Loading...
HomeMy WebLinkAbout101104835 - Permit (2)Permit Counter' (714) 647-5800 lnspection Requests (714) 667-2738 lnspector Section: (714) 647-5853 Project Address: 1908 W Secrest Way Unit Bldg: Address Range: Assessor's Parcel 40a432-02 Lot 13 Blockr NA ftacl 4572 Historic No Suite Range: Zoningr Rl @ .,Cify of Santa Ana 20 Civic Center Plaza (M-19), SantaAna, cA 92702 Building Permit#: lOllO4E35 Pin #: 90249 Building Usel Job Type: Nature of Work: Existing Bldg. & Use Proposed Use: Single Family Dwelling Reroof Reroof Sfd w/att garage R-3 VB cBc 2019 x-0602320259J 1st FL Area: 2nd FL Areal Other Areas: Garage Area: Total: Patio: T l.Area: Yards Req'd: Valuation: S6,792.00 Occupancy: Constr Type Code: Flood Zone: # of Stories: 0 Description of Work: Tear otf existing, install 24 squares of Duralite Saxony IAMPO ,r412. Planning conditions: Ownel Address Phonel Tenant: Luis Baeza 1908 w Secrest way Santa Ana, CA 92704 Contraclor: Be King lnc dba King Roofir Address: 1044 W Orange Road Santa Ana, CA 92705 Phone: (714) 542-0101 State Lic #: 759061 Lic Type: B, C-39 Bus. Lic #: 311980 Workers' Compensation lnsurance: Carrier: State Compensation lnsurance Fur Policy #: 9214300 Expires; 0613012021 Address Phone. License # Architect / Desiqner: Address Phone: License # Fire lnsp. Req'd. Police lnsp Req'd No No Account# Kelaher Selena web user Date: 10/05/2020 Date: Oate: 10/04/2020 Subject to Field: Misc. Receipt Misc. Receipt Misc Receipt 077760 0 2 07776002 0777600 2 0777600 2 07776002 Permil Fee Microfilm Records Bldg. Stds. Revolving General Plan Update lssuance 57607 57 770 5 7672 57600 57607 $345.28 $4.05 $1.00 $23.79 $59.30 Tolal Flood Zone Cerl Req'd: No Every pe.mit issued sha becone nvehd unless the work on the srte authoized by such pennil $ cofimenced withn 360 days altet its issuance,ot if lhe work authoized on lha sita by such petfiil is suspended or abandoned fot a pedod o1360 days after the time the wo* is comfienced lnspector MID#: 2020-161899 N/A - No Balance N/A - No Balance N/A - No Balance Fee Total: Paid to Date. Balance Oue: $433.42 $433 42 $0.00 +(t- Engrneer Planning Approval By: Plan Checked By: Permit lssued By: NPDES lnsp Req'd: No PWA lnsp. Req'd: No Planning lnsp. Req'd: No Landscaping lnsp. Req'dr No SITE.WOBK DATE ID/SIG.COMMENTS Set Backs Forms/Steel/Holdowns Erection Pads UFER Ground SLAB Floor Subf loor/VenVlnsulation Rool Sheathing t2aYln t)wz n I Framinq lnsulation/Enerqy Drywall Ext./lnt. Lath Brown Coat Masonry Pool Fence T-Bar Handicap Req Deputy Final Report Engineer Final Reporl Flood Zone Certif I FINAL tlLtl4\DA.{rY T Certilicate ol Occupancy I I Notes, Remarks, Etc BUILDING. INSPECTOR RECORD OWNER BUII-I)EN DEL(:^IIATION . I h.rchy r(no unJ( lttux, t,l Frpry rhir I !m.tcmpr hnm rh. (i,nhdnF' l,f,cnEJ-av ,,n rh.lo,l,*ur! ruy ls&.xrll,s Boioc\i ml Plorcisih CdL[ Any Cny nr ComD rh.h ra]ur.s . IEm n, !i,n(d.i. alr(t. rn!'Nvi &nnrl .t tllar.dy nnEntrc. ritr ro irs rs{rrNc, .ly' rcq r( 'lE alplr,r! lhr ru[ Fm () nL, \+tud s'!r.m h{ tr d slr N n(.n*J nlN.f,| t, 'hc lti)!!\i,,ns ol r& (\'or!u.rr'3|.tr.n*J l/q (Ch+'.r s. Co6m*m! uirh S&l!'n ?(xU.l l)Dili.,tr I oflhc Bus'msr.nLl Prtrlcs!'ns CoJc) rhlrlrorslr s crcnipr rh.r.fr"mlnd(lr hrsr lor lhc rlklcJ c\cqin)n An, vnturu.l S.rri'n 70.11 5 by rny lpnl(rnr n, r n.rm $b,(lsrtc snlhc n, ac'vrlpcnalryol nor mftrtutr lrvc hunlralddllum($t{{,) l. r\ .wk, nl rh.IroFny, or ny cnploler *'rh wat.s,r rhtr $k (of,Fnstrn, w'U Jt lh. *,* !d llr {u!@ r (, ! crhl or oficrcJ li)r e! l Slr 7Oi4. A \irtr\ rn.l lhlii\irN C,rlc: l lr (ir{rkntr r licn{ tru drs n,{ fiiy t' .n o*mr .l thcpn,tuy wl$tu (l\orm{'r,NrhcRm,!d*lhdmr{khk) hrnNcll ot lErcll , tr r&or3h lrrs or ro*n.mJ*,yc.r. I(,vkl.,, rhrr \ud mFtrrmnN n rn drl.Blrl or ollcnn tu vE.ll,hrw.!&, rltt l'i! o, rtr+"dv.mtrl s n,Ll wi [m nm 'ttol (,itLll)o rlr Ourr 8u'tl, vill luvc rlr hrkn ol Ih $g rMr lr ,r slr Jrl nt h,ll d lrr{roE Uk lh'lrny tu rtF ,rrFr* ol L *,f,r .l rlE nn'Fny, r'n grlusllly ronka.r DB wnh hdnsc,l (,hL rrttrs r, on{rud rlf, l0rrr (SR.' ?lr4.l. llrltrs fil lhlLsri,n C-oJc: I hc C.nrra.br'\ l-f,.nr liw Jtr\ .or llfty n, !n o*nd df lh!.n y *h,' firnJ\ or rdtr,lcs rfi.ron, rnd *h. ()nrrrN lin $(h pr.|!ah *[ h. Cnnr&t'n ! hcn{d no^ud n) rlE ConLrrttr \ Lxcnt trrl I.nc\cmfl lnncr S(aotr-, B &Pc ntrr[srlivu (llN- .lul8aE&tSaufElralloN2[ClrEAIllJ! I h(rchy rllro und.r norlrr.r F{ury oB ol thc n)lll,*'n! &ihrlri)is: I h!t! rlwrllnuinra r C., nli(rru ol Cdnsnr !, S(ll.lnsurc Lr wor k$r comFrulrr. !s F,,rilol ,,tr hy S&tir6 l7(X) ol rl{' l2tr, (',i1., ltrrhcF lonn,n{ olrhc worl nrelrehrhc ncnnir ,r r$uc,t _l hJvc rnl *rl, nrnrrD *nrk.r ! r, inFr€r}n r\urrLc a\ r.q mJ hy S( non rTrI I ol I h. titin Grlc. h{ rh. Frlr $qk h{ $h(h |tu. F.,Nr ,{,s.El Mv $.ll.s' snFn.dr!'n in\Lr.'r. unfl dl F'L} numh.r r. (""", 1&lrn,l n',r,,, Irrnrtyihrr'nrh.F-nornukc,nrlrcr,trln,wh'rfirh,rt.'tr,rN^skr,,I\hrllnlcnri'yanyr(Fotrrrtr!rnrtrnci !! r\ t' tRo,h nlh|(\r r, rltr w rh umtri\arrm l,u\nf(nll mt. jtrecrh n I \htu,'l hc.trtu suhr r,rh. u! {lcrl, (ur( nsnrrotr I)r 'vsn,ns !l Sc.r k'n 1r{rr ol rhc lill, O{c- I nrlL ndhu h (8tl! srrh rby Iln)vrNn\ lVAtaNlN(; l.uhtr. r) *(trr. w rk(\ lonFn\Jnor .recrns. r\ lnl.whrl. i rhrll n'ht(r rn.nlpl(tycr t' (mmal Fuht' r'rl !nil ,h$ tr,, i, nN l, 'll,.J r[otr\rtrJ 11,'lh'\ illrx,.llx]r. i 0-a a ltEctdSalxl[ I tEEt y llltn untl.r nculryol Frrr.y rh.r Lh li(nx{ uftlc, F)vr$n dr Chanrs 9($mrkir8 *ih selrn! 7lxDr olDrBlln J ol ihc 8!{k$ ad Pnn!$x,nr (iih. rd d, lkcn\. ( rh tuU n,( {rl (flr(r C_?r .6 /o-5 CONSTI(U('TI(IN LENI'ING ACFN(} I krny rnnn\rnJc, Fnrhyor trrNryrlrar rh.rc ^ ! (,n{nkron,cDJmS r!.nLy hr rhc ldornutuc ol Il{ vork lff }h(h rhtr lf,mit N n\0alrs.r ]ryr7 C'v C r AITUCANLIEqAEAIION I hdEtty.n_rm unlff Frllly {f Frjury ore or tu f{lk'wi.B (h'lu.l ionr: ttmllrtn P.mtl^{Eshs NdirNron RJq.l RcrlhriDs (Iittc 1(), Pdt) _R.n md lltrt. or Ndiflrrk'n _l (.n'fy lh.r rh. li cr.l rclNl{i'nr r.8ir!m8 r.h.nos Emrvdl d h, rlllrli(.tk ro rhN !n'jNr. _l !rn!{y rh.r I h4c E.d UB amlirlbn d! rl{c rh, {k .rbE irlomi'n N oGl. I {8N b on+ly wilh .ll Cill .' Counl, ordnrnrts rd SIrtr Lrwr r.LriD[ r) htrrhlnrt !(Itr '. i'd h.,.hv rtrr)xtr'/c rrv.\.trh^ (iryJfrlC.utrryn'. r.r uF,o rlr Jhrc Nn'inNl!'r,Frly l', trryNl$n pr ?o- s ''(DAplli0 l or ]\r. l Signrlun V1-o !..rir( rtrrD.inl,:_ .l Shear Wall I I I.ndd . Al,lrcr\: I \ \EI,[lUAII REPORT Number:12 BORAL ROOFING 7575 Irvine Center Drive, Suite 100 Irvine. California 9261 8 (949) 7s6-160s rr rr rr .bo rl la nr eric:r.co rn CONCRETE ROOF TII,ES CSI Section: 07 -12 l6 Concrete Roof 'f iles Originallylssued: 07/31/2015 Revised: 0812112020 Valid Through: 0713112021 2,4.2 Anachment shall bc dcsigncd to rcsist \r'ind loads according to IBC Sections 1507.3.7 and 1609.5 or IRC Scction 905.3. as applicable. 2.5 Thq Concrctc Roof Tilcs rccognized in this rcpon are produccd in Lakc Wales. FL; Brookshirc. TX: Phocnix. AZ: Hcndcrson, NV: Okeechobec. FL. Rialto. CA: Frcnch Camp. CA: Hcndcrson. C0 and Lathrop. CA: Tablcs 2 A through 2 I describc thc tilcs produced at each location. .1.0 PRODT CT t SE 3.1 Ceneral: Boral Rooling Concrete Roof Tilcs shall be used as a roof covering in accordancc with Scction | 503 of th(r IBCI. 3.2 lnstallation: Boral Concrctc Roof Tile shall bc installed in accordancc'with the applicable codc. the Concrctc and Clay Roof Tilc Installation Manual for Moderate Clinrare Regions. dated July 2015, published by the Tile Rooting lnstitute and the Westem Statcs Rootrng Contractors Association. and this report. [n the evcnt of a conllict provisions of this rcport govem. Thc TRI manual is availablc tbr download attached to ER-l0l 5 from the UES websitc at rrrrrr unilirrnr-cr r,ru 3.3 Attachment: The Concrete Roof Tile shall be attached to thc roof structure based the applicable codc as noted in Tablc I ofthis report: T,\BLE I .\1'T,\CH}IE\T DESIC\ Boral Roofing Coucrete RoofTiles recognizcd in this rcpon hale been evaluated ibr use as concrctc roof tiles. The weather resistarrce. wind uplift resistance and fire classilication properties of thc roof tiles comply with thc intcnt of the provisions of the following codcs and regulations: 2018. 2015. 2012. 2009. and 2006 Intemational Building Code' (lBC) 2018, 2015, 201:, 2009, and 2006 Intemational Residential Codc' ( IRCl 2019 Califomia Building Code (CBC) -Supplenrent anachcd 2019 Califomia Residential Code (CRC) - Supplement attached 2017 Florida Building Code, Building (FBC. Building) - Supplcment attached 2017 Florida Building Code, Residcntial (FBC, Residsntial) Supplcment attachL.d Use of the Boral Roofing Concrete Roof -files recognizcd in this rcpon is subject lo thc follorving limitations: 2.1 The roof tilcs shall be manufactured. ideotified and installed in accordance with dris repon. the applicable code and the Roof Tile lnstallation Manual. ln the evcnt of a conflict this rcport govems. 2.2 Boral Roofing "concrete roof tile shall be installed on roofslopes of2% units venical in [2 units horizontal (21- percent slope) or greater." IBC Scction 1507.3.2. 2.3 The supporting structure shall be designed to support the Ioads and is beyond the scope of this report. Applicablc Code l Crircn.r ii)r ApplLcabilirv Desi8n hli)rmatx)n :015 or 201l IBC Ultrmat. DesiBn Wind Spe€ds (\',,1 ) s lio MPtl and Mean RoofHeiBht S 60 l€ct RoofTile Installation luilnual & Table 1507.3.7 ofrhe applicable ItsC Basic Wind Sp.ed (3 sec gusl)S 100 mnh and Mcar RoofHcishr S 60 le.r 20t5.2011. .2009 or:006 IRC Rool-Tilc Inslallation R905.1.7 2.4 RoofTiles shall be installcd in accordance u'ith this repon except. uhcre the jurisdiction requires contbrmance to the l0l tl IBC or IRC. the tbllowing shall bc substituted: 2.4.1 Underlayment shall conform with IBC Scction l507.l.lor tRC Section 905. L I 3.,1 Anchoring: Boral Concrete Roof tile may be anchored by monar in accordance with the applicable building code and the TRI Manual or adhesi"ely attached in accordance with the adhcsive manufacturcr's research repon issued bv an approved evaluation service agency. The Noduct dasc.ibed in this u^ilm Evatuetbn setuca luEs) Rapon has boen avatuatert as an allamanw tuabnet. d.*n o. nathod ol .onst@toa b odlet to saasly and coapty *ith tho intqt ot uD proeisian ot tt,d code. as notad n f,ts rcpoi ard tot at teast asuvat hce to t at presci x{.0 FR(fDUterf SEAGQ||?6F€i* @slstdnce duadtity d elety as apphc,lnle- h aceo.dehc. vth IBC Sectoi 104.1 1 fh6 doclnsnt $dl only be regducst n ns entuety Copynght@2ozo by tntahauonat Assodarbn ol Aunb\g cl Mechancal Oli.EEts Al ognB ftsetuqt P1ntod n the Uanod States Ph 1-A774ESRPI. Fet 90947241f1 ueb M unnomasds.4155 E st Phtl.datonta St8ot, Ontano Cafio ,€91761-2816-USA @(@ Paoe 1 of 7 1.0 RECoGNI O\ 2.0 t.tl 'rATto\s I 2009 or 200t'I ruc Melln Rooftl.ighr S 10 tcer For Sl: I toot =.105 mm. I mph = 1.6 nvs lRefer lo S!'ction:.{ lbr $e 2018 l8C and tRC.:Rmf Tile Insrallation Manual is appticable lbr use wirh rhe 2015.2012. 1009 and 2006 tBC and fRC. ffIlUANOil REPORI Number: o Originally lssued: 07/31/20'15 Revised: 0812112020 Valid Through: 07 13112021 7,0 STA'TE}IE\T oF RECOCNITIO\ Boral Roofing Concrete Roof Tiles comply with ASTM CI492 as required by Scction I507.3.5 olthc IBC. The roof tiles are describcd by model. weight. dimensions. and tile factor in Tables 2 A through 2 I, for cach of the production locations listed in Section 2.4 of this repon. When installcd in accordance with this repon on combustible decks, thc assembly incorporating thc roof tilcs achieve an ASTM E l0ti Class A rating psr Section 1505.2 of thc IBC and Section R90l.l ofthe IRC. as applicable. Roof classifications for adhesively attached systems shall be in accordancc with thc adhesive manufacturcr's approved rescarch rcport. This evaluation repon describes thc results of research carricd out by IAPMO Uniform Evaluation Sen'ice on Boral Roofing Concrete Roof Tilcs to assess conformancc to thc codes shown in Scction 1.0 of this report and serves as documcntation of the product certification. Products arc manufactured at locations notcd in Section 2.5 of this report undcr a quality control program with pcriodic inspcction under the supenision of IAPMO UES. Shipping pallets are idcntified with the report holder's name (Boral Roofing). manufacturing addrcss, product name, installed weight. inspection agency, and evaluation report numbcr ( ER-412). The Cedarlite 600, Madcra 700 and Madcra 900 tiles are imprinted on the top sidc of each tile with an "M". all other filed tilcs arc imprintcd with the name "Boral", "Boral Lifetile". "Monierlif'ctile", or thc Boral Rooting. or Monierlifetilc or "Vostile" or logo. The idcntification includes the IAPMO Uniform Evaluation Service Mark of Confomrity. Either Mark of Conformity mav be used as shown below: @ I,\P\IO I, fS ERJ12 6.0 st Bs.rA\TlATr\c D.-\1.\ Data in accordancc with ICC-ES ACl80. dated February 2012 leditorially reviscd March 20t8). manuthcturer's dcsc ptivc litcmture and installation instructions. Test results arc from laboratories in compliance with ISO/lEC 17015. Brian Gerber, P.E., S.E, vice President, Technical Operations Uniform Evaluation Service I ru- , J al." fuza; Richard Beck. PE. CBO, NICP Vice President. Uniform Evaluation Service.v otl<ua \-t'a^a1 GP Russ Chandv CEO, The IAPIIO iroup For.ddilional information about this eraluation reporl please visit !!-!!l!.1!!i&t!L!!.!!Ig or email us at !!L-!-!!t.l1j!:!.il1or @ Page 2 of 7 5.0 IDEN't't F tC,rTrO\ I ttI a.I \ \EUA1UAII REPORI er:Z 2 'o Originally lssued: 07/31/2015 Revised: 0812112020 Valid Through: 07 13112021 ]'able 2 ,\ - f iles )lanufactured at Denver ( Henderson), CO Installed Dry $ eightl lpsf) Dimemsions: (irch)Tile !'actor l-cngih \ \\ idlh Tf (t'lr I Rntio I Slxonl Shalc. Slatc. I ountr-r SlLrrc Splil OId E ulish Ihatch g6 tTxr:i I 568 L 5 Slxonr lnrpact l{) 5 tTxtl L 56S Lll-i Vill 900 q0 tTxt-l L50-l 1.068 Villir- lmpircr l0.l t7 x l.l I 501 l0(rs I:r,r Sl: I rn.h =:5..1nnn. I prl = { Sli kg m Table 2 B - Tiles \lanufactured at Hendcrsoo. .\-\ Tile lnstalled Dry iveightl (PSt') Dimemsionsl ( inch ) f ile Factor l.€ng(h \ \\ idth tl ( tl'l Rario' Esprna Barcelona 9.0 l7 X ll'rr 1..170 t0-15 Sa\on]'90() Shake. Slate. ( ountrv Slate 9.1 t7 x ll Ior SI: I inch = 25 { nlm. I p\f= 1.88 kg m Table 2 C - Tiles llanufactured at Kat] (Brookshire), TX For Sl: I inch 15 -1 mm. I prf- .l 8R k gm- NOTES TO TABLES: l. Used on a 3-inch headJap 2. Nominal dimension. Tile Installed Dry i}'eightr (Ps0 Dimemsionsl (inch)Tile Factor Length X t4idth Tl. ( ll')Ratior [Surcclonr lrnprct 10..1 t6,.xl1 t.-l-l-l 1.017 Saxony Country Shake. Country- Slate. Country Sp[l Shake, English Tharch 10._i t6L, X tl I l9:0 9s9 Saxonr lmpact l0.s l6',, x 1.1 1.191 r) 989 Saxon) Shakc. Slalc l0.l l6'/r X ll L:l9l 0.9119 Tr.jas Espana' Barcelcrna 9.0 t6t, x l.l 1..107 t.000 V illa 9.0 16,' x ll t.-107 I,{XX) Page 3 of 7 ITile I I I I r.sr I r.oeo I I EYA]UATIO]I REPORI @ Originally lssued: 07/31/2015 Revised: 0812112020 Valid Through: 07 13112021 Table 2 D - Tiles llanufactured at Lake \1ales. l'l- Tile Installed Dry Weightl (psfl Dimemsions! (inch) l-ength \ \\ idl h TF ( ti')RltrrrI Blrcelona r()0 9.5 17 x I.l 1.515 l.0t{.1 Saxony 900 - Shake. Slate. Split Shakc. Country Slatc 95 Spanrsh S \rrcr ()99 l7 x 91'.L l -l-l 0 81,1 Villa 900 9l 17 x I.1 r.5l,r t.090 Table 2 E - Tiles l\Ianufactured at Lathrop. CA 'Iile Insralled Dr)., $ eightt (Ps0 Dimemsions2 linch) Tile Factor l-cngth X \tidrh Tl { t'rr)Rxlio: Bcrcelona 9o0 9l l7 x tl 1509 1.071 Saxon!" 900 Shake. Slate 9.r l? x t.l l.5tl 1.09{) F-or Sl: I rnch =:5 4 mm. I psf= {.88 k8/m ForSl: I inch - 25 4 mnr. I psf--{ 88 kg'ml For Sl: I rnch - 25 { rnrn. I psf--1R8 k g/m_ For SI; I inch 15 .1mm, I psf= l.ttE kg Table 2 I'- Tiles llanufactured at Phoenix. AZ Tilc Installed Drt' \t'eightl (Ps t) Dimemsionsr ( inch)Tile Frctor Lcngth X \4 idth TF (fit)RatioL Mission S Barcelona l0l 16 , x tl l.J9+I 06: Saxonv Shake- Slare 95 16.\ll l.{9.1 Ll)6: \ rlla 90 16 ',, x ll t.-107 1.000 Table 2 C - Tiles llanufactured at Okecchobce. F[- Tilr Installcd D11 $ cightr (ps f) Dimemsions! ( inch) 'I'ilt Flctr-rr Length X $idth TF { ti'}Ratlo I Bennuda IL.l.l l6r/x X l0rlt l016 0.7t6 Estate -S"7.9 t 6t: x t:l tllT 1.007 Galcna Spanish "S 9.1 17 x r0 L t.l.{0.ti.1l Plantation l0J 16t: X t-1 l.0l,l Saxonv 900 9.1 tTxt_'l t.51.'1 1.090 NOTES TO TABI-ES: I. Used on a 3-inch headlap L Nominal dimension. Page 4 of 7 Number: Tile Fa.tor I l r? x 13 | r.5{5 | r.0e8 I l I 1.,126 EYAIUATIO]I REPORI Number: r II 2 @ Originally lssued: 07/31/2015 Revised: 08t2112020 Valid Through: 0713112021 'Iablc 2 H - Tiles \lanufdctured at Rialto. CA For Slr I rnch = 25 I nnn. I p\l = -l8ll kg ml Table 2 l - Tiles llanufactured at Stockton (French Camp). CA Tilc Installed D11 \\'eightl (psf) Dimemsions2 (inch ) l.cngth \ $ idth TF (ri')Ratiol ( edrrlire 6{)()5.9 lt r, x rl 0.9-ll 0.67l l\ larlc'rr 700 1).I]:XI:]0.9.17 0.67.1 l\lrdera 9(X)9r Ilru x t.l 0.9{7 0 671 Saxon!'6{)0 SlLrte. Shlke. Splrt Shake 5.7 t7xt.'1 r5:5 l08l Saxon! 700 Sllle. Shake. Splil Shake 1.2 17 X t,',l I.5:5 L081 Saxony 900 Hartt'ord Slale. Shake Slatc. Countrv Slate 9l ITXtl I 5l t 109(l Saxony 900 - Splri Old English Thatch 9.8 l7 x t3 t.-sl5 I 0lt-l Villi 600 6.0 lTxtl l.l9l Llts Villa 900 f.i tTxll I -19-l L 5 For Sl: I rnch - 25 { mm. I p'l - I 88 lg m- NOTES TO TADLES: l. Uscd on a -1-inch hcadJap 2. Nominal dinrcnsion. Tile lnstalled Dry \l eight' (PSf) Dimenrsionsl {inch ) Tile l'actor l.ergth \ $ idth Ti (tll)Ralio Esparu lSarcelona 9.0 l7 x [].tr5.l 1.0--rl Espa ir 600 B.Lrc.krna 6()0 5.9 l7x[:.l.{5{1.0-l-1 Saxony 600 - Slate. Shake. Splil Shake 5.9 l7 x t-l 5.1-l I 090 Saxony 700 Slate. Shake. Splil Shake '7 l7 x t-l 5.1-',l I 090 Saxony 900 - Slate. Shake. Country Shakc I -',i tl x I-'1 5ll l 0q0 Villa 600 5.8 lTxt-l t.4q.l 1.061 Villa 900 l7 x l-l I .1.).1 t.061 Page 5 of 7 I I I I I I I I I Tile Factor EYAIUAIIO]I REPORI @ Originally lssued: 07/31/2015 Revised: 0812'112020 CAI,I FORNIA SUPPLENIENT BORAL ROOFIn-G 7575 lrvine Center Drive. Suite 100 In'ine, California 9261 8 (949) 756-t605 rr u rr . brtritlit nt e ricit.co nr CO\CRETE ROOF TILES Valid Through: 07 131 12021 2.,1 Boral Roofing concrcte roof tilcs usc-d on structurcs rcgulatcd by rhc Dir isien of thc State Architcct or thc OtIcc oi Statovidc Planning and Dcvelopmfllt arc sub.ject to installation provisions in CBC Secrion 1513. tor additional inlorm!lil}l| rhoul lhir errlur(ion reporl plr!se ri\il Is$.u it.rnr{\.o r 1 or emril ns ,l [ 1,, / u r rl,,rrrta..,)r CSI Section: 07 ll I6 Concretc RoofTiles t.0 REC O(;\tTtO\ Thc Boral Concrete Roof Tilcs evaluated in IAPMO UES ER-412 is a satisfactory altcmative to thc following codes and regulations: o l0l9 Califomia Building Codc (CBC) . l0l9 Calitblrria Rcsidential Codc (CRC) 2.0 PRODLCT USE 2.1 Thc Boral Roofing concrete rooftiles mav be used as a Class A, B. or C roof covering systcms complying with Sections 1505.1.1 of thc CBC or R902.1.1 of the CRCI Scctions 1505.1.2 of the CBC or R902.1.2 ofthe CRC: or Scctions 1505.1.3 of the CBC or R902.1.1 of the CRC. respcctively. The design and installation of thc Boral Roofing concrete roof tilcs shall be in accordance wirh Sections 1507.3.10 and 15l3 CBC or Section 905.3 ofthe CRC, as applicablc, and ER-413. 2.2 RoofTilcs shall be installed in accordance with Scctions 1.0 and 4.0 of ER-4ll except, rr'hcre thc building official rcquires confbrmance to thc CBC or CRC. the tbllowing shall be substituted: 2.2.1 Undcrlayment shall confomr with CBC Section 1507.l. I or CRC Section 905.1 .l . 2.2.2 Anachment ofthe concretc rooftilcs shall be designed to resist wind loads according to CBC Sections 1507.3.7 and 1609.5 or CRC Section 905.3. as applicable. 2.3 Boral Roofing concrete roof tiles may be used in "new buildings located in any Fire Hazard Severity Zone or any Wildland-Urban lnterlhce Fire Area designated by the enforcing agency constructed aller the application date shall comply with the provisions" in accordance with Sections 701A.3 and 705A ofthe CBC. or Sections R337.1.1.1 and R337.5 of thc CRC, as applicable. and with the IBC as presented in ER-412. Page 6 of 7 Number: EUA]UAIIO]I REPORI Number:2 " Originally lssued: 07/31/20'15 Revised: 0812112020 Valid Through: 07 13112021 I.'LORI I),\ SI PPLT-\I}-\T applicable. Dcsign u'ind loads shall be in accordancc sith Scction 1609.5 ofthc FBC. Building or Scction Riol .1. I of . thc FBC. Rcsidential. as applicablc.BORAL ROOFING 7575 I rvine Center Drive, Suite 100 Irvine. California 92618 (949) 756-1605 rr s s .bo ra lamerica.c0rn Ior rdditionrl informaiion.rboul thi5 or!lu.rtion rrport plca$ ri\it N $ $.IIilonrrr'r.,,or email us :rt inli, n rltili,rrn-(\.,rr CONCRETE ROOF TII,ES CSI Scction: 07 -12 l6 Concrete Roof Tiles t.0 R []( (x;\tTIo\ The Boral Roofing concretc roof tiles evaluated in IAPNTO UES ER-412 is a satisfactory altemativc to thc lbllowing codes and regulations: 2017 and 2014 Florida Building Code. Building (FBC, Building) 2017 and 2014 Florida Building Code, Rcsidential (FBC. Rcsidcntial) 2.0 LII T,\TtO\S 2.1 Verification shall be provided that a quality assurancc agcncy audits thc manufacturcrs quality assurance program and audits the production quality of products, in accordance with Scction (5)(d) of Florida Rule 6l G20-3.008. The qualiry assurancc agency shall be approvcd by the Commission (or the building official whcn thc rcport holder docs not possess an approval by thc Commission). 2.2 Evaluation to the high-\'elocity hurricanc zone provisions in Section 1409 of thc FtsC. Building and Chapter 44 of the FtsC, Rcsidcntial is bcyond thc scope of this repon. 3.0 PRODLCT L St_ The design and installation of the Boral Roofing concrete roof tilcs shall bc in accordancc with thc 2015 or 2012 lnternational Building Codc and thc 2015 or 2012 lnternational Residential Code. as applicable. as noted in ER4l2. From FBC. Building Section 1507.1 and FBC. Residential Section R905.3 we see that the installation ofthe Boral Roofing concrete roof tiles "shall be in accordance with the requirements of the FRSATTRI Florida High llind C'on<rete ard Cloy Rool Tile Instollotion lllanual, Fifth Edition where the \'",a is determi[ed in accordance with" FBC, Building Section 1609.3,1. FBC-Residential Section R301.2.1.1. or the recommendations of RAS Il8. ll9or 120. Load combinations shall be in accordance with Sections 1605.2 or 1605.3 of the FBC. Building. as Page 7 of 7