HomeMy WebLinkAbout10198497 - Permitq
Assessor's Parcel:400-273-O1 Lol 222
Unit Bldg: Address Range
Block: NA Tract: 2648 Historic: No
City of Santa Ana 20 Civic Center Plaza (M-19), Santa Ana, CAg?702 Building
Permit Counter: (714) 647-5800 lnspection Requests: (714\ 667-2738 lnspector Section: (714) 647-5853
Permit #: {O{98497
Pin #r l063{
Building Use:
Job Type:
Nature of Work:
Existing Bldg. & Use
Proposed Use:
Single Family Dwelling
Solar
Solar
SFD watt garage
Occupancy:
Constr Type:
Code:
Flood Zone:
# of Stories:
R.3, U
VB
cBc 2016
x-0602320163J
1st FL Area
2nd FL Area
Other Areas:
Garage Area:
Totat
Patio:
T.l.Area:
Yards Req'd
Valuation:$6,930.00
Description of Work: lnstall solar panels
Planning Conditions:
./.)//2{-tlcinsi:6
Fel
t\ t1't /
Owner:
Address:
Phone:
Tenant
Jeffrey Fuentes
'1306 N Linwood Ave
Santa Ana, CA 92701
(714) 350-3883
Contractor: VivintSolarDeveloper
Address: 9847 Pioneer Blvd.
Santa Fe Springs, CA 90670
Phone: (5621942-1270
State Lic #: 973756
Lic Type: C-10, C-46
Bus. Lic #: 345470
Workers' Compensation lnsurance:
Carrier: American Zurich lns Co
Policy #: WC5095013
Expires: '1110112019
Address
Phone:
License #:
Architect /
Desiqner:
Address:
Phone:
License #i
I'L t5
r i op€r
Planning Approval By:
Plan Checked By:
Permit lssued By:
NPDES lnsp. Req'd:
PWA lnsp Req'd:
Planning lnsp. Req'd:
Hernandez, Kathy
$450.00
$1.00
$0.00
07176002 51601 Permit Fee
07116002 57672 Bldg. Stds. Revolving
07776002 57600 cenetal Plan Update\N
No
No
No
No
Fire lnsp. Req'dl
Police lnsp. Req'd ffi Account#
Landscaping lnsp. Req'd Flood Zone Cert. Req'd: No 01i16002 s160.1
Every pernit issued shall become invalid unlessthe wo* on the site authorized by
such permil is commanced withih 180 days aftet ils issuance,or if lhe wo* authoized
on the site by such permit is suspendad or abandoned fot a petiod o1180 days aftel
tho time the work iscommenced
lnspector MID#: 2018-147958
011 16002 51612
$450.00
$1 .00
$451.00
$0.00
$451 .00
-8ol c L 1 (o5"/I
Proiect Address: 1306 N Linwood Ave Suite Range:
Zoning: Rl
:II
Engineer:
tl
E,U
li1
[,]
0l
I(:
Date:
Date:
Dale:1112712018
Subject to Field:
Misc. Receipt
Misc. Receipt
tvlisc Receipt:
Fee Total
Paid to Date:
Balance Due:
Total
BUILDING- INSPECTOR RECORD
SITE.WORK DATE tD/srG OWNER AUILDER DEI,CAFATION
I hd.by rfii"n unda raahy of r€rinry thai I an .x.nDl from lhc Co.tmclon l-tense LaN rorlhe follo*in8 teMn(S*70315
Busin6s d rrotKsbo Code): Any Citt or Cou.ry \hich rqpnd . Fdnil lo c.nslrucr' alr6 inprove. dmolih or rcrun v
$rucru€. prioi r.r ils irsurncc. also r.qut6 th€ .ppli.d lor si.h p.mi to fil€ a sisncn shtdtrd lhal h. or sh. is licflicd pmu r
to rhc pmvisioG oflhc Contrclors Liccnsed l-3rv (Ch.!lcr 9, Cominmcins wilh S(tion ?000 ol Division I dfih' Buli'Rl d
Prol€sionsCodc)orlhalh.orsh.is.xempllh6elionedrhtbsisfo!rhealles.i.rdnprio..Anvliolart'nolsdion70115bv,n)
oppt(a for ap.mn subj.clsth€ applicanrloaci!ilpenalryolnol'notrhMliv.hundreddollds($500)
-1.
ai oM.r oarh. Fo|Eny. o, my cmplo,6 \rnh s,*6 s lh€ir slc conPs,rion. will do lhc Nork dd th€ stnrclu€ t nor
immddl or offs€d fo; s;b ( 5<.7044. BNins nnd ftol6siom cod. Thc (rnta.lof s Lic.nf I rs do6 nor appl, to o oMs oi
thc pfl)triy reto bdildr or nnprov6 rhsstr rl who do6 such so& hims.lfor hq*lfor nro!-!t hG or hd ow..mplovc6,
pro,i,l.d lh.r ru.h iiFolmns s€ mr idoddt or ordld fot sl.. lL lt*66. dc ,rildins or imp.ordmr b $ld vithin onc ,s
ol conpldion. rhc (nwq Iruikjd will hav. rh. hndo offl o\ins tha hc or shc did nol build or inprcvc rhc pEpqtv for lh. pu4rs ol
-1,
doNn&oarlEproFny. m.xclusivcly.onradint wirh lic€ns.d contadoB ro conslru.r thc pojd (s(. ?0'14, B6ms
dd P:!ftssion Codc: Thc cdnlr.crois Lic€nsc l,aw do$ nor apllyto ano*ns orpro!.dt Nl$ builG o! idprovB thdon.
and who.onta.Bfo.suchprljca$ilhaContacto(9lic€trEdpu6udltdrh.ConlracroisLicd*tiw)
. B & P( lcr rhn,6on
WORKERS' COIITPENSATION
SEC!,ABAIIAX
t n6eby amro undd Fnall, of pslury otc oflh. lollowins deLralioB:
-l
hav. rnd will 'mi .in 6 Cedificarc of CoG6l b S.lal6urc for workm onrp.n$lion, 6 pslid€n for bv Serio. l?00 ofrie
Labor Cod.. for th. pdaom ceof Ih. wort for which the pmil is ('u€d.
-l
hav. and will mainlain wo d conpcB.lion iBU! c..s rcqut d bYSation1700 ollhe kbor Codc. for lh. pqaofln.ncc of
rhc wori for {nich $is p.nnit is sslcd My sskdt comp€Mlion insr&.c ffid md policy numb6 6c:
I c.nrry rhal i. rhe pclorMncc ofthe sork rot $hi.h rhis p.mit is Gsucd. I sh3ll nor onplov inv pd$n in.nvnd6
$ sro lx.omc subjsl lo lhc soik6 conrF.salion la*sorcal,aomii. md osEe lhal ilI shorld b.{o!n€ subj(' to lh.
sortm conDffilioo provEioroofSslion l?Ol) olrhe I.bor Codq I shall. fonhsnl.onvlt {ilh thoFprerilioN
\IARNINC: Failur. ro hure Norkrs' comFnsarion .o\mtsc is unlasful &d shall an fipbrq lo dimmal Fodri6
r. onc hundrcd thousdd ddllm ($100.000). in ad,litioo ion. daraB6 6 provid.d lor th.
Scclion 3076 olthc Labr ntqesr dd tlrot,Ey s lc
-l I
I hc,eby amm undn poahy of psjury lhar I dn licds.d u.da prorision olchapt6 9 (comnmcidS $nh S..lion ?00{D or Divisi'r I
oa rh. Busins ed Pofsio6Codc, {d my licdsc is in lull for.c dd .iIdr
It
ud q?17{v
I 0
CONSTRUCTION I FNDIN(: AGENCY
I hs€by aflinn und€r pcnally olpdjury lhal lh6c is a coturru.lio. L.din8 ssdcy for rh. ldaommc€ orlhc sorl aor ehich this Dstil is
6su.d (S< 109?.Ci!. C )
APPI I'ANT NTCIARATION
I ffiy rltm undcr poahy of p.rjury on oflh.lollovins dclrarionsl
D.Dolirio. Pmns-Asbdlos Nolilicotion F.d6al Rcsulalions (TnL 40. Pan6)
-Rcquncd
lllld of Noti6orion
-l
cdiryrhalrn fcddol rcsulalioN rcsrdine sb.stos rmoval 6c not ,tplicabl. to ihir poie.r'
I cd1iry fial I havc @d lhB al,plicsliotr !d st.l. lhal $. .boB infonnotion is cod.d I alre lo complv wilh all Cilv and Counrv
ordinanc6 and Srarc lzws r.l,rin8 to buildins cotuloclio oilh6 C It atl Cotrnrylo cnrq ulmnthc
,h,!. rnsrioned laopeny litr *,. \'./2a /t D\pflirn l or \Artrt SiA rlut
Pernrir@ nrnc (p.inl):
Set Backs
Forms/Steel/Holdowns
Erection Pads
UFER Ground
SLAB Floor
Subfloor/VenVl nsulation
Roof Sheathinq
Shear Wall
Framinq
lnsulation/Energy
Drywall
Ext./lnt. Lath
Brown Coat
Masonry
Pool Fence
T-Bar
Handicap Req
Deputy Final Report
Enqineer Final Report
Flood Zone Certif
)/7////g -?&t ,'l-/Certificate of Occupancy
Notes, Remarks, Etc
COMMENTS
FINAL
),./-,\--/-Z^-
I
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P,O. Box '1988 (lvl-19)
Santa Ana, CA 92702
(7'14) 647-s800
www.santa-ana.or9
:
sor--0r cB:2!11
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
Contracto r Company Name:
Contractor License Number:
Un.r-.iot>
V', "- ^Jr (-o\q- y
etnvTs\o
2
3
No Are the following applicable to the proposed project?
tr U/lll the PV system layout provide the required three-foot wide clear access pathways
per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan?
tr s/ill the PV system be installed on a roof having oniy one roofing layer with no
overlays?
tr \ /ill the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
tr u/ill the PV system weigh maximum 4 pounds per square feet or less?
tr \/\/ill the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
\l/ill the PV system be installed with a space of 2" minimum to l0" maximum between
the underside of modules and the surface of the roof?
Will the PV system be installed without using any ballast system or counter-weight
system?
Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
Will the minimum 5/16, lag screws be installed with a minimum of 2-112 incn
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
Are ALL the structural pages of the pians stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer's PV support information.)
tr
under the laws of the State of Californ the a
4
5
6
,fia
,6J
, Ptr
rcFJ
lcertify under
Pr nl Name.
Phone Number
Email Add ress:
nalty of perjury
ra,
414 L- \ 4
L-E
C!
-\2
Signatu re
\.r'r CL
L1
b \_o, r - cD r^
Rev 1l/19/2015
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
lnstructionsr The licensed contractor of record shall complete all sections, answer the ten questions and
s gn the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11'x 17' size lf answerinq NO to anv of the questions, plan check shall be required.
Project Address:
1
true:
Date:
flIYUUIUIUI
,,NA'ffi
,,$
NA''ffi
fiII
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (lvl-19)
Santa Ana, CA 92702
(714) 647-s800
www,santa-ana.or9
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
lnstructions: The licensed contractor of record shall compleie all sections, answer the ten questions and
sign the certification sectlon below. A copy of this form shall be attached to each of TWO sets of plans, of
o NO to anv of the questions . olan check shall be re quired.minimum 11' x 17" size. lf answertn
Contractor Company Name:
Contractor License Number
YE
Un.,-tOt>
,-,.,t q o\q- v
qa->T57.
No Are the following applicable to the proposed project?
tr Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan?
tr Will the PV system be installed on a roof having only one roofing layer with no
^\/drlar,c ?
tr Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the piane of the roof?
tr \ /ill the PV system weigh maximum 4 pounds per square feet or less?
tr Will the PV system be installed where the modules do not overhang any roof eCges
(such as eaves, gabled ends, rldges and hips)?
$/ill the PV system be installed with a space of 2" minimum to 10" maximum between
the underside of modules and the surface of the roof?
Will lhe PV system be installed without using any ballast system or counter-weight
system?
Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
Will the minimum 5/16" lag screws be installed with a minimum ot 2-112 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer's PV support information.)
tr
D
State of Californ the a
Rev 11/19/2015
I certify under p
Print Name:
tr
fie
6
P
F
enalty of perjury under the laws of the
Lq*t ^ Qvrr, u'nv.c..,", sffi ignature
DatePhone Number
Email Add ress:L-k-a \rJC\"
LA
D \4\' r - (iD ."'\
sol-01 cBc 2013
Project Address:
true:
1
2.
3.
4.
5.
6.
8
9.
10.