HomeMy WebLinkAbout10179333_5015 W. EDINGER #J - Plan#IIld Planning & Building Agency --- mita- Building and Safety Division 011 r,r <hi 20 Civic Center Plaza .dEL' i4idr. P.O. Box 1988 (M-19)ELECTRICAL SIGN Santa Ana, CA 92702 (714) 647-5800 REQUIREMENTS www. santa-ana.orq &#3222£314**'*"45EZiM#LatLU,m.'4tlier?Ime=irt,2&1*6·'932:*·'i:2"mmt):04:0.92422851£b.J:fitifolt.gk*-EL51 Code references are to the 2010 California Electrical Code (CEC)C-'11: 3-21-2011 A. All signs require Planning Department approval. B. All electrical signs require electric plancheck and permit. 1. Manufacturer's instructions are required at the time of submittal. 2. Submit detailed installation instructions including diagrams to the Building Department for plan review at the time of submittal. Plans must include appropriate items noted by this bulletin. 3. Cash or surety bond in the amount of $200.00 is required at time of issuance for each address. The cash or surety bond will be refunded after all required finals. C. A building permit is also required - except for open or highlight neon lighting: D. Installation Requirements: CONTACT FIELD INSPECTOR PRIOR TO SIGN INSTALLATION. (SEE SECTION G OF THIS BULLETIN) 1. Conductors and equipment shall comply with California Electric Code Article 600. 2. All metal parts of a sign shall be bonded in the manner specified in Article 250. Isolated metal parts are permitted to be bonded by using an external green insulated conductor. Equipment grounding & bonding conductors must be sized by 110.26 and protected from physical damage. Minimum size is 14 AWG. CEC 600.7 3. A listed disconnect switch in the power supply primary, shall be installed within sight of sign or have permanently installed means for locking in an "OFF" position. This is also true for a transformer enclosure. CEC 600.6 4. A listed receptacle or an approved termination device shall be used for each neon electrode. To relieve stress at terminations, tubing shall be supported with listed tube supports in an approved manner within six inches of electrode connection. CEC 600.41 & 600.42 5. Every electric sign of any type shall be listed by an approved testing laboratory and shall be installed in conformance with this listing. That includes "1 of x", "2 of x" labeling for each separate unit of a multi-unit sign. CEC 600.3 6. All "can" letters and transformers housings shall have section labels that are readily visible after installation. CEC 600.4 7. Transformers shall be located where accessible and be securely fastened in place. Page 1 of 2 .J When not inside the sign, they need a 3 foot high x 3 foot wide x 3 foot deep workspace. Transformers are permitted to be located in attics or canopies provided there is a passageway at least 3 feet high x 2 feet wide with a minimum 12 inch catwalldwalkway from the point of entry. Trandformers must be securely fastened and independent of T- bar when above a suspended ceiling. No part of sign mav be fed with flexible cord when located above T-bar ceilings. CEC 600.21(E&F) & 400.8 8. Adequate illumination shall be provided for all working spaces about elecfrical equipment. This applies to attics and canopies when entry is required to service or inspect the equipment. At least one switch is required at entrance. CEC 110.34 & 600.21 9. Doorway to an attic or canopy space shall be minimum 3 feet by 2 feet wide. CEC 600.21(E) E. Open neon outline or highlight lighting. 1. To be treated as a sign by this department. However, Section D-5 & D-6 of this bulletin will not apply. 2. Neon tubing shall be located where not normally exposed to physical damage. Open neon tubing below 9 feet shall be protected from physical damage by an approved shielding method. CEC 6Q0.30 and 110.34(E) ,. - - .:: F. Light-Emitting Diode (LED) Signs 1. Will be treated as a sign by this department. All sign rules in sections A, B, C, D, F, and G will apply as appropriate. 2. LED illumination for signage must be a listed or recognized component. Many LED manufacturers specify particular brands and models of transformers some do not. Manufacturer information to clarify this issue is required on LED sign plans. 3. Unlisted LEDs may not be used in an electrical sign or as permanently installed illumination. 110.3 4. Please have packaging or catalog cut-sheets on hand for inspector to review when LED modules do not bear listing symbols. G. Inspections 1. Contact an Electrical Inspector one (1) workday (minimum) in advance of installation to arrange a site meeting on dav of installation. 2. Call for inspection Monday through Friday, 8:00- 8:30 a.m. at (714) 647-5821. Approved prints and the job card must be on site for inspection. Page 2 of 2 Company Name: Kim Bon Jun Inc. UL File Number: E350092 0locA,1/co# Soociticiat,00,61 iL 1 . - I j , 11 l Color Red , i Connection Wire to Wire (Wire length 4 between the modules 90mm) Size L:68mm, W:16mm, H:7.5mm Operation Voltage - DC 12V Certification UL/U R Listed Power Dissipation - 0.72w Viewing Angle 120 Deg rees Waterproofi ng IP68 certified Weight 11.6g Brightness 3,000mcd : Brightness: The brightest in Korea( over 6,000mcd per LED) Nonpolor: Can be used without distinguishing +,- by attaching nonpolar circuit r Waterproof: 100% waterproof by epoxy molding type *IP68 certificate (January 2008. We are the first company to earn this certificate in Korea) : Radiant heat: Remove over 90% of heat by radiant heat circuit and maintants consistent brightness(approximately 50,000 hours) One Rank: Use One Rank Chip for same color of each module- . 73 SIGN COMPONENTS MANUAL (SAM)June 19, 2013 2. These products are rated per the Table below. When units are connected to a Class 2 circuit, their ratings are to be limited to draw a total wattage of no greater than the secondary current rating of each Class 2 power supply. IModel Input - Class 2 Output - Class 2 i HM-12RGB5A3-XY Series 12 - 24 Vdc 10-24V 24 W 3. These products are suitable for use in dry, and damp. 4. These products are each rated max. 24 watts. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. Sign accessories, Class 2 LED power supplies, Model MJ-12100. 1. The output of this component complies with Class 2 requirements in the Standard for Class 2 Power Units, UL 1310. 2. In the end product, power supply spacing to other heat producing components shall be min. 2 inches spacing to sidewalls, and min. 2 inches spacing to top of enclosure. 3. These products shall be enclosed in the end product. 4. These power supplies are suitable for use in dry and damp locations. 5. These devices are intended for factory installation only. 6. This Class 2 power supply is not provided with any grounding. The enclosure must be grounded in the end product. JUSTIN INC E235322 2663 N LEE AVE SOUTH EL MONTE, CA 91733 Class 2 Power Supply, Model 601-12[)C, 601-12DCR, 101-24DCR, C2240-12DCR, C2240-24DCR, C2240-12, C2240-12-240, C2240-24, and C2240-24-240. 1. These power supplies have been evaluated for use in LED signs. 2. The power supplies have outputs that individually comply with Class 2 circuit requirements. 3. These units are suitable for *use in dry and damp locations without a need for an additional enclosure. 4. The output of this power source shall not be connected to any other power source or provide power to components connected to another power source. 5. These products shall have conductors entering, leaving or residing in the wiring compartment or junction box extending at least 150 mm (6 in) inside. Class 2 Power Supply, Model 601-12DC-LC, 601-12DCR-LC, 101-24DCR-LC, C2240-12DCR-LC, C2240-24DCR-LC, C2240-12- LC, C2240-12-240-LC, C2240-24-LC, and C2240-24-240-LC. 1. These power supplies have been evaluated for use in portable LED signs. 2. The power supplies have outputs that individually comply with Class 2 circuit requirements. 3. These units are suitable for use in dry and damp locations without a need for an additional enclosure. 4. The output of this power source shall not be connected to any other power source or provide power to components connected to another power source. 5. The attachment plug on the end of the power supply cord is not to be removed. KASON INDUSTRIES INC 57 AMLAJACK BLVD E363080 NEWNAN, GA 30265 Power supplies with Class 2 output circuits, Model 61815000200. 1. The product shall be installed in compliance with the mounting, spacing, casualty, and segregation requirements of the ultimate application. 2. These units are provided with a Class 105(A) insulation system. 3. Input leads are Style 1015, No. 18 AWG, rated VW-1,600 V, 105(C. Output leads are Style 1430, No. 18 AWG, rated VW-1, 300 V, 105°C. The suitability of the input and output connections shall be determined in each end use application. 5. Strain Relief and Impact Tests have not been investigated. The suitability of the enclosure as ultimate enclosure shall be determined in the end-use application. 6. The polymeric enclosure of each unit has not been evaluated as ultimate enclosure. The flame class of polymeric enclosure of unit is V-2 and the necessity of additional fire barriers shall be determined in end product. 7. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 8. The output of the power supply exceeds the Class 2 output limits. This shall be considered in the end product. 5BJ SIGN INC 1800 W ADAMS BLVD E350092 LOS ANGELES, CA 90018 Class 2 LED Modules, KPL, FPL, KR3. 1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less. 2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy limited circuit and is rated greater than 12V DC. 3. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means available. LED Class 2 Module, KBJ-301, KBJ-303, KBJ-301-S, KBJ-303-S, KBJ-3RGB, KBJ-401, KBJ-403-S, KBJ-4RGB. 1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less. 2. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 3. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less. June 19, 2013 SIGN COMPONENTS MANUAL (SAM) 74 4. These products are not required to be enclosed or protected from the weather in the end product. 5. These products may be secured in place in the end product by any means available. KEYSTONE TECHNOLOGIES LLC E356111 PO BOX 246 AMBLER, PA 19002 Class 2 LED Modules, Models KTLD-80-1-24V, KTLD-60-1-12V, KTLD-60-1-24V, KTLD-60-1-24\ASC, KTLD-60-UV-24V, KTLD- 60-UV-24V-SC, KTLD-60-UV-24V-DIW, KTLD-60-UV-1214V, KTLD-60-UV-1214V-SC. 1. These LED drivers have been evaluated using resistive load resulting in the electrical input and output noted on page 1. 2. These LED drivers are provided with Class 2 output. 3. These LED drivers are intended to be operated jn_ a maximum ambient (Ta) noted as below: Model Ta (°C) TLD-80-1-24V 40 KTLD-60-1-12\/ 40 :KTLD-60-1-24V 40 'KTLD-60-1-24V-SC 40 ®TLD-60-UV-24V 40 f KTLD-60-UV-24\ASC 40 kTLD-60-UV-24\ADIW 52 1<TLD-60-UV-1214V 40 1<TLD-60-UV-1214\ASC 40 4. These LED drivers are intended for use in dry and damp locations except that models KTLD-60-UV-1214V and KTLD-60-UV- 1214\ASC are suitable for dry location only. 5. These LED drivers are provided with 18 AWG AWM input and output leads. The suitability of the wiring and the need for a suitable enclosure shall be considered in the end product. 6. These LED drivers are intended to be operated on a maximum 20 A branch circuit. 7. The need of the grounding means shall be determined in the end product. 8. These LED drivers shall be enclosed within a suitable end product enclosure. 9. For model KTLD-60-UV-24\ADIW, the conduit knockout test was not conducted. The suitability is to be determined in end product. 10. In the end product, LED driver spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 11. In the end product, LED Drivers shall be located not less than 1 inch (25.4 mm) apart when arranged end-to-end, and not less than 4 inches (102 mm) apart when arranged otherwise. KING BILLION (ASIA) LTD E362583 UNIT A 3/F CHEONG SUN TOWER 116-118 WING LOK ST SHEUNG WAN, HONG KONG Class 2 LED Modules, designated as XXXX YYYYD/M series, where XXXX and YYYY may be combinations of any numbers. 1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less. 2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy limited circuits. 3. When these units are connected to a Class 2 supply circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means available. KOLEDO INTERNATIONAL BV EKKERSRIJT 7051 E346915 5692 HB SON EN BREUGEL, THE NETHERLANDS LED Light Strings, LED Strings Series 12NC - "Affinium High Powered LED Light Strings", Part Nos. 9290 004 61903, 9290 004 62103, 9290 004 62203,9290 004 62303,9290 004 62403. 1. These components are only suitable for connection to a UL Listed or R/C (UYMR2), Component - Sign Accessory Class 2 power source, rated 30V DC or less. 2. These components have not been evaluated for use and connection to a power source supply with outputs parameters exceeding the limitations for a Class 2 circuit. 3. Class 2 LED Strings when connected to a Class 2 source, are not to draw a total current or wattage of greater than the secondary or output rating of the Class 2 circuit. 4. These components are suitable for use in Dry, Damp, and wet locations and are not and are not required to be enclosed or protected from the weather in the end product when connected to Class 2 source of supply with 30 V DC or less maximum voltage. 5. These products described in this section may be cut into segments per manufacture's installation instructions. LED Posterbox modules, Models LPM8W6300K325mm (12.8")300, LPM13W6300K565mm (22.2")300, LPM8W6300K565mm (22,2")300, LPM6W6300K325mm (12.8")300, LPM8W4000K325mm(12.8")330, LPM13W4000K565mm(22.2")300 or Alternate Catalog Numbers: 9290 004 834,9290 004 835,9290 004 836,9290 004 837,9290 006 007,9290 006 008. Models LPM6300K 371 mm 4leds 400, LPM6300K 565mm 6leds 400, LPM2700K 371 mm 4leds 400, LPM2700K 565mm 6leds 400, LPM4000K N O (09+ 112 T 9'6" 1662 L 5-9 r=Illi 12'46"Total Area: 21.1 sq.ft Wall LEDJob Address:Plexlglas face with 3/4" Trim-cap. 5015 W. Edinger Ave., #J #14SS Screws X 3" VW - Channel Letter (Return) Minimum 4 Per Latter. /2013 11:44 . ti;.Santa Ana, CA 92704 120 VAC to 12VDC LED .TO WIRING lilli CON.U. Dfna -17 Transformer 1/4" Drain Holes -. .21' Side View Illuminated Channel Letter Detail i I W 4-f + -Ck '7Pqi ». 2{.f?,< p . .2431) English Ldtte'r x7IlluMin'ated;Channel Letter withr1184ed hclyliclfdo«,-314;i@elet*im-Gap, 5" black returns, red LED for illumination.2013- ,ST£i LEt'LuCLIllei„=I&,981,nellogerwith-1 /8"(0913 1 1Ubite-acrilic focc, stick vifiFI-grriphice-on-top to**r[04*QD·/i -- -ANNER / 62_/r A ' DATE 7-14 -/3. 1 *SFERRED BY DATE ----- Pt/INNINg,1860§6JAEIM:REQUIRED:Date: ROUGH- FINAL- NONE / NAME_-__ -- ...(714) - RETAIN PLANE 7OR FUTURE REViSIONS.SUBJECT TO :TUMS CHECKED AND CONDITIONSBELOW: O INTER! 07 11 0"ILY O NO ED TER 13 2.LTERATIONS/MODIFICATIONSO ALL Mt· .L .:ALS TO MATCH EXISTINGO SCRE.EN:NG REQUIRED O SULMIT LANDSCAPE PLANS . CONDITIONS: A/•.1 43741 5 70. , ,£4-·1ti 1 'Cl" EUCLID ST. 323'-3 22'-C6 BUILDING SF: 80,400 BUILDING SF/1,000=80.4 EXISnNG PARKING EXISTING STANDARD: 414 28'-0- e 181 j 1 1111111 M f 160'-0- 1 111111@1111111111111 1 - 0-LE-80 231¥OSalva 1111 Il EXISnNG VAN ./t•.30 EMISTING,•aTORr tn' 'n' * hACCESSIBLE: 8 BlaDING'I 106'-1- .1 25'-58'-f'233'-0 1BCU 9'|12 TOTAL PARKING SPACES EXISTING: 422 PER THOUSAND: 5.2 0 lili 1111110 11111IU 0 2' 6 11111 Ifi 11@1- U 1111 I'llill U 65'-0 68'-0-11 r % 0 - „.. .tz'. 107 "„0 155'-(7 111111 I W 11110 l i l i lillil 1 lilli 8-59'-0 38'-" lili--0 02' 015'-C 111111110111110 1111111 FIEIIIW 1. F 11 % Ill'b 111'P lilile lili P I'llp 44'-6' tillie 2' 1 .1 4 IlllIllwIllilf 23'-0 75'- 111'llp111111.7it-JI111111°111111Uillillilld 0074 0.65'-C 11'la 59'-6Pm)111111-1 1 luE I . 160 eI J 111 QI 1€LT,1 ki- -v - FRE UNE *= U.- 7., 26'-0-18'-0.7 Ts-o·Gm ht 44F'b- 4 f 0 =1 m:*0 .4.... 17*1.:00. ,=.1.mol 1.100. =. ....1...„10. h. 1 n 1 11 1 11 9%4 1111@11111.:!3 \#»t....17 -PROPERTY UNE Pt.AfirTER h 103rObld d *311VA SSBHOOV 452'-El 3' -6'20 85'-0'8'-0 12' 12 00 572'-0 6663 LONG BEACH BLVD. 15972 EUCLID ST.-92708 NTS Mm I:I 05 0:25&&620 5015-5127 W. EDINGER AVE.-92704 (877) 439-7130 FOUNTAIN VALLEY-CA 1 8-9-13 /Ol '79 333015 23 1 9 50\ S -,.- ia, CBC & CEC 2010 Apvlinimum (4} screws per letter,/ maximum 24" on center, 2"penetration, #10 sheet metal screws, & (2) 14" drain holes per letterments\gn@\s13 A local disco .requird or the dedicated circuit breaker(s) musff position.- be individul lockable intheo attic or aboveFC 600-6 W\0 3b* USS to any ?cmer supp frornceiling shall be immediately a ladder orwith a2x3 foot access door & passage with-inch walkway. CEC 600-21 (d)(d)of Santa Ana Planning & Building Agency12 PERMITTYPE:(399 (&65¢T PLBGELECTRICAL PLAN APPROVAL t1 This set of plans and specifications must be kept on the job at all times and it is unlawful to make any changes or alteratlons on same without written per- mission from the Department of Building Safety - City of Santa Ana. The approval of this plan and specifications SHALL NOT bo held to permit nor be an approval of the violation or any provisions of ANY City Ordinance MECH GRADING PERMIT#181/93€8/ROE>RE'773-OCC. GROUP CONSTR. TYPF CODE EDITION 2 0 FO FLOOD ZONE or State Law. FLOOD ZONE CERTIF. REQ'D YES NO-Approveby-NNY5= 9146 MICROFILM YES NOpWITY OF SANTAANADEPARTMENT OF BUILDING SAFETY 1 RADIANT BARRIER @ROOF YES c'RIO RESIDENTIAL DEV. FEE YES NO SCHOOL DISTRICT YES NO . '44