Loading...
HomeMy WebLinkAbout20167380 - Permit@ City of Santa Ana Permit Counter: (714) 647-5800 20 Civic Center Plaza (M-19), Santa Ana, CA 92702 lnspection Requests: (714) 667-2738 lnspector Section: (714) 647-5853 Electrical Permit #: 20{67380 Pin #: 73868 Btdg: Tract: 352 Address Range: Hisloric: No Suite Range: Zoning: Rl ryProiect Address: 1345 S Parton St Assessor'sParcel: 013-113-12 Lol: 13 Unit: Block: 13 Owner: Address Contractor: Address: Julio Velasco 1345 S Parton St Santa Ana, CA 927071627 (714) 3154860 Solarmax Renewable Energ' 3080 t2th sr Riverside, CA 92507 (9s1) 300-0788 Fee Type Amount Qty $0.00 $0.00 $0.00 Fee Phone Tenant Name: Phone State Lic #: 972048 Lic Typer C-10, C-46 Bus. Lic #: 346803 Workers' Compensation lnsurance: Carrier: State lnsurance Fund Policy #: 9070313 Expires: O4lO1l2O19 Building Use: Job Type: Nature of Work Planning Conditions: Planning Approval By Plan Checked By Permit lssued By Subject to Field: Building Permit #10198320 , t/09/2018 Account# Misc. Receipt: Misc. Receipt: Misc. Receipt: Total Occupancy: Constr Type Code: R-3, U VB cEc 20r6 Date: Date: Date:Amsden, Julie Every permit issued shall become invalid unless tho work on the site authorized by such pefinit is commenced within 180 days aftet ils issuance, or if the wot* authorized on the site by such petnit is suspended ot abandoned fot a peiod of 180 days aftet the time the wotk is commencod. lnspector MID#: 2018-147581 Fee Total: Paid to Date: Balance Due: Notes; lnstall (12) roof mounted solar panels. FEES PD ON 10198320 Single Family D\ relling Solar Solar ELECTRICAL-INSPECTOR RECORD APPROVALS DATE ID/SIG. Unde rground Pole Bases Light Standards Spas, Pool, Fountains Signs (monument) Life Safety /Low Voltage Fire Alarm / Dampers Communications Cable Building Under Slab / Floor Bonding / Groundinq / UFER Transformers Torqueing Sub-Panels Air Conditioners Roof Top Equipment Facto ry Wired Unit Walls (Conduit) Walls (Rough) Ceilings (Hard & Soffit Rouoh Ceilin gs (T-Bar Rough) Meter Release Rough Service Meter FINAL ma Y//il a {#rt I Notes, Remarks Etc I OWNER BUIt,DER DELCARATION I htr€by amnn tr.d.r !..!h, oa pojury rhd I d .r.hpt from thc ( ontd.loft LiceNe La* lbr the lollorvins rcen (5(.701 1 .t Insin6s lnn Profsion ('od.): Any Cit, or Counly *hich Equn6 , tnn( ro .snntucr. !lrd, inpolc, darelish or klatr ey struclue prbr 10 ns isuucc. atso rcqln6 $. applker lor such lEnni ro 6k a sieial srdmr rhd tu or sh. i licd.d puu@r ro rt€ prcvisioB offi. contractois Lic.ns.d Lrv (Chapto 9. Conmdc'ns Nilh Sc.tion ?000 oa Dnision :l of rh. B6in.ss dd Prof6sions Cod€) or lhal hc or she is d€,rpt da.nom ad thc bdb for rhe all.aed dmprio. AnyviolarionofsdionT0ll.5 br 0ny aptlicanr forap@ir subjdtsrhc applicg loacivilp.nalryo|nor morclhan 6v€ hun&cd dolltrs ($500) _1. a o\q6 of the FoFny. or my cmplotcs $ nfi $.96 6 lh.n $b ..trrp.Mion, sill d. fi. work md rh. sMm is mr intori€d orof€rcd fo, elc I Sc.70tl4. Busins ed ttolsions Cod. I he Conlruclor's l-icas. tiw do6 nol apply lo an oM6 of lnc pFpqly who buil& or imp!!6 dEaE ad wbo do6 such srk hins.lf or hd.lf or rhmnsh hh .r ho oM .mployts. provided rhar such iinprovoMc m mr im5d.d or offdcd tor elc lt hoNod. lh. h{'lding or imlrov.]mr i! $ld wirhin one rd .fcompl(rn( rhc Os!6 Build6 wiu hat l& hu&n ofFovin8 lhd h€ ot shc dil ml &ild or impmvc tnc proFty for lhc purpoF ol -l.6or'.crorlhc prcp61y. m cic lusivcly .o nlract in s wilh licmsd conlmcloBIo conslrucl th. Irojcl (S* 70.14. B6ns and BDasirn code: Th. (in ractols Li..n!c l-aw do6 nor aptly to o o{nd o I propdry who builds or mprov.s rhdsn. dnd who conlEcts for su.h pojecls with a Conlndo{s) lic.ed puurat b th. Conlracx, s Lic$e t w). ! m.rmfl n6do serion_, B. & P.C. lorthis r6on. Drre: O*tr.r: ]laBf,l:&Ll:olltExs ra! DE(IAIAIIA! I hd.r, aflim unds pdalr) oa pqjury on€ oflhc followinr d(ltrarions _l havc od will daintain a CcnifidcolcooHt to S.lf-lnsurc for workdr an$ens.rion, * pmv cdforbySdrionl?00oIrh. lrbor C.de lor lhc Ffonnuce o t thc worl for vhich rh. psnil is (gued _l ha!. a.d will mai.tain work.ts comp.carion iBuEn e. a .equi.d by S*r ion .1700 ol th. tibor Codc, lor lh. prfomdc. ol Myworke6 composalioa insurmcc c i6 dpolicynumb6s.: -l c€nirylhal in lh. prfoflnanc. of (hc work lor which Ihis pdni is i.s!.d. I shall nor dploy.ny p6on in m, m&nd $ dto b€cooc subj€cl lo lhc wolt6'ompsE liotr l.vs ofcalifomi& ed,Ar rh.l ia, should h.com. subjer lo lhc *0116'coipcelionp,orisioNolsdionlT00ofth.t hor Codc l rDll, lonhrvith conply wilh thos provisiotu IVARNINC liaihrc to sure *ork6' comp.Narion .ove6ge is u ld\!aol. Md sholl srbjst M onplorc ro dinrinal pdElti6 and cx'il lines ur lo on. hundrcd lhousd dollm ($100,000), in addirin 'o rh. cos ol.ompoEarion, damec 6 plovid.d for lh. Code, i dd &d rormy s fs .B"z/y ,z---. r,iir::rir;rr r orr rrr,i.rriil DEOd&flO! I h@by amrm und6 p€nah, olpdjurylhd I m licmsol undd Fovision oachagd 9 (commm.inB wirh Sdion 7000)ofDnision 1 oi thcB0sindsed Pnilis$nsCod., dd n,! I'c0\r is i', tull nnc. Llcfl..r colLgBucuoll,EtDllclc!!(I I hftbt aftrm undd poalry ol psjury th,l lh6. ie a odtucrion lodinB a!@y for rn. pqfollr@. of thc work for ehicfi lhis Fnn t issu.d (Sd. J097, Ci! C.). atfl.tc .NLD[ctaa uoN I @y arfim und6 p€n.lty olprjur)' one of lh€ lollowinB drla.tions D.molilion Po'mils-Asb.slos Noli6crlion Feddal R.rul iois{Tilt40, Pd6) -Requircd Ir(d olNorincorion ,\t,pricxnr o, ,\s.tr1sigtrnr (V^: l sse to comply wirh sllCiryed County:-:::;af COMMENTS Site-Work l-cde.s Addr6: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA'92702 (714) 647-s800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC GHECKLIST soL-01 cBc 2013 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall fill in the address of the project, contractois licensing information and answer questions 1 -10 below. Complete and sign the certification section.**lf answering NO to any of the questions, plan check shall be required.** Project Address:1345 S. PARTON STREET Contractor Gompany Name: Contractor License Number: 1 Eltr trtrtrtr trtr trtr5 8 Eltr 9. Etr 10. BE 6. trtr 7 trtr I certify under penalty of Print name: /3 p under the laws of the State of California th the above is true: Date:Phone Number: Email Address: Rev.2117l2O15 -'-SANTA ANA,'i,il,l+l YES NO Are the following applicable to the proposed project? Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? Will the PV system weigh maximum 3 pounds per square feet or less? Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be installed with a space of 2" minimum to 10" maximum between the underside of modules and the surface of the roof? Will the PV system be installed without using any ballast system or counter-weight system? Will the PV system be installed on a roof having only one roofing layer with no overlays? Will the PV system layout provide a three-foot wide clear access pathway per the latest edition of "Guideline for Fire Safety Elements of Solar Photovoltaic Systems" by OCFA? (Guideline available on the OCFA website: hto://www.ocfa.orq) Do the plans show a maximum horizontal anchor spacing of 6 feet? Do the plans show a minimum of 2-112 inch lag screw embedment into roof rafters? Are ALL the structural pages of the plans WET stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufactureis PV support information.) 2. ,) 4. Signature: