Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1202 S Karen Ave - Plan
HOMEOWNER: DENNIS HOANG PH: 714.588.4468 ADDRESS: 1202 S. KAREN AVENUE SANTA ANA, CA 92704 DATE: 5/2/22DATE: 5/2/22 (&262/$5 86$ (/(&75,&$///& 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 6&23(2):25. INSTALL (17) SUNPOWER SPR-X22-360-E-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) LOAD CENTER, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. 9,&,1,7<0$3 HOANG RESIDENCE 6+((7,1'(; SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL SHEET 4 CALCULATIONS, SIGNS ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, STRUCTURAL REPORT NTS 6+((7 127,&( $1<&+$1*(67225 86(62)7+(6('2&80(176'5$:,1*6:,7+2877+( :5,77(1&216(172)-(11,)(5 .(00(25 6&277+$55,6$5(675,&7/<352+,%,7(' 2) PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 (17) SUNPOWER SPR-X22-360-E-AC AC MODULES PEAK POWER = 360 W MAX OUTPUT CURRENT = 1.31 A MAX OCPD = 20 A MAX NUMBER IN SERIES = 12 TEMP. COEFF. OF POWER = -0.29%/°C DIMENSIONS = 61.3" X 41.2" X 1.8" WEIGHT = 42.9 LBS *(1(5$/127(6 1. THIS SYSTEM COMPLIES WITH THE 2019 CRC, 2019 CBC, 2019 CFC, AND THE 2019 CEC. 2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY HAS BEEN NOTIFIED. 3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. 4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. 5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE UL 1741 COMPLIANT. 6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER. 7. CONDUCTORS ARE 90° C RATED COPPER WIRE. 8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT RESISTANT. 9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED IN A METAL RACEWAY. 10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE PROTECTED IN CONDUIT. 11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES AND RAILS AND SECURED IN PLACE. 12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS. 14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE INSTALLED PER CEC 250.50. THE ELECTRICAL SERVICE WILL BE BONDED TO THE WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. 17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA REGULATIONS. 3+27292/7$,&62/$5 352-(&7,1)250$7,21 SYSTEM SIZE: 6.120 kW (DC) MODULES: ARRAY:INSTALLED WEIGHT = 2.9 PSF ROOF COVERAGE = 300 SF, LESS THAN 50% OF TOTAL ROOF AREA MOUNTING HARDWARE: SUNPOWER INVISIMOUNT RAIL UNIRAC STANDOFF W/ CHEM CURB ATTACHMENTS 5 16" STAINLESS STEEL LAG BOLTS @ 72" OC OR LESS WITH A MINIMUM OF 21 2" PENETRATION INTO ROOF RAFTERS EXISTING ROOF INFO: 1 STORY, ROLLED COMPOSITION 2 X 6 RAFTERS @ 24" OC Bldg #101110579 Elect #20176280 Permits issued on 6/29/22 1202 S Karen Ave 06/29/22 HOMEOWNER: DENNIS HOANG PH: 714.588.4468 ADDRESS: 1202 S. KAREN AVENUE SANTA ANA, CA 92704 DATE: 5/2/22DATE: 5/2/22 (&262/$5 86$ (/(&75,&$///& 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 6&23(2):25. INSTALL (17) SUNPOWER SPR-X22-360-E-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) LOAD CENTER, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. (/(&75,&$//,1(',$*5$0 6+((7 127,&( $1<&+$1*(67225 86(62)7+(6('2&80(176'5$:,1*6:,7+2877+( :5,77(1&216(172)-(11,)(5 .(00(25 6&277+$55,6$5(675,&7/<352+,%,7(' 2) PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 MAIN SERVICE INFO: 100 A, 120/240 VAC, 1Ø, 3-WIRE METER #222013-843290 30A 100A EXISTING BUILDING GROUNDING ELECTRODE SYSTEM M EXISTING SERVICE PANEL: 125 A BUS RATED, 240 VAC, 1ØSOURCE CIRCUIT #1: 9 MODULES, 240 VAC L1 L2 L1 L2 L1 L2 SOURCE CIRCUIT #2: 8 MODULES, 240 VAC NEMA 3R, 240 VAC JUNCTION BOX L1 L2 L1 L2 L1 L2 + - + - + - + - + - + - USE SUNPOWER INTEGRATED GROUNDING TO GROUND ALL MODULES, JUNCTION BOXES AND ANY OTHER METAL PARTS AND GROUND LUGS WITH #6 AWG SOLID COPPER WHERE NEEDED 12 AWG (TYP) SUNPOWER SPR-X22-360-E-AC SUNPOWER SPR-X22-360-E-AC SUNPOWER SPR-X22-360-E-AC SUNPOWER SPR-X22-360-E-AC SUNPOWER SPR-X22-360-E-AC SUNPOWER SPR-X22-360-E-AC (4) 10 AWG THWN-2 & (1) 10 AWG GROUND IN 3 4" EMT CONDUIT 20A 20A LOAD CENTER 125 A BUS RATED 240 VAC, 1Ø (3) 10 AWG THWN-2 & (1) 10 AWG GROUND IN 3 4" EMT CONDUIT QUAD BREAKERS TO MAKE SPACE FOR SOLAR BREAKER 20A TO M O N I T O R I N G G L1 L2 60 A, 240 VAC, 1Ø AC DISCONNECT LOCKABLE, VISIBLE KNIFE-BLADE TYPE (3) 10 AWG THWN-2 & (1) 10 AWG GROUND IN 3 4" EMT CONDUIT 1202 S Karen Ave 06/29/22 Expedited Permit Process for PV Systems - AC Module1 Expedited Permit Process for PV Systems AC Module The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the AC Module to use with the Expedited Permit Process. The Standard String, Micro-Inverter, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 1202 S Karen Ave 06/29/22 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems AC Module The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 1202 S Karen Ave 06/29/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 AC Module Site Plan ECOSOLAR USA ELECTRICAL 13962 SEABOARD CIR GARDEN GROVE,CA 82840 1202 S KAREN AVE. SANTA ANA, CA 92704 6.120kW 1202 S Karen Ave 06/29/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 AC Module Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for AC Module PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A CONDUIT SIZE N/A N/A N/A DESCRIPTIONTAG 1 2 3 4 5 6 7 PART NUMBER NOTES FOR UNUSED AC MODULES PUT "N/A in BLANK ABOVE 1 2 2 3 EQUIPMENT SCHEDULE J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 5 6 7 5 3 4 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ AC MODULES IN BRANCH- CIRCUIT MOD __1__ DC AC MOD __1__ DC AC MOD __1__ DC AC ____ AC MODULES IN BRANCH- CIRCUIT MOD __1__ DC AC MOD __1__ DC AC MOD __1__ DC AC 1 13962 SEABOARD CIR GARDEN GROVE,CA 82840 ECOSOLAR USA ELECTRICAL 1202 S KAREN AVE. SANTA ANA, CA 92704 6.120kW 1202 S Karen Ave 06/29/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for AC Module Electrical Diagram Contractor Name, Address and Phone: Bill Ted Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: NOMINAL OPERATING AC VOLTAGE NOMINAL OPERATING AC FREQUENCY MAXIMUM AC POWER MAXIMUM AC CURRENT MAXIMUM OCPD RATING AC MODULE MAKE AC MODULE MODEL AC MODULE RATINGS (Guide Appendix C) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT (N/A) 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH AC MODULE CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ___oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR 6 OR LESS CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR AC MODULES INVERTER OUTPUT CIRCUITS WITH 12 AMPS OR LESS WHEN PROTECTED BY A 15- AMP OR SMALLER OCPD. b) 10 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR AC MODULES INVERTER OUTPUT CIRCUITS WITH 16 AMPS OR LESS WHEN PROTECTED BY A 20- AMP OR SMALLER OCPD. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix F): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNSSEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) N/A since no dc wiring AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) ECOSOLAR USA ELECTRICAL 13962 SEABOARD CIR 1202 S KAREN AVE. SANTA ANA, CA 92704GARDEN GROVE,CA 82840 6.120kW 1202 S Karen Ave 06/29/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11 x 17 size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2 minimum to 10 maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16 lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturers PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1202 S Karen Ave 06/29/22 HOMEOWNER: DENNIS HOANG PH: 714.588.4468 ADDRESS: 1202 S. KAREN AVENUE SANTA ANA, CA 92704 DATE: 5/2/22DATE: 5/2/22 (&262/$5 86$ (/(&75,&$///& 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 6&23(2):25. INSTALL (17) SUNPOWER SPR-X22-360-E-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) LOAD CENTER, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. SERVICE POINT & UTILITY METERING PV SYSTEM DISCONNECT FOR UTILITY OPERATION CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN. ADDRESS: 1202 S. KAREN AVENUE, SANTA ANA, CA 92704 SOLAR ARRAY (ON ROOF) N TO BE INSTALLED ON THE OUTSIDE COVER OF THE MAIN SERVICE DISCONNECT: 6+((7 127,&( $1<&+$1*(67225 86(62)7+(6( '2&80(176'5$:,1*6:,7+2877+( :5,77(1&216(172)-(11,)(5 .(00(25 6&277+$55,6$5(675,&7/<352+,%,7(' 2) PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 6<67(0 6,*1$*( ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND ATTACHED WITH WEATHERPROOF ADHESIVE OR OTHER APPROVED METHOD. ALL LETTERS SHALL BE A MINIMUM OF 3 8" HEIGHT AND ALL CAPITALIZED. ALL CONDUIT, JUNCTION BOXES AND OTHER ENCLOSURES SHALL BE MARKED AT 10' MAX INTERVALS AND AT ALL BENDS, TERMINATIONS, SPLICES OR CONNECTIONS WITH "WARNING: PHOTOVOLTAIC POWER SOURCE". WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION TO BE INSTALLED AT ALL SERVICEABLE PANELS OR BOXES AND AT ALL DISCONNECTS: RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM RATED AC OUTPUT CURRENT = 27.84 A NOMINAL OPERATING AC VOLTAGE = 240 V TO BE INSTALLED NEXT TO THE SOLAR BREAKER: TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TO BE INSTALLED ON THE FRONT OF THE MAIN SERVICE DISCONNECT: "SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN" SHALL BE BLACK LETTERING ON YELLOW BACKGROUND. THE REMAINDER OF THE SIGN SHALL BE BLACK LETTERING ON WHITE BACKGROUND. 6<67(0 &$/&8/$7,216 NUMBER OF MODULES IN EACH CIRCUIT = 9 MODULE MAX OUTPUT CURRENT = 1.31 A (9) (1.31 A) (1.25) = 14.74 A [Ic], USE 15 A BREAKERS TOTAL NUMBER OF MODULES = 17 (17) (1.31 A) (1.25) = 27.84 A [I], USE 30 A BREAKER MAIN SERVICE PANEL BUS RATING = 125 A MAIN SERVICE PANEL MAIN OCPD = 100 A 100 A + 30 A SOLAR OCPD = 130 A 125 A BUS (1.2) = 150 A 130 A < 150 A, OK :,5(&$/&8/$7,216 FROM THE MODULES TO THE LOAD CENTER: AMBIENT TEMPERATURE = 34°C TEMPERATURE ADDER FOR CONDUIT NOT OFFSET FROM ROOF = 33°C ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT 34°C + 33°C = 67°C = 0.58 Ic = 14.96 A 14.96 A/0.58 = 25.79 A NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT = 4 ADJUSTMENT FACTOR PER TABLE 310.15(B)(3)(a) FOR CONDUIT FILL (4-6 CONDUCTORS IN CONDUIT) = 0.80 25.79 A/0.80 = 33.24 A SELECT WIRE SIZE WITH AMPACITY GREATER THAN 33.24 A, USE 10 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 40 A SELECT CONDUIT FOR (4) 10 AWG THWN-2 & (1) 10 AWG GROUND = 3 4" EMT CONDUIT FROM THE LOAD CENTER TO THE MAIN SERVICE PANEL: ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR 90°C INSULATED CONDUCTOR AT 42°C = 0.96 I = 27.84 A 27.84 A/0.96 = 29.00 A SELECT WIRE SIZE WITH AMPACITY GREATER THAN 29.00 A, USE 10 AWG THWN-2 COPPER WIRE WITH AN AMPACITY OF 40 A SELECT CONDUIT FOR (3) 10 AWG THWN-2 & (1) 10 AWG GROUND = 3 4" EMT CONDUIT 1202 S Karen Ave 06/29/22 'DWDVKHHW 6XQ3RZHUp;6HULHV;_; 6XQ3RZHU p 5HVLGHQWLDO $&0RGXOH %XLOWVSHFLILFDOO\IRUXVHZLWKWKH6XQ3RZHU(TXLQR[ȠV\VWHPWKHRQO\IXOO\ LQWHJUDWHGVROXWLRQGHVLJQHGHQJLQHHUHGDQGZDUUDQWHGE\RQHPDQXIDFWXUHU 0D[LPXP 3RZHU0LQ LPDOLVW'HVLJQ ΖQGXVWU\OHDGLQJHIILFLHQF\PHDQVPRUHSRZHUDQGVDYLQJV SHUDYDLODEOHVSDFH:LWKIHZHUPRGXOHVUHTXLUHG DQG KLGGHQPLFURLQYHUWHUVOHVVLVWUXO\PRUH +LJKHVW/LIHWLPH(QHUJ\DQG6DYLQJV 'HVLJQHGWRGHOLYHUPRUHHQHUJ\RYHU\HDUVLQ UHDOZRUOGFRQGLWLRQVOLNHSDUWLDOVKDGHDQG KLJKWHPSHUDWXUHV <HDUVRIRSHUDWLR Q 8SWR PRUH OLIHWLPH HQHUJ\ %HVW5HOLDELOLW\%HVW:DUUDQW\ :LWKPRUHWKDQPLOOLRQPRGXOHVGHSOR\HGDURXQG WKHZRUOG6XQ3RZHUWHFKQRORJ\LVSURYHQWRODVW7KDWȇV ZK\ZHVWDQGEHKLQGRXUPRGXOHDQGPLFURLQYHUWHU ZLWKWKHLQGXVWU\ȇVEHVW\HDU&RPELQHG3RZHUDQG 3URGXFW:DUUDQW\LQFOXGLQJWKHKLJKHVW3RZHU:DUUDQW\ LQVRODU <HDUVRIRSHUDWLRQ PRUH SRZHU LQ\HDU (6HULHVDQG;6HULHV $QG%HWWHU 7KH6XQ3RZHUp 0D[HRQp 6RODU&HOO ȏ (QDEOHVKLJKHVWHIILFLHQF\ PRGXOHVDYDLODEOH ȏ 8QPDWFKHGUHOLDELOLW\ ȏ 3DWHQWHGVROLGPHWDOIRXQGDWLRQ SUHYHQWVEUHDNDJHDQG FRUURVLRQ )DFWRU\LQWHJUDWHG0LFURLQYHUWHU ȏ 6LPSOHUIDVWHULQVWDOODWLRQ ȏ ΖQWHJUDWHGZLUHPDQDJHPHQW UDSLGVKXWGRZQ ȏ (QJLQHHUHGDQGFDOLEUDWHGE\ 6XQ3RZHUIRU6XQ3RZHUPRGXOHV :D U U D QWH GPR G XOHSR ZHU \HD U HQHU J\\LH OGSH U : VXQSRZHUFRP ;6HULHV;_;6XQ3RZHUp5HVLGHQWLDO$&0RGXOH $&(OHFWULFDO'DWD 3HDN 2XWSXW3RZHU9$ 9$ 0D[&RQWLQXRXV2XWSXW3RZHU9$ 9$ 1RP/Ȃ/9ROWDJH5DQJH9Ȃ Ȃ 0D[&RQWLQXRXV2XWSXW&XUUHQW$ 0D[8QLWVSHU$//%UDQFK&LUFXLWVLQJOHSKDVH WZRSROHZ\H &(&:HLJKWHG(IILFLHQF\ 1RP)UHTXHQF\ +] ([WHQGHG)UHTXHQF\5DQJH Ȃ+] $&6KRUW&LUFXLW)DXOW&XUUHQW2YHU&\FOHV $UPV 2YHUYROWDJH&ODVV$&3RUW ΖΖΖ $&3RUW%DFNIHHG&XUUHQW P$ 3RZHU)DFWRU6HWWLQJ 3RZHU)DFWRUDGMXVWDEOH OHDG ODJ 1RDFWLYHSKDVHEDODQFLQJIRUWKUHHSKDVHLQVWDOODWLRQV 6XQ3RZHU: FRPSDUHGWRDFRQYHQWLRQDOPRGXOHRQVDPHVL]HGDUUD\V: HIILFLHQWDSSUR[PPRUHHQHUJ\SHUZDWWEDVHGRQWKLUGSDUW\PRGXOH FKDUDFWHUL]DWLRQDQG396LP\UVORZHUGHJUDGDWLRQDPSHDX =HWDOȊ6XQ3RZHU 0RGXOH'HJUDGDWLRQ5DWHȋ6XQ3RZHUZKLWHSDSHU %DVHGRQVHDUFKRIGDWDVKHHWYDOXHVIURP ZHEVLWHVRIWRS PDQXIDFWXUHUVSHU Ζ+6DVRI -DQXDU\ UDQNLQȊ)UDXQKRIHU39 'XUDELOLW\ΖQLWLDWLYHIRU6RODU0RGXOHV3DUW ȋ397HFK3RZHU 0DJD]LQH&DPSHDX=HWDOȊ6XQ3RZHU0RGXOH 'HJUDGDWLRQ5DWHȋ6XQ3RZHUZKLWH SDSHU )DFWRU\VHWWR DGHIDXOWVHWWLQJV&$5XOHGHIDXOWVHWWLQJVSURILOHVHWGXULQJ FRPPLVVLRQLQJ6HHWKH(TXLQR[ΖQVWDOODWLRQ XLGHIRUPRUHLQIRUPDWLRQ 6WDQGDUG7HVW&RQGLWLRQV:PtLUUDGLDQFH$0 r&15(/FDOLEUDWLRQ VWDQGDUG6206FXUUHQW/$&&6))DQGYROWDJHOO'& YROWDJHLVIXOO\FRQWDLQHGZLWKLQWKH PRGXOH 7KLVSURGXFWLV8//LVWHGDV3956(DQGFRQIRUPVZLWK1(&DQG1(& DQG&5XOH5DSLG6KXWGRZQRI396\VWHPVIRU$&DQG'&FRQGXFWRUV ZKHQLQVWDOOHGDFFRUGLQJWRPDQXIDFWXUHUȇVLQVWUXFWLRQV 6HHZZZVXQSRZHUFRPIDFWVIRUPRUHUHIHUHQFHLQIRUPDWLRQ )RUPRUHGHWDLOVVHHH[WHQGHGGDWDVKHHWZZZVXQSRZHUFRPGDWDVKHHWV 6SHFLILFDWLRQVLQFOXGHGLQWKLVGDWDVKHHWDUHVXEMHFWWRFKD QJHZLWKRXWQRWLFH k6XQ3RZHU &RUSRUDWLRQ$OO5LJKWV5HVHUYHG68132:(5WKH 68132:(5ORJRDQG0$;(21DUHUHJLVWHUHGWUDGHPDUNVRI6XQ3RZHU &RUSRUDWLRQLQWKH86DQGRWKHUFRXQWULHVDVZHOO68132:(5 3OHDVHUHDGWKH6DIHW\DQGΖQVWDOODWLRQΖQVWUXFWLRQVIRUGHWDLOV5HY$ '&3RZHU'DWD 635;($& 635;($& 1RPLQDO3RZHU3QRP: : 3RZHU7ROHUDQFH+5/−0%+5/−0% 0RGXOH(IILFLHQF\ 7HPS&RHI3RZHU−r& −0.29%/°& 6KDGH7ROHUDQFH ȏ7KUHHE\SDVVGLRGHV ȏΖQWHJUDWHG PRGXOHOHYHOPD[LPXP SRZHUSRLQWWUDFNLQJ 7HVWHG2SHUDWLQJ&RQGLWLRQV 2SHUDWLQJ7HPS−r)WR°F (−40°Cto+60r& 0D[$PELHQW7HPSr)r& 0D[/RDG:LQG SVI3DNJPtIURQW EDFN 6QRZSVI3DNJPtIURQW ΖPSDFW5HVLVWDQFHLQFKPPGLDPHWHUKDLODWPSKPV 0HFKDQLFDO'DWD 6RODU&HOOV0RQRFU\VWDOOLQH0D[HRQ*HQΖΖΖ )URQW*ODVV+LJKWUDQVPLVVLRQWHPSHUHGJODVVZLWK DQWLUHIOHFWLYHFRDWLQJ (QYLURQPHQWDO 5DWLQJ 0RGXOH2XWGRRUUDWHG ΖQYHUWHU1(0$7\SH&ODVVΖΖ )UDPH&ODVVEODFNDQRGL]HGKLJKHVW$$0$UDWLQJ :HLJKWOENJ 5HFRPPHQGHG 0D[ 0RGXOH6SDFLQJLQPP :DUUDQWLHV&HUWLILFDWLRQVDQG&RPSOLDQFH :DUUDQWLHVȏ\HDUOLPLWHGSRZHUZDUUDQW\ ȏ\HDUOLPLWHGSURGXFWZDUUDQW\ &HUWLILFDWLRQV DQG &RPSOLDQFH ȏ8/ ȏ8/Ζ((( ȏ8/$&0RGXOH7\SHILUHUDWHG ȏ8/Ζ(& ȏ)&&3DUW&ODVV% ȏΖ&(6&ODVV% ȏ&$1&6$&12 ȏ&$5XOH8/6$ LQFOXGHV9ROW9DUDQG5HDFWLYH3RZHU3ULRULW\ ȏ8//LVWHG395DSLG6KXWGRZQ(TXLSPHQW (QDEOHVLQVWDOODWLRQLQDFFRUGDQFHZLWK ȏ1(&&PRGXOH ȏ1(&5DSLG 6KXWGRZQLQVLGHDQG RXWVLGHWKHDUUD\ ȏ1(&$&&RQQHFWRUV$Ȃ( :KHQXVHGZLWKΖQYLVL0RXQWUDFNLQJDQGΖQYLVL0RXQWDFFHVVRULHV 8/ ȏ0RGXOHJURXQGLQJDQGERQGLQJWKURXJKΖQYLVL0RXQW ȏ&ODVV$ILUHUDWHG :KHQXVHGZLWK$&PRGXOH4&DEOHVDQGDFFHVVRULHV8/DQG 8/ ȏ5DWHGIRUORDG EUHDN GLVFRQQHFW 3Ζ' 7HVW 3RWHQWLDOLQGXFHGGHJUDGDWLRQIUHH 1202 S Karen Ave 06/29/22 SunPower ® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates even module spacing • Simple, pre-drilled rail splice • UL 2703 Listed integrated grounding Flexible Design • Addresses nearly all sloped residential roofs • Design in landscape and portrait • Rails enable easy obstacle management Customer-Preferred Aesthetics •#1 module and #1 mounting aesthetics • Best-in-class system aesthetics ȏ Premium,low-proȴledesign • Black anodized components • Hidden mid clamps and end clamps hardware,andcapped,ȵ ushrails Part of Superior System •Built for use with SunPower DC and AC modules • Best-in-class system reliability and aesthetics • Combine with SunPower modules and monitoring app sunpower.com Elegant Simplicity SunPower ® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installationtime,designȵexibility,and superioraesthetics. TheΖnvisiMountproductwasspeciȴcallyenvisionedand engineered to pair with SunPower modules. The resulting system-level approach will amplify the aesthetic and installationbeneȴtsforbothhomeownersandinstallers. SunPower ® InvisiMount™ | Residential Mounting System InvisiMount Component Details Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug)106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) Roof Attachment Hardware Supported by InvisiMount System Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal Interface for Other Roof Attachments InvisiMount Operating Conditions Temperature ȫ40°Cto90°C(ȫ40°Fto194°F) Max. Load 2400 Pa uplift 5400 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation ΖnvisiMountWarrantiesAndCertiȴcations Warranties 25-year product warranty 5-yearȴnishwarranty Certiȴcations UL 2703 Listed ClassAȴreratingwhendistancebetween roof surface and bottom of SunPower moduleframeisȱ3.5ȋ *Module frame that is compatible with the InvisiMount system required for hardware interoperability. © 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. Speciȴcationsincludedinthisdatasheetaresubjecttochangewithoutnotice. InvisiMount Component Images Module* / Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap Module* / End Clamp and Rail sunpower.com Document #509506 Rev B 1202 S Karen Ave 06/29/22 1202 S Karen Ave 06/29/22 HOMEOWNER: DENNIS HOANG PH: 714.588.4468 ADDRESS: 1202 S. KAREN AVENUE SANTA ANA, CA 92704 DATE: 5/2/22DATE: 5/2/22 (&262/$5 86$ (/(&75,&$///& 13962 SEABOARD CIRCLE GARDEN GROVE, CA 92840 PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 6&23(2):25. INSTALL (17) SUNPOWER SPR-X22-360-E-AC SOLAR ELECTRIC MODULES ON THE EXISTING 1ST STORY COMPOSITION ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE, JUNCTION BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL (1) LOAD CENTER, (1) AC DISCONNECT, AND INSTALL OCPD IN MAIN SERVICE PANEL. NOTE: DIMENSIONS AND FEATURES SHOWN ARE CLOSE TO SCALE BUT WERE TAKEN FROM A FIELD SURVEY AND APPROXIMATIONS MADE USING GOOGLE EARTH. PROPERTY LINE (E) 100 AMP MAIN SERVICE PANEL 6 .$5(1 $9(18( N SCALE: 1/16"=1' 8 16 32 48 VENT (TYP) PROPERTY LINE (N) LOAD CENTER 6,7(522)3/$1 13 ARRAY #1: (17) MODULES TILT = 0°, AZ = 180° PROPERTY LINE 6+((7 127,&( $1<&+$1*(67225 86(62)7+(6('2&80(176'5$:,1*6:,7+2877+( :5,77(1&216(172)-(11,)(5 .(00(25 6&277+$55,6$5(675,&7/<352+,%,7(' 2) PLANS PREPARED BY: JENNIFER KEMME PH: 909.748.1300 SUNPOWER INVISIMOUNT RAIL MOUNTING SYSTEM WITH UNIRAC STANDOFF W/ CHEM CURB ATTACHMENTS ATTACHMENTS (USE 5 16 " STAINLESS STEEL LAG BOLTS @ 72" OC OR LESS WITH A MINIMUM EMBEDMENT OF 21 2" INTO ROOF RAFTERS), WATERPROOF ALL CONNECTION PER MANUFACTURER'S INSTRUCTIONS 3" MIN 8" MAX EXISTING 2 X 6 RAFTERS @ 24" OC MODULES: 61.3" X 41.2" 42.9 LBS EACH EXISTING 1-STORY ROOF: ROLLED COMPOSITION, FELT & 12" SHEATHING OVER RAFTERS NTS (/(9$7,21'(7$,/ 3' FIRE CLEARANCE TOTAL ROOF AREA = 1673 SF TOTAL SOLAR AREA = 300 SF 300 SF/1673 SF = 0.18 ARRAYS COVER 18% OF TOTAL ROOF AREA 14 15 16 17 9 10 11 12 56 7 8 1 2 3 4 3' 42'-2" 6'-6" 23'-10" 19'-6" (N) AC DISCONNECT 1202 S Karen Ave 06/29/22 STRUCTURAL ANALYSIS FOR NEW PHOTOVOLTAIC SOLAR SYSTEM NOTE: THESE CALCULATIONS ARE BASED ON INFORMATION AND MEASUREMENTS PROVIDED BY THE CONTRACTOR FROM HIS SITE INSPECTION. 1 Project Information:PV SOLAR ARRAY: HOANG RESIDENCE Latitude 33.7322° deg N 1202 S. KAREN AVENUE, SANTA ANA, CA 92704 Longitude -117.930° deg W Wind Speed 110 mph 89 mph (ASCE 7-16) Wind Exposure C Site Class D Seismic Design Category D 2 Loads: Existing Roof Dead Loads: 2 x 6 Rafters @ 24" OC 1.1 psf 1/2" Roof Sheathing 1.7 psf Roof Felt 1.5 psf Composition 5.0 psf Miscellaneous 3.2 psf Total 12.5 psf Existing Snow Load:0.0 psf Existing Roof Live Load:20.0 psf Proposed Roof Live Load:20.0 psf Wind Load: Using CBC 2019 (ASCE 7-16), Chapter 29: Wind Loads on Rooftop Equipment, the following wind pressures were calculated. p = qh (GCp) (ge) (ga) = 10.15 -52.22 psf qh = 0.00256 Kz Kzt Kd Ke V2 = 21.76 psf Kz = 0.85 (0-15 = 0.85, 20 = 0.90, 25 = 0.94, 30 = 0.98, 40 = 1.04) GCp = 0.7 -3.6 (Roof pitch = 0 deg, Zone = 2, Aeff = 18.0 sf) ge = 1.50 ga = 0.80 Lag Bolt Capacity: 5/16" lag bolt capacity = 270 lbs per inch embedment With 2 1/2" minimum embedment, capacity = 675 lbs Required Capacity: 52.22 psf * 17 modules * 18.0 sf = 15980.5 lbs 15980.5 lbs / 26 lag bolt connections = 614.6 lbs The pull-out capacity of the 5/16" lag bolts with a minimum 2 1/2" embedment into the roof rafter is sufficient to meet the demand of the wind uplift force on the solar system. Seismic Load: Per the CEBC 2019 Section 503.4, if the demand-capacity ratio of the lateral load-carrying elements increases less than 10% due to the addition of the solar system, no special provisions or structural modifications are required. Existing Roof Weight = 12.5 psf * 1675 sf = 20937.5 lbs Weight of Solar System = 17 modules * 42.9 lbs + 153 lbs of racking = 882 lbs 882 lbs / 20938 lbs = 0.04 The increase in load from the solar system will not increase the demand-capacity ratio of the existing lateral load-carrying elements by over 10%. NOTICE:VISION CIVIL ENGINEERING: JENNIFER KEMME, PE ANY CHANGES TO OR USES OF THESE DOCUMENTS 12273 11TH STREET, YUCAIPA, CA 92399 WITHOUT THE WRITTEN CONSENT OF VISION 909.754.8300, JENKEMME@VISIONCE.COM CIVIL ENGINEERING IS STRICTLY PROHIBITED.RCE 73054, EXP 12/31/22 Prepared by JENNIFER KEMME 5/11/2022 Page 1 1202 S Karen Ave 06/29/22 STRUCTURAL ANALYSIS FOR NEW PHOTOVOLTAIC SOLAR SYSTEM NOTE: THESE CALCULATIONS ARE BASED ON INFORMATION AND MEASUREMENTS PROVIDED BY THE CONTRACTOR FROM HIS SITE INSPECTION. 3 Analysis of Existing Rafter Capacity:PV SOLAR ARRAY: HOANG RESIDENCE 1202 S. KAREN AVENUE, SANTA ANA, CA 92704 Rafter Loads: Solar system dead load = 882 lbs / 26 lag bolts total = 33.9 lbs at each lag bolt Existing roof dead load = 12.5 psf Snow load = 0 psf Roof live load = 20 psf Wind load = 119.5 lbs, 614.6 lbs Rafter span = 11.0 ft Load Combinations That Apply: #1: D + Lr or S = 12.5 psf + 33.9 lbs at each lag bolt + 20.0 psf #2: D + 0.75(0.6W) + 0.75(Lr or S) = 12.5 psf + 33.9 lbs at each lag bolt) + (0.75 (0.6) 119.5 lbs at each lag bolt) + (0.75 ( 20 psf)) #3: 0.6D + 0.6W = 0.6 ( 12.5 psf + 33.9 lbs at each lag bolt) - (0.6) 614.6 lbs at each lag bolt Calculated Maximum Bending Moment: #1: 491.6 ft/lbs + 93.3 ft/lbs = 584.9 ft/lbs [( 33 psf) ( 11 ft^2)] / 8 = 491.6 ft/lbs [( 33.93 lbs) ( 11.0 ft)] / 4 = 93.32 ft/lbs #2: 189.1 ft/lbs + 93.3 ft/lbs + 147.9 ft/lbs + 226.9 ft/lbs = 657.2 ft/lbs [( 12.5 psf) ( 11 ft^2)] / 8 = 189.1 ft/lbs [( 33.93 lbs) ( 11.0 ft)] / 4 = 93.32 ft/lbs 119.5 lbs) ( 11 ft)] / 4 = 147.9 ft/lbs 0.75 [( 20 psf) ( 11 ft^2)] / 8 = 226.9 ft/lbs #3: 113.4 ft/lbs + 56.0 ft/lbs - 1014.1 ft/lbs = -844.7 ft/lbs 0.6 [( 12.5 psf) ( 11 ft^2)] / 8 = 113.4 ft/lbs 0.6 [( 33.93 lbs) ( 11.0 ft)] / 4 = 55.99 ft/lbs 0.6 [( 614.6 lbs) ( 11 ft)] / 4 = 1014.1 ft/lbs Section Required: 844.7 ft/lbs (12) (0.7) / 1518 psi = 4.7 cu in Section Provided: 1.5 ( 5.5 ^2) / 6 = 7.6 cu in 7.6 cu in > 4.7 cu in, OK Calculated Deflection: [5( 32.5 psf / 12) ( 132 in^4)] / [384 (1200000) ( 20.8 )] = 0.43 in Allowable Deflection: 132 in / 240 = 0.55 in 0.55 in > 0.43 in, OK NOTICE: VISION CIVIL ENGINEERING: JENNIFER KEMME, PE ANY CHANGES TO OR USES OF THESE DOCUMENTS 12273 11TH STREET, YUCAIPA, CA 92399 WITHOUT THE WRITTEN CONSENT OF VISION 909.754.8300, JENKEMME@VISIONCE.COM CIVIL ENGINEERING IS STRICTLY PROHIBITED. RCE 73054, EXP 12/31/22 0.75 [(0.6)( Prepared by JENNIFER KEMME 5/11/2022 Page 2 1202 S Karen Ave 06/29/22