HomeMy WebLinkAbout20172419 - Permitcity of santa Ana 20 Civic Center Plaza (M-19), Santa Ana, CA,27O2 Electrical
Permit Counter: (714) 447-5800 lnspection Requests: (714) 667-2738 lnspector Section: (714) 647-5853
Permit #: 2lJ172419
Pin #: 30662
Project Address: 609 S Corta Dr
Assessor'sParcel: 108402-29 Lot. 19
Unit:
Block: NA
Bldg:
Tract: 2905
Address Range:
Historic: No
Suite Range: t^J
Zoning: A1
Owner;
Address:
Phone
Tenant Name:
BERNARDO GARCIA
509 S CORTA DR
Santa Ana, CA 927041109
ESP Contracting
1010 Esplanade Ave. #2
Redondo Beach, CA 90277
(3r0) 904-6138
Fee Type
01116002 51603 Serv Meter
0'11 '16002 51600 General Plan Update
011 16002 51603 lssuance
0'1116002 57770 Microfilm Records
/\e
Amount
57.40
23.79
59.30
4.05
Fe6
$57.40
$23.79
$59.30
$4.05
Qty
't.00
1.00
1.00
100
Phone
State Lic #: 519149
Lic Type: B
Bus. Lic #: 353769
workers' Compensation lnsurance:Carrier: State Compcnsation lnsurance Fund
Policy #: 9152657
Expires: 0211112021
R-3, U
VB
cEc 2019
Single Family Dwelling
Solar
Solar/Service Meter
Planning Approval By: Date:
Plan Checked By: I Date:
Pemit lssued By: Verduzco, ViobN Date: 12lOgl2O2O
Subject to Field: Account#
Planning Conditiong
Buildins Permit #: 1 01 10541 8
Ewry pemit issued shall becone invalid unless the wotk on the site
authoized by such pemit is commenced within360 deys after its
issuance, ot if the wo* authotized on the site by such pemil is suspondod
gt abandoned fot a penod of 360 days afiet the time lhe wo* is
commenced
s 144.54
$0.00
$144.54
lnspector MID#: 2020-163203
01116002 51600
0'1116002 51603
01116002 57770
$23.79
$116.70
$4.05
Contractor:
Address:
Building Use:
Job Type:
Nalure of Work:
Occupancy:
Conslr Type:
Code:Noles; lnstall solar panels, solar tees pd on 101105418.
Handouts glven.
Misc. Receipt:
Misc. Receipt:
Misc. Receipt:
Total
Fee Total:
Paid to Date:
Balance Due:
ELECTRICAL-INSPECTOR RECOHD
APPROVALS DATE ID/SIG.COMMENTS
Site-Work
Underground
Pole Bases
Light Standards
Spas, Pool, Fountains
Signs (monument)
Life Safety /Low Voltage
Fire Alarm / Dampers
Communications Cable
Buildino
Under Slab / Floor
Bonding / Grd(Elins / UFER .L n-44 4l
Translormers
Torqueing
Sub-Panels
Air Conditioners
Roof Top Equipment
Factory Wired Unit
Walls (Conduit)
Walls (Rough)
Ceilings (Hard & Soff it Rough
Ceilings (T-Bar Rouoh)
Meter Release .LI.?.1 tucz1 ,n
Rough
Service Meter
FINAL 2,lD'21 rzc /r,ue2a9 ozv
Notes, Remarks, Etc
/1^ a,l?
o*Nr.n auLDf,n Dil-clr ttotl
I lErtb, rltm u a Frly ol FI,.y ih. I D .!r+r 6um dr (on xr6 tid ti* fo. rlr follo$ta E.s ls.c.7orl-J
B6ilB rd Pr.rdi)r Oi.r: Any Cay .r Cany vh.h EquG . F ro .dEr. rlrr. i,qrmw. .lml.i d Ep., uy
ffi,rnrtodr rrou...Ls EqlG rlr {'t'lr.rr for sn Ftrr ro 6tr tilrd di.rd rh.lrdtEtlian.d Fltd
r. rE l,trvinN nr dr C.tu-rd r l-i$*d l,r (Ctt Fd 9, CollmEhS *ih Sdhn 7Ul) ol t)tvirrn I .t lti Buirs lrd
Ptnf.Bionr Co& r r, rhrr tE d d. i! rkqi rr'rt6lm r,!d th. h.!. lor rrr .ll.3!d .En+.ion Ary Ehin Dl S<re 7011.5 bt u,
rppliclhr for !Fmr NhFk rh. .ppli.a ro o.ivrlp.mlrrolmr mE lh.r fiw huidEd dollB (t5ln).
_1. .\ otr n.r ol rlE lrcFny. or my .mpkl}t.s wirt *.3.s I rh.ir v,k or{rndhn, *ill dr r,l *.rt .d ilt ndE ir d
iia .d or ofi.Ed ntr uE (Se 7U{4. Burin.$ !tuj PNr.sn}M ( Lrl.: TIE Codrrr,i Lt.nE tr* drE! nor rPdy r. nn o-n.t oI
ilEF'p.ny wt! hild! or inltroEs rl6q fl] *h, iltE skh s* hinelf or tH*!f or rhreu8h ht m h.r o*n.npi,r€.!,
pr.rd.d fi.r r(h ilt{'nrEmdr & mr id.n cd (,rr.rd it sL lr. lFr.w. uE hriBio! ot itrF)Emd n,r! eilh or ).e
or.onpEtn dE o*Er Builtr villh.E tlE hnLn rfFrvus d. lr r JE dn d bui! d rlrot rtE FnF, rd t FrrFE oa
_1. s o*rr of rll p..Frr, .h .r.hsn.ly !d..itr! *rh lEtrGl .dEr6 to MiM rrE FoFd (S<. 7O4a- Bes
.rn hraqncixt Th. Co doa! Li.nk t r{kEdrlrlrro&orEotFoD.nyelbh{ t' or EFoEr rlsd
.!i *|F m rdr rd rKh FtrFB dn r conddr l.ced td1d h rrr C.ddd! L&r t r)
Ltr.r.n$ !BL! Sd
!!laf,!81-ctl!lll;!larl0!
DEGIJAA.IIO!
I hcrchy rlltnrunJrr rmltyofFrjuryonc ol rh. n)lk'qr8 d(ltuur)B
_l htE &d will nrinr.h r c-.nitf,I. oI Cor ro S.lllNE nr mrt6J $rFdion. a ,rtrvid.d lor by set$ l70O of th.
lrld Cod., fd ft Flo.lrff. of th. ron fd $,hkh rtr Fmi! i i!!u.d
U IEE .'d *ill Nd.r wrr. con{Ed,n hrurE , s EquiEn b, S.rti{ l7oo or r!. t b{, co&. rot trE Fflffi. of
0E ,ql n wiIh rlD p.ftn 6 i(rd My *dlr3 o,FdM M .m .!d poliy rr&t G:
c*, G&.t. F.nA
_l cdlfy rlu h rlr tEn{nrN. ol tlE w.trt fr etrh rhn IEtr n sud. I ilEI d crpkiy u} Fr,. B u, @
s s b 5.or rut dr ro rh. hltm'dnFMbn hwi orcnrr.ms..nd rlr rhd if Lnuld b.coc ub,..r t. tt!
sortaaonlp..erlnpovurEofs.dorl7mofOEtllr,O..Ldl.fodhp-honply*irhrhorpoEDE.
WAI{NING lsiluG n, *(ur. qork.is drmp.nsurn,n.ov.to}. unldwlul, rnd ihall ruhjcl an cmploy.r h rinribl Ftuhas md
.rvrl fiEr un r, utr.lrtrtr&lJ ttxiusalrl dollm (tloo.Ollr, uldiri !, rh. (.r ofot{Erarion. d{us.r a rovi.l.d for tlE
S(rion 1076 ul rhc trh, C.d., hGr.{ rrd dt{ryi lii\
u!_L!_!!,!,!!11!
I hs!!y l'rm unl.r FMr, ot Friry rhd I n ll.El unri FDvirin o,<tE .6 e (llllu!-u_--'inl wat s4rd irlD) or Driio! l
or rh. B!,Gi rn arc, DBCdd.,,irtl-.ei!ofullllErn.ltd.
q atAt49
'*,.. Er-..,.. ?r-ru.. 9., " 1vr. "''J'\
I9N!:BlrqIl1NI.!;dlllIi.AIiENcI
\--- -_
I h.r.hy i,llrm!nd.r F.ihyolocrjury rhd thsc ( r con{Ddx'n LndinS rSdy lr (hc FIrr.Ec nrrh. *o* la' which lhi\ pc'mir k
ilru.J(sd 1097. ( ir c ).
AITIISAILDEC,IASAIION
I hqd, |trm und{ FMr, or Frry d or $. tou,,nl d.t,rrlo
D.mt'r rn PrndlArb.n.! NirfEdD! tus.l R.t!! .fl alih,kr, Pd6)
-{,_R.!ued ldrs or |*rift&,
-[_l cdil, rhr rrE Icdsn riuldi,G EB.,i'n! ulcshi rcd'vrl e m .t ltrbL ro lhn ,Nj.<.
-LI cdrI,rhd I lrrcE rhr rpplxrrbn.in tut Uu rh..h,v. irloh i.r i! ctrld. I rsrc to 6iply rnh r[ Ciry . Cou.ry
ordulu.r&d Slr. Lr*rnhry ro hrrldinS..n!erh( rd h.Eby.ut riE Epcs.liE or rir Cny rd Coory ro c.rq upon tlE
abor. 'tuiiNn.d pr)Fn, [n rrcron purIxEx
ADplil r or ,\rEr sirn&'k
IIIIIIIII
Rev. 08 07 20
D.&:rrlo1 (-o
L.d.ii AJ.I6L
-
tlotl>o
EXPEDITED PERMIT PROCESS FOR PV SYSTEMS
STANDARD STRINC SYSTEM
The Solar America Board for Codes and Srandards (Solar ABCS) Expedired permlr pro-
cess provides a means !o differentlare sysrems that can be permirred qulcldy and easily
due to rheir similarity w,!h lhe majoriry of small-scale pV sysrems. Those systems wilh
unique characreristics may be handted wirh smalladdirions !o rhis Expedhed permir
Process or may require much more informarion. depending on the uniqueness of Ihe
lnslallarion.
The tollowing pages conrain forms for the Srandard Srring Sysrem to use wirh lhe Expe-
dited Permit Process. The Micro,lnvefter, AC Module. and Supply-Side Connecrion lorms
are also available as interaclive PDF files at www.sotarabcs.org/permirring In jurisdic-
tions that have adopted the Expedited Permit process for pV S,stems. lhese forms can
be fllled ou! electronically and submlfted in eirher prinled lo.m and via emajl. An elec-
tronic format is used so thar the supplied information is srandardized and legible for lhe
loca! jurisdicrion.
0t"1 4 q
EXPTDITID IERMIT PROCTSS FOR PV SYSTTMS
EXPEDITED PERMIT PROCESS FOR SMALL-SCALE PV SYSTEMS
STANDARD STRING SYSTEM
The lnformadon ln lhls gulde,lnc ls intcnded to help local lurlsdlctlons and conrracrors jdenttfy when pv sysrem installartons
ar. slmplc, nacding only a baslc rcview. and whcn an installatlon ls morc complcx. lr is likely rhar 5,0%-75* ot all rcsidcntjal
syslems wlll comply wlth thcsc slmplc crllerla. For prolecls rhar fall ro mcer rhe slmple crircria, rcsolurlon sreps have bcen
su8estcd to provlde as a parh io pcrmk approval.
R.qtlrc.l lqformatlon lot P.rmlt:
I sltc plan showing locatlon ol malor componcnrs on lha propcny. Thls drawinS nccd nor be exactly lo scalc, bur jt
should rcprescnr rclatlvc loca!lon of componenrs ar shc (s6. $ppllcd e\amplc strc plan). pV arrays on dwellings
wlth a 3'perimeter spacc at rldgc and sldcs may not nced scparate fire scrvlce rcview
2. Elcctricaldlagram showlng Pv array conhgtratlon. wlrlng systcm, overcurrent protection, lnvener, dlsconnects.
rcquired slgns. and ac connecrlon to buildtng (scc suppltcd srandard elccrrtcal dtagram).
3. Spccificatlon sheets and in{allatlon manuals (lf avallable) for all manufactured componcnG includlng. but not
llmltad to, PV modulcs, invcricr(s). comblncr box, dtsconncds. and mounrlng sysrem.
Step 1: Structurol Review of PV Anay Mountang Syrtem
Ir thc .rrey @ ba mourEd on . &incd, pr.mln d roof rtructult? Elvc. Eno
U No d)e to non-compliont rel ot a gound n,dunt. submit compktcd worhshzer Jot the smtctwe tt(Sl.
R@l Wonnatlon:
l. ls $c roofing rypc lldhrw€l8hr (Ycs - composhton. llghrwcllhr ma5onry mctal. erc
Utlo, bmit anpl.td *lorhsll.atlor r@f sm(luTr WI6, (No - halOt nlul{,nry slate, e8...).2. Ooes rhc rcof have a singlc root covcrtngT Elycr Eno
If llo, siubnit conqlca.d *grlsh..t lor r@f strucirre wKSl.
COMP SHINGLE
f Providc merhod and typc of wearherproofing roof penctrartons (c.9. flashing. caulk)FLUSH NG
Morntlng Sy.tcm lr{onnatlon :
L ls rhe mounling strucrur. an eJgineercd producr dcsign.d to mount pV modutcs wirh no more rhan an t8- gap
bcncath rhe modui. frames7 kl YGa LlNo
II No, provttk d.a s oJ sfi/ddnal atuchfiant Grttj.lf W a d6lgn r,9rcssional.
2. For manufaciuacd moundng systcms. 6llou( lnformatlon on thc mountlng sFrem below:
a. Moundng Sysrcm Manufactur€r t_-bsF product Namc and Model#
b. Total \,blght of PV Modulcs and Rdb ]lLg_lbs
c Total Numbcr of A achmcnt Potnts$
d Welghr pc. tulachmcnr Poinr (b + c)r4 83 (if greatcr than 45 lbs, see WflSt)
a. Maximum Spaclng Bctween Atrachmcnt Points on a Rail 4 nches (see producr manual for
maximum spacing allowed based on max,mum design wind spced)
l. TolalSurfacc Arca of Pv Modulcs (squarc feco 325 8
8. Dlstrlbu(ed Wclllhr of PV Modulc on Roof (b + D 224 lbs/ft
I! dbfdbut n *zight of the PV ry't m ts grcatd than 5 tbstp, s.e Wr$t .
Step 9: Electricol Rcview o[ PV Systcm (Calculations for Electrical Diagram)
ln ordar for r PV ryIcm to ba conrldcr.d for an cxp.dlt d p.rmlt proc..s! tha lollowlng murt apply:
L PV modulca, utlllry-lnteractlvc lnvenefs, and comblner boxes are identincd for usc ln pV systems,
2 Thc PV array ls composed of 4 serles strlngs or less pcr invcrtcr.
3. The total lnveller capaclty has a continuous ac powcr output Il,44O \thtts or lcss
4. The ac lnterconn.crlon polnr ls on ihc load slde of scrvicc dtsconnccrlng means (690.64(8)).
5. Oncofrhcsrandardclecrricaldjagrams(El.l,El.la,El tb,orELtc)canbeusedtoaccurarelyreprcsenrthepV
system. lnrcracrlve POF dlagrams arc avajlablc ar www.sotarabcs.org/permitting.
Fill ort thc srandard electrical diogram compler.ly. A guida to the elecnical diagram is provi.ted to hetp the applicant
understand each blanh to ill in. U the elecarical system is morc conplex than ahe standard electricot diayam can ef.fecti'ely
communicatc, ptoyidc an alternatiye diagran whh awrcpriatc detait
2 lxrtDrrED lrRMrr lRoc[ss FoR lv sysrEMs
R@f Pncx
tDfGl (Dr6l
}Y MTA
{so Frl
r{0 0l
MO0S
AnuY I 18 180 90.5 5
ani^Y 2 l8 270 t8l l0
AIIAY ]18 90 5tl 3
Site Plan
for Small-Scale, Single-Phase PV Systems
collou(InoTES
Co6tdo. N.m,
Add...-'dPno:
.NERCYSEAVEEPAFTNERS
Sits Name: EEFN Rooo^ncu
Site Addregs: a)e sourHc.nT^DR,!€. s Nr^^na c^ ero.
System AC Size: s?n iw@5,*rcEc{c
PLAN
{t J,f!a.l{
(n)coa{uJrT RUN
PROPERTY LINE
T-v
MODULI
lLiri. Q Clu.s Otfll 000
ur69 320
MOoULt 0rMtt90t5 65 3',r 39 t'
MODUTI WTIGHT at 2 t8s
326
ToT^LR00rlntA l94l
ROOF IYPI (0MpsHlN6Lt
flo.0r sronrts I
r00fcovtMGt t6.t1\
3?'3.
ORTVEWAY
do
IT
8
L
fo
(t)rr{vERlIR
(N) AC USCO|,|ECT
(I) toril PllrEL AI0
S€RMCE EI{IXI}{CE
3.
l-!t,-fi!U (E) PATn COIER
I,.r'
I
{I{)IRR Y 1
(€)RESToENCE
zNs
W
l6'
cotioutT ToB€ Rlti oN coi{lt rl Et ocys t 1'aaovE Rmf suf,f^cE lto
rr{oER EAVES. rro q,Os€ TO RrOGtUr{ES LA8E|.!D
^r
tUr rO NTERVATS
cor€(rfl lo 8E PA,{TEo To raTor ExIEREn,/ExrsII,G 8 ctcRq.ftD @roR 6
IIs Loc rot
NI5 *.3
STANDARD STRINc SYSTEM SITE PLAN
:
F
do
Uodo.!:d.
o
F
o-x
TOTAI ANRAY ANTA
3
rtr I
o
0
oa.rc: 1Am
STANDARD STRING SYSTEM ELECTRICAL DIAGRAM
z
F
q-
U
o-!:d
c-
o
Lo
xgl
One-Line Standard Electrical Diagram for
Smallscale, Single-Phase PV SystemsENEfi 6YSERVICEP FTNERS
Site Address: 6oeso!,,rconrA nvr
5 7€O kW DO 5 r36e CfC rcSystem AC Size
Site Name; BTRNAF@caRc,A
576
o EQUIPMEN]SCHEDULE
TAG DESCRIPTION PARI NUMBER NOTES
1 SOLAR PV MODULE ro P€Ax oilo arK65 3m
NEMA38J-BOX (rF USED)
coMBTNER (tF USED)
3
DC DISCONNECT HDWAVEINVEFTEB
6 OC/AC INVERTER SOLAFEOGFTFCH
7 , GEN METER (IF USEO)
SESO@H
8 AC DISCONNECT (rF USED)NEMA 3R 3OA
2EOA l3vAc, _qA MA|N, 225 A BUS, 30 A TNVERTER OCPO
UTITITY
SERVICE
(SEE NOTE 5 FOR INVERTER OCPDS. ALSO SEE GUIDE SECTTON I
I
aI
a
Disregard if
provided with
inverter
BUILDING
GROUNDING
ELECTRODEFOR UNUSEO SERIES STRiNGS
PUT "N/4" in BLANK ABOVE
SEE GUIDE APPENOIX C FOR
INFORMATION ON MODULE AND
ARRAY GROUNDING
A CONDUIT ANO CONDUCTOR SCHEDULE
TAG DESCRIPTION OR CONDUCTOR TYPE COND NUMBER OF CONDUIT CONDUIT
GAUGE CONDUCTORS TYPE SIZE
1 USE-2tr or PV WRE E)r0
BARE COPPER EQ, GRD, COND, (EGC)
THWII-2 O or XHHW-2 O or RHW-2 E I ro ar,lT
3 fHWN-2 O or )+lHW-2 El or RHW-2 O i ro EMI 314'
4
INSULATED EGC
DC GROUNDING ELECTROOE COND, N/A
EMT
THWN-2 E orXHHW-2 O orRHw-2O 3 EMI 314
INSULATED EGC I
9 MoouLEs rN
SERtES SOURCE4tRCUtT.
9
sEF-res so
MoDULES rN !URCE4IRCUIT'
COMBINER INVESTER
ac Dtscooc Dlsco
MoDULES IN .
seTGs sounce-crncurr !
INVERTER
OCPD
)
ITIODIJLES lN .
se-ntessoupcecrncurrl
NT5 oate: 12120
2
314'I
5
2 PV ARRAY
S
9 SERVICE PANEL
II
tBox
Notes for One-Line Standard Electrical
Diagram for Single-Phase PV SystemsENTBGYSEFVICEPSTlf,FS
Site Addr6ss:
Site Name
System AC Size
srzE
576
HANWHA
MODULE MODEL O,PEAK DUO BLK-Gs 320
MAX POWER-POTNT CURRENT (t,#)9.47 A
MAX POWER-POINT VOLTAGE (VF)
oPEN-CtRCUtT VOLTAGE (Voc)40.56 v
sHoRT-CIRCUtT CURRENT (tsc)9.94 A
2A
MAXIMUM POWER (PM^I)32O w
MAX VOLTAGE (TYP 600voc)1000 v
VOC TEMP COEFF (mV/oCtr or Tol.Cl)43
IF COEFF SUPPLIED, CIRCLE UNITS -o.27
SIGNS SEE GUIOE SECTION 7
PV MODULE RATINGS @ STC (Guide Seclion 5)
NOTES FOR ALL DRAWINGS:SIGN FOR OC DISCONNECT
PHOTOVOLTAIC POWER SOURCE
RATED MPP CURRENT 15.00 A
RATED MPP VOLTAGE 240 V
380.00 vMAX SYSTEM VOLTAGE
MAx ctRcurr CURRENT 30.00
WARNING: ELECTRICAL SHOCK
HAZARD_LINE ANO LOAD MAY BE
ENERGIZEO IN OPEN POSITION
SIGN FOR INVERTER OCPD ANO
AC OTSCONNECT (rF USED)
SOLAR PV SYSTEM
AC POINT OF CONNECTION
AC OUTPUT CURRENT 21.0 A
NOMINAL AC VOLIAGE 240 v
THIS PANEL FED BY MULTIPLE
souRcEs (urLrTY ANO SOLAR)
MODt]LE MAKE
OCPD = OVERCURRENT PROTECTION OEVICE
NATIONAL ELECTRICAL CODE' REFERENCES
sHowN As (NEC )OO(.)OO
INVERTER RATINGS (Guide Section 4)
INVERTER MAKE SOLABEDGE
INVERTER MOOEL SEsOOOH-US
MAX DC VOLT RATING 380.00 v
MAX POWER @ 4OoC 7750 w
NOMINAL AC VOLTAGE 240 v
MAX AC CURRENT
r
l
20.00 A
30AMAX OCPD RATING
NOTES FOR ARRAY CIRCUIT WIRING (Guide Wion 6 and E and Appondix O):NOTES FOR INVERTER CIRCUTTS (cuido S€ction I and 9):
1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN
EXIREME DRY AULA TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOcATloN. LOWEST EXPECTED AIIBIENT TEMP r oC
2,) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASEO ON ASHRAE HIGHEST
MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. HIcHEST CONTINUOUSTEMPERATURE j .C
2 ) 2OO5 ASHRAE FUNDEMENTAI.S 2% DESIGN TEMPERATURES OO NOT EXCEEO
47OC IN THE UNITED STATES (PAIM SPRINGS, CA IS 44.1OC). FOR LESS THAN S
cURREI.II.cARRYING coNDUcToRS IN RooF.MoUNTED SUNLIT coNoUIT AT
LEAST 0,5' ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF47.C OR LESS (ALL OF UNTTEO STATES),
6) 12 AWG, gO"C CONDUCTORS ARE GENERALLY ACCEPTAaLE FoR MooULESwlTH lsc OF 7.64 AIiPS OR LESS WHEN PROTECTED By A 12-AMp OR SMAt-LER
FUSE,
b) 1O AWG, gOOC CONOUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES
WITH I3c OF 9,6 AMPS OR LESS WHEN PROTECTED BY A 1s.A},P oR SMALLER
FUSE,
1)IF UTILITY REQUIRES A VISISLE.BREAK SWICH. DOES THIS SWTCH MEET THE
REOUIREMENT? YES! NOO N/AO
2) IF GENERATION METER REOUIRED, DOES THIS METER SOCKET MEET THE
REQUIREMENT? YES tr NOtr NiAT
3) SIZE PHOTOVOLTATC POWER SOURCE (DC) COT.IOUCTORS BASED ON MAX
CURRENT ON NEC 690,53 SIGN OR OCPD RAIING AT DISCONNECT
4)SrzE TNVERTER OUTPUT CtRCUtT (AC) CONOUCTORS ACCOROTNG TO TNVERTER
OCPD AMPERE RAIING (Se€ cu'de S€cton 9)
5)TOTAL OF -:- INVERTER OCPD(!), ONE FOR EACH INVERTER, DoEs ToTAT
SUPPLY BREAKERS COMpLy wlTH 120% SUSaAR EXCEPT|ON tN 690.64(BX2)(a)?YESE NOtr
NIS Data:12120 skEEr 5
NoTEs FoR STANDARD STRING SYSTEM ELECTRICAL DIAGRAM
:
F
c-
do
U
d.c.
L:d
c-
o
!o
xtrJ
33 80 v
MAX SERTES FUSE (OCPO)