Loading...
HomeMy WebLinkAbout10196830 - Permit?P"lProiect Address: 2822W Brook St Assessor's Parcel:109-741-18 Lot. 134 Bldg: Address Range Suite Range: Zoning: RlBlock: NA Tractr 4025 Historicr No city of Santa Ana 20 Civac Center Plaza (M-19), Santa Ana, CAI27O2 Building Permit Counter: (714) 647-5800 lnspection Requests: (714) 667-2738 lnspector Section: (714) 647-5853 Permit #: {O{96830 Pin #: 83586 Building Use: Job Type: Nature of Work: Existing Bldg. & Use: Proposed Use: Single Family Dwelling Solar Solar SFD WATT GARAGE Occupancy: Constr Type Code: Flood Zone: # of Stories: R.3, U VB cBc 2016 x-0602320256J 1 'I st FL Area: 0 2nd FL Area: 0 Other Areas: 0 Garage Area: Total: 0 Patio: T.l.Areal Yards Req'd: Valuation: 0@0 $26,400.00 Description of Work: lnstall roof mounted pv panels. Per Residential Photovoltaic checklist Botchi:44426 - 6/2r,/2IJLB I0t LROSALF:S 0ffice: CTYH TP(lnE+: 39 1 of 2Acct+: Ref+r 1r:1196$3r-l Rcpti:02300?ll - 6./21./?n1si ?r19 PHPlanning Conditions:Trcnso ':t i on Tdt tt I i171 .5? Phone: Tenant: Ricardo Soto 2822 W Brook St Santa Ana, CA 92704 (714}-715-1433 Engineer Primarv Structures.j"iil,"i'oBBFtFF-r:onst r.uc t. ior, Tr. :Contractor: SunErgyConstructionlnc Address. 1641 Commerce Street Corona, CA 92880 Phone: (951) 736-2982 State Lic #: 1005730 Lic Type: B, C-10 Bus. Lic #: 369557 Workers' Compensation lnsurance: Ca(ier: Ace American Policy #: C64388289 Expires; O7lO1l2O18 Address.s490.110 l2 , t:tt:t t577 .12 P.o. Box69?ld in.,Hermosadqqd0dlA 991&lt Otrr:r - (323) 823mffi 5td: Revo I v io3 s5859 01116tr02- 516120rr(- I Cl.- Che,:k llll42.(7 Architect / Desiqner: Address: Phone: License #: Phone: License # Planning Approval By Plan Checked By Permit lssued B NPDES lnsp. R PWA lnsp. Req'd: Plannang lnsp. Req'd: Landscaping lnsp. Req'd 'owski, Teri Date: Date: Dale: 0612112018 Subject to Field: i/isc. Receiptl Misc. Receipt: Misc. Receipt: $450.00 $2.00 $0.00 07115002 5150I Permit Fee 07176002 51672 Bldg. Stds. Revolving 07716002 57600 Cenetal Plan update No No No No Fire lnsp. Req'd: Police lnsp Req'd No No Account#Total Every pemit issued shall become invalid unless the wotk on the sile authoized by such pemit is comfienced within 180 days aftet its issuance.or il the work authorized on the site by such peftnit is suspended or abandoned for a peiod ofl80 days after lhe time the wot* is comfienced. MID#: 2018-144217 01116002 51612 $450 00 $2 00 Fee Total: Paid to Date: Balance Due: $452.00 $0.00 $452.00 Unit Owner: Address: Flood Zone Cert. Req'd: No 01.116002 51601 lnspector BUILDING. INSPECTOR RECORD SITE.WORK DATE ID/SIG.COMMENTS OWNER BUILDDR DTJLCAR TION I h.rcl,y xflirh und* |).nslly of tcrjury rhd I inr cxcmlr frunr (hc cinlrucb^ Liccnsc li* tn rhc lollowiDr rcr*']n {s'c 70'11i5 Busincss $rl Pmlc$ioi Codc): Any Cn, or county (hich requncs n FJnril lo onddd altcr. inrPRrvc dcmolhh or renrii anv sruciurc. prhrio irs issurrcc. lho rqxircs I hc opdi.anr ir sNh Nnnil lo nb tr rign.d slilcmnr rhnr h. o. shc i liccn\ed Nsurtrl h rhc rornions of lht Contrcrtr s Liccnscd ljw tchnPtcr 9- Conrtn.irS wilh Sccti T(xI oi Divnion I ol rhc Bulinc\s rd Pmlcsions Corlc).r rhrt hcorshc hcxcmpr rh.rcfremnnd lhchasr nrrhc rllcscd cx.nrnrion Anvvi'hri'nofScctiiDT0'll5bvrnv rprlica nr a pcmil subjccrs rhc af'tli.0nr lo acililpoalrrornot mrclhtrn ulc hundrcddoll,^ ls5m) t.,s osRrollhc pmFdy.or nrlcnulorEr wirh wrScsrsrhcir q)lt .otrrpctrs0rion. silldorttPork drhc{Mrumknol inh.n.n oron hd rm $[ raa.?o!r,t, Brsincs end Pmfcsion\ Cudc Thc Conlrlcror's Li.cn$ Lnw docs not applv b nn osncr ol rhc pmtrny who hrikls or nreotls llEon. snd *ho dc such *t* hin\clfoi hc6clfor rhouBh hn or h'r dwn enrPlotcc\' [o;i.kd rhsr s!.h nnpn'rcnBrs m n.r ir clx|d or olleR] for qlc. lt hnrcvcr' rlr huiLlit8 or idrpru\srctrr h s'ld snhii nnc Fr ;r conpkrior lhc owmr Buildd will h!rc rhc hhtun ol pmvins lhi h. .r \h. di:l mr huitd Dr iqrcrc lhc PDncnv ror lhc PU'FE or l. r\ owncr .f rhc l()pcny. tr'n cr.lusivcly conrrrcling wirh li.ctr{d conlrrco^ ru con{m.r ilf, Pr(,j({ ( Scc 701'l Bunm$ r Pturc*m Codcr'rhc Conrth-s Liccnsc l-rw do.\ norllPlyxt ad.wnd ollropcrrvwho huildsor ifrliovcs rhcrcon' and *ho conrmc* rd su.h Pmjccls wirh, Cofticlo(s) liccnscd Puru! rlrn.ContNtoit Li.en\' ljw)' I i cx.rrtrundcr S&rnnr-.11. & PC nnrhN rctn)n Dnl. (r*D$: wolrKFksai)vPENSArroN D[sl/&l:IlaN I hcrcby xtfinnu cr lrcn!ltyolpdriury.Nol rlE ltLk,si',! delrn ions: Ihltcandwiutuinr0r0(iailQrc.fCotrsctrrlosclllnsur.foworlcFCorFnsarion.osrrtrvidcdforhvSccrionlT(x)ofrhc ttrhor Conc.Ior rhc fdrronturcc ollhc *ork ror which thc n rmir i\ k{cd -lhatrnd willmtn aitr workcis .otrll{rsnrnrn insurancc ns rcqunc(lhvst.ri.nl7(Dofrhc l-dbor C\dc- i'n rhc P'n'nnimc or rh. work ror Nhich rhis rmir i\ ised. Myworkss lannPcnerion insumncc orici,nd P.licv nun'bcr arc: Policy Numl'.r - I.cflifrrhrrirrlNr.rntrirtr.collhc$orknn\hichrhilr--nnir i\i\{utd l rhall nor .nt|]bt inv lu(r ii drv nN rr k) d1n, hrc.nrc suht.r r, rhc worlcr' ..nr.n\drn hwc.lCxlitunni atrd rE'ct rhd ill \h.uld hc(nrt $Ihj(r rorhc \o*.rs.onDcnsrriin,provNlon\ofSccii,,n:17(X).lrhcLrhtr(itrlcl\hrll.itrrh*irhofit'lv*ilh!'xr{nrorhnrn\ WARNINC Frilurc b sorc workts'c.n'Fns!..vcrrgc is utrlrqltl r d nrll sunjcct i .nrflo)s h cri'nmrl |tn3 civil nk\ u|r k' onc hundi.d rh.uslDd dol! r\ (in rtl(liri,nr n, rhc co{ ol ro rfctr{rnr. drirlcs r\ nrovnirn f(t rhc shrtr lr176 -l'rhc Lhtr Codc. *-,fu/zt /tti DEglnAuoN Ihcrcbyomnnundcr pcndryollcrjurylhrr I x'n l,.ctrrnu c!Drovisktol(hlprq9(.onnrEncing$irlrSc'rion7OI))6rDivti'nl oi rh. Bu\ircss otrd Pdtsi(,h\ Codc. .nd myliccnsc is in lull foe oRl dffc.r. ",,",G/tt \e;alJ I hcnh!.llirm trndcr lctrrlry.l Friury rh cotr!rr.ri,)i lcidiryn!en.y tur rhcftni)nnrncc orrhe sori lnrshihrhi\ P.rnrir i\ hucd (Sc.. 1097. Ci!. C ). L.ad.i\ Nr'm - t n,lc, . AJ'lf - APPI ICAN]' DF(I ARA1'IoN I hla$y Jllnr unlcr ruDrlry.fpcrjuyotrc.frlt folk'wi|3 dc.larxri{tr1\ l)cuilnidr Pcnnils Ashc{o\ Nor'li. i,in lcdc.rlRrFuldi,,nrllnt d0. Prn6) RL\quirc krrcr of Nurifi carion I ecniiyrhr rhc l.dcnI r.sullr i{,ns rtgnlirE ish.d.rrc rrrlnrc nulnmlic$lcr. rhi\Px'jccr i!.'in..r lrgrN t).otr{ly wirlt tllCllyrnd (\ttrrl' rcpr.\.nrdn.\.l rhh ciry r d ( onrry ro cnlcr rNn rlt c1.rlr Set Backs Forms/Steel/Holdowns Erection Pads UFER Ground SLAB Floor Sublloor/VenVlnsulation Rool Sheathinq Shear Wall Framinq lnsulation/Energy Drywall Ext./lnt. Lath Brown Coal Ivlasonry Pool Fence T-Bar Handicap Req. Deputy Final Report Enoineer Final Report Flood Zone Certil. FINAL Sltfrlbl D'w^rt,,z? Certilicate of Occupancy T UI Notes, Remarks, Etc EXPEDITED PERMIT PROCESS FOR PV SYSTEMS STANDARD STRINC SYSTEM The following pages conEin forms for the Standard String System to use with rhe Expe- dired Permit Process. The Micro-lnvertet AC Module, and Supply-Side connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. ln jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. II OE-ot EXPEDITED PEII.MIT I'ROCESS FOR PV SYSTEMS \ The Solar America Board for Codes and Standards (Solar ABCS) Expedited Permit Pro- cess provides a means to dilferentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of rhe installation. \ EXPEDITED PERJVTIT PROCESS FOR SMALL-SCALE PV SYSTEMS. STANDARD STRING SYSTEM The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review and when an installation is more complex. lt is likely that 50 % -75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple crileria, resolution s[eps have been suggested to provide as a path to permit approval. Requireil Inlonnation Jor Pet'mit : t. Site plan showing location of major components on the property. This drawing need not be exacdy to scale, but it should represent relative locarion of components at site (see supplied example site plan). PV arrays on dwellings with a 3'perimeter space at ridge and sides may not need separale fire service review. 2 Electrical diagram showing PV array configuration, wiring system, overcurrent protecrion, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheers and installation manuals (if available) for all manuFactured componenrs including, but not limited ro, PV modules. inverter(s), combiner box. disconnects, and mounting system. Step 'l : Structural Review of PV Array Mounting System Is the array to be mounted on a dehned, permitted roof structure?ves E Ilo I.f No due to non-compliant rooJ or a ground mount, submit completed worhsheet.for the structure WKSI Roo.f Infofination: Yes, Compl Is the roofrng type lightweight (Yes = composilion, lighlweight masonry, metal, etc. .) If No, submit completed worksheet for rooJ structure WfiSl (No = heavy masonry, slate, etc.. .) 2. Does the roof have a single roof coveringt Elyes nno If No, submit completed urorksheet jor roof structure wKSl . 3. Provide method and type of wearherproohng roof penetrations (e.9. flashing, caulk)Chem Curb M ount ing Sy st em lnformat ion : neered producr designed ro mount PV modules with no more than an 18" gap benearh the module frames?Yes ! trto If No, provide detuib of stuctural attachment certiied by q design professionq.l. 2. For manufactured mounting systems, hll out information on the mounring system below stem Manufacturer Hoowho Product Name and Mode 14 Q.Peak-G4.1 305 b. Total Weight of PV Mod ules and Rails 1245 bs ,.44 1. Is the mounting structure an en a Mounting Sy c. Total Number of Attachment Poin weighr per ArEchmenr Poinr (b + c) 28 lbs (if greater lhan 45 lbs, see WKS I )d e nches (see product manual forMaximum Spacing Between Attachment Points on a Rail 72 maximum spacing allowed based on maximum design wind speed) Total Surface Area of PV Modules (square fee 395 frlf 3Distributed Weighr of PV Module on Roof (b + l)lbs/fa IJ distributed weight of the PV system is greater than 5 lbs/fe, see wRSl . Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: l. PV modules, utility-interacrive inverters, and combiner boxes are identiEed for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter 3. The total inverter capacity has a conrinuous ac power output 13,440 WaIts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(8)). 5. One of the standard electrical diagrams (El.l. El.la, El.lb, or El.lc) can be used to accurately represent the PV system. lnteractive PDF diagrams are available at www.solarabcs.org/permifting. Fill out the standard electical diagram completely. A guide to the electrical diegram is provided to help the applicsnt understand eqch blsnk to jll in. If the electrical system is more complex than the standard electical diagram con efJectively communicate, provide an alternative diagram with awropritte detail. 2 ExpEDtrED PERM|T PRocEss FoR PV SysrEMS I i !'-t i8t rti:c ii ; B I a 3q i o a -o _o (n 3 U) ! !I' t5 Ii 4 ,A I ritat:3 E3 T5 II I iI a *l Tiertrr;i Elip Eff;6trb o xI FItt*q i8 p,; i q I .d= e g I + zo Po -t2zo -l r .- Z EXIIDITED PIRMIT PROCESS TOR IV SYSTTMS i I3 STANDARD STRING SYSTTU ELECTRICAL DIACRAM : F do Uo L E d o to txB , CONDUIT AND CONOUCTOR SCHEDULE TAG DESCRIPTION OR CONDUCTOR ryPE COND,NUMBER OF CONDUIT CONDUIT CONOUCTORS TYPE SIZEGAUGE 1 USE-2 O or PV wlRE El BARE COPPER EQ, GRD, COND, (EGC) 2 THWN-2 El oTXHHW-2 E or RHW-2 E 1 €MT 3t4' l THW!-2 fl or XHHW-2 E or RHW-2 El INSULATEO EGC &turN.m. &.-.d PbE SlfudtudlrfurE lgtg=ggjjee 951.r$-42 One-Line Standard Electrical Diagram for Site AddfeSS: z!2?w.rra@rsr s.dr^M cae27s AC Size: Si PV MS 4 DC GROUNDING ELECTRODE COND.r"*"w [!13{l Schatner 5 THWN2 E or XHHW-2 E or RHW-2 E 3 EMI 3t1' INSULATED EGC NTS EQUIPMENT SCHEDUTE TAG DESCRIPTION PART NUMEER NOTES I SOLAR PV MODULE O.Peok44 1 305 7 PV ARRAY 3 ,LBOX (tF USEO) 4 COMBINER (IF USED) 5 DC OISCONNECT 6 rc/AC INVERTER 7 GEN METER (IF USED) 8 AC DTSCONNECT (rF USED)30A Knre Blde TyF 9 SERVICE PANEL _vAc. 200 A MA|N, __399_A BUS, __jg_A TNVERTER OCPD (SEE NOTE 5 FOR INVERTER OCPDS, ALSO SEE GUIDE SECTION 9) UTILITY SERVICE l. Ir t: -a Dsregald iJ orovided with i0vertel BUILDING GROUNDING ELECTRODEtOR UNUSED SERIES STRINGS PUT .TIA]Jn BISNK TEOIE SEEG.UTDE.AEPE-NAIXC.F!B TNFORMATION ON MOOULLANO A88AY CROUNDING 5 MODULES IN ERrES SOURCE€tRCUrTt 11 11 uoouLrs tru SERIES SOURCE4IRCU I COMBINER a - MOOULES IN SERIES SOURCE4IRCUIT INVERTER OCPD SERIES SOURCE.CIRCUIT MODULES IN ! M 8 9134572 M I 2 3 4 Sile Name Md.* Notes for One-Line Standard Eleclrical Diagram for Single-Phase PV Syslems Sile Name: "--* Sile Addrcssl Syslem AC Srze ,*^,, Matt Schatner SIGNS-SEE GUIDE SECT]ON 7 NOTES FOR ALL ORAWNGS SIGN FOR DC O SCONNECT 13 94 A 350 v MAX SYSTEU VOLTAGE 500 v MAXCIRCUlTCURRENT 15 WARNING ELECTRICALSHOCK HAZARD LINE ANO LOAO MAY BE ENERGIZED IN OPEN POSITION SIGN FOR INVERTER OCPOANO AC DISCONNECT (lF USED) SOLAR PV SYSTEM AC POINT OF CONNECTION 32 240 v THIS PANEL FED BY MULTIPLE SOURCES (UTI!ITYANO SOLAR) PV IYTODULE RATINGS @SIClcude Sealoc-s1 O Peak G4 1 305 MAX PO!'VER PO|NT CURRENT 0*)935 A MAX POWER-POINT VOLTAG E (VP)3262 v oPEN CTRCIJTT VOLTAGE (VoJ 40 05 v sHoRT CTRCUTTCURRENT (rsc)9.44 A 20 MAXIMUM POWER (PU)305 w MAX VOLTAGE (TYP 600Ve)240 voc rEMP coEFF (mvrco or %Pcl)028 IF COEFF SIJPPL ED, CIRCLE UNIIS OCPD = oVERCURRENT PROTECTON OEV CE NATIONAL ELECTR ICAI. COOE' REFERENCES sHowN as (/vEc )00( xx) lNvERIELRAI|NGSlcudesecl on4) SolarEdge SE5OOOH US 480 7750 w 24O v 21 30r NorES FoR ARRAY C RCUIT WRrNO (Gude Secl@n 6 ard 3 a.d Aprend'r D)NqTES rOB NVERTER CrRCr.llTS (Gudq S.dqn !in{g) ! ) LOWEST EXPECT AMB ENI IEMPERATURE BASEOON ASHRAE M]N1MUM MEAN EXTREME DRY BULBTEMPERATURE FOR ASHRAE LOCATION MOSTSIMILAR TO INSTALLATION LOCATION LOWIST EXPECTE D AM BIENI IEUP -OC 2 ) HIGHEST CONTINUOUS AMAIENT TEMPERATIRE AASEOONASHRAE H GHEST MONTH 2% DRY AULBTEMPERATURE FORASIiRAE LOCATION MOS'I S]MILARTO INSTALLATION LOCATION HICHESI CONTINUOUS IEMPERATUR€ a7"c lN TH€ UNITEO STATES (PALM SPRINGS CA lS,tl loC) FOR LESS IHAN9 CURRENT.CARRYINGCONOUCIORSINROOF.MOUNIEDSUNLITCONOUITAT LEAST O 5'AAOVE ROOFAND USINGTHE OUTOOOR OESIGN IEMPERATURE OF 17'C OR LESS (ALL OF UNITEDSTATES). .) 2 Ar^G gOlC CONDUCIORS aRt GtNERAtLYACCaPTABIr roe OOULES WIHricor,63AMPSORLESSWHft! PROTECTEDAYA 12.AMPORSMALLEF b) 1O AWG,90.c CONDUCTOPS APE GEI]EPAL.Y ACCEP'ABTE FOR UOOL, FS s WHEN PRorEcrEo BY A l5 AMP OR SMALLER I) IF IJTILI-Y REOUIRES AVIS'BLE.BRtAX SVUICq ooFSTHISSWICI MFE- THE REOUIREU€NT7 YESI NOO N/A O 2) IF GEN€RAT]ON METER REOUIRED OOESTHIS METER SOCXET MEEITHE R€OUIREMENI?YES I NOO '{/A E] 3)S|ZE PHOTOVOLTATC POWER SOURCE (OC)CONOUCTORS BAS€OON MAX CURRENTON NEC69053 SIGNOROCPO RATING AT DI*ONNECT .}SIZE INVERTER OUTPUT CIRCUIT (AC) CONOUCTORS ACCOROING IO INVERTER OCpo AMPERE RATll.lc (s.. Guid. s.dB 9) 5]TOTALOF " INVERTEROCPOiSj Or\C FOR IACH INVERIaR oOaSTOTAI siJppLy BRE {PEFS coMpLy wTF ,2bL BJsaaR axcEPTroN rN 690 6.(B)(2)(r,t YESO NOO NOTES FOR STANDARD STRING SYSTEM ELECTRICAL DIACRAM z F o a I a tsc MAX SERIES FUSE (OCPO)