Loading...
HomeMy WebLinkAbout1006 S Austin St - Plan          5HY1                                                                                                                                                                                                          6XQ3RZHU3URSULHWDU\  /LVWLQJV&RPSDWLELOLW\D QG&ODVVLILFDWLRQ 7KH6XQ3RZHUΖQYLVL0RXQW5HVLGHQWLDO0RXQWLQJ6\VWHP LV8/ /LVWHG7KHΖQYLVL0RXQW/LVWLQJLQFOXGHVWKH IROORZLQJPRGXOHVZKLFKKDYHEHHQWHVWHGIRUJURXQGLQJDQGPHFKDQLFDOORDGZLWKWKHΖQYLVL0RXQWV\VWHP )RUFHUWLILFDWLRQLQIRUPDWLRQDFFHVVWKH8/VLWHKWWSVZZZXOFRP  RUWKH8/ SRUWDOKWWSVZZZXOFRPUHVRXUFHVDSSVP\XOFOLHQWSRUWDODQGYLHZ )LOH(DQG)LOH( :LWK&ODVVLFΖQYLVL0RXQW 6XQ3RZHU'&0RGXOHV6XQ3RZHU$&0RGXOHV • 635$%/.'& • 635$'& • 635$'& • 635( • 635( • 635;%/.  • 635;%/.  • 635; • 635; • 635;  • 635$%/.*$& • 635$*$& • 635$*$& • 635$*$& • 635$*$& • 635$*$& • 6350%/.+$& • 6350%/.+$& • 6350+$& • 6350+$& • 6350+$&   • 635;($& • 635;($& • 635;%/.($& • 635;%/.($& • 635;%/.($& • 635;($& • 635;($& • 635;($& • 635(($& • 635(($&  :LWK8QLYHUVDOΖQYLVL0RXQW 0D QXIDFWXUHU0RGXOH0RGHO6HULHV 6XQ3RZHU • 635$[[[&20 PD\EHIROORZHGE\%/. ZKHUH[[[FDQEHȂ • 635$[[[\\\0/6'ZKHUH[[[FDQEHȂDQGZKHUH \\\FDQEH  &20DQGRU9 $SWRV  • '1$0)[:ZKHUH[[[LVZDWWDJH • '1$%)[[[:ZKHUH[[[LVZDWWDJH • '1$)[[: ZKHUH [[[LVȂ +DQZKD • 43($. '82%/. 0/*D[[[ZKHUH[[[FDQEHȂ            5HY1                                                                                                                                                                                                          6XQ3RZHU3URSULHWDU\ 5(&  • 5(&[[[13ZKHUH[[[FDQEHȂ • 5(&[[[13%ODFNZKHUH[[[FDQEHȂ • 5(&[[[73ZKHUH[[[FDQEHȂ • 5(&[[[73%ODFNZKHUH[[[FDQEHȂ • 5(&[[[$$ZKHUH[[[FDQEHȂ • 5(&[[[$$%ODFNZKHUH[[[FDQEHȂ • 5(&[[[$$3XUHZKHUH[[[FDQEHȂ  7ULQD • 760[[['(; ΖΖ ZKHUH[[[FDQEHȂ -LQNR • -.0[[[05/%ZKHUH[[[FDQEHȂ &DQDGLDQ 6RODU • &DQDGLDQ6RODU&61[[[06ZKHUH[[[LV :DDUHH   • :60'L[[[ZKHUH [[[LV  &HUWLILFDWLRQSHQGLQJ  6\VWHP 'HVLJQ/RDG5DWLQJ36)GRZQZDUG36)XSZDUG36) ODWHUDO$FWXDOV\VWHPVWUXFWXUDOFDSDFLW\LV GHILQHGE\WKHΖQYLVL0RXQW6SDQ7DEOHV *URXQGLQJIURP WKHPRGXOHWRWKHUDLOLVDFFRPSOLVKHGWKURXJKWKHFODPSV6HH6HFWLRQIRUPRUHLQIRUPDWLRQ 7KH/LVWLQJDOVRLQFOXGHVWKHIROORZLQJFRPSRQHQWVZKLFKKDYHEHHQHYDOXDWHGIRUERWKPRXQWLQJDQGERQGLQJLQ DFFRUGDQFHZLWK8/ • (QGFODPS • 0LGFODPS • 5DLO • 6SOLFHDQGVSOLFHVFUHZ • *URXQGOXJDVVHPEO\ • /IRRW • 5RZWRURZ  55 JURXQGLQJFOLS • 5RZWRURZ  55 JURXQGLQJMXPSHU • 5RZWRURZ  55 VSDFHU • 5DLOPRXQWHGJURXQGLQJMXQFWLRQER[ 50-  1006 S Austin St 11/29/22           5HY1                                                                                                                                                                                                          6XQ3RZHU3URSULHWDU\  )LUH&ODVVLILFDWLRQ • 7KHPD[LPXP GLVWDQFHEHWZHHQWKHURRIGHFNDQG WKHERWWRP RIWKHPRGXOHIUDPHLVȋ FP  • ΖQRUGHUWRPDLQWDLQWKHV\VWHP FODVVLILFDWLRQWKLVDVVHPEO\PXVWEHPRXQWHG RYHUDILUH UHVLVWDQWURRIFRYHULQJ IRUWKHDSSOLFDWLRQ • 7KHV\VWHP DFKLHYHVD&ODVV$ILUHUDWLQJZKHQLQVWDOOHG ZLWKPRGXOHVKDYLQJD7\SHILUHFODVVLILFDWLRQ • 7KHV\VWHP DFKLHYHVD&ODVV$ILUHUDWLQJZKHQLQVWDOOHG LQWKHPDQQHUVSHFLILHG LQWKHVHLQVWUXFWLRQV • 7KHV\VWHP ZDVHYDOXDWHGIRUXVHRQURRIVRIDQ\VORSHLQFOXGLQJWKRVHZLWKQRVORSHDWDOO IODWURRIV  6\VWHP*URXQG 3DWK 7KHΖQYLVL0RXQWV\VWHP IHDWXUHV • ΖQWHJUDWHG PRGXOHWRUDLODVZHOODV DGMDFHQWPRGXOHERQGLQJ DFKLHYHG WKURXJKWKH&ODVVLFPLGFODPS&ODVVLF HQGFODPSDQG8QLYHUVDOPLGFODPS  • 1RWHWKDWWKH8QLYHUVDOHQGFODPSGRHVQRWSURYLGHERQGLQJIURP PRGXOHWRUDLO:KHQRQO\HQG FODPSVDUH XVHG WRDWWDFKDPRGXOHWRWKHUDLOV DURZ KDYLQJMXVWDVLQJOHPRGXOHDȊVWDQGDORQHȋPRGXOH WKHPRGXOH PXVWEHJURXQGHG VHSDUDWHO\ • ΖQWHJUDWHG UDLOWRUDLOERQGLQJ DFKLHYHGWKURXJKWKH VHOIGULOOLQJVSOLFHVFUHZVDQGWKHVSOLFH  • 6\VWHP ERQGLQJDFKLHYHGWKURXJKWKHHTXLSPHQWJURXQGFRQGXFWRU (*&  • )RUDUUD\VZKHUHWKHLQVWDOOHUFKRRVHVWRXVH55 JURXQGLQJFOLSVRUJURXQGLQJMXPSHUVLQVWHDGRIDGGLWLRQDO JURXQGOXJVDQGFRSSHUZLUHV\VWHP ERQGLQJLVDFKLHYHGWKURXJKWKHFOLSVDQGMXPSHUV 7KHIROORZLQJGLDJUDPVLOOXVWUDWHWKHNH\JURXQGLQJDQGERQGLQJDVSHFWVRI8QLYHUVDOΖQYLVL0RXQWDQGRI&ODVVLF ΖQYLVL0RXQW'LDJUDPVFRYHUERQGLQJZLWKDQGZLWKRXWWKHLUUHVSHFWLYHUDLOWRUDLOJURXQGLQJFRPSRQHQWVDVZHOODV ERQGLQJZLWKWKH50- • 7KHV\VWHP JURXQGSDWKLQFOXGLQJHDFKFRPSRQHQWDQGHDFKERQGLQJSRLQW • 7KHDSSOLFDEOH1(&DQG 8/UHIHUHQFHV 1RWH:KHQXVHG WKH50-UHSODFHVWKHUDLOJURXQGLQJOXJLQWKHERQGLQJSDWKΖI\RXGHFLGHWRXVHWKH MXQFWLRQER[VHH$SSHQGL[$IRULQVWDOODWLRQLQVWUXFWLRQVDQG WRUTXHYDOXHV ΖPSRUWDQW)RU8QLYHUVDOΖQYLVL0RXQWLQVWDOODWLRQVWKHPRGXOHOHYHOSRZHUHOHFWURQLFV 0/3( PRXQWKDUGZDUH 7 EROWDQGQXWDQG 0ΖEUDFNHW ERQGVWKHPLFURLQYHUWHU 0Ζ EUDFNHWWRWKHUDLO              5HY1                                                                                                                                                                                                          6XQ3RZHU3URSULHWDU\  1006 S Austin St 11/29/22            5HY1                                                                                                                                                                                                          6XQ3RZHU3URSULHWDU\              5HY1                                                                                                                                                                                                          6XQ3RZHU3URSULHWDU\   1006 S Austin St 11/29/22            5HY1                                                                                                                                                                                                          6XQ3RZHU3URSULHWDU\              5HY1                                                                                                                                                                                                          6XQ3RZHU3URSULHWDU\   1006 S Austin St 11/29/22            5HY1                                                                                                                                                                                                          6XQ3RZHU3URSULHWDU\    1006 S Austin St 11/29/22 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 1006 S. Austin 07/29/22 Expedited Permit Process for PV Systems — Micro-Inverter2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 1006 S. Austin 07/29/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan                                                        ECO SOLAR LE 13962 SEABOARD CIR GARDEN GROVE, CA. 92840 1006 AUSTIN STREET 714-265-9077 2.975 1006 S. Austin 07/29/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT ECO SOLAR 13962 SEABOARD CIR GARDEN GROVE, CA. 92840 LE 2.975 1006 AUSTIN STREET 714-265-9077 1006 S. Austin 07/29/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO- INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram ECO SOLAR 13962 SEABOARD CIR GARDEN GROVE, CA. 92840 714-265-9077 LE 1006 AUSTIN STREET 2.975 1006 S. Austin 07/29/22 SunPower ® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates even module spacing • Simple, pre-drilled rail splice • UL 2703 Listed integrated grounding Flexible Design • Addresses nearly all sloped residential roofs • Design in landscape and portrait • Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and #1 mounting aesthetics • Best-in-class system aesthetics ȏ Premium,low-proȴ ledesign • Black anodized components • Hidden mid clamps and end clamps  hardware,andcapped,ȵushrails Part of Superior System • Built for use with SunPower DC and AC modules • Best-in-class system reliability and aesthetics • Combine with SunPower modules and monitoring app sunpower.com Elegant Simplicity SunPower ® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installationtime,designȵexibility,and superioraesthetics. TheΖnvisiMountproductwasspeciȴcallyenvisionedand  engineered to pair with SunPower modules. The resulting system-level approach will amplify the aesthetic and installationbeneȴtsforbothhomeownersand installers. SunPower ® InvisiMount™ | Residential Mounting System InvisiMount Component Details Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug)106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) Roof Attachment Hardware Supported by InvisiMount System Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal Interface for Other Roof Attachments InvisiMount Operating Conditions Temperature ȫ40°Cto90°C(ȫ40°Fto194°F) Max. Load 2400 Pa uplift 5400 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation ΖnvisiMountWarrantiesAndCertiȴcations Warranties 25-year product warranty 5-yearȴnishwarranty Certiȴcations UL 2703 Listed ClassAȴreratingwhendistancebetween roof surface and bottom of SunPower moduleframeisȱ3.5ȋ *Module frame that is compatible with the InvisiMount system required for hardware interoperability. © 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. Speciȴcationsincludedinthisdatasheetaresubjecttochangewithoutnotice. InvisiMount Component Images Module* / Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap Module* / End Clamp and Rail sunpower.com Document #509506 Rev B 1006 S Austin St 11/29/22 SunPower ® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates even module spacing • Simple, pre-drilled rail splice • UL 2703 Listed integrated grounding Flexible Design • Addresses nearly all sloped residential roofs • Design in landscape and portrait • Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and #1 mounting aesthetics • Best-in-class system aesthetics ȏ Premium,low-proȴ ledesign • Black anodized components • Hidden mid clamps and end clamps  hardware,andcapped,ȵushrails Part of Superior System • Built for use with SunPower DC and AC modules • Best-in-class system reliability and aesthetics • Combine with SunPower modules and monitoring app sunpower.com Elegant Simplicity SunPower ® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installationtime,designȵexibility,and superioraesthetics. TheΖnvisiMountproductwasspeciȴcallyenvisionedand  engineered to pair with SunPower modules. The resulting system-level approach will amplify the aesthetic and installationbeneȴtsforbothhomeownersand installers. SunPower ® InvisiMount™ | Residential Mounting System InvisiMount Component Details Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug)106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) Roof Attachment Hardware Supported by InvisiMount System Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal Interface for Other Roof Attachments InvisiMount Operating Conditions Temperature ȫ40°Cto90°C(ȫ40°Fto194°F) Max. Load 2400 Pa uplift 5400 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation ΖnvisiMountWarrantiesAndCertiȴcations Warranties 25-year product warranty 5-yearȴnishwarranty Certiȴcations UL 2703 Listed ClassAȴreratingwhendistancebetween roof surface and bottom of SunPower moduleframeisȱ3.5ȋ *Module frame that is compatible with the InvisiMount system required for hardware interoperability. © 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. Speciȴcationsincludedinthisdatasheetaresubjecttochangewithoutnotice. InvisiMount Component Images Module* / Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap Module* / End Clamp and Rail sunpower.com Document #509506 Rev B 1006 S. Austin 07/29/22 1006 S Austin St 11/29/22 1006 S. Austin 07/29/22 HOMEOWNER: THANH LE PH: 714.722.8071 ADDRESS: 1006 S. AUSTIN STREET SANTA ANA, CA 92704 DATE: 11/4/22DATE: 11/4/22 ECOSOLAR USA ELECTRICAL LLC 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 SCO3E O) :OR. INSTALL (7) SUNPOWER SPR-M425-H-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL. ELECTRICAL LI1 E 'IA*RA0 S+EET 1OTICE A1 < C+A1*ES TO OR USES O ) T+ESE 'OCU0E1TS'RA:I1*S :IT+OUT T+E :RITTE1 CO1SE1T O) -E11I)ER .E00E OR SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE'  O)  PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 MAIN SERVICE INFO: 100 A, 120/240 VAC, 1Ø, 3-WIRE 100A EXISTING BUILDING GROUNDING ELECTRODE SYSTEM M EXISTING SERVICE PANEL: 100 A BUS RATED, 240 VAC, 1Ø G L1 L2 60 A, 240 VAC, 1Ø AC DISCONNECT LOCKABLE, VISIBLE KNIFE-BLADE TYPE (3) 10 AWG THWN-2 & (1) 10 AWG GROUND IN 3 4" EMT CONDUIT 89033PVR1 SOURCE CIRCUIT #1: 7 MODULES, 240 VAC L1 L2 L1 L2 L1 L2 NEMA 3R, 240 VAC JUNCTION BOX (2) 10 AWG THWN-2 & (1) 10 AWG GROUND IN 3 4" EMT CONDUIT + - + - + - USE SUNPOWER INTEGRATED GROUNDING TO GROUND ALL MODULES, JUNCTION BOXES AND ANY OTHER METAL PARTS AND GROUND LUGS WITH #6 AWG SOLID COPPER WHERE NEEDED SUNPOWER SPR-M425-H-AC SUNPOWER SPR-M425-H-AC SUNPOWER SPR-M425-H-AC EXISTING SUB PANEL: 100 A BUS RATED 240 VAC, 1Ø 20A 20A TO M O N I T O R I N G NOTE: QUAD BREAKER FOR SOLAR AND MONITORING. 100A 100A NOTE: PHOTOVOLTAIC MODULE HAS AN INTEGRATED MICROINVERTER NOTE: THE INVISIMOUNT SYSTEM IS LISTED TO UL 2703 FOR INTEGRATED GROUNDING; SUNPOWER AC MODULES ARE A BONDING COMPONENT AND ARE LISTED TO UL 1741. INSTALLING SUNPOWER AC MODULES ON THE INVISIMOUNT SYSTEM (OR ANY MOUNTING SYSTEM THAT IS LISTED TO UL 2703 FOR BONDING-NOT JUST FOR FIRE CLASSIFICATION), NO ADDITIONAL GROUNDING HARDWARE, LUGS, OR COPPER WIRE ARE REQUIRED ON THE ROOF. SEE INVISIMOUNT SPEC SHEET PAGES WITHIN THIS PLAN SET. 12 AWG PV IN AIR (TYP) CONDUIT MUST BE SUPPORTED A MINIMUM OF 7 8" ABOVE THE ROOF SURFACE. BILL OF MATERIAL MATERIAL TYPE QTY PV PANEL SUNPOWER SPR-M425-H-AC 7 TRUNK CABLE LANDSCAPE 7 FOOTINGS UNIRAC FLASHLOC 12 RAILING INVISIMOUNT 5 GROUNDING ROW INVISIMOUNT 1 GROUND LUG W/DISC INVISIMOUNT 1 MID CLAMPS INVISIMOUNT 12 END CLAMPS INVISIMOUNT 6 RAIL SPLICE INVISIMOUNT 2 ROW SPACERS INVISIMOUNT 2 MONITOR PVS6 1 CON CT / PRO CT KIT 1 TERMINATOR CAPS 1 DISCONNECT 60 A SIEMENS 1 FUSES 0 LOAD CENTER 125 A SIEMENS 8/16 0 BREAKERS SIEMENS 2-POLE 15A 0 SIEMENS 2-POLE 20A/20A 1 SIEMENS 2-POLE 40A 0 BATTERY PACKAGE SUNVAULT 0 1006 S Austin St 11/29/22 HOMEOWNER: THANH LE PH: 714.722.8071 ADDRESS: 1006 S. AUSTIN STREET SANTA ANA, CA 92704 DATE: 6/2/22DATE: 6/2/22 ECOSOLAR USA ELECTRICAL LLC 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 SCO3E O) :OR. INSTALL (7) SUNPOWER SPR-M425-H-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. ELECTRICAL LI1E 'IA*RA0 S+EET 1OTICE A1 < C+A1*ES TO OR USES O ) T+ESE 'OCU0E1TS'RA:I1*S :IT+OUT T+E :RITTE1 CO1SE1T O) -E11I)ER .E00E OR SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE'  O)  PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 MAIN SERVICE INFO: 100 A, 120/240 VAC, 1Ø, 3-WIRE METER #222012-788221 20A 100A EXISTING BUILDING GROUNDING ELECTRODE SYSTEM M EXISTING SERVICE PANEL: 100 A BUS RATED, 240 VAC, 1Ø G L1 L2 60 A, 240 VAC, 1Ø AC DISCONNECT LOCKABLE, VISIBLE KNIFE-BLADE TYPE (3) 12 AWG THWN-2 & (1) 12 AWG GROUND IN 1 2" EMT CONDUIT 89033PV SOURCE CIRCUIT #1: 7 MODULES, 240 VAC L1 L2 L1 L2 L1 L2 NEMA 3R, 240 VAC JUNCTION BOX (2) 12 AWG THWN-2 & (1) 12 AWG GROUND IN 1 2" EMT CONDUIT + - + - + - 12 AWG (TYP) USE SUNPOWER INTEGRATED GROUNDING TO GROUND ALL MODULES, JUNCTION BOXES AND ANY OTHER METAL PARTS AND GROUND LUGS WITH #6 AWG SOLID COPPER WHERE NEEDED SUNPOWER SPR-M425-H-AC SUNPOWER SPR-M425-H-AC SUNPOWER SPR-M425-H-AC 20A TO M O N I T O R I N G NOTE: QUAD BREAKER FOR SOLAR AND MONITORING. 1006 S. Austin 07/29/22 HOMEOWNER: THANH LE PH: 714.722.8071 ADDRESS: 1006 S. AUSTIN STREET SANTA ANA, CA 92704 DATE: 11/4/22DATE: 11/4/22 ECOSOLAR USA ELECTRICAL LLC 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 SCO3E O) :OR. INSTALL (7) SUNPOWER SPR-M425-H-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL. NOTE: DIMENSIONS AND FEATURES SHOWN ARE CLOSE TO SCALE BUT WERE TAKEN FROM A FIELD SURVEY AND APPROXIMATIONS MADE USING GOOGLE EARTH. (E) 100 AMP SUB PANEL S A U S T I 1 S T R E E T N SCALE: 1/16"=1' 8 16 32 48 (N) AC DISCONNECT SITEROO) 3LA1 ARRAY #1: (7) MODULES TILT = 20°, AZ = 180° 2 S+EET 1OTICE A1 < C+A1*ES TO OR USES O ) T+ESE 'OCU0E1TS'RA:I1*S :IT+OUT T+E :RITTE1 CO1SE1T O) -E11I)ER .E00E OR SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE'  O)  PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 1.5' FIRE CLEARANCE 89033PVR1 TOTAL ROOF AREA = 1435 SF TOTAL SOLAR AREA = 145 SF 145 SF/1435 SF = 0.10 ARRAYS COVER 10% OF TOTAL ROOF AREA EXISTING 1-STORY ROOF: COMPOSITION SHINGLE, FELT & 1 2" SHEATHING OVER RAFTERS EXISTING 2 X 4 RAFTERS @ 24" OC MODULES: 73.7" X 40.6" 48.0 LBS EACH SUNPOWER INVISIMOUNT RAIL MOUNTING SYSTEM WITH UNIRAC FLASHLOC ROOF ATTACHMENTS (USE 5 16" STAINLESS STEEL LAG BOLTS @ 72" OC OR LESS WITH A MINIMUM EMBEDMENT OF 21 2" INTO ROOF RAFTERS), WATERPROOF ALL CONNECTION LOCATIONS PER MANUFACTURER'S INSTRUCTIONS 3" MIN. 8" MAX. NTS ELE9ATIO1 'ETAIL : .E1T A9E1UE PROPERTY LINE PROPERTY LINE VENT (TYP) 3 4 5 6 7 1 12'-4" 23'-11" 6'-3" 17'18'-7" (E) 100 AMP MAIN SERVICE PANEL 1006 S Austin St 11/29/22 HOMEOWNER: THANH LE PH: 714.722.8071 ADDRESS: 1006 S. AUSTIN STREET SANTA ANA, CA 92704 DATE: 6/2/22DATE: 6/2/22 ECOSOLAR USA ELECTRICAL LLC 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 SCO3E O) :OR. INSTALL (7) SUNPOWER SPR-M425-H-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. NOTE: DIMENSIONS AND FEATURES SHOWN ARE CLOSE TO SCALE BUT WERE TAKEN FROM A FIELD SURVEY AND APPROXIMATIONS MADE USING GOOGLE EARTH. (E) 100 AMP MAIN SERVICE PANEL S A U S T I 1 S T R E E T N SCALE: 1/16"=1' 8 16 32 48 (N) AC DISCONNECT SITEROO) 3LA1 ARRAY #1: (7) MODULES TILT = 20°, AZ = 180° 2 S+EET 1OTICE A1 < C+A1*ES TO OR USES O ) T+ESE 'OCU0E1TS'RA:I1*S :IT+OUT T+E :RITTE1 CO1SE1T O) -E11I)ER .E00E OR SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE'  O)  PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 1.5' FIRE CLEARANCE 89033PV TOTAL ROOF AREA = 1435 SF TOTAL SOLAR AREA = 145 SF 145 SF/1435 SF = 0.10 ARRAYS COVER 10% OF TOTAL ROOF AREA EXISTING 1-STORY ROOF: COMPOSITION SHINGLE, FELT & 1 2" SHEATHING OVER RAFTERS EXISTING 2 X 4 RAFTERS @ 24" OC MODULES: 73.7" X 40.6" 48.0 LBS EACH SUNPOWER INVISIMOUNT RAIL MOUNTING SYSTEM WITH UNIRAC FLASHKIT PRO ROOF ATTACHMENTS (USE 5 16" STAINLESS STEEL LAG BOLTS @ 72" OC OR LESS WITH A MINIMUM EMBEDMENT OF 212" INTO ROOF RAFTERS), WATERPROOF ALL CONNECTION LOCATIONS PER MANUFACTURER'S INSTRUCTIONS 3" MIN. 8" MAX. NTS ELE9ATIO1 'ETAIL : .E1T A9E1UE PROPERTY LINE PROPERTY LINE VENT (TYP) 3 4 5 6 7 1 60'-7" 12'-4" 23'-11" 6'-3" 1006 S. Austin 07/29/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1006 S. AUSTIN ST ECO SOLAR 1045300 X X X X X X X X X X JENNIFER KEMME 909-748-1300 sherrymanley@visionce.com 07/06/2022 1006 S. Austin 07/29/22 STRUCTURAL ANALYSIS FOR NEW PHOTOVOLTAIC SOLAR SYSTEM NOTE: THESE CALCULATIONS ARE BASED ON INFORMATION AND MEASUREMENTS PROVIDED BY THE CONTRACTOR FROM HIS SITE INSPECTION. 1 Project Information:PV SOLAR ARRAY: LE RESIDENCE Latitude 33.7342° deg N 1006 S. AUSTIN STREET, SANTA ANA, CA 92704 Longitude -117.933° deg W Wind Speed 110 mph 95 mph (ASCE 7-16) Wind Exposure C Site Class D Seismic Design Category D 2 Loads: Existing Roof Dead Loads: 2 x 4 Rafters @ 24" OC 0.7 psf 1/2" Roof Sheathing 1.7 psf Roof Felt 1.5 psf Composition 5.0 psf Miscellaneous 3.1 psf Total 12.0 psf Existing Snow Load:0.0 psf Existing Roof Live Load:20.0 psf Proposed Roof Live Load:20.0 psf Wind Load: Using CBC 2019 (ASCE 7-16), Chapter 29: Wind Loads on Rooftop Equipment, the following wind pressures were calculated. p = qh (GCp) (ge) (ga) = 8.79 -45.19 psf qh = 0.00256 Kz Kzt Kd Ke V2 = 21.76 psf Kz = 0.85 (0-15 = 0.85, 20 = 0.90, 25 = 0.94, 30 = 0.98, 40 = 1.04) GCp = 0.7 -3.6 (Roof pitch = 20 deg, Zone = 2, Aeff = 20.8 sf) ge = 1.50 ga = 0.80 Lag Bolt Capacity: 5/16" lag bolt capacity = 270 lbs per inch embedment With 2 1/2" minimum embedment, capacity = 675 lbs Required Capacity: 45.19 psf * 7 modules * 20.8 sf = 6580.2 lbs 6580.2 lbs / 12 lag bolt connections = 548.4 lbs The pull-out capacity of the 5/16" lag bolts with a minimum 2 1/2" embedment into the roof rafter is sufficient to meet the demand of the wind uplift force on the solar system. Seismic Load: Per the CEBC 2019 Section 503.4, if the demand-capacity ratio of the lateral load-carrying elements increases less than 10% due to the addition of the solar system, no special provisions or structural modifications are required. Existing Roof Weight = 12.0 psf * 1435 sf = 17220 lbs Weight of Solar System = 7 modules * 48.0 lbs + 73 lbs of racking = 409 lbs 409 lbs / 17220 lbs = 0.02 The increase in load from the solar system will not increase the demand-capacity ratio of the existing lateral load-carrying elements by over 10%. NOTICE:VISION CIVIL ENGINEERING: JENNIFER KEMME, PE ANY CHANGES TO OR USES OF THESE DOCUMENTS 12273 11TH STREET, YUCAIPA, CA 92399 WITHOUT THE WRITTEN CONSENT OF VISION 909.754.8300, JENKEMME@VISIONCE.COM CIVIL ENGINEERING IS STRICTLY PROHIBITED.RCE 73054, EXP 12/31/22 Prepared by JENNIFER KEMME 6/29/2022 Page 1 1006 S. Austin 07/29/22 STRUCTURAL ANALYSIS FOR NEW PHOTOVOLTAIC SOLAR SYSTEM NOTE: THESE CALCULATIONS ARE BASED ON INFORMATION AND MEASUREMENTS PROVIDED BY THE CONTRACTOR FROM HIS SITE INSPECTION. 3 Analysis of Existing Rafter Capacity:PV SOLAR ARRAY: LE RESIDENCE 1006 S. AUSTIN STREET, SANTA ANA, CA 92704 Rafter Loads: Solar system dead load = 409 lbs / 12 lag bolts total = 34.1 lbs at each lag bolt Existing roof dead load = 12 psf Snow load = 0 psf Roof live load = 20 psf Wind load = 106.6 lbs, 548.4 lbs Rafter span = 7.0 ft Load Combinations That Apply: #1: D + Lr or S = 12 psf + 34.1 lbs at each lag bolt + 20.0 psf #2: D + 0.75(0.6W) + 0.75(Lr or S) = 12 psf + 34.1 lbs at each lag bolt) + (0.75 (0.6) 106.6 lbs at each lag bolt) + (0.75 ( 20 psf)) #3: 0.6D + 0.6W = 0.6 ( 12 psf + 34.1 lbs at each lag bolt) - (0.6) 548.4 lbs at each lag bolt Calculated Maximum Bending Moment: #1: 196.0 ft/lbs + 59.6 ft/lbs = 255.6 ft/lbs [( 32 psf) ( 7 ft^2)] / 8 = 196.0 ft/lbs [( 34.07 lbs) ( 7.0 ft)] / 4 = 59.6 ft/lbs #2: 73.5 ft/lbs + 59.6 ft/lbs + 84.0 ft/lbs + 91.9 ft/lbs = 309.0 ft/lbs [( 12 psf) ( 7 ft^2)] / 8 = 73.5 ft/lbs [( 34.07 lbs) ( 7.0 ft)] / 4 = 59.6 ft/lbs 106.6 lbs) ( 7 ft)] / 4 = 84.0 ft/lbs 0.75 [( 20 psf) ( 7 ft^2)] / 8 = 91.9 ft/lbs #3: 44.1 ft/lbs + 35.8 ft/lbs - 575.8 ft/lbs = -495.9 ft/lbs 0.6 [( 12 psf) ( 7 ft^2)] / 8 = 44.1 ft/lbs 0.6 [( 34.07 lbs) ( 7.0 ft)] / 4 = 35.8 ft/lbs 0.6 [( 548.4 lbs) ( 7 ft)] / 4 = 575.8 ft/lbs Section Required: 495.9 ft/lbs (12) (0.7) / 1518 psi = 2.7 cu in Section Provided: 1.5 ( 3.5 ^2) / 6 = 3.1 cu in 3.1 cu in > 2.7 cu in, OK Calculated Deflection: [5( 32 psf / 12) ( 84 in^4)] / [384 (1200000) ( 5.4 )] = 0.27 in Allowable Deflection: 84 in / 240 = 0.35 in 0.35 in > 0.27 in, OK NOTICE: VISION CIVIL ENGINEERING: JENNIFER KEMME, PE ANY CHANGES TO OR USES OF THESE DOCUMENTS 12273 11TH STREET, YUCAIPA, CA 92399 WITHOUT THE WRITTEN CONSENT OF VISION 909.754.8300, JENKEMME@VISIONCE.COM CIVIL ENGINEERING IS STRICTLY PROHIBITED. RCE 73054, EXP 12/31/22 0.75 [(0.6)( Prepared by JENNIFER KEMME 6/29/2022 Page 2 1006 S. Austin 07/29/22 HOMEOWNER: THANH LE PH: 714.722.8071 ADDRESS: 1006 S. AUSTIN STREET SANTA ANA, CA 92704 DATE: 11/4/22DATE: 11/4/22 ECOSOLAR USA ELECTRICAL LLC 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 SCO3E O) :OR. INSTALL (7) SUNPOWER SPR-M425-H-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL. S<STE 0 SI*1A*E ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND ATTACHED WITH WEATHERPROOF ADHESIVE OR OTHER APPROVED METHOD. ALL LETTERS SHALL BE A MINIMUM OF 3 8" HEIGHT AND ALL CAPITALIZED. ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES SHALL BE MARKED AT 10' MAX INTERVALS AND AT ALL BENDS, TERMINATIONS, SPLICES OR CONNECTIONS WITH "WARNING: PHOTOVOLTAIC POWER SOURCE". WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION TO BE INSTALLED AT ALL SERVICEABLE PANELS OR BOXES AND AT ALL DISCONNECTS: SERVICE POINT & UTILITY METERING PV SYSTEM DISCONNECT FOR UTILITY OPERATION CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN. ADDRESS: 1006 S. AUSTIN STREET, SANTA ANA, CA 92704 SOLAR ARRAY (ON ROOF)N TO BE INSTALLED ON THE OUTSIDE COVER OF THE MAIN SERVICE DISCONNECT: RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM RATED AC OUTPUT CURRENT = 14.00 A NOMINAL OPERATING AC VOLTAGE = 240 V TO BE INSTALLED ON THE FRONT OF THE AC DISCONNECT: WARNING POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE TO BE INSTALLED AT THE BACKFED BREAKER SERVING THE PV SOLAR SYSTEM: TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TO BE INSTALLED ON THE FRONT OF THE MAIN SERVICE DISCONNECT: "SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN" SHALL BE BLACK LETTERING ON YELLOW BACKGROUND. THE REMAINDER OF THE SIGN SHALL BE BLACK LETTERING ON WHITE BACKGROUND. S+EET 1OTICE A1 < C+A1*ES TO OR USES O ) T+ESE 'OCU0E1TS'RA:I1*S :IT+OUT T+E :RITTE1 CO1SE1T O) -E11I)ER .E00E OR SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE'  O)  PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 S<STE 0 CALCULATIO1S NUMBER OF MODULES IN EACH CIRCUIT = 7 MODULE MAX OUTPUT CURRENT = 1.60 A (7) (1.60 A) (1.25) = 14.00 A [I], USE 20 A BREAKER MAIN SERVICE PANEL BUS RATING = 100 A MAIN SERVICE PANEL MAIN OCPD = 100 A 100 A + 20 A SOLAR OCPD = 120 A 100 A BUS (1.2) = 120 A 120 A = 120 A, OK 89033PVR1 :IRE CALCULATIO1S FROM THE MODULES TO THE MAIN SERVICE PANEL: AMBIENT TEMPERATURE = 34°C TEMPERATURE ADDER FOR CONDUIT OFFSET FROM ROOF BY MIN 7 8" = 0°C ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT 34°C + 0°C = 34°C = 0.96 I = 14.00 A 14.00 A/0.96 = 14.58 A SELECT WIRE SIZE WITH AMPACITY GREATER THAN 14.58 A, USE 10 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 40 A SELECT CONDUIT FOR (2) 10 AWG THWN-2 & (1) 10 AWG GROUND = 3 4" EMT CONDUIT SUB PANEL 1006 S Austin St 11/29/22 HOMEOWNER: THANH LE PH: 714.722.8071 ADDRESS: 1006 S. AUSTIN STREET SANTA ANA, CA 92704 DATE: 6/2/22DATE: 6/2/22 ECOSOLAR USA ELECTRICAL LLC 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 SCO3E O) :OR. INSTALL (7) SUNPOWER SPR-M425-H-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. S<STE 0 SI*1A*E ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND ATTACHED WITH WEATHERPROOF ADHESIVE OR OTHER APPROVED METHOD. ALL LETTERS SHALL BE A MINIMUM OF 3 8" HEIGHT AND ALL CAPITALIZED. ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES SHALL BE MARKED AT 10' MAX INTERVALS AND AT ALL BENDS, TERMINATIONS, SPLICES OR CONNECTIONS WITH "WARNING: PHOTOVOLTAIC POWER SOURCE". WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION TO BE INSTALLED AT ALL SERVICEABLE PANELS OR BOXES AND AT ALL DISCONNECTS: SERVICE POINT & UTILITY METERING PV SYSTEM DISCONNECT FOR UTILITY OPERATION CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN. ADDRESS: 1006 S. AUSTIN STREET, SANTA ANA, CA 92704 SOLAR ARRAY (ON ROOF)N TO BE INSTALLED ON THE OUTSIDE COVER OF THE MAIN SERVICE DISCONNECT: RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM RATED AC OUTPUT CURRENT = 14.00 A NOMINAL OPERATING AC VOLTAGE = 240 V TO BE INSTALLED ON THE FRONT OF THE AC DISCONNECT: WARNING POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE TO BE INSTALLED AT THE BACKFED BREAKER SERVING THE PV SOLAR SYSTEM: TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TO BE INSTALLED ON THE FRONT OF THE MAIN SERVICE DISCONNECT: "SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN" SHALL BE BLACK LETTERING ON YELLOW BACKGROUND. THE REMAINDER OF THE SIGN SHALL BE BLACK LETTERING ON WHITE BACKGROUND. S+EET 1OTICE A1 < C+A1*ES TO OR USES O ) T+ESE 'OCU0E1TS'RA:I1*S :IT+OUT T+E :RITTE1 CO1SE1T O) -E11I)ER .E00E OR SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE'  O)  PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 S<STE 0 CALCULATIO1S NUMBER OF MODULES IN EACH CIRCUIT = 7 MODULE MAX OUTPUT CURRENT = 1.60 A (7) (1.60 A) (1.25) = 14.00 A [I], USE 20 A BREAKER MAIN SERVICE PANEL BUS RATING = 100 A MAIN SERVICE PANEL MAIN OCPD = 100 A 100 A + 20 A SOLAR OCPD = 120 A 100 A BUS (1.2) = 120 A 120 A = 120 A, OK 89033PV :IRE CALCULATIO1S FROM THE MODULES TO THE MAIN SERVICE PANEL: AMBIENT TEMPERATURE = 34°C TEMPERATURE ADDER FOR CONDUIT NOT OFFSET FROM ROOF = 33°C ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT 34°C + 33°C = 67°C = 0.58 I = 14.00 A 14.00 A/0.58 = 24.14 A SELECT WIRE SIZE WITH AMPACITY GREATER THAN 24.14 A, USE 12 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 30 A SELECT CONDUIT FOR (2) 12 AWG THWN-2 & (1) 12 AWG GROUND = 1 2" EMT CONDUIT 1006 S. Austin 07/29/22 FLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs. The all-in-one mount installs fast — no kneeling on hot roofs to install flashing, no prying or cutting shingles, no pulling nails. Simply drive the lag bolt and inject sealant into the base. FLASHLOC’s patented TRIPLE SEAL technology preserves the roof and protects the penetration with a permanent pressure seal. Kitted with lag bolts, sealant, and hardware for maximum convenience. Don’t just divert water, LOC it out! PROTECT THE ROOF Install a high-strength waterproof attachment without lifting, prying or damaging shingles. FLASH LOC LOC OUT WATER With an outer shield 1 contour-conforming gasket 2 and pressurized sealant chamber 3 the Triple-Loc Seal delivers a 100% waterproof connection. Cut Away View HIGH-SPEED INSTALL Simply drive lag bolt and inject sealant into the port 4 to create a permanent pressure seal. Cut Away View FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 3 2 4 1 FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 1.75” STEP 1: SECURE Place FLASHLOC over pilot hole with lag on down-slope side. Align indicator marks on sides of mount with chalk line. Pass included lag bolt and sealing washer through FLASHLOC into pilot hole. Drive lag bolt until mount is held firmly in place. NOTE: The EPDM in the sealing washer will expand beyond the edge of the metal washer when proper torque is applied. PRE-INSTALL Snap chalk lines for attachment rows. On shingle roofs, snap lines 1-3/4” below upslope edge of shingle course. Locate rafters and mark attachment locations. At each location, drill a 7/32” pilot hole. Clean roof surface of dirt, debris, snow, and ice, then fill pilot hole with sealant. NOTE: Space mounts per racking system install specifications. When down pressure is ≥34 psf, span may not exceed 2 ft. STEP 2: SEAL Insert tip of UNIRAC provided sealant into port. Inject until sealant exits both vents. Continue array installation, attaching rails to mounts with provided T-bolts. NOTE: When FLASHLOC is installed over gap between shingle or tabs or vertical joints, fill gap/joint with sealant between mount and upslope edge of shingle course. Use only provided sealant. FLASH LOC INSTALLATION GUIDE 1006 S Austin St 11/29/22 FLASHKIT PRO is the complete attachment solution for composition shingle roofs. Featuring Unirac’s patented SHED & SEAL technology, a weather proof system which provides the ultimate protection against roof leaks. Kittedin10 packsformaximum convenience,ƜashingsandhardwareareavailableinMillorDarkƛnishes. With FLASHKIT pro, you have everything you need for a quick, professional installation. YOUR COMPLETE SOLUTION Flashings, lags, continuous slot L-Feet and hardware CONVENIENT 10 PACKS Packaged for speed and ease of handling FLASHKIT PRO TRUSTED WATER SEAL FLASHINGS FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM  OR CALL (505) 248-2702 FLASH KITPROISTHECOMPLETEFLASHINGAND ATTACHMENTSOLUTIONFORCOMPOSITIONROOFS. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM  OR CALL (505) 248-2702 PRE-INSTALL • Locate roof rafters and snap chalk lines to mark the installation point for each roof attachment. • Drilla7/32ƌpilotholeateachroofattachment.Filleachpilothole with sealant. STEP 1 INSTALL FLASHKITPROFLASHING • AddaU-shapedbeadofroofsealanttotheundersideoftheƜashing with the open side of the U pointing down the roof slope. Slide thealuminumƜashingunderneaththerowofshinglesdirectlyup slopefromthepilotholeasshown.Aligntheindicatormarksonthe lowerendoftheƜashingwiththechalklinesontherooftocenter theraisedholeintheƜashingoverthepilotholeintheroof.When installedcorrectly,theƜashingwillextendunderthetwocoursesof shinglesabovethepilothole. STEP 2 INSTALL L-FOOT • FastenL-footandFlashingintoplacebypassingtheincludedlag boltandpre-installedstainlesssteel-backedEPDMwasherthrough theL-footEPDMgrommet,andtheraisedholeintheƜashing,into the pilot hole in the roof rafter. • DrivethelagboltdownuntiltheL-footisheldƛrmlyinplace. Itis normalfortheEPDMontheundersideofthestainlesssteelbacked EPDMwashertocompressandexpandbeyondtheoutsideedgeof the steel washer when the proper torque is applied. • Usecautiontoavoidover-torqueing thelag boltifusing animpactdriver. • RepeatSteps1and2ateachroofattachmentpoint. STEP 3 ATTACHL-FOOTTORAIL • Inserttheincluded3/8"-16T-boltsintothelowerslotontheRail (soldseparately),spacingtheboltstomatchthespacingbetween the roof attachments. • Position the Rail against the L-Foot and insert the threaded end of theT-BoltthroughthecontinuousslotintheL-Foot.Applyanti-seize toboltthreadstopreventgallingoftheT-boltandincluded3/8ƌ serratedƜangenut.Placethe3/8ƌƜangenutontheT-boltand ƛngertighten.RepeatSTEP 3untilallL-FeetaresecuredtotheRail withaT-bolt.AdjustthelevelandheightoftheRailandtorqueeach boltto30ft-lbs. INSTALL FLASHKITPROFLASHING STEP 1 STEP 2 STEP 3 INSTALL L-FOOT ATTACHL-FOOTTORAIL FLASHKIT PRO INSTALLATION GUIDE 1006 S. Austin 07/29/22 HOMEOWNER: THANH LE PH: 714.722.8071 ADDRESS: 1006 S. AUSTIN STREET SANTA ANA, CA 92704 DATE: 11/4/22DATE: 11/4/22 ECOSOLAR USA ELECTRICAL LLC 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 SCO3E O) :OR. INSTALL (7) SUNPOWER SPR-M425-H-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL. 9ICI1 IT< 0A3 LE RESIDENCE S+EET I1'E; SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL SHEET 4 CALCULATIONS, SIGNS ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, STRUCTURAL REPORT NTS S+EET 1OTICE A1 < C+A1*ES TO OR USES O ) T+ESE 'OCU0E1TS'RA:I1*S :IT+OUT T+E :RITTE1 CO1SE1T O) -E11I)ER .E00E OR SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE'  O)  PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 *E1ERAL 1OTES 1. THIS SYSTEM COMPLIES WITH THE 2019 CRC, 2019 CBC, 2019 CFC, AND THE 2019 CEC. 2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY HAS BEEN NOTIFIED. 3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. 4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. 5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE UL 1741 COMPLIANT. 6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER. 7. CONDUCTORS ARE 90° C RATED COPPER WIRE. 8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT RESISTANT. 9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED IN A METAL RACEWAY. 10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE PROTECTED IN CONDUIT. 11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES AND RAILS AND SECURED IN PLACE. 12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS. 14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED TO THE WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. 17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA REGULATIONS. 89033PVR1 3+OTO9OLTAIC SOLAR 3RO-ECT I1)OR0ATIO1 SYSTEM SIZE: 2.975 kW (DC) MODULES:(7) SUNPOWER SPR-M425-H-AC AC MODULES PEAK POWER = 425 W MAX OUTPUT CURRENT = 1.60 A MAX OCPD = 20 A MAX NUMBER IN SERIES = 10 TEMP. COEFF. OF POWER = -0.29%/°C DIMENSIONS = 73.7" X 40.6" X 1.3" WEIGHT = 48.0 LBS ARRAY:INSTALLED WEIGHT = 2.8 PSF ROOF COVERAGE = 145 SF, ARRAYS COVER 10% OF TOTAL ROOF AREA MOUNTING HARDWARE: SUNPOWER INVISIMOUNT RAIL UNIRAC FLASHLOC ATTACHMENTS 5 16" STAINLESS STEEL LAG BOLTS @ 72" OC OR LESS WITH A MINIMUM OF 21 2" PENETRATION INTO ROOF RAFTERS EXISTING ROOF INFO: 1 STORY, COMPOSITION SHINGLE 2 X 4 RAFTERS @ 24" OC Revision # 20178023 ISS. 11/23/22 Revision to # 20176806 ISS. 07/26/22 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 1006 S Austin St 11/29/22 HOMEOWNER: THANH LE PH: 714.722.8071 ADDRESS: 1006 S. AUSTIN STREET SANTA ANA, CA 92704 DATE: 6/2/22DATE: 6/2/22 ECOSOLAR USA ELECTRICAL LLC 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 SCO3E O) :OR. INSTALL (7) SUNPOWER SPR-M425-H-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. 9ICI1 IT< 0A3 LE RESIDENCE S+EET I1'E; SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL SHEET 4 CALCULATIONS, SIGNS ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, STRUCTURAL REPORT NTS S+EET 1OTICE A1 < C+A1*ES TO OR USES O ) T+ESE 'OCU0E1TS'RA:I1*S :IT+OUT T+E :RITTE1 CO1SE1T O) -E11I)ER .E00E OR SCOTT +ARRIS ARE STRICTL< 3RO+I%ITE'  O)  PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 *E1ERAL 1OTES 1. THIS SYSTEM COMPLIES WITH THE 2019 CRC, 2019 CBC, 2019 CFC, AND THE 2019 CEC. 2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY HAS BEEN NOTIFIED. 3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. 4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. 5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE UL 1741 COMPLIANT. 6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER. 7. CONDUCTORS ARE 90° C RATED COPPER WIRE. 8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT RESISTANT. 9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED IN A METAL RACEWAY. 10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE PROTECTED IN CONDUIT. 11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES AND RAILS AND SECURED IN PLACE. 12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS. 14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED TO THE WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. 17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA REGULATIONS. 89033PV 3+OTO9OLTAIC SOLAR 3RO-ECT I1)OR0ATIO1 SYSTEM SIZE: 2.975 kW (DC) MODULES:(7) SUNPOWER SPR-M425-H-AC AC MODULES PEAK POWER = 425 W MAX OUTPUT CURRENT = 1.60 A MAX OCPD = 20 A MAX NUMBER IN SERIES = 10 TEMP. COEFF. OF POWER = -0.29%/°C DIMENSIONS = 73.7" X 40.6" X 1.3" WEIGHT = 48.0 LBS ARRAY:INSTALLED WEIGHT = 2.8 PSF ROOF COVERAGE = 145 SF, ARRAYS COVER 10% OF TOTAL ROOF AREA MOUNTING HARDWARE: SUNPOWER INVISIMOUNT RAIL UNIRAC FLASHKIT PRO ATTACHMENTS 5 16" STAINLESS STEEL LAG BOLTS @ 72" OC OR LESS WITH A MINIMUM OF 21 2" PENETRATION INTO ROOF RAFTERS EXISTING ROOF INFO: 1 STORY, COMPOSITION SHINGLE 2 X 4 RAFTERS @ 24" OC Bldg permit# 101111238 Elect permit# 20176806 Permits issued on 7/26/22 1006 S. Austin 07/29/22