU - 340M MAX POWER.POINI CURRENT (IUP) MAX POWER.POINT VOLTAGE (V P) oPEN-CtRCUtT VOLTAGE (Voc) sHoRT-CtRCUtr CURRENT (rsc) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMA) MAX VOLTAGE (TYP 6OOVM) VOc TEMP CoEFF (mV/oCfl or %/oC E) IF COEFF SUPPLIED, CIRCLE UNITS NOTES FOR ALL DRAWINGS OCPD = oVERCURRENT PROTECTIoN DEVICE NAIIONAL ELECTRICAL CODE! REFERENCES sHowN AS r ,iEC XXX XX) INVERTE R RAr INGS (Gu,de Secl,on 4) TNVERTERMAKE iSolarr4ge TNVERTERMoDEL SE760OA-US SIGNS_SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT PHOIOVOLTAIC POWER SOURCE *oruo ,", "r*ce", t 17 .94 al RATED MPPvoLTAGE 530 v laax svsreu vortece 567 v MAx crRcurr cuRRENT 22.42 A WARNING: ELECTRICAL SHOCK HAZARD LINE AND LOAD MAY BE ENERGI2ED IN OPEN POSITION 9.48 A lsz.g v 1.46.2 v 8.97 A '15 A 340 w irooo v L - 31 MAX DC VOIT RATING MAX POWER @ 40.C NOMINAL AC VOLIAGE MAX AC CURRENT MAX OCPD RATING 500 v 7630 w 24O v t4O A SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) SOLAR PV SYSTEM AC POINT OF CONNECTION lc outeut cuanelrr 32 1,) LOWEST EXPECT AMAIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEI\,{PERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION LOWEST EXPECTEO AMAIENT TEMP OC 2 ) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2"/" DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCAIION. HIGHEST CONTINUOUS IEMPERATURE }, OC 2,) 2OO5 ASHRAE FUNOEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED STATES (PALM SPRINGS CAIS44,'I'C) FORLESSTHAN9 CURRENT.CARRYING CONOUCTORS IN ROOF.MOUNTEO SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR OESIGN TEMPERATURE OF 47"C OR LESS (ALL OF UNTTED STATES). a)1 FUSE b)1 2 AWG, gO"C CONDUCTORS ARE GENERALLY ACCEPTAALE FOR MODULES lsc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER O AWG, gOOC CONDUCTORS ARE GENERALLY ACCEPTAALE FOR MOOULES Isc OF 9 6 AMPS OR LESS WHEN PROTECTED BY A 15'AI\,1P OR SMALLER THIS PANEL FEO BY MULTIPLE SOURCES (UTILITY AND SOLAR) NOTES FOR INVERTER CIRCUITS (GUIde Seclion 8 and 9) 1) IF UTILITY REOUIRES A VISIALE.BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YESL NOtr N/A EI 2)IF GENERATION METER REOUIRED, DOES IHIS METER SOCKET MEET THE REOUIREMENT? YES tr NO tr N/A D 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC)CONDUCTORS BASED ON MAX CURRENT ON NEC 690,53 SIGN OR OCPD RATING AT DISCONNECI 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (Se€ Guids Section 9) s)ToTAL oF , INVERTER OCPO(S), oNE FoR EACH INVERTER. oOES TOTAL SUPPLY BREA(ERS CoMPLY wlIH 120% BUSBAR EXCEPTIoN lN 690.64(8X2Xa)? YES E NOtr NOTES FOR ARRAY CIRCUIT WIRING (Gurde Seclion 6 and I and Appendrx D) FUSE NOMINAL AC VOLTAGE 240 v NOTES FOR STANDAITD STRING SYSTEM ELECTRICAL DIAGRAM : t- o Uod F :cl Lc