Loading...
HomeMy WebLinkAbout20163721 - PermitCity of Santa Ana Permlt Counter: (714) 647-5800 20 Civic Center Plaza (M-19), Santa Ana, CA9270?Electrical Permit #: 2(J1li3721 Pin #: 1lJ142lnspection Requests: (7 14], 667-27 38 lnspector Section: (714) 647-5853 Project Address: 2225 W Hemlock Way Unit: Block: NA Bldg: Tract: 8344 Address Range: Historic: No Suile Range: Zoning: RlLot: 48 Gilben Bailey 2225 W Hemlock Way Santa Ana, CA 927046024 (714) 557-8989 Feo Type 0'1116002 51600 General Plan Update Amount 21 .25 Qty 0.00 Fee $0.00 Phone Tenant Name: Contraclor Address: Semper Solaris 1637 Tierra Montanosa ALPINE, CA 91901 (323) 3s9-0424 State Lic #: 978152 Lic Type: B, C-10, C-39, C{6 8us. Lic #: 365759 Workers' Compensation lnsurance: Carrier: State Fund Policy #: 9029275 Expires: 1011012017 Building Use: Job Type: Nalure of Work Single Famlly Dwelling Solar Solar Occupancy: Constr Type Code: R-3, U VB cEc 2016 Notes lnstall(14) roof mounted solar panels. FEES PO ON 't 0193563 Planning Conditions: Planning Approval By:Date Date Date Misc. Receipt: Misc. Receipl: Misc. Receipl: Total Plan Checked Byl Permit lssued By: Subject to Field; Building Permit #: Amsden, Julie 193563 o7119t2017 Account# 10 $0.00 $0.00 $0.00 Every pamit issuod shal becone invelid unlessthe wo* on tho site aulhoized by such pemit is commencod wilhin 180 days atlet ils issuance, or if tha wod< aulhotized on lhe site by such pemit is suspended o. abendoned tot a penod ot 1 80 days atlet the lime the wo* is comnerrced lnspector MID#: 2017-137509 Fee Total: Paid to Date: Balance Oue: Assessor'sParcel: 412-262-54 Owner: Address: Phone: ELECTRICAL-INSPECTOR RECORD APPROVALS DATE tD/stG.COMMENTS Site-Work Underground Pole Bases Light Standards S Pool Fountains ns (monument) Life Safety /Low Voltage Fire Alarm / Dam pers Communications Cable Building Under Slab / Floor Bondin g/Grounding/UFER Y,W.l(L T orquerng Sub-Panels Air Conditioners Roof Top Equipment Factory Wired Unit Wa lls (Conduit) Walls (Rough) Ceilings (Hard & Soffit Rouqh Ceilings (T-Bar Rouqh) Meter Release f\ Rough Jdf ltJL Y-22"N,W)L Service [/eter FINAL -'7 2 '/,w\b Notes Remarks, Etc t OlINEf, BUII.DET DEL('AIATION I h.dy .lrm ndd parly of Frury rhn I da6F 6on ECo 1116 liaeLiw forrn 6fo*it8 l@nISd70ll.J Buir* dd Prol6bn Co{b Ary CU or Coudy whkh r.quiE . Fmi ro 6iiru<r. .{6. iiFovc (belitt o. ,q.r ey srd.t{e Fq ro il! i3lm.. .lo EqliE llE @ltd h, uh pat 'r ro fitc i 3istr.d nrdEn $. lE or rlE i lis!.d Fl.tr.d lo llr FrvirbN of lh. CoDlFdo.! Lic@!.d t* (Ctupl6 9. Co@hg whn S&lion ?0o0 or Divnion I of llE a6ind .rd PrcfBDN Co&) o. $r b G iE ir da9l thE 6on id rhc bGi' aor rh. illcB.d daprbr A,y vi rbrofsdion7031.t byey .prlior for r Fmn sbjcii rlE q'?lt'tn lo . civil p.rly old mE th& fivc hldH dollB tr5m) l. a o\^G o{rtE FoFtr, d dy dnpbyd unt s.s6 s rh.n rk or4dlrio.. {iU d. rlE *ut !'d tlE rrrdw ir mr i! q'd.d trofrdd 6r sl. (Sd.704,4, B6iE Dd Pmaaeiod Cod.: Ttlc Co,mrld't LtgE try dE,r, +pry lo D ow of llEFbFt, who hlil6 6 rEro6 dEol! .i *ho &E rxn wI nilulf or to*lf d tlmu$ hi! G ha ow .r!pbyc, F!vi,.d th{ sh irlFovqEL bt ilod.d uotu 6r -l..l[ no$6!, dE hrildq or iEFDlsEi i mld "rhD oE ]solonpldid\ E o!.e BiL,r wil h.w dE hrd6 ofFlvirB rhr lE d $. dn lbl hxu or inFor tlE plFry 6r dE p(sF* of l. E ow of th. FoFry, m ddNiv.ly condi'B "th li.qE d.o.rddb ml(Ecr rlE Fld (sd. 7014. 86!6 .,n hDarin C.&: Th. Conhroai l.ic@c Llw do6 mr !D?ly ro & o$E otFoFry *ho b{ildr or improv6 rh66c dd vho N rrl] lm sh Foj.lrr $nh r Con dorl3) licaBa!,,udu!rn ro E ( odr-roa. l-i.cg Lr*) I e.ropl utrdo Sctinn .a &PC forthnren }AB5!8II!OMTE!SAIIQ! DICIAf,AITO! I h6.by .mm unda Flhy orFjuty oe or$. aollos ,B d6lI.lird: -! hlrr r'd yill mi, .iI. CalifErl. of CoMl to SdfiBqE 6r s.rd o"p@rbtr 6 Fovid.d to. b, Selion l?00.f rlE td., Cod., fs llE Ffffi. of E wt fd *,li.h rh. Frn! i! is.<l )(l hn'..,i will roid.in *Drt6' .onFsr6n i6ure., s r.quncd br S€li,o 17@ oallr L.trr Co&. tor llE Ffotu. of llE svl fn *hih rhi! FniI ir isrd My worta ontEldi(o itule.ftir.n rElay nuebc ar,*, 3w+c-fwtl 1,7S bfia/t-l I carrry rhll 'n rhc F6md of rh. *o,l fo. utth thir Fm'r ir is.d, l.lEll mr mpkry &y Fs. ir oy nllrE - E lo 6@E {tilt b fi. elt6 .omFEibn h*! otc.litomi( dd rgE thd il I O.uld b.com sber lo E w.l6' orp.rdion FovlrioM olsdion l70o olih. llbo. co&, I fiil fdh*nh onpl, $irn rbs prcv.oa \IAnNING' F.ilu. ro Ko. $rrt6' cosFMrn .o!(rs. ii unlr*tul. !d .hrl ubj.tl & dployq to (mdll porr6 rn<t .nrl fin6 !p lo oE hun&.d thoB.trd d.,lla (tlm.mo), m lddnion ro ih. con ofc.frFdaioi. d.d86 a Fovid.n for Lh. Sdlior 1076 orrlE l.br Code idad.d donEy'. fc --Z--.-1/re,4 ) ucFNsr qtol.'h^cruR _.7\Dtczgarlon ,./ I I horby Im uidd F.!n, of pdjury rhd I m li€ld u,r.lq Fr.n. ore6,ptc o (corJBrds r h Sein. 70001 of Dilnir. l ol th. BlJl!|',6 si Pro(€sB co<t , ad Dt l(oq ! u lull fo,* "a1U.----' ,"*o*,-- O-=-l{- o.", _ )l/ tq /t)l]c.MNunha:z I ha&y lrm uldc Dd'lhy of D6iury lhi tha! i! . 6r(rudb, is.d (1i6. lO9?. cit C ) ofrh.rod tu uti(h lhi Fnir i AllUIANI.![d:lJAAIq! I ha*, .ftr unia Frty of paJury oE ol th. folhsinB dclo.tiod: D.mhiotr Pomne^lbdo! Notificdbn F.d6.l R.suldiod (Tnt 40. Pm6) . , Rcqli'td lnlq of Ndifiqrbn I cclia, rha rlE f.d6d r.suldioB r*rdins n!d6 lqmv.l o. nor rppltsbl. trr rha FoF . I cqriry rhd I h.\r r6d rhir .Fph.io. rd i.r. rhd rh. !tnv. rnrornr(ion a .or..r I .ern ro ooply wnh .ll cny ..d Cotrnit ordilad ad S!.r. ls ELra ro hrildiry coalflcriotr ai ha.b, drbm. r.FB.dd'!6 oarhir cnt .rd Cbmr! lo 616 utrn rh. .bv. m6tior.d lmpqiy fd BD<clion rurD(E. Appllr.nl or.1861 Sisn.lure &ev >1r?4 ) I I I I I II Transformers u \/ I *-SANTA NA lLt\INC fiX[U[\-C ltl\fi Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-s800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST soL-01 cBc 2013 solar Photovoltaic (PV) checklist for Detached sINGLE FAMILy RESTDENCES onry Instructions: The licensed contractor of record shall com plete all sections, answer the ten questions andsign the certification section below. A copy of this form sh all be attached to each of TWO sets of plans, ofminimum 11" x 17' size. lf answerinq NO to an y of the questions.plan check sha ll be re quired. Proj ect Address: H LL v-le"YOC c<Contractor Company Name: Contractor License Number: YES NO &tr q 4D/{2_ Are the following applicable to the proposed project? Will the PV system layout provide the required three-foot wide clear access pathways per Section 605. 11 of the California Fire Code, and is this shown on the roof plan? Will the PV system be installed on a roof having only one roofing layer with no overlays? Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? Will the PV system weigh maximum 4 pounds per square feet or less? Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be installed with a space of 2" minimum to 10,, maximum between the underside of modutes and the surface of the roof? Will the PV system be installed without using any ballast system or counter_we ight system? 2 3 Eg Ettr 4aEO ho Ftr f,a ?tr ?a 4 6 7 8 I Will the anchors be installed with a maxjmum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Will the minimum 5/16" lag screws be installed with a mjnimum ol 2-112inch embedment lnto roof rafters (with pre-drifled hores) and is this minimum embedment shown on the plans? Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including proiect specific site plan, pV layout, anchorage spacing, anchorage details and manufacturer's pV support information.) '10 Print Name: Phone Num Email Address I certify under penalty of perjury under the laws of the State of California that the above is true:\r Signature 5't-o.1 Rev 11/'19/2015 rJi €@ Date .co EXPEDITED PERMIT PROCESS FOR PV SYSTEMS STANDARD STRING SYSTEM The Solar America Board for Codes and Standards (Solar ABCS) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majoriry of small-scale PV sysrems. Those systems wirh unique characteristics may be handled with small addirions ro this Expedired permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for rhe Standard String Sysrem to use with the Expe- dited Permit Process. The Micro.lnvefter. AC Module, and Supply.Side Conneclion [orms are also available as interactive PDF files at www.solarabcs.org/permit_ting. ln jurisdic- tions that have adopted the Expedired Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for rhe Iocal jurisdiction. wH G r{ /')r I k.- S \r/.) )\5<q|k x --- IXPEDITTT) PTRMIT PRo(--ESS I()R PV SYSTEMS hto It I o ;+. j; i.:._.-:Ari: -.-.:.i-1?.,: _''.E9r! T f.:i:.l,. \l oeo U, E s 1 BID ELECT,FLBG iK c -9-rNo) I ET FL@O ZONE OCC. GFOUP- CONSTR T t,r RlntAArr ODE [ioc 'trc sc coIrtcU;T EXPEDITED PERMIT PRoCESS FoR SMALL-SCALE PV SYSTEMS STANDARD STRINC SYSTEM The information in this guideline is inrended to help local jurisdicrions and contracrors idenrify when pv sysrem installarions are simPle. needing only a basic review and when an installation is more complex. It is tikely thar 50 % -l6x of ^ll residenrial s,stems will comPly with these simple criteria. For projects that fail to meer tlle simple crireria, resolurion steps have been suElgested to provide as a parh to permir approval. Required btfonnation for Perrnit: I Site plan showing location of major components on the property. This drawing need not be exactly ro scale, but it should represent relative location of components at site (see supplied example sire plan) pV arrays on dwellings with a 3'perimeter space at ridge and sides may not need separare nre service review. 2 Electrical diagram showing Pv array conhguration. wiring system, overcurrent protection, inverter, disconnecrs, required signs. and ac connection to building (see supplied srandard elecrrical diagram). 3. SPecihcation sheets and installation manuals (if available) for all manufactured components including, but nor limited to, PV modules. inverter(s), combiner box, disconnects, and mounting system. Step 'l : Structural Review o[ PV Anay Mounting System Is the array to be mounted on a detned, permitted roof structur€? Eyes ENo I No due to non'compliant r@J or a ground mount. submtt completed worhsheet lot the structure w(sl RooJ Information: l. ls the roofing rype lighrweighr (yes = composirion, lightweighr masonry. meul. etc. .)Compshingle I! No, submit completed worhsheet for roof stucture WKS1 (No = heavy masonry, state, etc )2 Does rhe roof have a single rool coveringt Eyes Eno Il No, submit completed. vorksheet Jor roof structure WPiS| . 3 Provide merhod and type of weathcrproofing roof penetrarions (e.g. flashing. caulk)Flashing,Caul king M o unt ing Sy at em lnfmmtti on : L Is the mounting structure an ejgineered product designed to mount PV modules with no more than an Ig" gap benearh rhe module frames? 14 yes Ll no IJ No, Wvide details ol structural attachment certiied bt a dcsign pro|essionat. 2 For manufactured mounring systems, frll out information on the mounting system below a Mounring System Manufacturer sunpower Product Name and Model# invisamount. R€sidontial mounting system b Total Weight of PV Modules and Rails 594 bs Total Number of Attachment poinrc22 Weight per Auachmenr Point (b + c)44 s (if grea[er than 45 lbs. see WKS | ) Maximum Spacing Between Attachment points on a Rail 72 nches (see product manual for maximum spacing allowed based on maximum design wind speed) Total Surface Area of PV Modules (square feet) c d e f c ft: Distribrrred Weighr of PV Module on Roof (b + l)2.3 lbs/ft'z Il distributed weight ol the pV q. tem is greater than 5 lbstf, see WNSI . Step 2: Electrical Review o[ PV System (Calculations lor Electrical Diagram) In order for a Pv system to be consldered for an expedtted permtt prccess, the followlng must apply: I PV modules, utility-interactive inverters, and combiner boxes are identihed for use in pV systems. 2 The PV array is composed of 4 series strings or less per inverter. 3. The roral inverter capacity has a conrinuous ac power ourpur I J,440 Watts or less 4. The ac interconnection point is on rhe load side of service disconnecring means (690.64(8)). 5. One of the standard electrical diagrams (El.l, EL la. EI.lb, or El.lc) can be used to accurately represenr rhe pV system. lnferactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the stdndard electrical diagro.m completely. A guide to the etectrical dlagram is provided to hetp the arylicant understand each blank tolll tn. Il the electricat systan is more complex than the standard electrical iiagram can elJectively communicate, provide an alternatiye diagram with appropriate detail. 2 txpEt)trED pEuMrr pRocEss roR pv sysrEMs GILBERT BAILEY 4.48 kW (DC) PHOTOVOLTAIC SYSTEM 2225W HEMLOCK WAY SANTAANA, CA92704 -r OPE OF W RK: sOI-AR PA}]ELS SOLAR PANELS INVERIER IIMRIER 4 - SPR-E19-320 - sE3800li-l.Js SHE ET INDEX: E2 . NOTES E3 . PROPERTY PLAN E4 - NOT USED E5 . ROOF PLAN E7 - SINGLE LINES E7.1 . NOT USED E8 . ELECT. NOTES E9 - SIGNAGE VICINITY M AP N o {N) SE38OO (240V) INVERTER ir.riecaereo oc otscoHtecr ARC FAULT PROTECTEO FRONT OF RESIDENCE (E) IOOA BUS CENTER FED (E) 1OOA MAIN BREAKER SERVICE POINT E UTILITY METERING N SITE PIAN SC.A|,!: ,12' = 1''o' NOTE: ALL SCALES S ET TO 11X17 SHEET SIZE EXISTING HOUSE I t a e iI ! i e: a Y I a 8 E{ ul! .EJIrlI $ .J4qs:.89 , , 4qhl E} a ul)a tr) F-n u.l(o o 3 ie i!!tlr Eirl illltl llil ll 'l{ildEill E]I I t "^: 'l I t .' I til @ $RUCT INFO IIIVERTER SPfCS I't@urf sPEcs ISHRAE AMBIEM IET'IPfRATURE SPECSOTNMftR SP€CS Hhh Ternp EfiREME 0.t MIN It{V IRSB&NHB QTY:1 vOtTlG[: rrlATTAGE: (rC EF::240 t8o0 98 irotULf TYPE: QTY: sPR-El+120 14 vo(i 64,8 15.:6.24 WATTl6tr mlt{E mLOR:120 Sllcx Impi 586 Vpmar: 54,7 2.C UnUTY @+lPlr{Y: i{sP VotTAGt:s(E 1201244 MSP t0C: SERV. TYPE: MSP GRouilD RtGHr lr{oERmou D (r.r) R00 oPmIZERiP{0 QlY: 14 MAx STRTNG (EI:72 & 95 WATTAGE:ISC:15 t50 lr" c 51" c coNoun OTY GAUGE: !,VIRE OE{ATE CONDUIT ocP'75'C RAnNGI , opERAnNG _STR|NG _... = M' VOLTAGE AMPS ''''- AMPS STRING MAX. SYSTEM VOLTAGE GRNO srzE GRNDWRE TVPE ?10 t6A90,lor.nr1 aN t 350 128 r r25. 16A s9c z tl EVl 1 1C aor 7C , I : 12! r 1r5 : l5A!Q0 / t50 500v l t4'Eqr 3 r0 aor90rt90 16 r1?5= 20A WIRE OCP FOR WIRES CONNECTED TO EREAKERS TO BE GREATER THAN THE SIZE OF THE SREAKER. EQUIPT,IENT TERMINALS ARE RATED AT 75'C. STRING AMPERAGE NOT TO EXCEED THE 75OC RATING OF THE WIRE THAT IS ATTACHED TO THE TERMINALS. (E) lOOA CENTER FED [1AIN SERVICE PANEL sE3800H-US INTERGRATED DC DTSCONNECT ARC FAULT PROTECTED 1 STRING oF 14. 2 I'OOUTt9 GROUND€O WfTH INVISIT,tOUNT.I W/ RAPID SHUTDOWN DEVICE 120% RL'I-E -ca!.--!ttaxrS- __t1-9c-12)" 1mA = 20A EGC/GEC BOND TO EXISTING UFER OR : DRIVE NEW GROUND ROD !{IN 6', FROM (E) ROD AS NEEDED : r-rtta!I !!I! aa!attaaaa ----v EGCII(E) LOADS 20A/2 T -t _l TO120/240V UTIUTY SERVICE !alttI'III!I { ^1F\ 5 i-5.r,t;iiE 15=!i aIo I nI ,lf,TI;!a !!t "[ -9 - ;g ul I: < 33.o ,I6(e J*do 3i 3E< h#: ;BS Ll 1 lt lEl !il il ,l .l it T "t"Etl-trlti IiII E7 a @ Notes for One-Line Standard Electrical Diagram for Single-Phase PV SystemsSEMPERSOLARIS ltc r 973152 Site Address: Site Name: -,-** System AC Size: .,. odn By DANTEL HESTER SIGNSf E G!IDL9ECIION / NOTES FOR ALL ORAWINGS:- PV MOIULE &ATIIUGS @ SfO(Gride SeetionJ)SIGN FOR DC OISCONNECT OCPD = OVERCURRENT PROIECTION DEVICE PHOTOVOTTAIC PO\A/ER SOURCE MOOULE MAKE unpower noreo,rpp cuear*r ] 16 MoDULE MoDEL SPR-E-19-320 NATIONAL ELECTRICAL COOE. REFERENCES SHOWN AS (IVEC )OO(.)(x) RArED MPP voLTAGE 24o v MAX POWER-POINT CURRENT (lw) ,5.86 A 00 l!4,7 64.8 MAX SYSTEM VOLTAGE MAX POWER,POTNT VOLTAGE (VyP)INVERTER RATINGS (Guide Section 4) 45MAX CIRCUIT CIJRRENT oPEN4tRCUtT VOLTAGE (Voc)--SOLAR EDGE WARNING: ELECTRICAL SHOCK HA2ARO-LINE AND LOAD tvlAY BE ENERGIZED IN OPEN POSITION sHoRT-crRcurr cURRENT (isc) 6.24 INVERTER MOOEL SE3SOOH-US MAX SERTES FUSE (OCPD)MAX DC VOLT RA'TING 240 vt'i MAXTMUM PowER (Pu) l32O MAxVoLIAc,ECnPsoovocLsoo MAX POWER @ 40oC l SIqNfOR INVERTTR OIPO ANO AC DTSCONNECT flF USED) tNOMINAL AC VOLTAGE PL 16 tr_ yoe LEII 9gtFl(.v1S9ty9 Er !16.6av4 AC CI.JRRENT 4lrF coEFF supplrEo. crRcLE uNrrs 3.5m4,/.C OCPD RATING souRCES (urLrrY ANq !9!lR) I UOfESfOBABFAYJIECUIT WlRlttc|GrJde Ssdiorr 0 end-E-eld AepqnCir D:UOTELFojINVEBITEI e lBCUlr-S {q'JdeJedie! LaoC $: 1,) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION, LOWEST EXPECTEO AMBIENT TEMP , OC 1) IF UTILITY REQUIRES A VISIBLE.BREAK SWTCH. DOES THIS SWITCH MEET THE REQUIREMENT? YESI NOO N,iA O 2) IF GENERATION METER REQUIRED. OOES THIS METER SOCKET MEETTHE REOUIREMENT? YES I NOB N/AO 3) SIZE PHOTOVOLTAIC POWER SOURCE (OC) CONOUCTORS AASED ON MAX CURRENT ON NEC 690 53 SlGN OR OCPD RATINGAT DISCONIiECT 4) S|ZE tTVERTER OUTPUT C|RCUtT (AC)CONOUCTORS ACCORDTNG TO |NVERTER OCPD AMPERE RATING. (S€. Guid6 S.c{on 9) 5) TOTAL OF . INVERTER OCPO(S}, ONE FOR E,ACH INVERTER, OOES TOTAL supply BREARErS coMply wfiH r2b% sus$R ExcEproN rN 690.oa(BX2xa)" YES N NOO 2.) HIGHESI CONTINUOUS AMBIENI TEMPERATURE EASEO ON ASHRAE HIGHESI MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION, HIGHESTCONTINUOUS TEMPERATURE L.C 2.) 2OO5 ASHRAE FUNDEMENTALS 2% OESIGN TEMPERATURES DO NOT EXCEED 47OC IN THE UNITEO STATES (PA].M SPRINGS. CA IS 44,1OC), FOR LESS T,IAN 9 C.JRRENT.CARRYING CONDUCTORS IN ROOF+'OUNTEO SUNI-IT CONDUITAT LEAST 0,5'AAOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47.C OR LESS (ALL OF UNTTE0 STATES). a) 12 AWG, gI,.C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MOOIJLES TryITH Isc OF 7 6A AMPS Oq LESS WHE\ PROTECTED BY A 12.AMP OR SMALLER FUSE D) 1O AWG, 90€ CONDUC TORS ARE GENERAT LY ACCEPTAALE FOR MOOJLES WItH IsC OF 9,6 AMPS OR LESS WHEN PROTECTED BY A ''AVP OR SMALLER FUSE, NIS Dale NOTES FOR STANDARD STRINC SYSTEM ELECTRICAL DIAGRAM : a- ? ') c:l = a a ; --_-.--._-.-- l --r------------- 51 0o SOLAR PV SYSTEM AC POINT OF CONNECTION i--------------- Ac ouTPUTcuRRENT 16 Al_ ___ __- +_ _._ _- l NoMTNAL AC voLTAGE 24O v THIS PANEL FED 8Y MULTIPLE tr"""